Loading...
01-0468-013 PLUMBING SPECIFICATIONS _ Eusebio M. Mora Architect Fla. Lic. # AR0011732 1 THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT _ SHOWN OR INDICATED FOR A COMPLETE PLUMBING SYSTEM IN ACCORD_A.NCE-- WITH THESE DRAWINGS AND WITH THE LOCAL PLUMBING AND-BUILDING CODES. 2 CONTRACTOR SHALL COORDINATE HIS WORK WITH ALL TRADES IN ORDER-TO- AVOID CONFLICTS. NO CHANGES WILL BE ACCEPTED UNLESS -A PRIOR WRITTEN APPROVAL HAS BEEN ISSUED FROM THE ARCHITECT/ENGINEER. - 3 CONTRACTOR SHALL COORDINATE HIS WORK WITH CORRES?CNDING UTILITY = _ COMPANIES IN ORDER TO VERIFY THE POINTS OF CONNECTICN.- _ - _--- 4 CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF ALL=F-.OUIPME T-AND THEIR CORRESPONDING SHOP DRAWINGS BEFORE ROUGH–IN. 5 PROVIDE ALL EXCAVATION, BACKFILL AND COMPACTION REQUIRED BY ALL PLUMNING WORK. 6 PROVIDE COMPLETE ACCESS TO ALL SYSTEM. LOCATE CLEAN–OUTS ON WALLS AND OR FLOORS AS NECESSARY, FOR ACCES AND OF USE PROVIDE PANELS, WHERE NECESSARY FOR THE WATER DISTRIBUTION SYSTEM. 7 PLUMBING CONTRACTOR TO PROVIDE ALL FLASHING AND PITCH PANS AS REQUIRED AT ALL ROOF PENETRATIONS TO ROOFING CONTRACTOR. Z-3 11 8 BUILDING DRAINAGE SYSTEM DISIGN BASE ON 1/8" FT. MINIMUM FALL, ANY 9780 Southwest 16th Street DEVIATIONS SHALL BE APPROVED BY THE ARCHITECT AND ENGINEER. 9 CONTRACTOR TO PROVIDE 1" MINIMUM WATER PIPE CAPPED AT EVERY Miami, Florida 3 3 1 6 5 ELECTRICAL SWITCHGRAR ROOM OR METER ROOM TO BE USED AS GROUND (305) 2 2 9 - 6 8 6 0 (IF APPLICABLE). 10 ALL VALVES UNDERGROUND TO BE INSTALLED IN PROCAST CONCRETE BOXES, BROOKS OR EQUAL. 11 ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND AS FOLLOWS: A SANITARY WASTE AND VENT PIPES AND FITTINGS SHALL BE PVC OR DWV (ASTM –D– 2662) Z B AC CONDENSATE DRAIN SHALL BE SCHEDULE 40 P.V.C. Q C HOT AND COOL WATER LINES SHALL BE COPPER (ASTM–B-88) TYPE "L" _J ABOVE GOUND. TYPE "K" UNDERGROUND. Q_ D PROVIDE DI– ELECTRIC COUPLINGS AS REQUIRED FOR CONNECTION TO DIFFERENT MATERIALS SHUT–OFF VALVES AT FIXTURES AND EQUIPMENT O Ir REQUIRING WATER SUPPY. E INSULATE ALL HOT WATER LINES WITH 1/2" FIBERGLASS WITH SELF Q SEALING UNIVERSAL JACKET. ..i F PLUMBING FIXTURES– AMERICAN STANDARD, KOHLER, CRANE OR EQUAL. IL G FLOOR AND ROOF DRAINS, IF USED, JOSAN OR EQUAL, FLOOR DRAINS //rR� SHALL BE RESEALED. V H ELECTRICAL WATER HEATERS– GLASSLINED, 5 YEARS GUARANTEED A.O. Z SMITH OR EQUAL. m I VALVES – 125 PSI NIBCO SCOTT OR EQUAL. i[Elu Ell I I I I I K HOSE BIBBS CHICAGO 952, OR EQUAL. L ALL EXPOSED PIPENG AT FIXTURES AND EQUIPMENT SHALL BE CHROME _J — — PLATE ESCUTCHEONS AS REQUIRED. L�j EL 13 PERFORM THE FOLLOWING TESTS: A WATER PIPING SHALL BE SUBJECTED TO HIDROSTATIC PRESSURE TEST OF 100 PSG. FOR A PERIOD OF TIME SUFFICIENT TO EXAMINE ENTIRE SYSTEM BUT NOT LESS THAN ONE HOUR. B DRAINAGE PIPING– BEFORE INSTALLATION OF ANY DRAINS, THE ENDS OF 5 V" 3 SYSTEM SHALL BE CAPPED AND ALL LINES FILLED WITH WATER TO m 2x 6 HIGHEST POINT AND ALLOWED TO STAND UNTIL INSPECTION IS MADE AND WATER LEVEL REMAINS CONSTANT. °w C CORRECT ALL DEFECTS DISCLOSED BY ABOVE TEST, D GONN- 411 13 STERILIZE ALL WATER LINES WITH MIXTURE OF (2) TWO POUNDS OF � G I CHLORINATED LIME TO EACH 1000 GALLONS OF WATER (50 PPM OF AVAILABLE CHLORINE). RETAIN MIXTURE IN PIPES 24 HOURS AND FLUSH THOROUGHLY WITH El POTABLE WATER BEFORE PLACING IN SERVICE. 14 COMPLETE SYSTEM, FIXTURES AND EQUIPMENT SHALL BE GIVEN AN IN– w MASTER BEDROOM SERVICE TEST AFTER COMPLETION OF THE INSTALLATION. o 11'2"x14'8" 15 PLUMBING CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL -- PLUMBING WORK SHALL BE FREE FROM DEFECTS OF MATERIALS & WORKMANSHIP L,AV FOR .A PERIOD OF ONE YEAR, FROM DATE OF FINAL ACCEPTANCE, AND THAT HE 2 FU) WILL, AT THIS EXPENSE REPAIR AND REPLACE ALL WORK WICH BECOMES DEFECTIVES DURING GUARANTEE PERIOD. I • • I I 2" VTR SEAT 6i It Y ll' a M. BATH w v- G/fix\ o' (4CFU) SIDt VHOWE U� WH I LAU Y 2w co - - 711H4 D W.L. —_ — — _ °I/2OT u . - - DW Ca IN CEILING RANGE C "L ._ O t BABY'S ROOM BATH E KITCHEN DINING ROOM 9'1"x 12'7" 9'1"x 12'7" 9'1"x 16 - '4" . 0,44 uE SINK 00 , 0 W (0 .0 O U .0 7 O REFRIG, t° CLOSET W � 0 co 2468 2068 0 CLOSET w V J .. v, U CLOSET W L 2468 F I V, LMNG ROOM FAMILY ROOM 9'I"x 12'7" 10'8"x 19'I" Z 0 0 Q 111 Q C r co BEDROOM W p N 10'9'x 12'7" 0) (A N 0 OU) O a. Q� w J O F- tL DRAWN BY: EM CLOSET FOYER CHECKED BY: 5'2"x4'4" 10'6"x4'4" EM ATTACHMENT NO.: .. . . •• � ATT CHMENT Q DRAWING FILE NO.: 20C 1-002 DATE: 3/ /2001 SCALE: NCTED NOTES: 1: SLOPE 2" SAN. LINES 1/4" PER FT. MIN 1.0, SHEET NUMBER: 2: SLOPE 3"& 4" SAN. LINES 1/8" PER FT. MIN PLU MBIRIG FLOOR PLAN! 1��-� 3: PROVIDE ANTI-SCALD VALVE AT TUB EXIST. A/C FLOOR AREA = 1080 S.F. 4: PROVIDE CLEAN-OUT AT BASE OF EACH STACK NEW A/C FLOOR AREA = 719 S.F. S OF F�