01-0468-011 = = Eusebio M. Mora Architect Fla. Lic. # AR0011732 ELECTRICAL NOTES 1. GROUNDED ROMEX or "SMURF" MAY BE USED. 11, CONTRACTOR SHALL INSTALL ALL STARTERS AND CONTROL DE'/ICE:S-FURNISI-�Eb 2. RIGID GALVANIZED STEEL CONDUIT SHALL BE USED WHERE EXPOSED UP TO 4 BY OTHER CRAFTS AND COMPLETE WIRING IN ACCORDANCE WITH 1'1ANUFACTUF;,�ERS FEET AND SUBJECT TO MECHANICAL INJURY OR IN DAMP OR WET LOCATIONS. RECOMMENDATIONS AND APPROVED WIRING DIAGRAMS. ELECTRICAL EQUIPMENT FURNISHED BY OTHERS WILL BE CONNECTED UNDER THIS CONTRACT INCLUDING 3. STEEL RACEWAY INSTALLED UNDERGROUND SHALL BE PAINTED WITH TWO ALL NECESSARY WIRING, CONDUIT, AND FITTINGS. CONTROL WIRINGS—SHALL BE LIND'ER - COATS BITUMASTIC PAINT. THE SUPERVISION OF THE SUS-CONTRACTOR FURNISHING THE EQUIr 11ENT. -__ _ - - - 4. WALL OUTLET BOXES SHALL BE 4" SQUARE. CEILING OUTLET BOXES SHALL BE 4" OCTAGON OR SQUARE. 12. ELECTRICAL WORK SHALL COMPLY WITH ALL APPLICABLE LOCAL OR NATIONAL 5. CONTRACTOR SHALL FURNISH AND INSTALL ALL ELECTRICAL PANELS, WIRING CODES AND WITH THE UTILITY COMPANY REGULATIONS. DEVICES, CONDUIT, WIRING, MISCELLANEOUS SYSTEM, ETC. AS SHOWN ON PLANS 13. PRIOR TO INSTALLATION OF ROUGH ELECTRICAL WIRING CHECK NAMEPLATE OR AS REQUIRED FOR ACOMPLETE ELECTRICAL INSTALLATION. DATA OF AIR CONDITIONING EQUIPMENT, HOT WATER HEATERS, AND OTHER 6. FIXTURES AND LAMPS SHALL BE FURNISHED BY THE OWNER AND INSTALLED BY EQUIPMENT TO OBTAIN CORRECT WIRE SIZES AND OVERCURRENT PROTECTION. THE ELECTRICAL CONTRACTOR, UNLESS NOTED OTHEREWISE, 14. ELECTRICAL INSTALLATION SHALL CONFORMTO REQUIREMENTS OF N.E.C. 110-16(a) 'I. PANELBOARD-ALL CURRENT CARRYING COMPONETS SHALL BE COPPER. SPLIT AND N.E.G. 384-2 FOR PANELBOARDS, INCLUDING SPACES ABOVE THE EQUIPMENT. OR TWIN TYPE BREAKERS ARE NOT ACCEPTABLE. CIRCUIT DIRECTORIES SHALL 15. CONTRACTOR SHALL PREWIRE ALL TELEPHONE OUTLETS WITH 4/C "24 TELEPHONE THE 9780 Southwest 16th Street NUMBERED CONSECUTIVELY ON THE LEFT SIDE TO 50°/16 AND CONTINUED ON CABLE RUN IN PARTITIONS AND DROPPED CEILING FROM INCOMING TELEPHONE Miami, Florida 3 3 1 6 5 THE RIGHT SIDE. JUNCTION BOX. (305) 2 2 9 — 6 8 6 0 8. DISCONNECT SWITCHES SHALL BE GENERAL DUTY, 16. CONTRACTOR SHALL PREWIRE ALL TELEVISION OUTLETS WITH RG58U COAXIAL 9. PROVIDE PULL WIRE IN EACH EMPTY RACEWAY. CABLE RUN IN PARTITIONS AND DROPPED CEILINGS FROM INCOMING CABLE T.V. JUNCTION BOX. fn 10. CONTRACTOR SHALL DO ALL CUTTING, SLEEVING, EXCAVATING AND BACKFILLING W NECESSARY FOR THE INSTALLATION OF HIS EQUIPMENT AND THE PATCHING ELECTRICAL INSTALLATION DESIGNED OF THIS PLAN IS INCOMPLIANCE AS SET THEREAFTER FORTH BY STATE OF FLORIDA STATUTES MODEL ENERGY EFFICIENCY CODES. W 2 U SYMBOL LEGEND g CIL MARK DESCRIPTION MARK DESCRIPTION O DUPLEX RECEPTACLE OUTLET 0 SURFACE MTD.FLOURESCENT 0 SWITCHED RECEPTACLE OUTLET RECESSED MTD.FLOURESCENT LL -� SINGLE RECEPTACLE OUTLET >0< FLOODLIGHTS SURFACE MTD. Q QUADRUPLEX RECEPTACLE OUTLET ® HEAT LAMP t EXHAUST FAN COM50 �V I 11E] Ell 111111 FLOOR DUPLEX RECEPT OUTLET ® ELECTRICAL PANEL U SINGLE SPECIAL PURPOSE OUTLET 'j SINGLE POLE SWITCH J TELEPHONE OUTLET 1 U1P/CFI $3 THREE WAY SWITCH w W 31 J TV TELEVISION OUTLET �jp SINGLE POLE SWITCH W/ DIMMER 5'2ux b'3" MASTER BEDROOM 2 JQ JUNCTION BOX ET DISCONNECT SWITCH 2 1 II'2"x14'8" 0 FAN BOX W/ INCANDESCENT FIXTURE ® EXHAUST FAN \ WALL MTD. INCANDESCENT DOOR BELL M M SURFACE MTD. INCANDESCENT NEW OUTLETS,SWITCHESDETEGT.,ETC. 0 w RECESSED HI - HAT SMOKE DETECTORS TO BH HARDWIRED co t INTERCONNECTED TO NON-SWITCHED 4" SD KITCHEN OR BATHROOM LIGHTING CIRCUITS. 1 1 El W Q 2 0 2 N 2-- 120/240V-10-3WIRE DRESSING 5D ELECTRICAL ELECTRICAL SCHEDULE 150 A BUSH MTD.PANEL 1 CIRCUIT WIRE POLES LOAD(WATTS) GFI 30610 4860 4860 4460 NUMBER SIZE DcSCRIPTION C/B TRIP DEMAND NO.DEM. E SEAT 5D EXISTING LOADS �i 2 PANELRICAL 014 � LIG=HTS / RECEPT. (3W x 1084 SF.) 1P-15 A 3252 cr VP 2 D 012 GFI RECEPTACLES s BATHROOMS 1P_20 q 1000 w D 2 I 2 0 12 SMALL APPLIANCES (2 1500 W) 1P-20 A 3000 M. " 12 DISHWASHER 1P-20 A 1000 p BATH How 012 REFRIGERATOR 1P-20 A 1000 z O • o LAU 012 WASHER � WH 1P-20 A 1500 0 6 DRYER 2P-40 A 5000 010 WATER HEATER 2P-30 A 4000 0 6 I RANGE 2P-50 A 12000 o DW 012 WELL PUMP 1P-20 A 1500 00 �' 8, A/C-2 - A.N.U. W/ 'I.5 KW HEATER 2P-40 A 8100 RANGE # 8 A/C-2 - G.U. a 125510 O 2P-40 A 6200 • '� BABY'S ROOM BATH . KITCHEN DINING ROOM EXISTING LOADS L LL 9'1"x 12'7' O 9T'x 12'7° 9'1"x 16'4" 1-4 014 LIGHTS / RECEPT. (3W x -1145P.) 1P-15 A 2142 `V E OSINK 5 * 12 GFI RECEPTACLES -8 BATHROOMS 1P-20 A 1000 O E Cd TOTAL LOAD 36394 U -W CO 7 Ar O FREFRIG. CLOSET • NON-CONCURRENT LOADS W 0 LOAD CALCULATIONS O �{ � CLOSET FIRST 10,000 W 100% = 10,000 WATTS 28,658 / 240 = 119 AMPS W V, 0 5D 3 3 • • REMAINING 26,394 W 40516 = 10,558 WATTS It C7 A/C LOAD 8,100 W -8 100°116 = 8,100 WATTS W i Cd CLOSET TOTAL LOAD = 20,356 WATTS '^ 0 5D FAMILY ROOM 0 L ,C 1018"x 19'1" 0 4 F 0 M0 � 00 BEDROOM LMNG ROOM Q 3 10'9"x 12'7" 9'1"x 12'7" 3 W 7 0 04 (3)-1/0 THUD (CU) (3)-1/0 THUD (CU) 0 (A N IN 2" CONDUIT IN 2" CONDUIT 00 � 0� 31 TO F.P.L. X-MER a LIGHT POLE 0 150AWf= (L 3 MAIN DISC. CJ w P4 ELECT. EXIST. METER ELECT. CLOSET FOYER PANEL DRAWN BY: 5'2"x4'4" 10'6"x4'4" EMM-0 4 3 15m A LU/ MCB CHECKED BY: Pe-- 4 (2) 5/5" x 10' EMM GROUNDING RODS ATTACHMENT NO.: U1/ (1) # ro (CU) ATTACHMENT# O 3 O IN 3/4" CONDUIT BOND TO COLD DRAWING FILE NO.: wP/CFI 4 4 `r � 4 WATER LINE 2001-002 DATE: 3/2/2001 GROUNDED TO STL. SCALE: REINFORCEMENT a NOTED 6'-011 FOUNDATION t,,,. �C� 01' ��ur•, SHEET NUMBER: " ELECTRICAL FLOOR PLAN 1/4 t EXIST. A/C FLOOR AREA = 1080 S.F. � J• 117 OF NEW A/C FLOOR AREA = 719 S.F. ELECTRICAL RISER N.T.S. r,{ � .