Loading...
01-0468-004 Climate Zones 7 8 9 TABLE 6C-1: PRESCRIPTIVE REQUIREMENTS FOR SMALL ADDITIONS(600 Sq.FL and Less),RENOVATIONS TO EXISTING BUILDINGS AND SITE-INSTALLED COMPONENTS OF MANUFACTURED HOMES. MINIMUM INSULATION MINIMUM INSTALLED COMPONENT INSULATION INSTALLED EQUIPMENT EFFICIENCY EFFICIENCY Concrete R-5 Central A/C-Split SEER = 10.0 SEER = �D.O Frame,2'x 4" R-11 ? Single Pkg. SEER = 9.7 SEER = Frame,2"x 6" R-19 0 Common,Frame R-11 0 Room unit or PTAC EER = 8.5' EER = Common, Masonry R-3 Un Attic R-30 Electric Resistance ANY U) d@L Heat um Split HSPF = 6.8 HSPF = Single Assembly;Enclosed z pump P Z Frame R-19 _,� ¢ Single Pkg. HSPF = 6.6 HSPF = Metal Pans R-13 LU Room unit or PTHP COP = 2.7' HSPF/ _ v Single Assembly;Open R-10 ,_ Common,Frame R-11 ¢ COP rCL„ Gas,natural or propane AFUE = .78 AFUE _ U) Raise d Wood Slab-on-grade No Minimum Fuel Oil AFUE = .78 AFUE _ O Raised R-11 o Raised Concrete R-5 LL Common, Frame R-11 1- w Electric Resistance EF = .88 EF = s� jIn unconditioned space R-6 x° Gas; Natural or L.P. EF = 54 EF = o In conditioned space No minimum Fuel Oil EF = .54 EF = See Table 6-3.6.7 TABLE 6C-2: PRESCRIPTIVE REQUIREMENTS FOR GLASS AREAS IN ADDITIONS ONLY Maximum percentage glass to floor area allowed is selected by type,overhang length,and shading coefficient. Maximum%= Installed%_ GLASS TYPE,OVERHANG,AND SHADING COEFFICIENT REQUIRED FOR GLASS PERCENTAGE ALLOWED UP TO 20% UP TO 30% UP TO 40% UP TO 50% Single Double Single Double Single Double Single Double OH-SC OH-SC OH-SC OH-SC OH-SC OH-SC OH-SC OH-SC 1•-1.0 0'-.90 2"-1 11%.90 3"- 1.0 2'-.90 4•• 1.0 3•-.90 0'-.86 1%.86 0"-.70 2•-.86 1'­70.70 3.-.86 2.-.70 0"-.65 1"-.65 0•-.50 2••.65 1•-.50 0'-.45 1'-.45 0 .40 0'-.35 SHGC or SC may be obtained from the manufacturer. Single clear SC=1.0,double clear SC=.90,and single tint SC=.86. SHGC-.87=SC TABLE 6C-3 I MINIMUM REQUIREMENTS FOR ALL PACKAGES COMPONENTS SECTION I REQUIREMENTS CHECK Exterior Joints&Cracks 606.1 To be caulked,gasketed,weather-stripped or otherwise sealed. Exterior Windows&Doors 606.1 1 Max.0.3 cfm/sq.ft.window area;.5 cfm/sq.ft.door area. Sole&Top Plates 606.1 Sole plates and penetrations through top plates of exterior walls must be sealed. Recessed Lighting 606.1 Type IC rated with no penetrations(two alternatives allowed). Multi-story Houses 606.1 Air barrier on perimeter of floor cavity between floors. A Exhaust Fans 606.1 Exhaust fans vented to unconditioned space shall have dampers,except for combustion devices with integral exhaust ductwork. Combustion 606.1 Combustion space and water heating systems must be provided with outside combustion air. Heating except for direct vent appliances. Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker(electric) or cutoff as must be provided. External or built-in heat trap required. Swimming 612.1 Spas&heated pools must have covers(except solar heated). Non-commercial pools must have a Pools&Spas pump timer.Gas spa&pool heaters must have minimum thermal efficiency of 78%. N Q Hot Water Pipes 612.1 Insulation is required for hot water circulating systems(including heat recovery units). Shower Heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. HVAC Duct 610.1 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically attached, Construction, sealed,insulated and installed in accordance with the criteria of Section 610.1. Ducts in attics must be Insulation&Installation insulated to a minimum of R-6. Air handlers shall not be installed in attics unless in mechanical closets. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. GENERAL DIRECTIONS: 1. On Table 6C-1 indicate the R-value of the insulation being added to each component and the efficiency levels of the equipment being installed.All R-values and efficiencies installed must meet or exceed the minimum values listed.Components and equipment neither being added nor renovated may be left blank. 2. ADDITIONS ONLY. Determine the percentage of new glass to conditioned floor area in the addition as follows.Total the areas of all glass windows,sliding glass doors and glass door panels. Double the area of all non- vertical roof glass and add it to the previous total. When glass in existing exterior walls is being removed or enclosed by the addition,an amount equal to the total area of this glass may be subtracted from the total glass area. Divide the adjusted glass area total by the conditioned floor area of the addition.Multiply by 100 to get the percent.Find the largest glass percentage under which your calculated percentage falls on Table 6C-2.Prescrc:ives G are given by the type of glass(Single or Double pane)and the overhang(OH)paired with a shading coefficient(SC). For a given glass type and overhang,the minimum shading coefficient allowed is specified. Actual class windows and doors previously in the exterior walls of the house and being reinstalled in the addition do not have to comply with the overhang and shading coefficient requirements on Table 6C-2.All new eiass in the aaortion nust meet the requirement for one of the options in the glass percentage category you indicated.The overhang(OH)distance is measured per;e^c:cularly from the lace of the glass to a point direay urger the outermost edge of me overhang. _ 3. RENOVATIONS ONLY. Replacement glass needs to meet the following requirements. Any glass type and shading coefficient may be used for glass areas which are under at least a two loot ovemang and wnose lowest ° edge does not extend further than 8 feel from the overhang. Glass areas being renovated that do not meet this criteria must be either single-pane unled,double-pane Gear or double-pane timed. BUILDING SYSTEMS.Comply when new system is installed for system installed. Complete the information requested on the lop half of page 1. Read-Minimum Requirements for Small Additions and Renovations',Table 6C-3,and check all applicable items. Read,sign and date the-Owner/Agent'certification statement on page 1. -2-