01-0696-004 Climate Zones 7 8
`ABLE MI.: PRESCRIPTIVE REQUIREMENTS FOR SMALL ADDITIONS(600 Sq.FL and Less),RENOVATIONS TO EXISTING BUILDINGS AND SiTE-INSTALLED COMPONENTS OF MANUFACTURED HOME:
MINIMUM - t - INSULATIOY MINIMUM INSTALLED
COMPONENT INSULATION: -"'NSTALL°_D y E-QUIPMENT EFFICIENCY EFFICIENCY
Concrete R-5 U" cl ` General A/C-Split SEER = 10.0 SEER =
U) Frame,2'x 4' R-11 -Single Pkg. SEER = 9.7 SEER = _
a Frame,2'x 6' R-12 g .Pcom unit or PTAC EER = 8.5' EER =
3 Common,Frame R-11'
Common,Masonry R 3 Electric Resistance ANY
0 Under Attic R-30 ► b z `Pleat pomp-Split HSPF = 6.8 HSPF =
z Single Assembly;enclosed R-19 Single Pkg. HSPF = 6.6 HSPF =
U Single Assembly;Opened R-10 r x Room unit or PTHP COP = 2.7' HSPF/ _
Common,Frame R-11 W COP
�
9 Slab-on rade No Minimum
n Gas,natural or propane AFUE = 78 AFUE _
Raised Wood R-11
• Raised Concrete R-5 _ Fuel Oil AFUE = 78 AFUE _
LL Common,Frame R-11
W Electric Resistance EF = 88 EF =
U In unconditioned space R-6 = Gas; Natural or L.P. EF = .54 EF =
o In conditioned space No minimum Fuel Oil EF = 54 EF =
See Table 6.3,6.7
TABLE 6C-2: PRESCRIPTIVE REQUIREMENTS FOR GLASS AREAS IN ADDITIONS ONLY
Maximum percentage glass to floor area allowed is selected by type,overhang length,and shading coefficient. Maximum%_ Installed%= r
GLASS TYPE,OVERHANG,AND SHADING COEFFICIENT REQUIRED FOR GLASS PERCENTAGE ALLOWED
PTO 20% UP TO 30% UP TO 40% UP TO 50%
Single Double Single Double Single Double Single Double
O -SC OH-SC OH-SC OH-SC OH-SC OH-SC OH-SC OH-SC
1'-1.0 O'_.90 2'-1.0 1'-.90 37-1.0 2'-.90 4'-1.0 3'-.90
0'-.86 1'-.86 0'-.70 2'-.86 1'-.70 3'-.86 2'-.70
0'-.65 1'-.65 0 .50 2'-.65 1'-.50
0'-.45 1'-.45 0'-.40
0'-.35
Shading coefficients(SC)may be obtained from the manufacturer. Single clear SC=1.0,double clear SC=.90,and single tint SC=.86.
TABLE 6C-3 I MINIMUM REQUIREMENTS FOR ALL PACKAGES I
COMPONENTS SECTION REQUIREMENTS CHECK
Exterior Joints&Cracks 606.1 To be caulked,gasketed,weather-stripped or otherwise seated.
Interior Joints&Cracks 606.1 All openings in interior surfaces of ceilings and exterior walls must be sealed.
Sole&Top Plates 606.1 Sole plates and penetrations th-rough t -rough top plates of exterior was must-be sealed.
Infiltration Barrier 606.1 Infiltration barrier must be Installed in exterior walls&raised wood floors.
Fireplaces 606.1 Fireplaces must have flue dampers,glass doors and outside combustion air intakes.
Exhaust Fans 606.1 Exhaust fans vented to unconditioned space shalt have dampers,except for combustion
devices with integral exhaust ductwork.
Combustion 606.1 Combustion space and water heating systems must be provided with outside combustion air,
Heating except for direct vent appliances.
Water Heaters 612.1 Comply with efficiency requirements in Table 6-11. Switch or clearly marked circuit breaker(electric)
or cutoff(gas)must be provided. External or built-in heat trap required.
Swimming 612.1 Spas&heated pools must have covers(except solar heated). Non-commercial pools must have a
Pools&Spas pump timer.Gas spa&pool heaters must have minimum thermal efficiency of 78%.
Hot Water Pipes 612.1 Insulation is required for hot watercirculating systems,(including heat recovery units)and the first
8'of piping from the water heater(or until piping enters an insulated wall or slab).
Shower Heads 612.1 Water flow must be restricted to no more than 3 gallons per minute at 80 PSIG.
HVAC Duct 610.1 All ducts,fittings,mechanical equipment and plenum chambers shall be mechanically attached,
Construction, sealed,insulated and installed in accordance with the criteria of Section 610.1. Ducts in attics must be
Insulation&Installation insulated to a minimum of R-6. Air handlers shall not be installed in attics unless in mechanical closets.
HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system.,,,,,' i y r
GENERAL DIRECTIONS:
1. On Table 6C 1 Indicate the R-value of the insulation being added to each component and the efficiency levels of the equipment being installed.All R-vahres and effidenpies igstatled must meet coed the rrinimum,values
listed.Components and equipment neither being added nor renovated may be left blank. '; , ." (�) ' r.
2. ADDITIONS ONLY.Determine the percentage of new glass to conditioned floor area In the addition as follows.Total the areas of all glass windows,sliding glass doors%r4'0ass dooi f anet a the area of all non-
vertical roof glass and add it to the previous total.when glass in existing exterior wall is being removed or enclosed by the addition,an amount equal to the total area of,d s glass may b the(otai glass area
Divide the adjusted glass area total by the conditioned floor area d the addition.Mulfipy by 100 to gel the percent.Fmd the largest glass percentage under which your caladated�percenta falls 6C-3.Pr,�iptives
are given by the type of glass(Single or Double pane)and the ovedrarng(Oft)paired with a shading coefficient(SC).For a given glass type and ovefiang,the minimum shaduigcoefficient ow i ed. glass
windows and doors previously in the exterior walls of the house and being reinstalled in the addition.do not have to comply with the overhang and shading coefficient requirements'9 Table pddton
must meet the requirement for one of the options in the glass percentage category you Indicated.The overhang(OM distance is measured perpendicularly from the face of the gtas§tn3 point c. st edge
of the overharhg. t h
3. RENOVATIONS ONLY.Replacement glass needs to meet the following requirements.Any glass type and shading coefficient may be used for glass areas which are under at least a two i t ' and Am lowest
edge does not extend further than 8 feet from the overhang.Glass areas being renovated that do not meet this criteria must be either single-pane tinted,double-pane cloaca double-pane lint
4. Complete the information requested on the top half of page 1.
5. Read"Minimum Requirements for Small Additions and Renovallone,Table 6C-3,and check all applicable Items.
6. Read,sign and date the'Owner/Agent'certification statement on page 1.
i