Loading...
01-0517-028 1 J. Bonfill & Associates r- -i CU#2 Cup 00 1n M I I r - - - - - - - - - - --a U 4-5 u a\ O 0 I • � � Cn o � REFRIGERANT LINES I O M A/C #1 : UNDER SLAB I N 3 TON COMPRESSOR (12.0 SEER) GUEST ROOM YORK HRC036S06 A.H.U. RP036N06 EXHAUST NOTES _ (1 50 CFM) � ALL EXHAUST DUCTS SHALL BE CONSTRUCTED OF SHEET METAL, TERMINATE OUTSIDE THE BUILDING, AND TERRACE GARAGE I BE EQUIPPED WITH A BACKDRAFT DAMPER. d DUCTS FROM TOILET ROOMS SHALL DISCHARGE TO THE OUTSIDE OF THE BUILDING, SHALL BE TERMINATED ��, ' .O = FAMILY ROOM �- — — — — — — NOT LESS THAN 6 INCHES ABOVE THE FINISHED ROOF SURFACE, AND SHALL BE SCREENED WITH A CORROSION �? RESISTANT MATERIAL HAVING A MESH SIZE NOT LARGER THAN 1/2". PROVIDE GOOSE NECK OR RAIN CAP ON `n — — — — — — ROOF TERMNINATIONS. 0 •� 1:7'MM U CLOTHES DRYER EXHAUST DUCT SHALL NOT BE SCREENED F-+-i ''-4 ti CLHOTHES DRYERS EXHAUST DUCTS OR VENTS SHALL COMPLY WITH MANUFACTURER'S INSTALLATION 200 CFM INSTRUCTIONS, BE CONSTRUCTED OF A MINIMUM 26 GAUGE METAL PIPE, HAVING A SMOOTH INTERIOR GRILLE 6x6 I SURFACE WITH JOINTS RUNNING IN THE DIRECTION OF THE AIR FLOW. DUCT JOINTS SHALL NOT BE ASSEMBLED WITH SHEET METAL SCREWS OR OTHER FASTENERS WHICH WOULD EXTEND INTO THE DUCT. 2" COND. LINE TO DRAIN OUTSIDE 80 I 100 CFM I I I =EF 0 6" ABOVE GRADE 7� GRILLE 6x6 I I I CEILING EXHAUST FAN 50 CFM BRIOAN 670 OR EQUAL. 4 DIA. EXHAUST DUCT UP TO ROOF I I I I TERMINATE CAP 6" MIN. ABOVE ROOF PROVIDE BACKDRAFT DAMPER. 6x24 6x8 AH#1 6x9 LAUNDRY 70 F I BUILT-IN FULL OHE CABINETS ° I 100 CFM 40 GRILLE 6x6 LQJ wHl KITCHEN LEGEND: 50 CFM REFRIGERA L NES GRILLE 6x6 6x20 UNDER SL y 4� T T T a E.F. EXHAUST FAN 0 QO 150 CFM 150 CFM 150 CFM CEILING DIFFUSER CFM GRILLE 6x12 GRILLE 6x12 GRILLE 6x12 VENTLESS HOOD 00 CFM ❑ JG CFM RIGID DUCT GRILLE 6x6 6x20 U P 6x6 6x18 6x6 6x15 6x6 6x1 OVEN GR LE 6 os POSAL D N LE 6x6 FLEXIBLE DUCT on po &5X6 - 5x6 - QT THERMOSTAT ` - - - - - - - - - - - 6x8 0 / REFRIGERANT LINES./ I I - - } i I TO LOWER FLOOR 2" COND. LINES TO DRAIN N 1 OUTSIDE 0 6" ABOVE GRADE l/) - � - / LOB B Y 100 CFM 6�b \ NOTE: GRILLE x10 I LIVING I ; < I DINING DUCT INSULAT10N TO BE R-6 A/C SCHEDULE (YORK SPLIT SYSTEM RESIDENTIAL) AIR HANDLER _ - COOLING CAP. CONDENSER UNIT TONS SEER COND. UNIT AIR HANDLER HEATER CFM ^� (MBTUH) COMPRES'R FAN MTR DIMENSION WT. BR.CIRC. REF. LINES DIMENSIONS FAN MTR WT. MODEL NUM. MODEL NUM. TOTAL/SENSIBLE FLA/LRA HP/LRA H-W-D LBS. AMPS. LIO.-SUCT. H-W-D HP/LRA LBS. rS �. - W w 1 3.0 12.0 HDH036S06 FRP036N06 2HK06501006 1250 34.4 - 25.5 14.7/81.0 1/5/1.3 27x37x27 157 19.7-30 3/8 - 3/4 40x21.5x22 1/2/3.3 115 > 2 3.0 12.0 HDHO36SO6 FRPO36NO6 2HKO6501006 1250 34.4 - 25.5 14.7/81.0 1/5/1.3 27x37x27 157 19.7-30 3/8 - 3/4 40x21.5x22 1/2/3.3 115 ENTRY O 9 3 2.0 12.5 HDH024SO6 FRP03ON06 2HKO6500506 800 24.4 - 18.1 9.3-57.0 1/8-0.8 36-1/8X24X24 157 12.4-20 3/8 - 5/8 40x18x22 1/3 -2.5 105 W V O 00 REVISIONS BY i FI P5f F�00F PLAN - 5ANIfAPY 5�MP,, -- �0011�pINT; 3,135,33 SQ,�T, C 29,99%) . 0 Date: 01-29-2001 UNC�p A/C; 2,33039 SQ,�1", °' '' '' �' q' -- -- -- 6II,IJ I I I I I I I I I I Job: ESTAREL•LAS Drawn: J.P.R.S. Checked: I Scale: AS SHOWN SHEET -y `V OF 2 9