00-0044-029 H.V.A.C. NOTES HVAC DESIGN REOUIRES: YES NO ALL WORK SHALL CONFORM WITH THE STANDARD BUILDING CODE AND ALL OTHER APPLICABLE STATE AND LOCAL DUCT SMOKE FIRE DAMPM(S) X ISSUANCE FOR CONTRACTOR SHALL WARRANT ALL WORK TO BE FREE OF DEFECTS IN WORKMANSHIP AND MATERIALS FOR A PERIOD DAMPER(S) BALANCE ALL SYSTEMS TO PROVIDE AIR QUANTITIES AND CAPACITIES AS INDICATED OR AS REQUIRED BY CODE BIDDING SET ONLY ALL WORK SHALL BE FIELD CHECKED BEFORE INSTALLATION AND COORDINATED WUTH ALL TRADES. ME FMTM ROOF CELING ASSBELY X CONSTRUCTION SET ONLY DUCTWORK SHALL BE CLASS 1 GLASS FIBER DUCTBOARD IN ACCORDANCE WITH S.M.A.C.N.A.'S FIBROUS DUCT STOPPM X a ®BUILDING PERMIT SET 6NL' -'� PROVIDE VOLUME DAMPERS TURNING VANES, ETC., IN DUCTWORK FOR PROPER AIR FLOW AND BALANCE. PROVIDE REV1 " MULTIPLE VANE EXTRACTORS WITH CONTROL RODS AT ALL OUTLETS CONNECTED CLOSER THAN TWO DUCT DIAMETERS 23 REV2 REVS FLEXIBLE DUCTS IF USED SHALL BE THE INSULATED TYPE(MIN. R-6) SUPPORTED AND INSTALLED TO AVOID SAGS AND q KINKS. ALL FLEXIBLE DUCTS SHALL BE SIMILAR IN LENGTH TO AVOID DISSIMILAR PRESSURE DROPS AND THE LONGEST s REFRIGERANT PIPING SHALL BE SEEMLESS COPPER TYPE "L°' HARD OR SOFT DRAWN OR ACR CAPPER TUBING WITH WROUGHT COPPER SOLDER JOINT FITTINGS. SOLDER SHALL BE 95/5 APPLIED WITH SUITABLE FLUX. INSULATE REFRIGERANT SUCTION PIPING WITH 3/4- ARMAFLEX PREMOLDED PIPE INSULATION PROVIDE A/C UNITS WITH MATCHING HEAT — COOL THERMOSTATS WITH ON — OFF AUTO SUB — BASE SWITCH, _ PROVIDE ALL NECESSARY INSTRUCTIONS TO THE OWNER FOR OPERATION OF THE SYSTEM INCLUDING OPERATING AMX SEAL HERE PROVIDE ALL NECESSARY SLEEVES BEFORE CONCRETE IS POURED AND COORDINATE PLANS AND LOCATION OF DUCTS WITH TRUSS MANU. AND ARCHITECT PRIOR TO COMMENCING WITH THE WORK. IF CONFLICT ARISES AND NOTIFICATION WAS NOT DONE IT SHALL BE THE RESPONSIBILITY OF THE A/C CONTRACTOR TO FIND A SOLUTION THE HOUSE MUST COMPLY WITH ALL PRESCRIPTIVE REQUIREMENTS FOR WINDOW, DOOR AND DUCTWORK INFILTRATION AND INCLUDE THE FOLLOWING REQUIREMENTS: WINDOWS SHALL HAVE A MAXIMUM OF 0.5 CFM PER LINEAR FOOT OF OPERABLE SASH CRACK DOORS INCLUDING SL.GL.DRS. SHALL HAVE A MAX. OF 0.5 CFM PER SQ. FT. OF DOOR AREA EXTERIOR JOINTS OR OPENINGS IN THE BUILDING ENVELOPE SHALL BE CAULKED GASKETED WEATHERSTRIPPED OR OTHERWISE SEALED IN AN APPROVED MANNER H.V.A.C. DUCTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH INDUSTRY STANDARDS AND THE LOCAL MECHANICAL ALL JOINTS IN DUCTWORK IN UNCONDITIONED SPACES SHALL BE SEALED 5& HB ALL EXHAUST FANS VENTED TO EXTERIOR OR UNCONDITIONED SPACE SHALL HAVE DAMPERS ALL PENETRATIONS, JOINTS AND CRACKS IN INTERIOR SURFACES OF CEILINGS AND EXTERIOR WALLS SHALL BE INCLUDING THE FOLLOWING COMPONENTS; WINDOW AND DOOR FRAMES, ELECTRICAL OUTLETS, BASEBOARDS, ATTIC ACCESSES, AND RECESSED LIGHTING CANS °— THESE PLANS WERE PREPARED TO COMPLY WITH THE BUILDING ENVELOPE ENERGY REQUIREMENTS OF THE FLORIDA MODEL ENERGY CODE PRESCRIPTIVE 2. INSULATION VALUES ARE AS NOTED ON PLANS. REAKF4�T 15 CFM I g SPLIT S%1fflrSTEM SCHEDULE IOx6 I I IOX6 611� FLEX FAMILY ROOM MANUFACTURER 2 w HE 200 CFM a 1 6 6"p FLEX CONDENSING UNIT MODEL - 42JAZ 8"0 FLEX r,rf,l I I a . AIR HANDLIER UNIT MODEL CHA-40A] 124 FLEX �/ I • • VOLTAGE 2 I e _ CFM. HIGH 1,400 200 CRI I 7 FLEX I KITCHEN I Z 103 t 8 FLEX 1 8 I I ( 2 D I 64 F X \ °° I TOTAL .T.U.'S 3<31500 14"0 FLEX 84 FLEX ! ! I /\ DRAIN I c> _ SENSIBLE .T.U.°S 20,200 i I I LATENT .T.U.°S 11,300 . . 6'10 FLE --- MAXIMUM K LU. HEAT 125KUJ r t i — — -- � �` � • ------------- J4T. STATIG SSU 0 3 ' 811 FLEX .. ---^" W PROVIDE XH. 61°0 FLEX 'Z THERMOSTAT MODEL T-8340 4" � 0 --� � ° °" —-- ——— —— — o p4 U � LIQUID/SUCTION SIZE-IN 3!S°° _ �f8°° F EXTERI - 71 FLEX —__ _ O ammimmommum 70 G I o ®� i 6 °� LINES: E.P. FAN MOTOR FLA 20 _ ` ► IOx 1 6 1°°m FLEX 50 G _ _ _ 150 I I _ 3/8 LIQUID � ROVIDE XH. ff ---- -------- lox I x61 I I I PROVIDE E -- 3/4" SUCTION MAIN FUSE CMIN,1 30/30 FAN QT ( —* I I I FAN QT-80 `"— - DISC. MIN. CIRCUIT AMPACITY AMPS. 30/30 t °'� FLEX 6'° FLEX I I VENT. '° — -_ -- 11 �} ELECT. -------------- i �� I I I I r.):F--OM3 -- °° - — _ METER 100G �_ ®� I CD oo Tr 100 CFM —0,0 1 100 CFM 16 10x6 16 6 , BEDROOM #3 61 BEDROOM 4 COVERED BEDROOM #2 It ______ __ _ ___ ____ __ _ _ _ CDM 6t 1 i I I e t I I t I Oj � n t i -n CONDENSING 58 w 4-j UNIT t a Pa & CONTROL • CONNECTIONS Q ° 5 Lum cz) 'T Q a vi -`�' ° MECHANICAL PLAN Lu CONCRETE BASE ;:YF... �� ,: (NOSUILDATIQNE W/0 Ld Cu , . /64-10/10 W wF 4» o Scli 40 lit I 0000000 Q P.V.C. PIPE _ COND. UNIT TO BE SECURED TO CONC. SLAB CD CU z I /(6) 1-1/2' REMINGTON :iZ PO FASTENERS CD I TO WITHSTAND 110 M.P.H. WINDS --j SUCTION LINES J � x c, CONDENSING UNIT MOUNTING DETAIL _ CD C--- �. :. C-3 of L, .t:, ro c 0j cn M - a