00-0044-019 w_
ISSUANCE R
SQUARE FOOTAGE CALCULA11ONS BIDDING SET ONLY
KEY NOTES DOOR SCHEDULE
PROVIDE 15 REINFORCEMENT BAR AT ALL CORNERS, ADJACENT TO ALL OPENINGS AND SPACED FIRST FLOOR LIVING AREA: 2,187 SQ. FT. CONSTRUCTION ONLY
1 Door Quantity WT, HT. THK. MATERIAL TYPE THRESHOLD WEATHER STRIP HARDWARE LOCK FIRE RATING ROUGH OPENING REMARKS
AT A MAXIMUM OF 72 ON CENTER ELSEWHERE (SEE ENGINEERING CALCULATIONS COVERED ENTRY : 126.74 SO. F . 1 1 (2}2`_g" g'_0" 1-3/8" MTL CLA SWING MTL. Y EXT. KEY L DEADBOLT - DBL BUILDING PERMIT SET ONLY
2 TIE BEAM ABOVE SEE ROOF OR FRAMING PLAN FOR SIZE AND REINFORCEMENT GARAGE: 363.2 SQ. FT. 2 1 2'-8" 6'-8" 1-3/8" MTL. CLA SWING MTL. Y DEADBOLT - -
7 EGRESS TYPE WINDOWS SHALL BE OPERABLE FROM THE WITHOUT THE USE OF TOOLS AND TERRACE : 0 3 4 2'-8" 6'-8" 1-3/8- WOOD H.0 SWING - - - - - - REV2
PROVIDE A CLEAR OPENING OF NOT LESS THAN 20"x24 n IN HGT. AND 5.7 SQ. FT. IN AREA, THE TOTAL BUILDING AREA : 2,676.9 SO. FT. 4 1 (2)2'-6" 6'-8" 1-3/$" WOOD H.0 SWING - - - - - - RLy3
BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44" FROM THE FIN. . LEVEL NOR SHALL » „ „ 9
ANY PART OF THE OPERATING MECHANISM BE PLACED HIGHER THAN 54" FROM THE FIN. FLR.. SEE 5 2 2'-6- 6-8 1-3/$ WOOD H.0 SWING
N.F.P.A. 101, 21-2,2.3 (C) 6 1 $'-0" 6'-8" 1-3/$" ALUM./GL SLIDING MTL. Y
g 7 1 9'-0" 6°-8" 1-3/8- ALUM. GL SLIDING MTL. Y
ALL WINDOWS SHALL BE COLONIAL AND THE FRAME SHALL BE E.S.P. (COLOR WHITE) _
10 8 2 2'-0" 6°-$" 1-3/8" WOOD BIFOLD
1/2 ROUND ARCH WINDOW ABOVE SEE ELEV. SHT.
1
9 2 2'-6" 6'-8" 1-3/8" WOOD BIFOLD
11 ELLIPTICAL ARCH WINDOW ABOVE SEE ELEV. SHT 10 3 5'-0" 6'-8" 1-3/8" WOOD SLIDING - - - - - -
11 1 5'-0" 6'-8" 1-3/8- WOOD BIFOLD AFFIX SEAL HERE
- - _ _ _ _
12 TRANSOM WINDOW ABOVE SEE ELEV. SHT. 12 1 8'-0" 8'-0" 1-3/4" MTL CLA OVRHD MTL. Y EXT.LATCH - GARAGE �
NUMBERS OF ADDRESS SHALL BE VISIBLE AND LEGIBLE FROM THE STREET FRONTING THE LL TOTAL 20
13 PROPERTY AND SHALL BE A MIN. OF 3 IN HGT.
14 ENTRY PORCH AREAS OR TERRACES SHALL BE CLAD WITH 5/8" STUCCO FINISH ON METAL LATH OVER
ONE LAYER OF 301b. FELT PAPER OVER 1/2" C.D.X. PLYWOOD NAILED AT 4" ON CENTER TO TRUSSES. Li
USE 10d NAILS
i6 ALUMINUM GUTTER AND DOWNSPOUTS. PROVIDE CONC. SPLASH BLOCK AT ALL DOWNSPOUTS
22 20"x22" KNEE SPACE AT BATHROOM CABINET
25 30" HGT. BATHROOM MICA CABINET WITH 4" TOE SPACE , „ Ff
69'-10"
26 PROVIDE FULL LENGTH MIRROR ABOVE BATHROOM CABINET WITH BEVELED EDGE FINISH
5806 63'-10" 6'-0" «
27 BATHROOM FLOORS SHALL BE OF IMPERVIOUS MATERIAL
29 EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED TO PERMIT THE OPENING OF THE E5
LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY SEE NFPA. 101, SECT. 21-2.4.4. '_ » _ " n » n n 4 n » n
2 10 8-7 8-10 5-3 8-4 9-7 9- 7-6 3-7
30 SAFETY GLASS CATEGORY "2' AT ALL GLAZING WITHIN 60" ABOVE FINISHED FLOOR AT RR 44 33 5$ HB II- - -
TUB AND SHOWER SEE N.F.P.A. 101, 21-2.4.4 1 OBSCUR D-1 TC ¢ TC _ TG _ ;� TG �I «a HR 4 0 00 00
31 WINDOW SHALL HAVE OBSCURED GLASS SAF. GL CAT, I! R 4040' R 404
( F5
32 FURRED OUT DRYWALL WALL 3" FOR PLUMBING STACK 7 77 CI -
33 ALL PLUMBING FIXTURES MUST COMPLY WITH WATER CONSERVATION ORDINANCE No.91-15 1g A TER EDROO 3&4 - �
DRYWALL PARTITION BENEATH CABINET COUNTERTOP 34 1/2- HGT. ;'\ 1 IR E A K C f't T - -
cv
40 DRYWALL PARTITION ( 7`-6" HGT.) WITH WD. STUDS SPACED 12" O.C. PROVIDE MID HGT. {{ m i° �'- F-----�� -`� i I {) i I AONNk
ROW OF 2x WD. BLOCKING 24--
¢ ! { -
41 39 CLEAR SPACE FOR FUTURE REFRIGERATOR II { +------- -- { o EA L�r R M - --v m « a
® 26 29 s ,___ _ r-__--__, i I i Q
42 PROVIDE FULL MICA BACKSPLASH AT KITCHEN CABINETS 27 30 I I I { II °
» , , f » a t 64 pl " t 9 » p n n a n s ri Y n a » n Z
8 - 3 -1 I I 0 I r0 a 4 14-0 4 14-2 4-5 2 5-8 8 w
44 PROVIDE SLIDE-IN ELECTRIC RANGE, OVEN, MICROWAVE COMBINATION UNIT
45 PROVIDE SELF CIRCULATING EXHAUST HOOD ABOVE RANGE �`�\ I I F I LIVING ROOM
46 PROVIDE DOUBLE SINK WITH STAINLESS STEEL FINISH WITH GARBAGE DISPOSAL
n n KI AT WALL I I � --�\ I I �> ®®� � ,� o I I { X
47 12 WIDE BY 30 HGT. KITCHEN CABINETS PROVIDE 2x BACKING LL _
51 PANTRY WITH 5 EQUALLY SPACED SHELVES IN DRYWALL FINISH
52 ELECTRIC METER MAIN DISCONNECT II I �,, { - K N I
53 DRYER VENT SHALL NOT EXCEED MANUFACTURER'S RECOMMENDATION AND/OR 25' L __________u {{ ° { I -� "' I %\ 41 4� 6
AIR CONDITIONER COMPRESSOR SEE MECH. PLAN FOR TYPE. COMPRESSOR SHALL BE r I I ¢ I I 42 8 --
54 BOLTED TO 42"x42" CONCRETE PAD WITH 6 REMINGTON POWER ACTUATED FASTENERS. i I I { [�
COMPRESSOR SHALL BE INSTALLED AT FL LEVEL SEE SITE PLAN FOR HGT, REQUIRED i W.1 .O. { { ® 117 p D1�
n A » n 5-3" n e n n p n » I " n » q. » f » » 5-2"" n A n n ® »
55 COMPRESSOR MAIN DISSCONNECT SHALL BE INSTALLED AT A MIN. SEPARATION OF 18" 8 ° 7-9 I 4 0 4 5-2 4 2-6 f 4 0 6-10 8 6'-6 0 $ 4 6 4 4 3-2 4 -0 $ '~
I p
56 ELECTRICAL SERVICE PANEL AT 60" ABOVE FINISH FLOOR `i' I-------------- 11 i N - -- I I , °Q 55
pq- ® -
57 ELECTRICAL METER SHALL BE INSTALLED 48" BEHIND FRONT WALL II
CQ
_ b-
5g PROVIDE HOSE BIBB SEE DETAIL ON PLUMBING SHT {{ "` _ gg - - -
❑ - -�`
59 ELECTRIC WASHER MIN. REQUIRED CLEAR DEPTH IS 30" IN CLOSET fi °r --- _ F7-4-11 �, _ ►�
n » 27 25 - 5 ym �, 1 1 27 25 �, 1 E.P.
60 ELECTRIC DRYER MIN. REQUIRED CLEAR DEPTH IS 30 IN CLOSET PROVIDE 6 WALL BEHIND 29 26 i ______________ �, I I I I 29 26 "c II
FOR DRYER VENT 30 $ # �I I 30 MAIN
PROVIDE 66 GALLON WATER HEATER WITH A ENERGY FACTOR OF .87 SEE ENERGY CALC. N FOYER I I I I DISC. 57
61 PROVIDE HEAT TRAP AND STUB OUT FOR FUTURE SOLAR OR H.R.U. 10 I � DINING 1 FAN . I I {�1,ELECT. 52
RECESS ELECTRICAL OUTLETS AND SWITCH BOXES IN ONE HOUR FIRE RATED PARTITION F _ 1 1 F.F.E. -0.883 L tY METER
63 SHALL BE METALLIC WITH A SURFACE NOT TO EXCEED 16 SQ. IN. AND THE SURFACE AREA ------°�-___-- 11 8 N1
OF THE BOXES SHALL NOT EXCEED 100 SQ. IN. PER 100 SQ. FT. OF WALL SURFACE
BOXES LOCATED ON OPPOSITE SIDE OF PARTITION SHALL BE SPACED 24" APART OF ( 3 GARAGE HB
HORIZONTAL DISTANCE 10 �.�/ 64 ® -----/ `' 108 {I 58
64 ALL APPLIANCES AND CARPETS SHALL BE INSTALLED AT THE TIME OF CLOSING 8" 5'-10" 4>i I a_ 4 3'-1" 4 2'- 1'-7" 4" 5'-10" 8" 6'-6" 8" 8'-4n 3'-4" 4" 5'-2" 4" 3'-2" 4" II 1$'-0" 8"
22"00" METAL CLAD PLYWOOD CEILING SCUTTLE. THE SCUTTLE SHALL BE PROTECTED ON fi 75
66 GARAGE SIDE WITH NOT LESS THAN 25 GAUGE SHEET METAL SEE DTL No. 18 SHT. D-1 UC TG HR 050 _ GIRDER USS II c,9,91 m
68 LINEN CLOSET PROVIDE 5 EQUALLY SPACED WIRE SHELVES 12" DEEP - ® T a �� TEEL 74 -- - 78 II �
COVERED
71 SEE DETAIL No. 8 SHT, No. D-1 FOR METAL STUD PARTITION DETAIL 64 c, BEDROOM 2 � - __ _� F 64 N CQLUM �� ��� - H- � .- - -- - - -- -- .�
72 PROVIDE 12" WIDE WIRE SHELF SHELF 72" ABOVE FIN. FLR. -
4, -- -- - —� 10 I !I I
74 ONE HOUR FIRE RATED WALL WITH 5/8- TYPE x" DRYWALL ON METAL STUDS 24 O.C. 2 ¢ # I II
n > n » r » » e n r » e » n r j » n a n n O I #
W.P. 1200 FROM THE DESIGN MANUAL OF THE GYPSUM ASSOCIATION SEE DTL No. 9 SHT. D-1 8 11 -2 10-2 8 6-6 4-6 3-10 8 2 4 10-Q ripnFp
c' z 75 ONE HOUR FIRE RATED CEILING WITH 5 $ TYPE "x" DRYWALL QN 1x3 FURR. STRIPS AT SS `�
16" O.C. AND 3.5" BAIT INSULATION S E DETAIL No, 10 SHT. D-1 ® � -®� ®- -" -° -° -- C-1 Z ' - ___ �__ --- �-° °® °-® -- �_� -__ -- _
v 76 POST DANGER SIGN IN GARAGE TO READ: DANGER DO NOT OPERATE ENGINES WITH DOOR
cn CLOSED CARBON MONOXIDE EMISSION IS LETHAL. THIS SIGN SHALL HAVE 1/2 HGT. To lull
HR 4050
._m LETTERS. 7 B _ ca
77 2x6 P.T. WOOD PLATE WITH 1/2" DIA. ANCHOR BOLTS SEE DET. No. SHT. No. 5$ ! 2 ° ' 7 I I
a - I 12
60 SQ. IN. SCREENED VENT BETWEEN GARAGE FLOOR LEVEL AND NO HIGHER THAN 7 i- HR 4050 HR 4050 oa
a 78 ABOVE GARAGE FLOOR LEVEL. PROVIDE 1 VENT PER EVERY 8' WIDTH OF GARAGE DOOR r #
o i EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPERATE THE DOOR
79 FROM THE INSIDE OF THE CLOSET SEE NFPA. 101 SECT. 21-2.4.3. 2
CENTERLINE OF GIRDER TRUSS ABOVE SEE ROOF PLAN OR FRAMING PLAN. PROVIDE A
4 80 � A n » R » r n r n ' » f n e n r n e n
°, MIN. 2 FILLED CELLS AT ALL GIRDER TRUSSES 6-3 6'-3 4-7 4-7 -4 6-6 -4 6"-4' 6-4 6-4 1 -8 00 16'-0" 1 -8
C-1 83 PROVIDE 1x2 FURRING STRIPS 24 ON CENTER WITH ONE CUT NAIL EVERY OTHER COURSE -1 "
OF MASONRY WALL. 12'-6" 10'-6" 14'-10" $ 12'-8" 19'-4"
cn 86 16" WIDE WIRE SHELF ABOVE WASHER/DRYER
89 1/2" DRYWALL WALLBOARD FINISHED AND PAINTED WITH 2 COATS LATEX WALL PAINT 69'-10"
® C' g4 CLOSER "C" LABEL DOOR RABETTED JAMB SEE DOOR SCHEDULE «a
CD
CD
a 95 13" X 24" MEDICINE CABINET 60" ABOVE FINISH FLOOR m MESH
0-
g7 ELECTRIC DISHWASHER BY OTHERS
fm cu R PLAIN aaaaaaaa
99 EXPOSED KEYED MASONRY BLOCK PAINT FINISH
LOCALE: 1 /8"= � '- O"
� - 100 1 HR. RATED CAULKING AT DRYWALL PARTITION SEE DETAIL NO. 1 SHT. D-4
® u
CD 142 R-11 INSULATION AT WALL
� 107 CONCRETE PAVERS SEE DETAIL NQ. 5 SHT. D-4
CEMENT FINISH PAINTED A- 1
CD
d
� �
CD".ova .
cr
0
C.3 CD
� �
En
f
C13 r-
U) �
w