01-0665-001 | . . . 24" MIN. 24" MIN. e 7 24" MIN. 7 e \-EXTERIOR SIDEWALL \ff5/ P.T. 2x8 SHIMS P.T. 2x8 SHIMS I Ar\ 4"x8"x`16" CAP BLOCK 4%8%16" CAP BLOCK X� X� OUTRIGGER TYP. END OUTRIGGER --'HEADER CHASSIS TIE-DOWN STRAP \-TYP. HURRICANE 34" MAX. HEIGHT STRAP TYP. HURRICANE TO BOTTOM OF :'7 FLOOR JOIST STRAP TYP. GROUND TYP. GROUND EXISTING CONCRETE SLAB ;..... ANCHOR ANCHOR TYP. GROUND EXISTING CONCRETE SLAB EXISTING CONCRETE SLAB DRILL HOLE FOR 2 # 5 REBAR PER PIER INTO EXISTING CONCRETE SLAB ANCHOR AND EPDXY THE REBAR IN TO HOLE 4" DEEP MIN. FILL ALL CONCRETE PIERS WITH TYPE M,N, OR S MORTAR EXISTING CONCRETE SLAB SECTION A A- SECTION B B_ SECTION C - C_ SECTION D - D- EXISTING CONCRETE SLAB rT,� ISOLATED PIER TIE-DOWN AT MATELINE �LD�l DRILL HOLE FOR 2 # 5 REBAR PER PIER INTO EXISTING CONCRETE SLAB AND EPDXY THE REBAR INTO HOLE 4" DEEP MIN. FILL ALL CONCRETE PIERS WITH TYPE M,N, OR S MORTAR 4%8"x16" CAP BLOCK CRIMP STRAP WITH A LISTED STRAP CRIMP OR PRE MANUFACTURED FRAME CLIP z 8"x8"xl 6" EXISTING CONCRETE SLAB PERIMETER PIER IN CORNERS AND ALONG I BEAMS rA _�;T_ F ITT T FIT' FIT' F T. F 7T. DRILL HOLE FOR 2 # 5 REBAR PER PIER INTO EXISTING CONCRETE SLAB AND EPDXY THE REBAR INTO HOLE 4" DEEP MIN. FM FM FILL ALL CONCRETE PIERS WITH TYPE M,N, OR S MORTAR FRAME TIE-DOWN STRAP Cf) OR BOTTOM OF I-BEAM UM STRUCTURAL NOTES: CONCRETE MASONRY UNITS FM 1) MAX SPACING OF TIE DOWNS TO BE 4'-6" ALONG SIDE WALLS FM FM FM (PERPENDICULAR TO I BEAMS). EXISTING CONCRETE SLAB ISOLATED PIERS Lai U91i U!�jj u9ji U91i AT ALL OTHER LOCATIONS 7'-0". SEE PLAN FOR END WALL TIE DOWNS. 0 MATELINE F"T. C i F.T. LD�F D' FRAME TIES ONLY, NOT OVER ROOF. :E STRAPS REQUIRED, SEE DETAIL F-FD1 < FIRST STRAP FROM END WALLS NOT TO EXCEED 3'-4" HEAVY LOAD PIER AT MATE LINE 2) F.T. = FRAME TIES IQF D�l NOTE: CONCRETE UNITS MAY BE A COMBINATION OF 4" x 8" 16", AND 4" x 16" x 16" UNITS LLJ F.T. LLJ F T. 3) MAXIMUM WIND SPEED 110 MPH. Cn FIT, 4) ALL TIE DOWN ANCHORS SHALL HAVE MINIMIM 4725 LB. CAPACITY AND AHD SHALL BE INSTALLED IN ACCORDANCE WITH LM I CHAPTER 23 OF THE 1994 SFBC. ANCHOR HEAD WITH 1/2"xY EXPANSION BOLT (ZINC PLATED) # MICS2. F 7T.— F7T,_ _�;T_ F ITT F I 7T F 7T. T_ j;T Ff'T F f;T7. F7 4;T-- F CALCULATIONS TO COMPLY WITH 1994 EDITION OF SFBC 4p 4p A 6) EXISTING 6" SLAB THICKNESS SHALL BE VERIFIED FDI BY CORING THE SLAB AT 3 RANDOM LOCATIONS. RESTORE CORE HOLES WITH NON-SHRINK GROUT. FOUNDATION PLAN SHOWING FRAME TIES AND ANCHOR LOCATIONS . FOUNDATION NOTES: Nariman S. Balsara, P.E. No. 15079) l.- TIE-DOWN STRAPS TO BE 1-1/4"x .035" GALVANIZED STEEL FEDERAL SPECIFICATION 5.- IT WILL BE THE BUILDING OWNER'S RESPONSIBILITY QQS - 781 - H TYPE - 1 FINISH-13 GRADE-1, TIE-DOWN STRAPS AND CONNECTING TO INSURE THAT ALL GRASS, LOOSE DEBRIS, ETC. ARE REMOVED FROM UNDER THE BUILDING. CONSTRUCTION TRAILER HARDWARE TO HAVE 4,725 # MINIMUM ULTIMATE CAPACITY. ara & Associates, Inc. (EB 7220) 6.- WOOD SHIMS MAY BE INSTALLED WHEN NECESSARY, BETWEEN THE 1-BEAM AND THE TOP = M ANCHORS TO HAVE 5,200 MINIMUM ULTIMATE LOAD CAPACITY. OF THE PIER. SHIMS SHALL BE FREE OF KNOTS, CHECKS, SPLITS, co-n-sulting engineers DRAWN: SEAL: 2.- SEE ABOVE FOUNDATION LAYOUT FOR TIE-DOWN STRAP SPACING. AND SIMILAR IMPERFECTIONS, SHIMS SHALL BE OF P.T. LUMBER GAC SHEET No. 3.- ALL PIERS SHALL BE 8% 8% 16" MASONRY BLOCKS ON EXISTING CONCRETE SLAB. AND BEARING AT ALL CONTACT POINTS SHALL NOT BE LESS THAN 2/3 OF THE BEARING PRIOR TO ADDING THE SHIMS. 119450 Sunset Drive, Ste. 200—B, Miami, FL 33173 4.- MINIMUM SOIL BEARING CAPACITY IS 2000 PSF. TO BE VERIFIED BY BUILDING'S OWNER. 7.- NOTE ALL MASONRY PIERS SHALL BE INSTALLED WITH TYPE M, N OR S MORTAR. CHECKED: PH. (305)274-4595, FAX (305)274-4713 NSB S- 1 OF __ 6200 SW 73 STREET MIAMI FL, 33143 SCALE: N.T.S. JOB # 21040