Loading...
01-0575-005 o 0 cq0 cq DEMOLITION SEQUENCE � REMOVE EXIST. U o Doom I. REMOVE ALL REMAINING ELECTRICAL, PLUMBING, 4 H V.A.C. 0 EQUIPMENT FROM ROOF STRUCTURE. O c 2. REMOVE PART OF PARTITIONS Q BATH AREA AS INDICATED 0 ON DEMOLITION PLAN pr4 0 'm 3. REMOVE EXISTING ROOFING 4 GYPSUM BOARDS. 4. BRACE EXISTING REMAINING C.M.U. WALLS BEFORE BEGINNING REMOVAL OF ROOF STRUCTURE. E=4 ko REMOVE EXIST. Q C BATHROOM FIXTURES 5. REMOVE EXISTING ROOF STRUCTURE TO INCLUDE STEEL Z I WINDOWS (TYI-d l i TO REMAIN EXISTING JOIST BEAMS. .00 I STORAGE II � o ED 0�-__7 � �REMOVE EXIST. ° � I \ PARTITIONS I = E- DEMOLITION NOTES W o Ix 1. IF APPLICABLE, OBTAIN AN ASBESTOS INSPECTION REPORT PRIOR ' 0 I � TO DISTURBANCE OF ANY MATERIALS. 0 EXISTING I I 2. CAP EXISTING ELECTRICAL AND PLUMBING FIXTURES BEING: REMOVED. I I DINING AREA A DECORATIVE WOO STRUCTURE I M���5 �--'�� 3 REMOVE LL DE RA VE D RE REMOVE EXIST. I ( 4. DURING DEMOLITION PROCESS IF ANY STRUCTURAL WALLS, COL'S m PARTITIONS � � � _ AND BEAMS ARE ENCOUNTERED NOTIFY THE ARCHITECT/ENGINEER DO I I � NOT SAW-CUT ANY STRUCTURAL SLABS WITHOUT INSTRUCTIONS FROM THE STRUCTURAL ENGINEER. 0 5. DISCONNECT ELECTRICAL MAIN PRIOR TO DEMOLITION. � CD [— I o � 6. DISCONNECT WATER MAIN PRIOR TO DEMOLITION I REMOVE EXIST. FLOOR TILE � � \ i -1. DISCONNECT GAS MAIN PRIOR TO DEMOLITION. I I EXIST, COLUMN TO S. REMOVE ALL ELECTRICAL FIXTURES 4 HOUSINGS, ELECTRICAL &=4 EXISTING I I ( I BE REMO D CONDUITS k WIRING TO REMAIN, TEMPORARY CAP AS REQUIRED S i (PROVIDE ROBING A FUTURE USE. I FREEZER i II I PR � � FOR FU RE U E ( ( I I I EXISTING NECESARY DURING DEMOLIT16W I I II I VESTIBULE S. PROVIDE TEMPORARY BARRIER FOR ALL DROPS OVER 24' HIGH, ^ REMOVE EXIST. DR$- 10, REMOVE SOME EXTERIOR WINDOWS 4 DOOR AS SHOWN ON PLAN. REFER TO ARCHITECTURAL �� 11. ALL NEW EXTERIOR OPENINGS SHALL BE TEMPORARILY COVERED W1 FLOOR P ANSI PLYWOOD. REMOVE EXIST. DRYWALL COLUMN I I�- AND EXIST. STL. COL. BENEATH REMOVE EXIST, DRS ( EXIST. COL TO BE REMOVED REFER TO ARCHITECTURAL EXIST. 5 DEEP I I FLOOR PLANS T CISTERN TO REMAIN LEGEND I NEW OPENING FOR DOORS I I REFER TO ARCHITECTURAL _j I FLOOR PLANS TO VERIFY EXISTING S' GONG. BLK WALL Q I —I I LOCATIONS REMOVE EXIST. DRYWALL COL.'S EXISTING 8" CONC. BLK WALL 4 EXIST. STL. COL. BENEATH I I I I I O TO BE DEMOLISHED w EXISTING 4" PARTITION \ \ I I REMOVE EXIST. I I WINDOWS TO FLOOR PLAN I I I N EXISTING TO BE DEMOLISHED PIZZA OVENS ~ TO BE DEMOLISHED I I I 5AR I ( EXISTING CONCRETE COLUMN I I � I I I I I I I I I EXISTING PARAPET O 15 -4 A,F.F. I I j NEW OPENING FOR DOORS o 1 I REFER TO ARCHITECTURAL TOP EXISTING PARAPET REMOVE EXIST. FLOOR TILE I Oka ( I � FLOOR PLANS TO VERIFY LOCATIONS EXISTING STEEL EL, + 15'-4" w J I ROOF JOISTS 4 BEAMS Q I i EXIST. BAR (TO SE REMOVED) REMOVE / CONSULT KITCHEN II REMOTE EXIST. ROOF EXIST. CONC. BEAM I CONSULTANT FOR � EXISTING EQUIPT. REMOVAL REMOVE EXIST. EXISTING / WINDOWS REFER TOP EXISTING TIE BEAM KITCHEN / DINING AREA / ( TO FLOOR PLAN _ _ — 0 IIII EL, + 13'-2" EXIST. COLUMN TO 4 I I REMOVE EXIST. WOOD DECK BE REMOVED SUBFLOOR (EXIST. CONC. (PROVIDE SHORING AS I I REMOVE EXIST. SLAB BELOW TO REMAIN) NECESARY DURING DEMOLITION) PARTITIONS I I / \ L� N II NEW a.�EKING FOR DOOR / REMOVE EXISTING VESTIBULE �- REF R`\TO ARCHITECTU L II FL R PLANS TO VERIFY Ll LO ATfePNS / W I REMOVE EXIST. DRS \ / REMOVE EXIST. DRS REFER TO EXISTING \ / EXISTING CMU WALL z A REFER TO FLOOR PLAN DINING AREA / \ / (TO REMAIN) W . o FLOOR PLAN � i EXISTING REMOVE EXIST. DRS I I REI=ER TO REMOVE EXISTING PARTITIONS I YESTISUI_E X �- FLOOR PLAN W II \ II REMOVE EXIST. DRS ER TP ARC H(TEiGTU L (�'a I lI EXIST. COLUMN TO I ' LO BE REMOVED I FLOOR LANS \ � II EXISTING I I (PROVIDE SHORING AS II / EXIST. COLUMNS TO ( // \ W CO NECESARY DURING DEMOLITIONi 5E REMOVED STORAGE I � / \ EXIST. 5' DEEP EXISTING II I / \ C15TERN TO REMAIN EXISTING II '- E S NG I / \ IIII STORAGE I � � OFFICE II _ L- _ EXIST. FIN. FL. =t\7 EL. + 0'-0" REMOVE DAM a . AGED WOOD FRAMED WALLS � REMOVE METAL FRAMED WALLS 4 ROOF STRUCTURE ROOF STRUCTURE 4 22'-0" EXIST. CONT. GONG. ° m 9 EXIST, 5' DEEP FOOTING 0 � N � Q ISTERN TO REMAIN a O C 5ECTION SCALE : 3/4' = 1'-0' t�-2 FOUNDATION DEMOLITION � AN SCALE : 1/4' 1'-0' ro cc ENGINEERING CO.. INC, � U •n 'd b U cif CARLOS J. CARDOSO, P.E., No. 55780 sheet no. 4345 S.W. 72nd AVENUE, SUITE G ;,'� MIAMI, FLORIDA 33155 (305) 666-2750 CA: 00003033= ic 9 1 of 2 i 0 _ M v>