07-18-06 (10)ELECTRICAL NOTES I.- CONTRACTOR SHALL FURNISH ALL LA130R, MATERIALS AND EQUIPMENT A COMPLETE ELECTRICAL INSTALLATION IN ACCORDANCE WITH THESE DRAWINGS. 2.- COMPLY WITH THE N.E.C. AND THE So. Fla. BUILDING CODE 3.- PROVIDE EMPTY CONDUITS AS REQUIRED FOR TELEPHONE SYSTEM 4.- OBTAIN ALL PERMITS FOR WORK UNDER THIS CONTRACT. 5.- PROVIDE TEMPORARY POWER AND LIGHT OUTLES FOR USE BY OTHER TRADES. 6.- PROVIDE ALL REQUIRED CONNECTIONS FOR OTHER TRADES. 7.-- COORDINATE ALL OUTLET LOCATIONS WITH BUILDING ARCHITECTURAL FEATURES. 13.- CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. 9.-- ALL CABLE SHALL BE COPPER. 10.- INDOOR CONDUIT SHALL BE EMT. .- OUTDOOR UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC. UNDER PAVED AKEAS IT SHALL BE ENCASED IN CONCRETE. MINIMUN COVER SHALL 16 INCHES: 12.- ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR. ELECTRICAL LEGEND DUPLEX OUTLET (110V AT 8" AFF. TO CENTER) SWITCH AT 48" AFF.TO CENTER. 3 3 -WAY SWITCH AT 48" AFF. TO CENTER. II WALL MOUNT LIGHT FIXTURE ELECTRICAL PANEL. CEILING FAN W/ LIGHT FIXTURE j ELECT. SCHEDULE Bc NOTES PROVIDE 3 NEW CIRCUIT TO EXISTING 200 AMP PANEL EXISTING COND REMARKS KW PANEL I POLE 1, 2 RANGE CAN CARRY 60 2 2 6 THE STRIP HEATER (KW) LOAD & SPARE 240 15 AVAL. 2 E L E C T R I C A L S C H ED U L E(EXIST. use zoo L MP CIRCUIT USE VOLT AMP AK BREER WIRE COND REMARKS KW TRIP I POLE 1, 2 RANGE 240 AC25.OM.817 EER 60 2 2 6 3/4 STRIP HEATER (KW) 12 3, 4 WATER HEATER 240 15 30 2 3/4 4.5 7,8 STRIP HRT FAN ( AHU -1) 240 32 50 2 2 #8 1/2" N.D.L. 17 910 A /C -1 240 20 30 2 MW 314" N.D.L. 11.9 11,12 DRYER 240 20.1 30 2 3 #1 C 3/4 " 5 13. WASHER MACHINE 120 4.5 20 1 2 #12 1/'," 1.5 14 REFRIGERATOR 120 3.0 20 1 2 #12 1/2" 1.3 15 DISHWASHER 120 4.5 201 1 2 #12 1/2" 1.5 16, 17 SMALL APPLIANCE 120 4.5 20 1 1 2 #12 112" 3.0 18 -25 GENERAL LIGHTING(EXIST) 120 15 1 2 #12 1/2" 2051 SQ.FT x 3W= 6153 6.15 19 -20 GENERAL LIGHTING(NEW) 120 15 1 2 #12 1/2" 353.4 SQ.FT x 3W= 1180.2 1.18 21 WALL A/C (NEW) 120 15 1 2 #12 112" 1.5 22 BATH GFI 120 15 1 2 #12 1/2" 1.5 L E S S N. D. L. 37.63 L 0 A D C A L C U L A T 1 0 N 100% FIRST 10 K.W. OF LOAD 10.0 40% OF REMAIN LOAD 27.63 x 407.= 11.05 11.05 N. D. L. 17 TOTAL LOAD FOR FEED ER 38.p5 TOTAL AMPS (WATTS VOLTS) 38050 x : 240= 158.54 AMPS. ELECTRICAL PLAN SCALE 1/4"=1"-0" A/C EQUIPMENT SCHEDULE 2 TONS A/C NUMBER: 1 UNITS TOTAL COOLING (BTU /H): 25,000 C.F.M. 1000 LOCATION: WALL MANUFACTURER: KENMORE SERIAL NUMBER: JK91421776 AIR HANDLER UNIT MODEL No. AC25.OM.817 EER SENSIBLE BTU /HR 15,200 LATENT BTU /HR 7,200 STRIP HEATER (KW) 10 SEER 12 REINFORCED MASONRY NOTES: 1. ALL STRUCTURAL CONCRETE BLOCK UNITS SHALL CONFORM TO THE STANDARD SPECIFICATIONS FOR HOLLOW LOAD BEARING CONCRETE MASONRY UNITS, ASTM C -90' 2. ALL UNITS SHALL BE BUILT TO PRESERVE THE VERTICAL CONTINUITY OF THE CELLS TO BE FILLED, AND TO MAINTAIN A CLEAR, UNOBSTRUCTED C❑NTINOUS VERTICAL CELL MEASURING 2 INCHES BY 3 INCHES, 3, CLEANOUT OPENINGS SHALL BE PROVIDED AT THE BOTTOM OF ALL CELLS TO BE FILLED IN ORDER TO VISUALLY INSPECT THE CONTINOUS FLOW OF CONCRETE, 4. VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION AT THE BOTTOM AND TOP OF THE CELL TO BE GROUTED, MINIMUM LENGTH OF THE LAP SPLICE= 48 BAR DIAMETER. MAXIMUM HEIGHT OF LIFTS TO BE LIMITED TO 4 FT. HIGH, 5. ALL CONCRETE USED FOR GROUTING SHALL BE PEAROCK W/ A COMPRESSIVE STRENGTH OF 1 3,000 PSI AT 28 DAYS (10' SLUMP) 6, MORTOR STRENGTH TO BE TYPE 'M' (2,500 PSI) 7. SEE SHEET S -5 FOR TYPICAL GROUTED CELL SECTION, 8, ULTIMATE COMPRESSIVE MASONRY STRESS (F`m) TO BE AS FOLLOWS, #5 ER 48' VERTICAL OR AS SHOWN ON PLAN PR ❑VIDE 9 GA, LADDER -TYPE H❑RIZ. REINF. 2 16' O.C. 10. SPECIAL INSPECTOR REQUIRED FOR REINFORCED MASONRY CONSTRUCTI ❑N, cD I c TIMBER N ❑TES 1 ALL TIMBER DESIGN AND FABRICATI ❑N SHALL CONFORM TO LUMBER AND ITS FASTENINGS, NO LESS THAN DOUGLAS FIR No. 2 MIN, 2 USE STRESS RATED TIMBER FOR ALL WOOD STRUCTURAL MEMBERS WITH A MINIMUM BENDING STRESS OF 1200 PSI. LUMBER USED FOR JOISTS, RSFTERS, TRUSSES, COLUMNS, BEAMS OR ANY STRUCTURAL MEMBER SHALL BE OF A STRENGTH NO LESS THAN DOUGLAS FIR. No. 2 MIN. 3 ALL TIMBER IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED (P.T.) 4 ALL TIMBER CONNECTORS INCLUDING BOLTS, WASHERS AND NUTS SHALL BE GALVANIZED, 5 ALL SHEATHING SHALL HAVE THE THICKNESS CALLED FOR IN PLANS. PLYWOOD PANELS SHALL BE NAILED TO SUPPORTS WITH 8D NAILS AT 6' O.C. THRUOUT & 10d AT 4' O.C. AT GABLES PLYWOOD CLIPS SHALL BE USED WHERE PLYWOOD SHEETS ABUT EACH OTHER, 6 LUMBER USED FOR STUDS IN EXT. WALLS AND IN INT. BEARING WALLS SHALL BE OF A STRENGTH NOT LESS THAN STUD GRADE OF DOUGLAS FIR, 7 LUMBER USED FOR STUDS IN INTERIOR NON- BEARING PARTITIONS SHALL BE USED OF A STRENGTH NOT LESS THAN UTILITY GRADE, 8 ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE. 281_7„ V-13" ROOF FRAMING PLAN SCALE 1/4"=1"-0" nn ol /ov U.S.P.) GALV. MTL. STRAP 10d NAILS o.01- 0912.05 APACITY= 1040LBS. REFER TO ROOF FRAMING PLAN FOR FORMED CAST IN PLACE TIE BM. strap detail ( ANCHORAGE DTL.) scale: N.T.S. Drill 4.5/ "O 6" D p I�ol to ECeneow�s ands e w poxy rou Existing concrete tie beam tar Column 4 #5 x 1'4" J Dowels anchored w /epoxy Grout rah 1'6" O.G. at existing Conc. Block Wall DETAIL # S -2 scale: N.T.S. CUT EXIST. OH. AS REQ'D. 2" x 10" WD. JOISTS ® 16" O.C. RT 18 (BY U.S.P.) GALV. (N.O.A. # 01- 0912.05 UL= 1020 ) TWISTED STRAP (18) -10D NAILS TO EA. JOIST & 2) 1 2-x6" " TAPCON SCREWS ATTACHED TO EXISTING TIE BEAM connection dletail scale: N.T.S. U -220 GA. GAL V. MTL.JOIS T HANGER JS/ IL TOYHE DER W/ (8)-16d NAILS ACCEPTANCE No: 01- 0417.11 UL= 1820 APPROVED: O6(�8[01 EXPIRES: a7' /a 0 2" x 12" WD. OUTLOOKERS n n n 0 24" O.C. SEE FULL SECTION FOR GALV. STRAP NOTES outlooker detail scale: N.T.S. 3 REVI510N5: BY: LLl O_ Z rx A 0- 'z A�r7 I � I! > N N r7 Nz -¢d I I 2 W z 101J, d`D EJ z � bi vi -ww -w 0 AM��� <�" Z LL_ n iX Q U U Z CL LL1 U_ G Q W Q Cfl 0 o U c17Q0 W Ld r`0 zo o�_ 00 FI L1' V) �? = N _J W Q°� W Q o LL i 0 w O Ld 3: O Z _D Q O LL_ Project No.: 0603 -28 Date: 03 -30 -2006 Drawn By: D.P. SCALE: NOTED Sheet No. 3 3 OF 3