Loading...
07-18-06 (8)5/8" MK. CAULKING - - (w/ BACKER ROD AS REQ'D.) WIN CONC FILLED CELL w/- 1 #5 VERT B (TYP.) 5/8" THK. STUCCO CAULKING (w/ BACKER ROD AS REQ'D.) NOTE: BED CAULK WINDOWS TYPICAL. IAMB / HEAD 4v 4 4. 4 v e 4. HEAD JAMB 1" x 3" P.T. WOOD BUCK W/ 1/4" x 2 -•3/4" TAPCON SCREWS @4" FROM THE END & 15" O.C. MAX. (1 --1/2" MIN. CONC. EMBED.) CAULKING (w/ BACKER ROD AS REQ'D.) CONC. BLOCK 5/8 THK. STUCCO ETAI L 1/2" GYPSUM WALL BOARD R -4.5 INSULATION IN CAVITIES P.T. WOOD FURRING STRIPS AT 24" O.C. ACRYLIC CAULKING INTERIOR WOOD DOOR CASING 2X4 P.T. WOOD BLOCKING, ATTACHED TO CONC, MASONRY W/ 1 /q7 0 X 3 LNG. TAPCON CONC. SCREWS, W/ MIN. OF EMBEDMENT OF 1 -3/4" INTO CONC. SPACED @ 3" FROM EA. END & BALANCE 0 12" O.C. ® JAMB, & 10" O.C. 0 HEAD WOOD DOOR FRAME, INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACT. SPECIFICATIONS SET FORTH IN THE APPROVED PRODUCT CONTROL APPROVAL ENTRY DOOR, REFER TO DOOR SCHEDULE) HINGE 4X6XO.025' PLATE, (® HINGES, WHEN REQUIRED) SEALANT - 3/4" STUCCO CORNER BEAD TWO COAT STUCCO FINISH (ON 8" CONCRETE MASONRY WALL 8" CONCRETE MASONRY WALL, (TYP.) REFER TO STRUCT. DWGS. FOR REINF. CONC. BEAM (HEADER) 1/2' G.W.B. 1X2 PT. WOOD FURRING ® 24" O.C. 1" x 3" P.T. WOOD BUCK W/ 1/4" x 2 -3/4" TAPCON SCREWS ®4" FROM THE END & 15" O.C. MAX. (1-1/2" MIN. CONC. EMBED.) — WINDOW FRAME in CONC. BLOCK 1/2" G.W.B. 1X3 PT. WOOD FURRING ® 24" Q.C. N.T.S. 1" x 3" P.T. WOOD BUCK W/ 1/4" x 2 -3/4" TAPCON SCREWS 04" FROM THE END & 15" O.C. MAX. (1- --1/2" MIN. CONC. EMBED.) WINDOW FRAME SILL WINDOW BUCK DETAILS WINDOW FRAME WINDOW STOOL SILL PRE—FAB, WINDOW SILL 1X3 PT. WOOD FURRING ® 24" O.C. 1/2" G.W.B. N.T.S. DOOR SCHEDULE MARK SIZE TYPE MATERIAL N. 0. At (D DBL --36 "x80 "x1 -3 4" EXT. ALUM. /GLS 01- 0417.04 ® m" x 80" x 1" EXT. ALUM. #01 - 092 3.02 © EXISTING WINDOW SCHEDULE MARK SIZE TYPE N.O.A. Q SH 34 53" X 50" COLONIAL #01- 1023.02 2 FIXED GLASS EXISTING 101-311 28' ---7" 10' --3" GENERAL NOTES: I.-WORKS PERFORMED SHALL COMPLY WITH THE FOLLOWING A) ALL NOTES WRITTEN ON ALL SHEETS AND / OR PLANS OF THE PRESENT PROJECT. B) ALL APPLICABLE LOCAL, COUNTY OR 5TATE ORDINANCE. 2.- ON 51TE VERIFICATION OF ALL DIMENSIONS AND CONDITIONS SMALL BE RESPONS151LITY OF THE CONTRACTOR. 3.- IT SHALL BE RE5PON5161LITY OF THE GENERAL CONTRACTOR TO VERIFY WITH THE ENGINEER IN WRITING ANY OMISSIONS OR DISCREPANCIES ARISING FROM THE INFORMATION CONTAINED WITHIN THESE SPECIFICATIONS AND DRAWIN65. 4.- CONTRACTOR AND SUBCONTRACTOR SHALL COMPLETELY FAMILIARIZE THEMSELVES WITH EXISTING 51TE CONDITIONS AND VERIFY THE LOCATION AND AVAILABILITY OF ALL UTILIE5 PRIOR TO SUBMITTING BID. 5.- CONTRACTOR SHALL BE RESPONSIBLE FOR THE DE51NG AND CONSTRUCTION OF THE FORMWORK. G.- IF ANY DISCREPANCIES ARE FOUND, STOP WORKING AND CONTACT THE OWNER THE ENGINEER. FLOOR PLAN SCALE: 1/4 " =1' -0" WALL LEGEND EXISTING 8" C.15.5.WALL ® NEW 8" C.13.5.WALL M TIE COLUM5 L =1.64' 0 T SITE PLAN SCALE: 1"=20' LEGAL DESCRIPTION INTRUSION & BURGLARY SECURITY NOTE: ALL EXTERIOR DOORS SHALL BE PROVIDED WITH CYLINDRICAL TYPE LOCK SETS, LATCH BOLT BY KNOB; LATCH BOLT DEAD - LOCKED WHEN DOOR CLOSED. KEY OPERATED FROM OUTSIDE WITH PRIVACY TURN BOTTOM FOR LOCKING OUTER KNOB WHICH IS NOT AUTOMATICALLY RELEASED. CAPABLE OF RESISTING A FORCE OF 300 LBS. IN ANY MOVABLE DIRECTION. MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH DEAD BOLT KEY OPERATED FROM OUTSIDE AND BY TURN KNOB FROM INSIDE OTHER EXTERIOR DOORS TO BE PROVIDED WITH INTERIOR SINGLE DEAD BOLT. ALL TO BE 1" MIN. THRUST AND OF HARDENED OR CONTAIN INSERTS. AT DOUBLE DOORS SECOND DOOR SHALL BE PROVIDED WITH HAND BOLT TOP AND BOTTOM. DOORS TO BE MOUNTED ON 1 1/2" PAIR OF HINGES WITH NON-EXPOSED SCREWS AND NON -- REMOVABLE PINS BY SET SCREW IN BARREL. MAIN ENTRANCE DOORS TO HAVE DOOR SCOPE PERMITTING INSIDE VIEWER A 180 DEGREE OBSERVATION ANGLE OF OUTSIDE WHEN DOOR CLOSED. HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE NON - REMOVABLE PINS. GLASS IN EXTERIOR OUT DOORS AND ALL GLAZING WITHIN 48" OF INSIDE LOCKING DEVICE OF DOOR SHALL COMPLY WITH A.N.S.I. 297.1. INTERIOR DOORS TO HAVE CYLINDRICAL TYPE LOCK SETS WITH PRIVACY LOCK BY INSIDE PUSH BOTTOM WHICH AUTOMATICALLY OPENS BY TURN OR BY CLOSING. EXTERIOR SLIDING DOORS SHALL BE PROVIDED WITH TEMPERED GLASS AS SET FORTH BY AMERICAN NATIONAL STANDARDS, INSTITUTE'S STANDARD 297. SLIDING GLASS DOOR CON- STRUCTED AND INSTALLED SO THA NO PANEL CAN BE LIFTED FROM THE TRACK WHEN IN -LOCK POSITION. ACCORDING TO ALUM. ASSOC. STANDARD FOR FORCE -ENTRY RESISTANCE AAMA 1303.3. ADDITIONAL TO THE MANUF. LOCK PROVIDE DEAD BOLTS AT MEETING MULLIONS. ALL WINDOWS; AWNING, SINGLE HUNG OR HORIZONTAL SLIDING SHALL BE PROVIDED WITH A LOCKING DEVICE CAPABLE OF WITHSTANDING A FORCE OF 150 LOS. APPLIED IN ANY OPERABLE DIRECTION, OR AS SPECIFIED IN THE PAN AMERICAN FORCE AWNING TYPE 49 389 F. WINDOW FRAMES SHALL BE CONSTRUCTED SO THAT WHEN FIXED OR LOCKED THEY CANNOT BE REMOVED FROM THE OUTSIDE. OVERHEAD LOADING DOORS SHALL BE PROVIDED WITH MULTIPLE POINT LOCKS OR BE LOCKED AT MORE THAN ONE POINT WITH HARDENED BOLTS WITH INSERTS ENGAGING AT LEAST TWO OPPOSITE POINTS A MIN. 5/8 ". / VW / i F.I.P. (NO P) 9y 4. i \ \ NEW ADDITION SCOPE OF WORK NEW ADDITION OF FAMILYROOM LOT 2 BLOCK 9 SUBDIVISION TWIN LAKES MANOR 5U B, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 57 AT PAGE 82 OF THE PUBLIC RECORDS OF MIAMI -DADE COUNTY, FLORIDA. REVISIdNS: BY: Ld Q CLw0 V) j NN Ww 0 J°� 44 ul ©Mw�>W_ o0 a � m n r7 o _J fa 0 o 0-1 >c Qa (3ku< z W Lam. Q Ld • 0 o (I) Q o --D I LL_ m LLJ d w r1r) 00 m E o .. ( f-� = N J LLJ Q°t WU0-a LLI o w Q o� Z _D Q0L Project No.: 0603 --28 Date: 03 -30 -2006 Drawn By: D.P. SCALE: NOTED Sheet No. 1 OF 3