01-0679-028 RTU SCHEDULE LINEAR SUPPLY/RETURN DIFFUSER SCHEDULE GENERAL NOTES A- SCOPE OF WORK DIFFUSER # LENGHT INLET SIZE MANUFACTURER MODEL # OF SLOTS SLOT WIDTH CFM PER FOOT COMMENTS WORK SHALL INCLUDE ALL LABOR, EQUIPMENT, AND PERFORMING ALL OPERATIONS IN CONNECTION WITH THE UNIT NUMBER RTU-1 RTU-2 FURNISHING OF ALL AIR CONDITIONING, HEATING AND VENTILATION WORK AS SHOWN ON DRAWINGS, HEREIN SUPPLY CFM J 6' 10" TITUS ML-38 2 SLOTS 3/4" WIDTH 50 CFM/FT PROVIDE W/PLENUM MODEL MP-38 SPECIFIED AND/OR EQUAL EQUIPMENT SUBMITTED FOR APPROVAL. 2-10-0-0 3 900 EXT.STATIC PRESS. 0.50 0.75 K 6' 12" ML-38 2 SLOT 3/4" WIDTH 75 CFM/FT PROVIDE W/PLENUM MODEL MP-38 B— AIR CONDITIONING SYSTEM OF ROOFTOP TYPE +� SHALL CONSIST OF ROOF TOP UNIT AS INDICATED ON DRAWINGS. SYSTEM SHALL BE OUT5IDEAIRCFM 525 725 2 4 10 MLR-38 4 SLOT 3/4 WIDTH 167 CFM/FT PROVIDE W/PLENUM MODEL MPR-38 PROVIDED COMPLETE WITH FRAMES AND ENCLOSURES, WIRING, NECESSARY CONTROLS TOTAL CAPACITY BTUH 63,800 125,800 3 3' 10" MLR-38 4 SLOT 3/4" WIDTH 200 CFM/FT PROVIDE W/PLENUM MODEL MPR-38 REFRIGERANT CHARGE AND OIL CHARGE, STRIP HEATER, ROOF CURB, AND FILTER BOX. SENSIBLE CAPACITY BTUH 46,700 91,500 PROVIDE SMOKE DETECTORS TO SHUT OFF UNIT, BLITSTEIN STRIP HEATER 10.5 14.7 C— GUARANTEE AIR TEMP ENT.CONDENSER 95 95 95 CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE COVERING ALL WORKMANSHIP AND DESIGN AIR TEMP ENT.EVAP.DBNVB 80167 80/67 80167 MATERIALS FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. RTU FLA 24.6 45.6 D- FIRE DAMPERS/SMOKE DAMPERS FIRE DAMPERS/SMOKE DAMPERS AS APPROVED BY LOCAL GOVERNING AUTHORITIES SHALL BE INSTALLED ASSOCIATES IN ALL DUCTWORK PASSING THRU A FLOOR, ROOF, FIRE PARTITION ❑R FIRE WALL < PROVIDE PHASE VOLTAGE 3 PHASE 230V 3 PHASE 230V ACCESS) REQUIRED BY BUILDING CODES. Architecture MANUFACTURER CARRIER CARRIER E- CONTRACTOR SHALL PROVIDE POSITIVE MEANS FOR BALANCING EACH INDIVIDUAL AIR CON- Interior Design RTU MODEL NUMBER 50HJ006-5 50HJ012-5 ROOF CAP WITH DITIONING SUPPLY AIR OUTLET, AS PER SCHEDULES & DRAWINGS, SYSTEMS SHALL BE BACKDRAFT DAMPER AUDIBLE ALARM BALANCED AGAINST THE ACTUAL INSTALLED STATIC PRESSURE. 285 Sevilla Avenue IDNIZATI❑N SMOKE DETECTOR IN NORMALLY F- BEFORE SUBMITTING HIS FINAL PROPOSAL, THE CONTRACTOR SHALL EXAMINE THE SITE OF Coral Gables, Fl 33134 UNIT TYPE ROOFTOP DX ROOFTOP, DX FROM OTHER DETECTOR <SEE PLANS) OCCUPIED AREA OR THE PROPOSED WORK TO DETERMINE THE EXISTING CONDITIONS THAT MAY AFFECT HIS WORK 4"� EXHAUST DUCT THRU❑GH BUILDING SEER OR EER 13.0 SEER 11.0 EER FROM DRYER IF APPLICABLE FIRE ALARM SYSTEM AS HE WILL BE RESPONSIBLE FOR ANY ASSUMPTIONS MADE BY HIM IN REGARDS THERETO, (305 444-4433 _�. AREA SERVING MANICURE RETAIL 8" MIN, IF APPLICABLE G- ANY APPARATUS, APPLIANCE, MATERIAL, WORK OR INCIDENTAL ACCESSORIES OR MINOR DETAILS - - - - -_ - - - - - - 24 NOT SHOWN BUT NECESSARY TO MAKE THE WORK COMPLETE AND PERFECT IN ALL RESPECTS AND VDC READY FOR OPERATION, EVEN IF NOT PARTICULARLY SPECIFIED SHALL BE PROVIDED BY THE REMARKS O� S CONTRACTOR WITHOUT ADDITIONAL EXPENSE TO THE OWNER. VAC H- DUCTWORK DETECTOR TEST PANEL 1) DUCTWORK SHALL BE ,FIBER BOARD FOR ALL INDOOR AIR CONDITIONED SUPPLY AND U. L. LISTED OR FIRE ALARM PANEL RETURN DUCTWORK. SHEET METAL DUCTS SHALL BE USED FOR EXHAUST, AND NON-CONDITIONED IF APPLICABLE OUTSIDE AIR INTAKE. EXTERIOR (EXPOSED TO WEATHER) AIR CONDITIONED SUPPLY & RETURN DUCTS SHALL BE INTERNALLY INSULATED SHEETMETAL (R-8 MIN, ) MADE TOTALLY WATER PROOF. DETAIL AT ROOF CAP FOR DRYER EXHAUST 2) GLASS FIBER DUCTWORK SHALL BE 'OWENS CORNING' RECTANGULAR DUCT SYSTEM TYPE HD- FAN SCHEDULE N.T.S. EVAPORATOR FAN MOTOR FIRE/SMOKE DAMPER FR OR EQUAL, 1. 5 IN. INSULATION R-6. 5, CONFORMING TO APPLICATION MANUAL PUB. TO CLOSE IN CASE # 5-GL-2024 & DESIGN GUIDE, PB. # 5-IN-2617 FOR ALL ATTIC CONDITION SPACES, AUXILIARY CONTACT TO OF SMOKE SENSING NON-ATTIC CONDITIONS 1. 0 IN. INSULATION(R-4. 2) CONFORMING TO MANUASL PUB. #5-GL-2024 & SHUT DOWN IN CASE OF < IF APPLICABLE) & DESIGN GUIDE, PB. # 5—IN-2617. FAN N0. CFM SP. HP VOLTS/PHASE MODEL MFR. ACCESSORIES SMOKE SENSING 3) METAL DUCTS SHALL BE IN ACCORDANCE WITH LATEST ISSUE OF THE LOW VEL❑CITY DUCT CONS- TRUCTION STANDARDS, PUBLISHED BY THE "SHEET METAL AND AIR CONDITIONED CONTRACTORS EF-1 800 0.1 1/4 23OV/10 G8_100 GREENHECK AIR CONDITIONING S M❑K E DETECTOR NATIONAL ASSOCIATION, INC. ' AND THE LATEST PUBLICATION OF GUIDE & DATA BOOK OF THE AMERICAN SOCIETY OF HEATING, VENTILATING AND AIR CONDITIONING ENGINEERS. EF-2 90 0.1 " 120V/1 0 SP-6 GREENHECK EF-3 200 0.1 " 120V/10 SP-218 GREENHECK I- CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL COSTS INCURRED RESULTING FROM SUBSTI- TUTION OF EQUIPMENT AS WELL AS THE PERFORMANCE AND SPACE REQUIREMENTS OF SUCH EQUIPMENT. J- VIBRATION ISOLATION PROVIDE SUPPORTS OR MOUNTS FOR ALL EQUIPMENT LOCATED WITHIN THE BUILDING STRUC- ROOF CAP TURE POWERED BY ONE HORSEPOWER OR LARGER MOTOR, FLEXIBLE PIPING CONNECTIONS SHALL BE PROVIDED FOR ALL PIPING CONNECTED TO EQUIPMENT MOUNTED OR SUPPORTED BY VIBRATION ISOLATORS. K- TESTS gg EXHAUST DUCT BACKDRAFT DAMPER ALL TESTS SHALL BE PERFORMED AS REQUIRED DURING THE DIFFERENT STAGES OF SUPPLY/RETURN AIR DIFFUSER SCHEDULE WORK AND A FINAL 24 HOUR MINIMUM RUNNING TEST SHALL BE DONE AFTER ALL OTHER TESTS AND BALANCING OPERATIONS HAVE BEEN DONE. DIFFUSER # NECK SIZE PATTERN MANUFACTURER CATALOG # COMMENTS 8 MIN L— CONDENSATE PIPING - ` / _ _ Tff_ _ CONDENSATE PIPING SHALL BE OF PVC SCHED, 40, EXCEPT INSIDE A/C PLENUM SPACES WHERE COPPER A 12"0 4—WAY TITUS OMNI 24x24 MODULE SIZE WALL CAP EXHAUST FAN PIPING SHALL BE INSTALLED. project name B lo"o 4—WAY OMNI 24x24 MODULE SIZE M- MOUNTING EQUIPMENT C 6"� 2-WAY OMNI 24x24 MODULE SIZE PERMANENTLY MOUNTED ROOFTOP EQUIPMENT SHALL BE INSTALLED AS REQUIRED BY SOUTH FLORIDA BUILDING CODE (TABLE 34-D). D 6"0 1 -WAY TDC-AA AIR FLOW N- TEST & BALANCE E 6010 1-WAY PAS-AA 24x24 MODULE SIZE TEST AND BALANCE OF ALL EQUIPMENT SHALL BE PERFORMED BY AN INDEPENDENT TEST AND BALANCE F 8)10 2-WAY OMNI 24x24 MODULE SIZE COMPANY WITH A MINIMUM OF 5 YEARS EXPERIENCE IN PROJECTS OF THIS SIZE OR LARGER, bellgzza BACKDRAFT DAMPER THREE COPIES OF THE TEST AND BALANCE REPORT SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW. Spa • Salon • Boutique G 8 0 4—WAY PAS—AA 24x24 MODULE SIZE DETAIL AT WALL CAP EXHAUST FAN H 6110 1 —WAY PAS—AA 24x24 MODULE SIZE N.T.S. 7245 SW 57 CT 1 350FL 2424 RETURN REGISTER AIR FLOW Miami, FL DETAIL AT ROOF CAP project number 0 HVAC DESIGN REQUIRES YES NO N.T.S. 1-1/2" GALV. STRAP 0104-032 DUCT SMOKE DETECTOR X UNDERU AT ON(SSAPD SADDLE FIRE DAMPERS X d a t e SMOKE DAMPERS X 5/9/01 FIRE RATED ENCLOSURE X ASHRAE STANDARD 624989 OUTSIDE AIR CALCULATIONS FLEX. UL 181 revision FIRE RATED ROOF/FLOOR Project# 0104-032 SUPPLY DUCT DUCT 1 S/2/0� CEILING ASSEMBLY X A/C UNIT CABINET FIRE STOPPING X Date: 05109/01 1" GALV STRAP SPIN IN COLLAR SMOKE CONTROL X ANGLE UNDER DUCT W/ DAMPER PANDUIT STRAP FACTORY GASKET Name: BELLEZA WRAP TOPS OF CEILING DIFFUSER 18GA. GALV. 1 STRAP FIN. CLG. W/1/4"O x 1 ' FASTENERS 18 GA. FACTORY ROOF CURB CEILING DIFFUSER EACH CORNER ROOFING MATERIAL UNISTRUT OR ANGLE Q Address: 7245 S.W.56 CT MIAMI,FL. INSULATION 1" INSULATION drawn by UNISTRUT OR ANGLE FOR LEVELING ASHRAE STANDARD 62-1989 OUTSIDE AIR CALCULATIONS DUCT CONNECTIONS C.1=, 3/8"0 CARRIAGE BOLT W/PLATE Project# 0104-032 TO CEILING D11=FUSERS DETAIL sheet title WASHER TOP & BOTTOM AND DOUBLE Date: 05/09/01 Application: RETAIL AREA HEX NUT. 24" O.C. AT BASE OF NO SCALE CURB (TYP.) ROOF TRUSSES II II\ / //--�� e Name: BELLEZA Area: 239]sq.ft. Area factor: 40.00°� 1� Y Alm N®-}-I E J Occupancy: 30 P/1000 sq.ft. Total Occupancy: 29 People Address: 7245 S.W.56 CT MIAMI,FL. Outdoor Air F --Icfm/person Total Outside Air. 716 ch TA I 0500 lcfm/sq.ft. TYPICAL A C UNIT CURB DETAIL NO SCALE SCALE: AS 5HOUN NOTE: EXHAUST & SUPPLY FAN MOUNTING SIMILAR Application: BEAUTY SALON PREPARED BY: sheet number UCI Area: 1051 Is q.11. Area facto • ,,•;� f ,�" �t'� °, Engineering Inc. ft r. •'� I f:4 � ?3780 S.W. 56th Street, Suite 215 Occupancy: 25 P11000sq.it. Total Occupancy: 20 People `r- � '• 1Vian�i, Florida 33175 '� B1is. 305 383-8989 M = 2 711�'�= "P.4X (305) 383-9949 Q 'E-;MAIL: uciengObellsouth.net Outdoor Air 25 cfm/person Total Outside Air. 493 tint y �.. "��jj� �� �r i.e J. MIRANDA PE N0. 35579 s �7�'"r ,DAVID A. BELSKY PE NO. 37234 ' ��Io �rofessional Electrical/Mechanical 'c.y^ '"•.."...e.''`.°�,�• :EEngineers `.% .