Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
01-0679-010
Total I.Floor 'Area`= 3437 406 . ------INFILTRATION---------------------------_ "" ` CHECC Infiltration Criteria in 406 .1.ABCD have beenYmet ', ✓ MECHANICAL SYp_TEM_S CHECK ------------------- -- -- ------------- I --- HVAC load sizing has been performed:- (407'.4.ABCD) --- - -.--=-------------- 407 . ------COOLING SYSTEMS------------ -�'=�----- Type No,--Effkcidn'y ` IPLV ` Tons ---------------------------- --- ---------- ----- -------------- 1 . Single Package 1 13 5 .32 Z . Air Cooled ( >= 65, 000 Btu/h 1 11 12 10 .48 408 . ------HEATING SYSTEMS----------------------------------------------- --- Type No Efficiency BTU/hr -------------------------------- --- ---------- -------------- 1. Electric Resistance 1 1 35837 2 . Electric Resistance 1 1 50171 409- ------VENTILATION--------------------------------------------------- --- I CHECK Ventilation Criteria in 409.1.ABCD have been met. I ✓✓ 410 - -----AIR DISTRIBUTION SYSTEM---------------------------------------- --- CHECK - ---------------------------------------------- ------------- ------ --- --- Duct sizing and design have been performed. (410 .1.ABCD) I AHU Type I Duct Location R-value ----------------------------------- ---------------------- ------- 1 . Air Conditioners With Insulated Roof 6.5 2 . Air Conditioners With Insulated Roof 6 .5 CHECK - -------------------------------------------------------- --------- --- Testing and balancing will be performed. (410 .1.ABCD) 1 __�-7- 411. -----PUMPS AND PIPING-ZONE --------------------------------------- _-- Basic prescriptive requirements in 411.1.ABCD have been met. PLUMBING SYSTEMS 411 . -----PUMPS AND PIPING-ZONE 1--------------------------------------- --- Type R-value/in Diameter Thickness ------------------------- ---------- -------- --------- 411. -----PUMPS AND PIPING-ZONE 2--------------------------------------- --- Type R-value/in Diameter Thickness ------------------------ ---------- -------- --------- 1. Non-Circulating 0 .75 0 412 . -----WATER HEATING SYSTEMS-ZONE 1---------------------------------- --- Type Efficiency StandbyLoss InputRate Gallons ------------------------ ---------- ---------- ---------- ---------- 412 ------WATER HEATING SYSTEMS-ZONE 2---------------------------------- --- Type Efficiency StandbyLoss InputRate Gallons 1. -<=12 kW . 92 .00001 27 52 ELECTRICAL SYSTEMS CHECK 413 . -----ELECTRICAL POWER DISTRIBUTION---------------------------- ----- --- Metering criteria in 413 .1.ABCD have been met. .� 414 - -----MOTORS--------------------------------------------------- ----- ---