01-0610-021
Revisions: LIGHTING FIXTURE SCHEDULE GENERAL (VOTES SYMBOL LEGEND TYPE DESCRIPTION MANUFACTURER CATALOG No. LAMPS VOLTS MOUNTING REMARKS SYMBOL DESCRIPTION SYMB0L` ` " "` ` " " DESCRIPTION 1- INSTALLATION SHALL BE DONE IN STRICT ACCORDANCE WITH THE CEILING RECESSED FOLLOWING CODES: SFBC (1994), NFPA-70 (1999), NFPA-72 (1993), A INC. DOWNLIGHT KURT VERSEN C723-NF 1-150A21 120 NFPA-90A&B (1993), NFPA-99 (1993), NFPA-101 (1994) ""-" AND FAC59A3 (2000). I o � EXISTING FLUORESCENT LIGHTING FIXTURE ISOLATED SYSTEM, POWER/GROUND MODULE, SQ. 'D' # RN-120 --- -- o • SERIES 18" A.F.F. WITH FOUR RECEPTACLES 120V, 3W AND GROUNDING JACKS. SEE ISOLATION PNL. SCHEDULE FOR EDRSR-1403 2- ALL CONDUCTORS SHALL BE COPPER. EXISTING INCANDESCENT LIGHTING FIXTURE CONNECTION. RECEPTACLES SHALL BE HOSPITAL GRADE. RECESSED B ADJUSTABLE WALL WASH SPI 120-WH-MRI 1 -150T4DC 120 3- ALL CONDUITS SHALL BE E.M.T. UNLESS INDICATED OTHERWISE. SURGICAL LIGHT-INTENSITY CONTROL, WALL RECESSED 5'-0" _JH EXISTING WALL MOUNTED HID FIXTURE A.F.F. INSTALLED BY ELECTRICAL CONTRACTOR, FURNISHED 4- THE RECEPTACLES ON EMERGENCY POWER SHALL BE RED. BY ANOTHER SECTION OF SPECIFICATIONS. 5- PROVIDE TYPED CIRCUIT INDEX FOR PANELBOARDS. F-C--I FLUORESCENT STRIP LIGHTING FIXTURE WALL MTD,. THERMOSTAT FURNISHED AND ,INSTALLED UNDER MECH. SECTION; T WIRED AND CONNECTED BY ELECTRICAL CONTRACTOR. 7- ALL BOXES SHALL BE METALLIC. / ONWPLANSNG/WALL MTD. EXIT LIGHT, TYPE AS INDICATED DUCT MTD. SPACE HUMIDIFIER AS PER SCHEDULE ON A/C DWGS. 8- ALL RECEPTACLES SHALL BE 18" A.F.F. UNLESS INDICATED A 3 • OTHERWISE. A 3 FLUORESCENT/INCANDESCENT LIGHTING FIXTURE, CAPITAL DUCT MTD. SPACE HEATER; E-r T „ � O LETTER DENOTES TYPE, LOWER CASE DENOTES SWITCH CONTROL, � SEE SCHEDULE ON A/C DRAWINGS � 9- ALL ELECTRICAL SWITCHES SHALL BE 48 A.F.F. UNLESS b NUMBER DENOTES CIRCUIT NUMBER. (NORMAL BRANCH) INDICATED OTHERWISE. b A 3 PATIENT BED GROUNDING POINT, WALL MTD. 18" A.F.F. FLUSH. IBC 10 CONTRACTOR MUST VISIT SITE TO BECOME FAMILIAR WITH A FLUORESCENT/INCANDESCENT LIGHTING FIXTURE, CAPITAL EXISTING CONDITIONS BEFORE BIDDING THIS JOB. LETTER DENOTES TYPE, LOWER CASE DENOTES SWITCH CONTROL, }-� REFERENCE GROUNDING POINT, WALL MTD., FLUSH. ® w M 11- CONTRACTOR SHALL INSTALL ALL ELECTRICAL EQUIPMENT b NUMBER DENOTES CIRCUIT NUMBER. FIXTURE ON EMERGENCY M FURNISHED BY THE OWNER OR OTHER CONTRACTOR. b POWER. (CRITICAL BRANCH) CRT OUTLET CONSISTING OF A 4"X4" JUNCTION BOX WITH 12- COORDINATE ALL CONTROL WIRING FOR A.C. SYSTEM WITH THE A 3 A 3 FLUORESCENT/INCANDESCENT LIGHTING FIXTURE, CAPITAL u 3/4" CONDUIT STUB-UP ABOVE CEILING. MECHANICAL CONTRACTOR. PROVIDE ALL REQUIRED CONDUIT AND LETTER DENOTES TYPE, NUMBER DENOTES CIRCUIT NUMBER. WIRING AND 120V CIRCUITS FROM PANEL NL86 REQUIRED FOR 0 FIXTURE ON EMERGENCY POWER (LIFE SAFETY BRANCH) !-a PUSH BUTTON FOR AUTOMATIC DOORS WALL MTD. 4'-0" A.F.F. HVAC CONTROL CONTRACTOR. b b CONNECTED UNSWITCHED. 13- ALL CONDUITS SHALL RUN CONCEALED U.1-0, 00 DUAL HEAD EMERGENCY STAND-BY LIGHT, WALL MTD. INTERCOM EMPTY CONDUIT SYSTEM. BOX MTD. 54" A.F.F. < Oz 14- FURNISH AND INSTALL ALL REQUIRED E.C. SHOWN. E CONNECTED UNSWITHCED, TYPE AS INDICATED ON PLANS . �: j V 30 SAFETY DISCONNECT SWITCH, 30=SWITCH SIZE, 3=No. OF 15- PROVIDE COVER PLATES FOR ALL OUTLETS. 20A, 120/277VAC SINGLE POLE TOGGLE SWITCH, SPECIFICATIONS 3 15 POLES, 15=FUSE SIZE, O=NON FUSED 2 GRADE MTD. 4'-0" A.F.F. LETTER DENOTES LIGHTS SWITCHED. O 16- COORDINATE MOUNTING HEIGHT OF ALL LIGHTING FIXTURES WITH a RED IF CONNECTED ON EMERGENCY BRANCH. ARCHITECT. CB CIRCUIT BREAKER IN NEMA 1 ENCLOSURE WALL MTD. SURFACE 17- SUBMIT SHOP DRAWINGS FOR ALL LIGHTING FIXTURES FOR A E 20A, 120/277VAC„3 WAY TOGGLE SWITCH, SPECIFICATIONS ❑� 5'-0" A.F.F. SIZE & RATING AS INDICATEd ON PLANS. APPROVAL. / $3 RED IF CONNECTED DENOTES SWITCHED. MAGNETIC MOTOR STARTER WITH THERMAL OVERLOADS, MEMO NO i•r;:2 18- COLOR OF ALL LIGHTING FIXTURES FOR A/E APPROVAL. ® FVNR, NEMA 1 ENCLOSURE U.I.O. D DIMMER LUTON ATHENA 1200 WATT. MECHANICALLY-HELD LIGHTING CONTACTOR, NUMBER OF POLES AS O 19- PROVIDE ALL THE REQUIRED WIRING AND CONDUIT. z INDICATED IN PANELBOARD SCHEDULE. 20A CONTACTS, NEMA 1 1 20- ALL RECEPTACLES SHALL HAVE AN ENGRAVED BRANCH CIRCUIT 20A, 120/277VAC„ SINGLE POLE TOGGLE SWITCH, SPECIFICATIONS ENCLOSURE U.I.O. ASCO 917. 24 w 0 IDENTIFICATION PLATE. $k GRADE MTD. 4'-0" A.F.F. K DENOTES SWITCH WITH KEY TYPE OPERATION. 21- PROVIDE A GREEN GRID. WIRE TO ALL RECEPTACLES. 7c TIME CLOCK TORK # DG 100 20A, 125V, 3 WIRE GROUNDING TYPE SPECIFICATIONS 22- ALL FLUORESCENT FIXTURES SHALL USE ENERGY CONSERVATION GRADE DUPLEX RECEPTACLE, MTD. 18" A.F.F., U.I.O. PHOTOCELL HEAVY DUTY TORK # 2101. BALLAST AND LAMPS (GE OR SYLVANIA). EX RED IF CONNECTED TO AN EMERGENCY CIRCUIT. LETTERS "EX" INDICATE EXISTING. 23- THESE DRAWINGS SHALL BE REVIEWED AND APPROVED BY A.H.C.A. ' AUTOMATIC TRANSFER SWITCH ANY CHANGES OR A.H.C.A. RECOMMENDATIONS SHALL BE INCLUDED 20A, 125V, 3 WIRE GROUND TYPE SPECIFICATIONS GRADE ON THESE DRAWINGS OR ISSUED AS AN ADDENDUM TO THIS DUPLEX RECEPTACLE, MTD. 6" ABOVE COUNTERS OR 42" A.F.F. CONTRACT. RED IF CONNECTED TO AN EMERGENCY CIRCUIT. REMOTE GENERATOR ALARM ANNUNCIATOR PANEL. WALL 24- ALL BOXES AND ENCLOSURES INCLUDING CONDUITS OR EMERGENCY RP RECESSED 6'-0" A.F.F. CIRCUITS SHALL BE MARKED (SPOT PAINTED) AS FOLLOWS: o U BRANCH; 20A 125V, 3 WIRE GROUND FAULT INTERRUPTER DUPLEX ORANGE CRITICAL; GREEN, EQ IPMENT BRA CH; RED, FIRE �. " FIRE ALARM SYSTEM, IONIZATION TYPE CEILING MTD. SMOKE (z ALARM SYSTEM. RECEPTACLE, MTD. 6 ABOVE COUNTERS OR 42 A.F.F., � DETECTOR. 1� •� U.I.O. RED IF CONNECTED TO AN EMERGENCY CIRCUIT. 25- ALL CONDUIT PENETRATIONS OF FIRE-RATED WALLS, FLOORS, S❑ FIRE ALARM SYSTEM, DUCT MTD. IONIZATION TYPE DUCT w ; AND CEILINGS SHALL BE SEALED IN ACCORDANCE WITH D DETECTOR WITH SAMPLING TUBES. Lot o REQUIREMENTS OF N.E.C. ARTICLE 300-21. QUADRUPLEX RECEPTACLE, SAME AS ABOVE. •�aaA, , S❑ FIRE ALARM SYSTEM, DUCT MTD. IONIZATION TYPE SMOKE 26- ALL LIGHT SWITCHES SHALL HAVE AN ENGRAVED BRANCH CIRCUIT 20A, 125V, 3 WIRE GROUNDING TYPE HOSPITAL GRADE DD DETECTOR WITH SAMPLING TUBES AT SMOKE DAMPER LOCATION, IDENTIFICATION PLATE. DUPLEX RECEPTACLE, MTD. 36" A.F.F.,U.I.O. RED AS PER AC DWGS. Loll IF CONNECTED TO AN EMERGENCY CIRCUIT. 27- CONTRACTOR SHALL PROVIDE EQUIPOTENTIAL TEST FOR NEW RECEPTACLES FIRE ALARM SYSTEM, PHOTOELECTRIC TYPE CEILING MTD. SMOKE ❑ 0 AND HAVE EQUIPMENT READY AT TIME OF AHCA INSPECTION. P DETECTOR x 20A, 125V, 3 WIRE GROUNDING TYPE SPECIFICATIONS 28- CONDUIT TURNS TO HAVE LARGE, SWEEPING BENDS WITH MINIMUM GRADE DUPLEX RECEPTACLE, MTD. 48" A.F.F., U.I.O. =. -. RADIUS AS SPECIFIED IN NEC ARTICLE 346-10 RED IF CONNECTED TO AN EMERGENCY CIRCUIT. FIRE ALARM SYSTEM CEILING MTD. HEAT DETECTOR. (135-F) ;a 29- SEE SHEET E-5 AND E-6 FOR EQUIPMENT WIRING REQUIREMENTS. FIRE ALARM SYSTEM MANUAL PULL STATION, MTD. 20A, 125V, 3 WIRE GROUNDING TYPE SINGLE RECEPTACLE. MTD. 18" A.F.F., IN HEAD WALLS PROVIDE HOSPITAL GRADE 4'-0" A.F.F. 30- PROVIDE COMPARTMENTS IN DUCTS WHERE REQUIRED TO SEPARATE MTD. 36" A.F.F. RED IF CONNECTED TO AN EMERGENCY CIRCUIT. HIGH VOLTAGE, SIGNAL LOW VOLTAGE CABLES. COORDINATE FIRE ALARM SYSTEM COMBINATION HORN/STROBE (FLASHING RED) MTD. 80" A.F.F. COMPARTMENTATION WITH EQUIPMENT INSTALLER. 20A, 125V, 3 WIRE GROUNDING TYPE SPECIFICATIONS GRADE 31- PROVIDE PULL STRINGS FOR ALL EMPTY CONDUITS SHOWN DUPLEX RECEPTACLE, MTD. IN FLOOR., U.I.O. FIRE ALARM SYSTEM CHIME HORN/STROBE COMBINATION UNIT O SPECIAL RECEPTACLE OF NEMA TYPE AS INDICATED ON OF FIRE ALARM SYSTEM FLASHING LIGHT MTD. 80" A.F.F. 32- MRI SUITE DESIGN IS BASED ON SIEMENS MED-LAB PLANS. PROVIDE MATCHING PLUG DRAWINGS DATED 4/02/01, (REVISION #1 4/03/01) ® WL FIRE ALARM SYSTEM ELEVATOR WARNING LIGHT. 30A, 250V, 2-POLE, 3 WIRE GROUNDING SINGLE RECEPTACLE 33- INSTALLATION OF ALL WIRING SHALL BE DONE IN STRICT NEMA 6-30R. I0 FIRE ALARM REMOTE DUCT SMOKE DETECTOR INDICATOR LIGHT ACCORDANCE WITH MANUFACTURER REQUIREMENTS. ANALOG/DIGITAL INTELLIGENT LOOP SYSTEM. 34- ALL TROUGH TO BE SQUARE D, WALKER DUCT OR EQUAL FLOOR AND 30A, 125V, 3-WIRE GROUNDING TYPE SINGLE PHASE O 10 WALL TRENCH DUCT. SIZES TO BE SPECIFIED ON DRAWINGS. RECEPTACLE, 18" A.F.F. FACP FIRE ALARM CONTROL PANEL IRC-3 WITH ZAS-2 ' SEE SHEET E-5 AND E-6. WALL MOUNTED, EXTERIOR GRADE PLYWOOD TELEPHONE FIRE ALARM ANNUNCIATOR PANEL FAAP 35- GENERAL CONTRACTOR SHALL PAINT ALL EXPOSED AREAS OF EQUIPMENT BACKBOARD, SIZE 3/4 X 4 X 8 U.I.O., a o TROUGH. COORDINATE WITH OWNER AND ARCHITECT ON MATCHING PAINT FRONT BACK AND EDGES WITH FIRE-RESISTANT PAINT FS SPRINKLER SYSTEM FLOW SWITCH OR ACCENT COLOR. CI TELEPHONE OUTLET, MTD. 54" A.F.F. FOR PAY COIN TELEPHONE. TS SPRINKLER SYSTEM TAMPER SWITCH 36- EQUIPMENT INSTALLER SHALL PROVIDE A LIST OF CABLE USED P IDENTIFYING THE USE, CABLE TYPE, AND CLASS OF SYSTEM. ® CONTROL RELAY DPDT-24V DC IN NEMA BOX 37- GENERAL CONTRACTOR MUST FASTEN EQUIPMENT TO RACEWAY SYSTEM. BI TELEPHONE/DATA OUTLET, MTD. 6" ABOVE COUNTER. WITH CONTACTS. s WHERE FLEXIBILITY IS REQUIRED, FLEXIBLE METAL CONDUIT SHALL BE USED. C CM FIRE ALARM SYSTEM CONTROL MODULE w WHERE THE DEGREE OF FLEXIBILITY DOES NOT ALLOW THE USE OF METAL TELEPHONE/DATA OUTLET, MTD. 18" A.F.F. FOR DESK TYPE eta CONDUIT, MULTISTRANDED INSULATED COPPER CONDUCTOR MAY BE UTILIZIED. C USE U.I.O. MM FIRE ALARM SYSTEM MONITOR MODULE 4 38- ALL CONDUIT ENTERING MRI SUITE SHALL BE NON-FERRUS. TELEPHONE OUTLET MTD. 48" A.F.F. FOR WALL MTD. TELEPHONE. FIRE ALARM SYSTEM MAGNETIC DOOR HOLDER; SURFACE MTD. AND ��8 39- PROVIDE A MINIMUM OF THREE WIREWAY COMPARTMENTS TO ACOMODATE BH WIREHOLD SURFACE RACEWAY IF INSTALLED ON FIRE RATED WALL. h o� DIFFERENT TYPES OF CABLES. > FIRE FIGHTER PHONE JACK. F MGP MEDICAL GAS ALARM PANEL t+ -- CONDUIT RUN, EXPOSED OR CONCEALED AS INDICATED F-N-C-P7 NURSE CALL SYSTEM EQUIPMENT PANEL - - - - UNDERGROUND CONDUIT, 2'-0" MINIMUM BELOW GRADE 0 CONDUIT TURNED UP q91 M NURSE CALL SYSTEM MASTER STATION. O w CONDUIT TURNED DOWN NURSE CALL SYSTEM EMERGENCY STATION MTD. 3'-0" A.F.F. u WITH PULL CORD 2" A.F.F. -ys HOME RUN PANEL LP(I, CIRC##UIT # 3, TACK MARKS DENOTE fit I MARKS RN OF WIRES:SHORT MARKS HOT 1bR SQ. LONG LEGS, DOT NURSE CALL SYSTEM STAFF STATION WALL RECESSED 5'-0" ABBRE`' p p� A.F.F. OR 6 ABOVE COUNTER. VIATIONS MARKS GREEN GROUND WIRE EXHAUST FAN. NUMBER IN CIRCUIT DENOTES HORSE POWER I- D❑ NURSE CALL SYSTEM DUTY STATION MTD. 5'-0" A.F.F. RATING PB Uj PULL BOX SIZED PER NEC 91 F NURSE CALL SYSTEM FOOT SWITCH FOR O.R. STAFF STATION. A.F.F. ABOVE FINISHED FLOOR ` A.D.O. AUTOMATIC DOOR OPENER A.T.S. AUTOMATIC TRANSFER SWITCH J/ /� CEILING OR WALL MTD. JUNCTION BOX NURSE CALL SYSTEM PATIENT EMERGENCY STATION MTD. 4'-6" O O � ❑D BKR. BREAKER A.F.F. z O A.I.C. AMPERE INTERRUPTING CAPACITY C.B. CIRCUIT BREAKER I-© 20A, 125V, 3 WIRE CLOCK HANGER RECEPTACLE AND NURSE CALL SYSTEM PATIENT LIGHT CLG. MOUNTED C.CKT. CIRCUIT SPECIFICATION CLOCK, MTD. 7'-0" A.F.F. CAB. CABINET CBP CODE BLUE PANEL CONT. CONTRACTOR W CONN. CONNECT OS PUBLIC ADDRESS SYSTEM SPEAKER qfl CODE BLUE SYSTEM STATION LLJ CLG. CEILING V CL. CLOS COM. C MMUNICATION � W C.T. CURRENT TRANSFORMER �J PUBLIC ADDRESS SYSTEM DESK TYPE MICROPHONE CBA CODE BLUE ANNUNCIATOR WALL RECESSED 6'-0" A.F.F. m DWG. DRAWING E ELECT. DOO ❑ " J E. . ELECTRIC/ELECTRICAL EXHAUST FAN V a PUBLIC ADDRESS VOLUME CONTROL, MTD 48 A.F.F. E.C. EMPTY CONDUIT INDICATES AREA NOT IN CONTRACT. O EL. CL. ELECTRICAL CLOSET EM. EMERGENCY SURFACE WALL MTD. PANELBOARD m EMT ELECTRICAL METALLIC CONDUIT E.W.C. ELECTRIC WATER COOLER GEN. GENERATOR FLUSH MTD. PANELBOARD GRC GALVANIZED STEEL RIGID METAL CONDUIT FLU OR. FLUORESCENT LIGHTNING PROTECTION SYSTEM FLAT AIR TERMINAL. LETTER "A" co FLU Op GND. GROUND A INDICATES: WITH SWIVEL CONNECTOR. LETTER "B" INDICATES: G.F.I. GROUND FAULT INTERRUPTER CCTV SECURITY SYSTEM CLOSED CIRCUIT T.V. CAMERA WITH FLASHING SADDLE. G.T.B. GROUND TERMINAL BOX HT. HEIGHT H.P. HORSE POWER Fa SECURITY SYSTEM MONITOR H.C. HUNG CEILING p LIGHTNING PROTECTION SYSTEM PARAPET AIR TERMINAL HTR. HEATER J.B. JUNCTION BOX K.V.A. KILOVOLT AMPERES TV OUTLET MTD. 7'-0" A.F.F. TWO GANG BARRIED BOX WITH ANTENNA K.V. KILOVOLT TV OUTLET AND 20A, 125V RECEPTACLEII LIGHTNING PROTECTION SYSTEM DOWN LEAD GROUNDING CONDUCTOR K.W. KILOWATT MAX. MAXIMUM II MIN. MINIMUM DRAWN: Y:Cs/JjG/R.L M.C.B. MAIN CIRCUIT BREAKER PM 4" X 4" WALL OUTLET FOR PHYSIOLOGICAL PATIENT MONITORING - - - - LIGHTNING PROTECTION SYSTEM, HEAVY DUTY LIGHTNING CONDUCTOR MFR. MANUFACTURER SYSTEM (N.I.C.). EXACT OUTLET LOCATION TO BE COORDINATED AT THE CHECKED: JL.G./RR " MOD. MODEL FIELD. PROVIDE 1 E.C. WITH PULL STRING TO PULL BOX. SIZE AS MTD. MOUNTED AIC- AVAILABLE INTERRUPTED CURRENT NEC NATIONAL ELECTRICAL CODE REQUIRED IN THE CEILING SPACE ABOVE NURSES STATION. 65,000 AIC (EQUIPMENT PROTECTION VALVE) DATE: 05/10/2001 LTG. LIGHTING S.F.B.C. SOUTH FLORIDA BUILDING CODE 32,844 SCA SCA- SHORT CIRCUIT AVAILABLE SW SWITCH PS MEDICAL GASES PRESSURE SWITCH. PROVIDE CONTROL CONDUIT & WIRING (FAULT PRODUCED BY SHORT CIRCUIT) ro U.I.O. UNLESS INDICATED OTHERWISE TO EXISTING MEDICAL GASES ALARM PANEL AS INDICATED ON PLUMBING SCALE: AS SHOIIN WP WEATHERPROOF OR NEMA 3R ro UL UNDERWRITERS LABORATORIES DRAWINGS. o SERI NOTE: coxi ALL ABBREVIATIONS SHOWN ARE NOT NECESSARILY USED FOR THIS � PROJECT. Sv. RC R`J'� • `.I :.i ro t- THE Engineer Sheet NO. 3 10621 N.Kendall Drive. Suite 216 r; Miami, Florida 33176 0 CD (305) 27 -8083 EIM. ENG.: ME L CRUZ MG. 51901 m MECH. ENG.: ROBERT W. ROSNER REG. 38005 E Cu v RC# 21314 N JOB # 2102ro