01-0610-007 Revisions: ABLDG GOMMEN S 6/21/2001 FIN15H SCHEDULE JA TAILS T [DETAILS NON - RATED WALL SON5TRUCT I ON WALL TYPE GENERAL NOTE&: 0 I. GENERAL CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE APPROPRIATE A 1-1,41N �L�f D f NG BOTTOM OF FINISH STRUCTURAL DECK CONSTRUCTION OF ALL WALL TYPES AND COORDINATION OF ALL MECHANICAL, ROOM ELECTRICAL, PLUMBING AND EXISTING CONDITIONS ADJACENT TO SUCH WALLS. WAINSCOT CEILING SINCE THE WORK INVOLVES EXISTING-: BUILDING SYSTEMS AND FACILITIES, FLR. NO ROOM NAME FLOOR BASE WALLS REMARKS BOTTOM OF FIN. THE CONTRACTOR SHALL GIVE SPECIAL CONSIDERATION TO EXAMINATION OF MAT. HGT. MAT. HGT. SCHEDULED FINISH ON STRUCTURAL DECK /PAINTED ANY EXISTING CONDITIONS THAT WILL PREVENT THE CONSTRUCTION OF SUCH °ALL RATED WALLS AS PER PLANS. VARIATION OF TYPICAL RATED WALL TYPES 106 MRI SUITE VGT VINYL PAINT ACT s'-m' 2 METAL STUDS DETAILS SHALL BE ANTICIPATED AND SHALL BE EXPRESSLY INCLUDED AS 106A CLOSET VCT VINYL PAINT ACT 6'-0' CAULK(TYP.EACHSIDE) PART OF THE WORK WHENEVER REQUIRED, AT NO ADDITIONAL COST TO THE OWNER. A/E WILL SUPPLY THE DIFFERENT DETAILS FOR SUCH WALLS IF 1(d8 CONTROL ROOM * * * * * * EXISTING TO REMIAN DOORFRAME HOLLOW METAL FRAME SCHEDULE FINISH ON NEEDED. IGNORANCE ON THE PART OF THE CONTRACTOR WILL IN NO WAY 106A COMPUTER ROOM * * * * * * EXISTING TO REMIAN 1-va' VARIES 1-va' ONE LAYER 5/6' TYPE 'x" RELIEVE HIM OF THE OBLIGATIONS AND RESPONSIBILITIES ASSUMED UNDER 9 CLIPS PER JAMB GYPSUM WALLBOARD TH 1 S CONTRACT. EACH SIDE ON OF 6' METAL STUD Q 16' O.C. (TYP) 2. GENERAL CONTRACTOR SHOULD MARK ALL SMOKE WALLS /FIRE WALLS ABOVE THE CEILING WITH PAINT TO READ ACCORDING TO THE WALL RATING AS SUCH: LETTERS MUST BE 1 1/2' FOR HOLLOW METAL ONE HOUR WALLS AND 3' FOR TWO HOUR AND SMOKE WALLS AS FOLLOWS: FINISH & NOTE _ DOOR I_u rRAMED SMOKE: /FIRE WALL (PROTECT ALL PENETRATIONS) 1 1/2' (TYPICAL) C L NECO VINYL C 3, 3' TWO HOUR FIRE WALL (PROTECT ALL PENETRATIONS) a ° COMPOSITION GORi�IDOR CL_OSGT ONE HOUR CORRIDOR WALL (PROTECT ALL PENETRATIONS) > lu TILE(ANTI-STATIC VINYL INSERT(71-.) SURFACE)) HOUR SMOKE PARTITION (PROTECT ALL PENETRATIONS) 0 E-� I,ALL INTERIOR FINISHES SHALL MEET THE FOLLOWING REQUIREMENTS ALUMINUM THI;M84OL0 BY 4. PROVIDE 2" WIDE PAINTED RED LINE AT ALL STORAGE ROOMS, LOCATED 18' BELOW U RETURN CLOSED PEMCO'2006, V-41 SET �� ALL INTERIOR FINISHES SHALL BE CLASS "A'WITH FLAME SPREAD 0-25 AND SMOKE DEVELOPED 0-450. m - ENDS ON MASTIC(TYP) BOTTOM OF SPRINKLER HEAD/CEILING, WITH 2" HIGH RED LETTERS TO READ "NO STORAGE E�1 Nio r %/ ExISTI 0. ALL FLOOR FINISH IN CORRIDORS AND EXITS SHALL BE CLASS'I'MINIMUM 0,45 WATTS PER SQ.CM - =" FLOOR( ABOVE RED LINE". �1 gg//�/,' 7§ 5- PROVIDE PRESSURE TREATED FIRE-RETARDANT PAINTED WOOD SILL NAILER AT PERIMETER � EXCEPTIONS:CLASS'B" INTEJ21OR FINISH WITH FLAME SPREAD 26-75 AND SMOKE DEVELOPED 0-450 MAY BE USED IN SMALL INDIVIDUAL ROOMS OF NOT OVER 2' S/S• SOUND ATTENUATION BLANKET OF ALL ROOMS WITH WOOD BASE (SEE FINISH SCHEDULES) FOUR PERSONS CAPACITY, OTHER THAN EXITS AND ACCESS TO CORRIDOR EXITS. TO UNDERSIDE OF 6 STRUCTURE ® W M . ALL PARTITIONS SHALL BE 4° NOMINAL DIMENSION UNLESS OTHERWISE NOTED ON PLANS. 2,ALL WALLS E CEILING FINISHES TO BE CLASS'A"FINISH (0-25)FLAME. 5' EXISTING O CONCRETE SLAB INTERIOR WALLS, PERMANENT PARTITIONS (RATED OR NOT) AND TEMPORARY PARTITIONS SHOULD 3. INTERIOR FINISH IN CORRIDORS SHALL BE CLASS T. SCHEDULE BASE SUPPORT A MINIMUM OF l5J POUNDS PER SQUARE FOOT APPLIED PERPENDICULAR A ALL NEW GYPSUM WALLBOARD CEILINGS AND SOFFITS TO BE 5/8'TYPE'X'. TO THE WALL. 5.PROVIDE WATER-RESISTANT GYPSUM WALLBOARD IN ALL WET AREAS AND FINISH WITH ENAMEL PAINT I. PROVIDE BACKING SUPPORT AT ALL PARTITIONS WHERE EQUIPMENT IS INDICATED TO BE MOUNTED. < QI O 6.CONTRACTOR TO REPAIR,PATCH, AND REPAINT ALL DAMAGED FINISHES J-1 JAM DETAIL/HEAD SIM. (EXISTING) N.T.S. T-1 THRESHOLD DETAIL N.T.S. S. INSTALL METAL STUDS AT 16' O.C. WITH GYPSUM WALLBOARD HUNG VERTICALLY. ;/ AS REQUESTED IN ALL EXISTING REFINISHED AND REMODELED AREAS. O S. GENERAL CONTRACTOR TO VERIFY ANY EXISTING PARTITIONS WITH NEW WALL TYPE DESIGNATIONS 'C ' 7,ALL EXTERIOR PATCH UP WORK TO BE REPAIRED AND RESTORED TO MATCH EXISTING FINISHES AND COLORS. AND UPGRADE AS REQUIRED TO REFLECT NOTED WALL TYPE S. O V 8,ALL CORRIDOR WALL SURFACES ADJACENT TO PROJECT AREA ARE TO PAINTED OR CLEANED TO MATCH EXISTING. 10. SUPPORT OF SOFFITS FROM RATED PARTITION 15 APPROVED, ONLY IF THEY ARE ATTACHED DIRECTLY TO µ" 9,ALL EXISTING DOOR FRAMES IN AREAS WI-62E NEW WORK IS TO BE DONE, ARE TO RECEIVE NEW PAINT/STAIN AS SELECTED BY ARCHITECTANTERIOR DESIGNER METAL STUDS AND/OR STRUCTURAL BACKING: ONLY. ATTACHMENT TO GYP. WALLBOARD IS NOT ALLOWED. Moog OR OWNER. ° D I1. ALL EXISTING/NEW EXTERIOR MASONRY WALLS TO HAVE SCHEDULE SCHEDULE FINISH ON 5/8' TYPE "X' O 10, EXISTING AREAS TO BE RETAINED.PATCH AND REPAIR /REPLACE AS REQUIRED TO MATCH EXISTING ADJACENT FINISH, ° D ° , ° ONE - HOUR WALL COI �&TRUCT I OI � GYPSUM WALLBOARD ON 1-5/8' METAL STUDS AT 16' O.C. OVER RIGID INSULATION BOARD (TYPICAL AT 11. ALL CARPET ARE TO MEET OR EXCEED BAPTIST HOSPITAL STANDARDS, ROOM SIDE OF ALL FINISHED ROOMS ONLY). V 0 12, BASE TO MEET OR EXCEED BAPTIST HOSPITAL STANDARDS, MERCER,4" C-:;,4 F I L-E I,UP FACE of FINISHED WALL 12. ALL EXTERIOR MASONRY WALLS TO HAVE ONLY RIGID INSULATION AT ALL UNFINISHED ROOM SIDES. N a 13. VINYL FLOOR TILE TO MEET OR EXCEED BAPTIST HOSPITAL STANDARDS, ARMSTRONG OR WINDOW MULLION UNDERSIDE OF ! � ,...,= 14, CEILING TILE TO MEET OR EXCEED BAPTIST HOSPITAL STANDARDS, ARMSTRONG- CONC. SLAB 13. PROVIDE CONTINUOUS (UNINTERRUPTED BY FURRING) R-4.5 (MIN.)RIGID INSULATION BOARD AT ALL 15, CONTRACTOR TO PROVIDE SHOP DRAWINGS TO A/E FOR APPROVAL. BOTTOM OF FINISH STRUCTURAL DECK EXTERIOR BLOCK/CONCRETE WALLS FACING AIR CONDITIONED SPACES. INSTALL FROM FINISH SLAB TO V) UNDERSIDE OF STRUCTURAL DECK. GYPSUM WALLBOARD TO CONCEAL INSULATION TO UNDERSIDE OF �I w 16. ALL ACCESSORIES ARE TO MEET BAPTIST HOSPITAL STANDARDS. FINISHED STRUCTURAL DECK 0 17. ALL ACROVYN:COLOR: SEALANT(BOTH SIDES) ONE HOUR CONSTRUCTION NOTE 14. ALL DIMENSIONS SHOWN ON FLOOR PLANS ARE EITHER ROUGH (STUD TO STUD) OR MASONRY (MASONRY 18, DOORS FRAMES PAINTED TO MATCH BNM STANDARD (MASONRY TO MASONRY OR MASONRY TO STUD) TYPICAL U.O.N. Q CEILING BACK-UP STUD ONE LAYER 5/8" TYPE 'X' GYPSUM 15. IT IS THE INTENT FOR THE RATED BARRIER TO BE BUILT FIRST IN COMPLIANCE: WITH THE U.L. NO. AS QUOTED. WALLBOARD APPLIED AT RIGHT ANGLES ALL OTHER PARTITIONS ABUTTING RATED PARTITION SHALL NOT BE CONSTRUCTED UNTIL AFTER THE CEILING SUSPENSION SCHEDULED OF EXIST. STRUCT. OR PARALLEL TO EACH SIDE OF 3 5/8' RATED PARTITION 15 100'° COMPLETED. F 5CHEE) ULE SYSTEM TO UNDERSIDE CEILING MIN.METAL STUDS e 16' O.C. W/ 1" 16. IT IS REQUIRED THAT AFTER THE METAL STUD FRAMING 15 COMPLETED ON A RATED PARTITION THAT THE SCHEDULE FINISH ON TYPE S DRYWALL SCREWS 8' O.C.TO COMPANY PROVIDING THE SYSTEM INSPECTS AND CERTIFIES IN WRITING THAT THE FRAMING HAS BEEN DOOR SIZE DETAILS HOW. AUTO. ONE LAYER 5/8' TYPE "X' GYPSUM VERTICAL EDGES AND 12'O.G.TO TOP AND PERFORMED IN COMPLIANCE WITH THEIR REQUIREMENTS AND U.L. LABEL. SAME CERTIFICATION SHALL ROOM DOOR DOOR DOOR FRAME SET LABEL DOOR REMARKS WALLBOARD EACH SIDE OF METAL m BOTTOM RUNNERS AND INTERMEDIATE BE PROVIDED FOR GYPSUM WALLBOARD INSTALLATION, SCREWING AND TAPING. CONTRACTOR IS ° NO. NO. TYPE MAT. I"(,4T• A58EM. STUDS - STUDS.STAGGER ALL VERTICAL AND RESPONSIBLE FOR PLACING ELECTRICAL, MEDICAL GA5 AND OTHER OUTLETS AND BOXES IN SUCH A c U1TH. HG-cT. TH. JA"15 HEAD TRESH. No. (A D.) r HORIZONTAL JOINTS 16° o.c. EACH w 1� 106 A RF * �C * * ;�C �C �C { RF DOOR, BY RF CONTRACTOR -ACOUSTICAL STIPANEL AT 16"O.C. R 8' METAL STUDS cp SIDE AND OPPOSITE SIDES. (N.L.BJ FASHION AS TO NOT VIOLATE INTEGRITY OR STG RATING OF PARTITION. � 11. ALL EXISTING MASONRY WALLS OR CONCRETE COLUMNS IN AREAS AFFECTED BY NEW RENOVATIONS a 106A 106A B WOOD 5'-0' 6'-8' 1-3/8' ALUM. PICA ALUMINUM FRAME ONLY (U.L.. PILE NO. Pl"I UJP 45) SHALL RECEIVE SCHEDULED FINISH ON 5/S' TYPE 'X' GYPSUM WALLBOARD ON 1/5' METAL FURRING (° METAL ANGLE STRIP PROVIDE METAL STUDS AT cn l7 STRIPS AT 16° O.C. (TYPICAL UNLESS OTHERWISE NOTED ON PLANS). c 108 108 A WOOD 3'-0° 1'-0' 1-3/4' METAL J-1 J-I T-I FINISH TO MATCH WALLBOARD HORIZONTAL JOINTS W ANDEN PELT CONSTRUCT ON OF ALL WALLS I8. BLOCK UP ALL PENETRATIONS THROUGH EXISTING EXTERIOR WALLS DUE TO THE REMOVAL OF EXISTING 'I" SYSTEM W EQUIPMENT WITH RINKER TYPE T-18 OR T-11A, RE-STUCCO EXTERIOR FACE AND PAINT To MATCH EXISTING o w } TO VERIFY THAT CONSTRUCTION IS ADJACENT. (SEE MECHANICAL DRAWINGS) PERFORMED IN ACCORDANCE TO DOOFR 'T' RUNNER SUSPENDED ACOUSTICAL r NOTES SPECIFICATIONS ABOVE.ANY VARIATIONS CEILING TILE: SEE CEILING PLAN SHALL E3E BROUCzHT TO THE NOTE: CONTRACTOR TO PROVIDE WATER RESISTANT WALL BOARD IN ALL WET AREAS, AND ON ACTUAL DIM. 4 1/8' FOR 3 5/8" STUD X ALL TILED SURFACES. (TYPICAL) ACTUAL DIM. 1 1/4' FOR 6' STUD Q ,4RGHITEGTS ATTENTION. 1. GROUT ALL HOLLOW METAL FRAMES IN EXISTING/NEW CONCRETE BLOCK AND/OR POURED CONCRETE. ACTUAL DIM. 9 1/4' FOR 8' STUD E 2, ALL DOORS NOT MARKED ON FLOOR PLANS ARE EXISTING TO REMAIN. SOUND ATTENUATION BLANKET 4. PROVIDE 1/4" LABELED WIRE GLASS IN METAL FRAME, NOT TO EXCEED TO UNDERSIDE OF STRUCTURE SMO<E PARTITION RE QU I REMENT5: o 1,200 SQ.IN. MAXIMUM IN AREA PER LIGHT, AT ALL "C" LABELED DOORS WITH GLASS. 1 CEILING DETAILS N.T.S. 2 CEILING-� DETAILS N.T.S. SEALANT (BOTH SIDES) 5. ALL HARDWARE AND FRAMES SHALL MAINTAIN THE INTEGRITY OF THE FIRE RATING OF THE DOORS. A. SMOKE PARTITIONS SHALL BE CONTINUOUS FROM EXTERIOR WALL FINISH SLAB w 6. PROVIDE SMOKE TIGHT CAULKING AROUND ENTIRE PERIMETER OF FRAMES. TO EXTERIOR WALL. AT POINTS OF INTERSECTION WITH OTHER 1. USE DOUBLE (ATTACHED) 20 GAUGE METAL STUDS AT JAMB OF ALL DOOR OPENINGS IN METAL STUD PARTITIONS. PARTITIONS, THE INTEGRITY THE SMOKE WALL MUST BE S. CONTRACTOR SHALL NOTIFY ARCHITECT IF ANY EXISTING DOORS (FIRE RATED OR OTHEWISE) SECTION MAINTAINED AND THE INTERSECTING PARTITIONS BUTTED TO IT. THE SMOKE PARTITION 15 ALSO TO BE CONTINUOUS FROM J r ARE FOUND DEFECTIVE OR NOT MEETING STANDARDS SET IN THIS CONSTRUCTION DOCUMENT SET. TYPICAL ONE-HOUR FIRE-RATED PARTITION FLOOR SLAB TO UNDERSIDE OF STRUCTURE (SLAB) ABOVE. 9. CONTRACTOR SHALL FIELD VERIFY THICKNESS OF ALL EXISTING PARTITIONS ACCOMMODATING NEW DOORS O WITH SOUND ATTENUATION BLANKET B. IN SMOKE AND CORRIDOR PARTITIONS, ALL PENETRATIONS, J IN ORDER TO DETERMINE THE "THROAT" DIMENSIONS OF NEW FRAMES. EXISTING PARTITION TO BE UP-GRADED (AND/OR INCLUDING CONDUITS, A/C DUCTS ETC., MUST BE SEALED TO ; 10. SEE FLOOR PLAN FOR EXACT DOOR SWING. zA TO MATCH)ONE-HOUR FIRE-RATED,REFER TO MAINTAIN THE FIRE RATING INTEGRITY AS REQUIRED BY 11. NO KNOCK-DOWN FRAMES SHALL BE PERMITTED THROUGHOUT. ; FIRE TEST: FM WP-45,6-19-68 A.H.C.A. AND ALL GOVERNING AUTHORITIES. 12. FOR DOOR JAMB, HEAD AND SILL DETAILS, SEE SHEET A -3 EXISTING PARTITION WITH NEW LAYER OF 5/5' C. ALL DUCT PENETRATIONS OF SMOKE PARTITIONS AND FIRE METAL STUDS. ZB TYPE 'X' GYPSUM WALLBOARD ON NEW WORK O N SIDE OF ROOM ONLY 13, ALL WOOD DOORS TO BE SOLID CORE UNLESS OTHERWISE NOTED. RATED PARTITIONS MUST BE DAMPERED ACCORDING TO THE PAINTED SPECIFIC FIRE RATING REQUIRED: 14. ALL DOORS SHALL BE PROVIDED WITH A 5/8' UNDERCUT. MAXIMUM CLEARANCE BETWEEN THE BOTTOM 3/4' P.T. SMOKE PARTITIONS -COMBINATION 5.D./F.D. OF THE DOOR AND THE CONCRETE SLAB SHALL BE 3/4' MAX. EXCEPT AT THRESHOLD CONDITIONS, (SEE DETAL T-3) PLYWOOD 15. CONTRACTOR SHALL VERIFY SIZE OF ALL DOOR OPENINGS AND CONTACT THE FIRE TREATED 1 G� 1� III FIRE PARTITIONS -FIRE DAMPER C nn ARCHITECT IF ANY DISCREPANCIES ARE FOUND BEFORE ORDERING DOORS AND/OR FRAMES. METAL CORNER GUARD EXTERIOR I I A50 CRY WALL HORIZONTAL EXIT -COMBINATION SD./F.D. 4 o r 9 8 ACROSS SOFFIT. CORRIDOR WALL -SMOKE DAMPER o oa 16. ALL "B" LABELED STAIR DOORS TO BE 450° TEMP. RISE IN 30 MINUTES. FLOOR ASSEMBLY OR c - 1-1. USE LEVER HANDLES AT ALL LOCATIONS (EXCEPT AS OTHERWISE NOTED)-KNURLED LEVER HANDLES SHALL VERTICAL SHAFT -COMBINATION BE PROVIDED AT ALL TELEPHONE CLOSETS, MECHANICAL AND ELECTRICAL ROOMS. BOTTOM OF FINISH STRUCTURAL DECK HAZARDOUS ROOMS -COMBINATION S.D./F.D. "" 4 15. ALL GLASS IN RATED DOORS TO BE 1/4' WIRE GLASS IN APPROVED METAL FRAME (TYPICAL - U.O.N.) z o ALL GLASS IN NON-RATED DOORS TO BE I/4" CLEAR TEMPERED GLASS. LL D. ACCESS DOORS SHALL BE PROVIDED (FIRE RATED WHERE REQUIRED) V) V 19. DOOR NUMBERS CORRESPOND WITH ROOM NUMBERS FOR EASE OF IDENTIFICATION. SEE 0 a AND LOCATED IN THE INACCESSIBLE AREAS ADJACENT TO SMOKE Z ±r FLOOR PLANS FOR LOCATIONS. EXISTING = AND FIRE PARTITIONS TO ALLOW ALL PARTS OF PARTITIONS TO BE V h CONCRETE BEAM VISUALLY INSPECTED, MAXIMUM SPACING OF PANELS SHALL BE 30'. 4 a 20. CONTRACTOR TO PROVIDE BACKING FOR ALL DOOR STOPS ON G.W$. WALLS. d r �- BEE FLOOR PLANS FOR LOCATIONS. E• ALL PIPES, CONDUITS AND DUCTS AT ALL SMOKE/FIRE WALL A S. " Z 21. DOORS, JAMBS, AND TRIM TO BE PAINTED WITH DTM BONDING PRIMER INSULATION BOARD PENETRATIONS SHALL BE DONE AT 90 DEGREES ON BOTH SIDES. a: h A t,3 AND DTM ACRYLIC COATING PAINT. SEMI-GLOSS FINISH. (COLORS BY OWNER) � ti 3 CEILING DETAILS N.T.S. e F. ANY RECESSED ITEM IN THE 5MOKE PARTITION OVER 4'x4" MUST BE ENCASED �;, IN A FIVE SIDED 5/8 TYPE X GYPSUM WALLBOARD BOX. 3 F- z VISQUEEN VAPOR BARRIER CONTRACTOR 15 RESPONSIBLE FOR PROVIDING ADEQUATE BACK BOXING FOR ITEMS ED (EXCEEDING� � �� (EXCEEDING 16 SQ. IN.) RECESSED IN A FIRE PARTITION. 0 O (TYP.UDN) 8'x12' BONA BEAM h FINISH WALL OR BACKSPLASH SOFFIT(WHERE 2.5 TOP AND BOTTOM BACK BOXING SHALL BE OF SUCH CONSTRUCTION AS TO COMPLY WITH FIRE RATING VARIES CAULKING 2-0' APPLICABLE)SEE a REQUIREMENTS FOR THE PARTITION. 8/8' DRYWALL ON 1 12' X 3 12' (TYPICAL) INTERIOR ELEVATIONS MATCH EXISTING ► e WOOD STUD FRAMING a 16' O.C. STUCCO FINISH THESE ITEMS INCLUDE, BUT ARE NOT LIMITED TO: (3 1/2' VARIES ACCORDING TO FINISH STRIP(METAL) (SEE BUILDING ELEVATION'S) WALL THICKNESS) 5/8' TYPE 'X' / 2'-0'(TYP.UAN) I/4'HARDWOOD F 3/4 PLYWOOD ELECTRICAL JUNCTION BOXES MED. GAS OUTLETS, VALVE BOXES AND ALARM BOXES / 1 1/2' X 3 1/2' WOOD HEADER(3 12' TOP M9 LADDER TYPE GYPSUM WALLBOARD FIRE EXTINGUISHER CABINETS WATER COOLERS VARIES ACCORDING TO WALL BACKING 0 REINFORCEMENT THICKNESS) 3/4'PLYWbOD DECKING - a 18' TYPICAL ON 1/8' METAL FURRING FIRE HOSE CABINETS TELEPHONES AND SPLASH WITH PLASTIC 3/4'FIXED `� m 16' ON CENTER FILM ILLUMINATORS ACCESSORIES / 5UDING POCKET DOOR LAMINATE FINISH PLYWOOD SHELF PLYWOOD HARDWARE: STANLEY SET- 2826 WITH PLASTIC DOOR WITH 8' CMU WALL (ASTM C 90) B LAMINATE FINISH PLASTIC LAMINATE WITH TYPE S PORTLAND BASE (SEE FINISH SCHEDULED) 0 0 3/4' WOOD NAILER FINISH(BOTH SIDES) SEALANT - -8/S'PLYWOOD CEMENT/LIME/MORTAR \ FACING WITH s i PLASTIC LAMINATE FINISH SCHEDULED 's FINISH -3/4'ADJUSTABLE (n y (2 1/4'W VARIES ACCORDING ., 1 1/4'X 2 1/4' WOOD HEADER PLYWOOD ELF w 2'X4'WOOD WITH PLASTIC SECTION \ § o TO WALL THICKNESS) I / FRAMING LAMINATE FINISH u / 1/4'PLY REMOVIBLE ° o 0 3 AS SHOWN M..� PARA_ a i i 1/4'PLYWOOD /l O DOOR - SEE DOOR SCHEDULE w ENDS ° ° e " ■■�� O / f+1 WOOD BLOKING � 3/4'FIXED ° o iw NOTE- USE CONCRETE BLOCKS WITH 1900 pal � x FLUSH NET AREA COMPRESSIVE STRENGTH A W/ ACROVYN LOUVERED w WITH PLASTIC SHELF w (F'm= 1500 pal) r , KICK PLATE DOOR SCHEDULE 'U', WITH PLASTIC ; V U�r FINISH WALL LAMINATE FINISH FRAME HEAD RABBET (COLOR TO BE SELECTED 15Y ARCHITECT/OLLNER ACROVYN SCHEDULE FLOOR o o PRIOR TO ORDERING. AND BASE 3/4'X I In'WOOD [� O o 0 o_J LLj TREATMENT AREA 2x44 Wool) SINK CABINET BLOCKING HINGE A DOOR PROTECTION MODEL 2-DP -LENGTH OF COVER AT DIM-B TO SUPPLIED OVERSIZE FOR FIELD RIM N CABINET GENERAL NOTES sEEDiMPJ R I. USE PLASTIC LAMINATE ON COUNTERTOPS, BACKSPLASHES AND ALL EXPOSED EDGES. ELEVAMO S C DEADLOCK STRIKE 2. WHERE CABINET END ABUTS A WALL, PROVIDE 5ACK5PLASH, 6' HIGH UNLESS OTHERWISE aHosp ITA pRM LL NOTED ON INTERIOR ELEVATIONS. (PLOSHHEPRLATE AAN D 3. BACKSPLASH AND COUNTERTOP ARE CONTINUOUS, AS SHOWN ON INTERIOR ELEVATION. pr SEE INTERIOR o HINGE m PUSH BAR AND PULL �ELEVATIONS 4. PROVIDE CONTINUOUS SEALANT ALONG TOP OF BACK5PLASH AT WALL. 0 STRIKE FOR KNO LOCKS,HANDLE SPs. 5. GENERAL CONTRACTOR TO VERIFY ALL DIMEN5ION5 AT FIELD, COORDINATE ALL Ex°IT DEVICEBHES t EQUIPMENT INSTALLED IN CABINETS, AND SUBMIT SHOP DRAWINGS TO ARCHITECT FOR DRAWN: VC HINGE APPROVAL PRIOR TO FABRICATION. s wr wE A-- 6. REFER TO 1/4' FLOOR PLANS AND INTERIOR ELEVATIONS FOR MODIFICATIONS. CHECKED: LEN a 0 1. ARCHITECT/ INTERIOR DESIGNER TO SELECT COLOR OF ALL CABINET FINISHES. N 8. REFER TO SHEETS A-2 INTERIOR ELEVATION. DATE: 5/10/2001 9. ALL INTERIOR CABINET FINISHES TO HAVE PLASTIC LINERS (TYPICAL UNLESS m HINGe - OTHERWISE NOTED.) SCALE: N.T.S. 10. REFER TO INTERIOR ELEVATIONS FOR INDICATION OF LOCKABLE OR NON- LOCKABLE DOOR FEATURES. REFER TO SPECIFICATIONS FOR MATERIALS, LOCKS AND HARDWARE. FRAME 11. NO CABINETS ARE TO BE SUPPORTED OR HUNG FROM ANY FIRE RATED PARTITION. SEA CABINETS WILL BE HUNG FROM THE SOFFIT ABOVE OR SUPPORTED BY ADJACENT NON- T A22 THERMOFORMED RATED PARTITIONS. SEE FLOOR PLANS FOR EXACT LOCATION OF FIRE RATED PARTITIONS. <c�` SCHEDULED FLOOR BOTTOM ACROVYN COQ 12. PROVIDE EASED CORNER EDGES AT ALL CABINET TOPS ABUTTING A WALL. OF FRAME DETAIL AT HINGE ` ° { 13. ALL CABINETS ARE TO BE CONSTRUCTED OF GRADE "A° PLYWOOD AND ARE TO BE its DOOR IN CLOSED POSITION FASTENED TOGETHER WITH SCREWS. , `. 3 TYi�IC,41_ DOOR DETAIL T�I'i�IC,4L DOOR GU)4RD DET/4I1. N.T.S. CABINET OR A FULPLENGTH LEGDUPPORT. SEE TYPICAL DETAIL. BY A BASE N.T.S. �'', z °a o g a •N G( '` 15. MILL WORK MANUFACTURER SHALL INSTALL ONE PLASTIC GROMMET PER EACH ELECTRICAL RECEPTACLE, TELEPHONE OUTLET, GIRT, OUTLET Er-T. SPECIFIED ON THE EQUIPMENT PLANS AND/ OR ELECTRICAL DRAWINGS. INSTALL WITHIN THE KNEE SPACE E" OF ALL CABINETS SHOWN ON EQUIPMENT DRAWINGS. ao 16. GENERAL CONTRACTOR SHALL COORDINATE ANY NECESSARY ACCESS REQUIREMENTS Sheet 1\1 Ai o N° IN CABINETRY. ACCESS DOORS AND/OR ACCESS PANELS SHALL BE INCLUDED AS PART OF THE CABINET WORK WHEN NECESSARY TO INSTALL AND/OR SERVICE ANY TYPE OF s° MECHANICAL, PLUMBING OR ELECTRICAL DEVICE THAT IS CONGEALED BY THE CABINETRY. A-4 o� N N N C OF a' O 8 ' C ` v 7 0 JOB 1r, 2126