Loading...
11-06-07 Item 13 Plan (8)►a C ■i E GENERAL CONDITIONS 1. THESE SPECIFICATIONS AND CONSTRUCTION DRAWINGS ACCOMPANYING THEM DESCRIBE THE WORK TO BE DONE AND THE MATERIALS TO BE FURNISHED FOR THE CONSTRUCTION OF THE T- MOBILE FACILITY. 2. BEFORE BEGINNING WORK AT THE SITE INSPECT THE EXISTING BUILDING AND DETERMINE THE EXTENT OF EXISTING FINISHES SPECIALTIES, EQUIPMENT AND OTHER ITEMS THAT MUST BE REMOVED AND REINSTALLED IN ORDER TO PERFORM THE WORK UNDER THIS CONTRACT. 3. THE ENGINEERING DRAWINGS SHOW PRINCIPAL AREAS WHERE WORK MUST BE ACCOMPLISHED UNDER THIS CONTRACT. INCIDENTAL WORK MAY ALSO BE NECESSARY IN AREAS NOT SHOWN ON THE ENGINEERING DRAWINGS DUE TO CHANGES AFFECTING EXISTING ELECTRICAL OR OTHER SYSTEMS. SUCH INCIDENTAL WORK IS ALSO A PART OF THIS CONTRACT. INSPECT THOSE AREAS AND ASCERTAIN WHAT IS NEEDED TO DO THAT WORK IN ACCORDANCE WITH THE CONTRACT REQUIREMENTS AT NO ADDITIONAL COST. 4. SHOULD ANY ERROR OR INCONSISTENCY APPEAR IN THE DRAWINGS OR SPECIFICATIONS, THE CONTRACTOR BEFORE PROCEEDING WITH THE WORK MUST MAKE MENTION OF THE SAME TO AW SOLUTIONS AND OWNER FOR PROPER ADJUSTMENT AND IN NO CASE PROCEED WITH THE WORK IN UNCERTAINTY OR WITH INSUFFICIENT DRAWINGS. 5. THE INTENTION OF THE DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS REASONABLY NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK AS STIPULATED IN THE CONTRACT. 6. THE CONTRACTOR AND EACH SUBCONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL MEASUREMENTS AT THE SITE BEFORE ORDERING ANY MATERIALS OR DOING ANY WORK. NO EXTRA CHARGE OR COMPENSATION SHALL BE ALLOWED DUE TO DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND DIMENSIONS INDICATED ON THE CONSTRUCTION DRAWINGS. ANY SUCH DISCREPANCY IN DIMENSIONS WHICH MAY BE FOUND SHALL BE SUBMITTED TO AW SOLUTIONS AND THE T- MOBILE REPRESENTATIVE FOR CONSIDERATION BEFORE THE CONTRACTOR PROCEEDS WITH THE WORK IN THE AFFECTED AREAS. 7. THE PURPOSE OF THESE SPECIFICATIONS IS TO INTERPRET THE INTENT OF THE DRAWINGS AND TO DESIGNATE THE METHOD OF THE PROCEDURE, TYPE AND QUALITY OF MATERIALS REQUIRED TO COMPLETE THE WORK. 8. TRADE, PRODUCT NAMES OR MANUFACTURERS NAMES OR CATALOG NUMBERS AND INDICATIONS OF PRODUCT TYPES SUCH AS (DUCT SEAL) SHOWN ON THE DRAWINGS OF EXISTING PRODUCTS ARE BELIEVED TO BE ACCURATE. IF THEY ARE DISCOVERED TO BE INACCURATE, NOTIFY AW SOLUTIONS IMMEDIATELY AND DO NOT PROCEED WITHOUT INSTRUCTIONS. 9. DIMENSIONS TO EXISTING SURFACE ARE TO FINISHED FACE. 10. DO NOT DRILL OR CUT EXISTING FLOOR JOISTS, BEAMS COLUMNS OR OTHER STRUCTURAL ELEMENTS UNLESS SPECIFICALLY INDICATED. DRILL SLABS WHERE APPROVED. CORE DRILL CIRCULAR OPENINGS THROUGH CONCRETE SLAB. LINE DRILL FOR RECTANGULAR OPENINGS. MAKE OPENINGS OF PROPER SIZE FOR CONDUIT, DUCTS, PIPES AND OTHER ITEMS PASSING THROUGH OPENINGS. MAKE ALL NEW HOLES ON OPENINGS WEATHER TIGHT OR FIRE SAFE AS REQUIRED BY LOCAL BUILDING CODES & ORDINANCES. 11. PREPARE, SUBMIT AND RECEIVE APPROVAL OF SLEEVES AND OPENING DRAWINGS BEFORE LOCATING SLEEVES AND OPENINGS IN NEW CONSTRUCTION AND BEFORE DRILLING EXISTING STRUCTURE. SHOW EACH OPENING AND SLEEVE IN THE ENTIRE PROJECT. 12. REPAIR, PATCH, FINISH AND /OR REFINISH AS APPLICABLE TO MATCH ADJACENT EXISTING FINISHES THOSE EXISTING SURFACES DAMAGED OR NEW PROPOSED SURFACES DURING PERFORMANCE OF THE WORK UNDER THIS CONTRACT. 13. WHERE CUTTING OF EXISTING SURFACES OR REMOVAL OF EXISTING FINISHES IS INDICATED, REQUIRED TO PERFORM THE WORK UNDER THIS CONTRACT AND A NEW FINISH IS NOT INDICATED, FILL RESULTING OPENINGS AND PATCH THE SURFACE AFTER DOING THE WORK AND FINISH TO MATCH ADJACENT EXISTING SURFACES. 14. EXCEPT IN SPACE WHERE NO WORK UNDER THIS CONTRACT IS REQUIRED, ENCLOSE EXISTING AND NEW CONDUITS, DUCTS, PIPES AND SIMILAR ITEMS IN FURRING WHERE SUCH ITEMS PASS THROUGH FINISHED SPACES WHETHER OR NOT FURRING IS INDICATED. 15. WHERE CONDUITS, DUCTS, PIPES AND SIMILAR ITEMS ARE SHOWN TO BE INSTALLED IN EXISTING WALLS OR PARTITIONS NEATLY CHASE THE WALLS OR PARTITIONS. INSTALL THE ITEMS AND PATCH THE WALLS OR PARTITIONS TO MAKE THE INSTALLATION NOT DISCERNIBLE IN THE FINISHED WORK. 16. SEAL WATER TIGHT AND PROTECT WITH FIRE SAFING MATERIALS FOR NEW SLEEVES AND OPENINGS THROUGH ROOFS, FLOORS AND IN VERTICAL CHASES AS REQUIRED BY CODE AND INDUSTRY STANDARDS. 17. WHERE A NEW CUTTING IS NOT SCHEDULED, INSTALL NEW CONDUITS AND PIPES IN EVERY CASE, AND NEW DUCT WHERE POSSIBLE ABOVE EXISTING CEILING. REMOVE EXISTING CEILING AS NECESSARY. AFTER INSTALLATION OF CONCEALED WORK, REINSTALL REMOVED CEILING AND PATCH AND REFINISH TO MATCH ADJACENT UNREMOVED CEILINGS. 18. NOISE AND EXISTING BUILDING STRUCTURE VIBRATION GENERATED BY CONSTRUCTION PROCEDURES, EQUIPMENT, TOOL AND OPERATIONS ARE TO BE KEPT TO A PRACTICABLE MINIMUM. WHERE USE OF HIGH NOISE LEVEL EQUIPMENT IS UNAVOIDABLE, AND CAN BE HEARD, CONFINE TO HOURS BEFORE 10 A.M. AND AFTER 5 P.M. MONDAY THROUGH FRIDAY OR AS AGREED TO BY BUILDING OWNER. 19. DAY -BY -DAY CLEANUP: REMOVE STAINING OR REACTIVE MATERIALS FROM NEW AND EXISTING SURFACES IMMEDIATELY. REMOVE HAZARDOUS ACCUMULATIONS OF DEBRIS PROMPTLY, AT LEAST DAILY. CONFINE DUST PRODUCING OPERATIONS DURING PAINTING AND FINISHING. THERE SHOULD BE NO OVER SPRAYING PAINT IN PARKING AREA. VACUUM IMMEDIATELY AFTER COMPLETION. 20. CONSTRUCTION SITE ACCESS: USE MOST DIRECT ROUTE FROM PUBLIC STREET AS AGREED TO BY BUILDING OWNER. FOR ACCESS TO EXISTING BUILDING INTERIOR USE LOADING DOCK AS AGREED TO BY BUILDING OWNER. 1 2 R 21. FOR TEMPORARY USE OF EXISTING ELEVATOR, SUBMIT FOR APPROVAL A LIST OF THE PROCEDURES PROPOSED TO PROTECT EXISTING ELEVATOR FROM HARM DURING USE. PROTECT CAB, ENTRANCES AND ADJACENT SURFACES FROM DAMAGE. DO NOT OVERLOAD ELEVATOR. MAINTAIN ELEVATOR DURING USE AND RETURN TO ORIGINAL CONDITION AT COMPLETION. 22. CONSTRUCTION PERSONNEL MAY USE EXISTING STAIRS AND CORRIDORS FOR CONSTRUCTION PURPOSES. PROTECT STAIR AND ACCESS WAYS AND RETURN TO ORIGINAL CONDITION AT COMPLETION. COORDINATE WITH BUILDING OWNER FOR USE OF WASHROOM FACILITY. 23. PROVIDE PROPER TEMPORARY PROTECTION OF HIGH TRAFFIC AREAS. 24. AT PROJECT COMPLETION, REMOVE TEMPORARY SERVICES, CONSTRUCTION EQUIPMENT, TOOLS AND FACILITIES, MOCKUPS, TEMPORARY STRUCTURES. SURPLUS MATERIALS, DEBRIS, AND RUBBISH FROM BUILDING OWNERS PROPERTY. PUT SITE IN NEAT, ORDERLY CONDITION, READY FOR USE. LEAVE ROOF AREAS, PIPE SPACES AND OTHER SPACES CLEAN AND FREE FROM DEBRIS ON A DAILY BASIS. 25. RELATED DOCUMENTS AND COORDINATION: GENERAL CARPENTRY, ELECTRICAL, AND ANTENNA DRAWINGS ARE INTERRELATED. IN PERFORMANCE OF THE WORK, EACH CONTRACTOR MUST REFER TO ALL DRAWINGS. ALL COORDINATION TO BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 26. SHOP DRAWINGS (ARE REQUIRED): A. CONTRACTORS TO SUBMIT SHOP DRAWINGS AS REQUIRED AND LISTED IN THESE SPECIFICATIONS THROUGH THE GENERAL CONTRACTOR TO AW SOLUTIONS FOR APPROVAL. B. ALL SHOP DRAWINGS TO BE REVIEWED, CHECKED AND CORRECTED BY GENERAL CONTRACTOR PRIOR TO SUBMITTAL TO AW SOLUTIONS. AW SOLUTIONS WILL RETURN SHOP DRAWINGS TO GENERAL CONTRACTOR WITHIN 3 WORKING DAYS OF RECEIPT. DO NOT PERFORM WORK BEFORE APPROVAL OF SHOP DRAWINGS. 27. THE SUBCONTRACTOR MUST VERIFY ALL DIMENSIONS, CONDITIONS AND ELEVATIONS BEFORE STARTING WORK. ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE ENGINEER AND SHALL BE RESOLVED BEFORE PROCEEDING WITH THE WORK. ALL WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER IN ACCORDANCE WITH ACCEPTED CONSTRUCTION PRACTICES. 28. IT IS THE INTENTION OF THESE DRAWINGS TO SHOW THE COMPLETED INSTALLATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL TEMPORARY BRACING, SHORING, TIES, FORMWORK, ETC. IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL ORDINANCES, TO SAFELY EXECUTE ALL WORK AND SHALL BE RESPONSIBLE FOR SAME. ALL WORK SHALL BE IN ACCORDANCE WITH LOCAL CODES. 29. SUBCONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY THIS REQUIREMENT APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 30. ALL WORK SHALL COMPLY WITH OSHA AND STATE SAFETY REQUIREMENTS. 31. CORE LOCATIONS IF REQUIRED SHALL BE CHOSEN SO AS TO AVOID CUTTING ANY REINFORCING BARS. FIRESTOP FLOOR OR WALL PENETRATION WITH TWO HOUR RATED SEALANT TO MEET UL CAJ5045. PROVIDE WEATHERPROOFING OF ANY ROOF PENETRATIONS 32. ALL WORK PERFORMED & MATERIAL USED SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF THE LATEST EDITION OF THE FLORIDA BUILDING CODE. 4 5 I I ABBREVIATIONS & LEGEND ACLC EXISTING PROPERTY LINE ATS PROPOSED LEASE LINE X EXISTING FENCE C EXISTING CONTOUR COAX EXISTING EDGE OF FENCE ❑H EXISTING OVERHEAD UTILITY LINE O IRON FENCE Q� IRON ROD SET 5/8" ro, UTILITY POLE C GUY ANCHOR ® WATER METER E. S. EXISTING TREE FT. BENCH MARK H SANITARY SEWER MANHOLE IN. FLOW DIRECTION ® SHUT OFF VALVE ® FIRE HYDRANT ABBREVIATIONS & AND ACLC ALTERNATING CURRENT LOAD CENTER ATS AUTOMATIC TRANSFER SWITCH DIA DIAMETER C CENTER LINE COAX COAXIAL CABLE CONC. CONCRETE CONT. CONTINUOUS C. J. CONTROL JOINT DIA. DIAMETER DWG DRAWING EL. ELEVATION E. S. EACH SIDE FT. FEET HORIZ. HORIZONTAL IN. INCH MAX MAXIMUM MFR. MANUFACTURER MIN MINIMUM MPH MILES PER HOUR R PLATE REQ'D REQUIRED SIM. SIMILAR STD. STANDARD STL. STEEL TYP. TYPICAL U.N.O. UNLESS NOTED OTHERWISE W/ WITH W. G. WAVEGUIDE I i APPLICANT /OWNER: a LN u sb Get more from hfd T- Mobile USA, Inc 8100 SW 10th Street Plantation, FL 33324 Phone: (954) 693 -7172 Fax (954) 693 -7240 PREPARED BY: ff�s�m A "00 Wsolutsions I n c o r p o r a t ad 300 CROWN OAK CENTRE DRIVE LONGWOOD, FL 32750 TELL 407.260.0231 FAXL 407.260.0749 FL. COA# 26983 IREVIREV ISIONS DATE I DESCRIPTION 1 1 9/24/071 REVISED SITE NAME 0 1 6/7/06 ISSUED FOR ZONING B 6/5/06 REVISED PER ZONINIG A 4/13/06 ISSUED FOR REVIEW SEAL EMMANUEL POULIN FL. P.E. #54073 IT IS A VIOLATION CF LAW FCF' AIli PEP1,N] UIILE`_S THE, ARE ACTfTIG LI -1EEP THE DIPE(-TI011 )F 4 Lk EASED F'Pt�FE`_SIC�1lAL EPIGINEEP TO ALTER THIS D CIJt.lEilf IJIILE-'S E•PLII.ITLi AGREED TO Et Ill `APITH:(:, A1V �' U.1110I11 DGCL ALL LIAEILIT� A'= Sir ".IATED 141711 fllE PEIP-E, AL1FF'AT =� t] �,P G "ODIFICATIC�II CF IIIL _ flTEtIT'- HEF'E'11. NOT VALID WITHOUT SIGNATURE & SEAL PROJECT LOCATION: SITE #M D 1277 GULLIVER SITE 8512 SW 57TH AVENUE SOUTH MIAMI, FL 33156 ROOFTOP DRAWN BY: SB CHECKED BY: SE DATE: 05/16/06 JOB NO. : 120.005 SITE NO. : MD1277 DRAWING DESCRIPTION: GENERAL NOTES DRAWING NUMBER: Z2