01-0482-008 GENERAL ELECTRICAL NOTES ,�.L �a G -1' ;I x.•41_ 1_ rJ.4L7 CC�ivii�l�T.4T f 01�! I.DO NOT SCALE ELECTRICAL DRAWINGS,REFER TO ARCHITECTURAL DRAWINGS AND ACTUAL (3) 04 CU. IN IN MiC. 0iv MOTOR LOAD) FIELD CONDITIONS FOR LOCATION OF ALL NEW AND EXISTING EQUIPMENT;CONFIRM WITH OWNERS REPRESENTATIVE. EXIST. THR>= PHASE SPRAY BOOTH 2.ALL WORK SHALL BE DONE IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE(NEC),SOUTH SPRAY 200A 34 •EXHAUST FA -4.i45 RFM,?� V, 26 A, 10 NP. 260 A FLORIDA BUILDING CODE AND SHALL APPLY WITH ALL LOCAL RULES AND ORDINANCES. 500TH 24m V INtAICE'FAN 1, 4Pi � NOTHING M THESE DRAWINGS/SPECIFICATIONS IS TO BE CONSTRUED TO PERMIT WORK NOT CONTROL "� ,j' r'I;,ar+rQ �, 26 A, Im N.P. 260 A CONFORMING TO THESE CODES,RULES AND ORDINANCES. I PANEL P' L TOTAL X30 52.0 A 3.MNiMUM WUtE SIZE SHALL.BE#I2AVG,EXCLUDING CONTROL WIRING. UNLESS OTHERWISE LIGHTING 10 SPRAY BOOTH NOTED ALL CONDUCTORS SHALL BE COPPER WITH THE INSULATION. FLUORESCENT LIGHTS mB A EA x 23 22.4 A 4.OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS.CAST ALLOY WITH THREADED HUBS IN WET OR DAMP LOCATIONS AND SPECIAL ENCLOSURES FOR OTHER CLASSIFIED AREAS. (3)slm CU. N V2" M.G. (1.-, Li:�NTING LOAD/'/ (2)°1Z•a' IN v2' M.G. F�.;r1T MIxMG ROOM to 5.ALL. NEW CONDUCTORS SHALL BE RUN IN METAL CONDUITS. 1F'PVC'SCH.401S USED FOR 1/3 H.P. Mc T oR ('ANT MIXIW-, R!"1. INTAKE FAN 203m R.P.M. 23m V, 3b A, 1/3 NP. 3b A •- UNDERGROUND FEEDERS,AN EQUIPMENT GROUND CONDUCTOR SIZED IN ACCORDANCE WITH FLUoFESCENT LIGHTS 0.8 A EA X 2 Ib A J ` NEC 250.95 14UST BE INSTALLED AND CONDUIT SIZE INCREASED AS REQUIRED. LIGHTNG PAINT MIXINcz RGOt"i 6.ELECTRICAL SYSTEM SHALL BE COMPLETE AND EFFECTIVELY GROUNDED AS REQUIRED BY 1'1 i1: vy LATEST EDITION OF THE NEC. L ��' C P q IA�---%_ = G r --T L_ 14 7.DISCONNECT SWITCHES SHALL BE H.P.RATED,HEAVY DUTY,QUICK-MADE,QUICK-BREAK; LOAD UJIRE TRIP I POE VIA ENCLOSURES AS REQUIRED BY EXPOSURES. S.MOTOR STARTERS SHALL BE MANUAL OR MAGNET,WITH OVERLOAD RELAYS IN EACH HOT LEG. Cs�� I � I N.T.S. A 3m 4.ALL MATERiA1.SHALL BE NEW AND BEAR UNDERWRITER'S LABELS WI IE1tE APPLICABLE. Y 500TH 10 LOAD (LIGHTING) '1m.4 .10 3 2161 10.TYPEWRIT 7 EN PANEL TALLY SHALL'BE FURNISHED AFTER JOB IS COMPLETED,REFLECTING ALL -4 Y IX 30 (MOT ) 62 CHANGES AND ADDITIONS FOR NEW AND EXISTING PANELS. P r x la LOAD l IGi-i7NG) 20 2 e64 b-'T PANT MIXWz W. 10 LOAD (MOTOR) 11.IT 1S NOT THE INTENT OF THESE DRAWINGS TO SHOW EVERY MINOR DETAIL OF :. CONSTRUCTION. THE ELECTRICAL CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL.ALL - ITEMS FOR A COMPLETE ELECTRICAL SYSTEM AND PROVIDE ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. toT 33m AL v A 12.EXACT POINTS AND METHODS OF CONNECTIONS SHALL BE DETERMINED ON THE SITE. 13.ALL WORK SHALL BE PERFORED BY A LICENSED ELECTRICAL CONTRACTOR 1N A FIRST CLASS T PS. -Y' M WORKMANLIKE MANNER,THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE,AND ACCEPTED 1 BY ARCHITECT AND ENGINEER. 14.ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. 15.THE E. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FROM A PERIOD OF NOT LESS THAN ONE YEAR OF DATE OF ACCEPTANCE. 16.CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OF ANY OTHER PHASE OF INSTALLATION WHICH MAY HAVE BEEN I DAMAGED THER1 FY n 1-�. I i 16. ALL.REQUIRED INSURANCE SI{ALI.BE PROVIDED. EDGE OF e00YN r .4115'P�atiiA"1 i TO * PLENUN 17.ELECTRICAL INSTALLATION SHALL MEET ALL STANDARD REQUIREMENTS OF POWER AND - - --TELEPHONE COMPANIES. A.IRMAICL-UP I.INIT. � 18.THE E. CONTRACTOR SHALL.PAY FOR ALL PERMITS,FEES,INSPECTIONS,AND TESTING, \w" 3,.,4.,,11 19.ELECTRICAL CALCULATIONS WERE BASED ON INFORMATION PROVIDED BY OWNER, MECHANICAL CONTRACTOR Al-I'D ENGINEER.THE ELECTRICAL CONTRACTOR MUST VERIFY LOAD _ FOR EACH CIRCUIT AND ADJUST ACCORDINGLY. CHANGES TO BE REFLECTED IN AS BUILT DR,4 kVI*1GS,IF NECESSP A Y. 15A I -Ff-. plr tJ J yvl \ , � tj��11 0 M Ito 4 4r l EQ fTG1'i m 2 S DVS r Q� EXHAUST PLENUM t✓ELOW-/ e m,••m„ $ gt,oCK. •54 10" O.G. •-+ �4--- W E'LS TOP C'FIRE SUPPRESSION SYSTEM I ( , „ 12'..x: _ 3-1/2 - 1. THE FIRE SUPPRESSION SYSTEM IS INTERLOCKED WITH THE -(2'-e"): ' __ EXHAUST SYSTEM FOR FAN SIIUT-DOWN ON EMERGENCY - } I , EX t _ 1 FF. P!T! ( 15 ,P o f Z�'S y°o o o0 0 r DISCHARGE OF THE SYSTEM." 1 �: cEsS I 1 E S� 6 I N FaR � 2. THE SPRAY BOOTH IS EQUIPPED WITH AN AIR INTERLOCK _ - _ _ _ _ - _ __ _ � coNC. - SYSTEM THAT DOES NOT ALLOW AIR IN THC SPRAYING BOOTH IF I S�G�I D r,) ,� THE EXHAUST FAN IS NOT RUNNING 3. THE MANOMETER IS INSTALLED IN THE SPRAY BOOTH TO ILTERS AT ALL - MONITOR THE CONDITION OF THE EXHAUST IT of SPRAY eaoTa z� TIMES TIIE BOOTH IS RUNNING,AS PER CODES. E Y-1 S T1 N f, S C CAB-� SrAL C, ,,.I NOTES + + PRAY BOOTH COMPLIES ES 1. ALL EQUIPMENT FOR S - - - - -_ � _�� / ;�r �w ,.,,.•a.�,_,, ��, , , -WITH NEC 500 REQUIREMENTS FOR HAZARDOUS = ` �'" �"- N 1•�`'�~ ' nn'rc: j vE inn U'PE LOCATION S FLOPIDA.RrG. No. 36907 2. SWITCHES FOR LIGHTS ( IF USED ) AND EXHAUST + E 5 FEET MIN. FROM ANY BOOTH OPENING v e.oPe�a TAN ARE �'� 3. DISCON NECT SWITCH FOR EXHAUST FAN IS 3 FEET STAN ENGINEERING,wc. 6 q-5 S.W, q " �uAc�'`; AXIMUM FROM FAN Consulting Engineers SCALE: �S n1D 1 L°D APPROVED BY DRAWN BY J J-S �t M Mechanical & Electrical DATE: - - 0 �'}Q A►J v L.. 2 3• 9999 N.E. 2nd Ave./Suite 202 S P �� 6 OT *IA A VS i A I R-- �L�J',)V Y l Miami Shores, Florida 33138 AN O F�er'j'Ir.\f_A 1.r, ?;� "6)U I IZE Yl�'1 - PiT 5. b00-j'A Lk _U I-- �5-7 0 • Telephone (305) 759-1765 DRAWING NUMBER _ Fax (305) 759-5560 2 NATfCW PRINTFAST NO,IDBA•IOX24 - - - 1 i.