Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
01-0412-027
0 o ;T — - -- --- --- -- -' — ------- - - - — -- - =� SYMBOL LIST SYMBOL LIST SYMBOL DESCRIPTION MOUNTING SYMBOL DESCRIPTION MOUNTING ® a LIGHT FIXTURE, CEILING TYPE SEE FIXTURE Q 18" AFF OR AS LETTER INDICATES TYPE SCHEDULE TELEPHONE OUTLET NOTED �® LIGHT FIXTURE, WALL. BRACKET SEE FIXTURE 54" AFF OR AS LETTER INDICATES TYPE SCHEDULE © TELEPHONE OUTLET NOTED Y Y Y Y FLUORESCENT FIXTURE SEE FIXTURE 44" AFF OR RECESSED IN CEILING SCHEDULE TELEPHONE OUTLET r," ABOVE COUNTER A - FLOORESCENT FIXTURE SEE FIXTURE ~ t J ® Q TELEF$,HO E UTLET- 1`t•FLOO fB X p '` , r . SURFACE MOUNT TO CEILING SCHEDULE `� ? ,. ,w ,� 4 • �i I' t�?i SHADED FIXTURES ARE SEE FIXTURE COf"fPdTi DATA°QUTLET / IS" AFF OR v _ r �_ WIRED TO CRITICAL BRANCH SCHEDULE © COVER PLATE 'a AS NOTED STRIPED FIXTURES ARE SEE FIXTURE SOUND SYSTEM CEILING.* a `�`. GS'FI=USN,IN WIRED TO LIFE SAFETY BRANCH SCHEDULE MOUNTED SPEAKER GEI ,►ttG`.. .; ` Y Y :Y SEE FIXTURE SOUND SYSTEM VOLUME 48" AFF OR p FLUORESCENT STRIP FIXTURE e�J. i - ---- SCHEDULE VC CONTROL SWITCH AS NOTED ► p EXIT FIXTURE, SHADING INDICATES SEE FIXTURE SOUND SYSTEM MICROPHONE 18" AFF OR a SINGLE OR DOUBLE FACE SCHEDULE PAGING OUTLET AS NOTED r SEE FIXTURE SOUND SYSTEM WALL 116" AFF OR 2 D POLE WITH TOP FIXTURE SCHEDULE MOUNTED SPEAKER AS NOTED c/y N ---- ---- -- - -- POLE WITH ARM MOUNTED FIXTURE BOARD i` , A&-NC*TE17 - ' " SEE FIXTURE " RE TVTB GABLE tV TER1`1fNAL SCHEDULE � SEE FIXTURE TTB ��, T - - -- -- - �•. , �i EMERGENCY BATTERY UNIT SCHEDULE TELEPHONE TERMINAL BOARD AS NOTED - - -- - S - 48" A AS 18" AFF 2 SWITCH, SINGLE POLE LETTER AFF OR �-�j TELEVISION OUTLET OR Ir INDICATES LIGHTS CONTROLLED NOTED AS NOTED , y 48 AS CIRCUIT ELEV15ION f - ---- - S SWITCH TWO POLE AFF OR CLOSED C T AS NOTED z NOTED MONITOR r^ v r^ r" 48" AFF OR AS CLOSED CIRCUIT TELEVISION S SWITCH, THREE WAY � AS NOTED -- --------- ----- - 3 NOTED CAMERA .-'-- - --- __-. _ ._ - ._--- -'--- '--- _-. _-- --.--- - -_ 11 II - ---- ---- _ __:_ -- -- - -- -- - - -- -- - --- -- -- _ _._ _.._ _ __ - •; --- - ! _- --------- -- -- ----_- - .._ _:._- _ _-- - -_- -------- _, _ 48 AS MANUAL 48 AS SIUITCH FOUR WAY AFF OR FIRE ALARM MA AFF OR �{►� - NOTED PULL STATION NOTED 48" AFT= OR AS (C FIRE ALARM CHIME/FLASHING 80" AFF OR u DIMMER SWITCH NOTED LIGHT COMBINATION SIGNAL SEE NOTE BELOW S 48" AFF OR AS FIRE ALARM FLASHING 80" AFF OR ¢, 4 -- --- SWITCH WITH FAN RELAY :' `c� •. .•. , F NOTED LIGHT SIGNAL SEE NOTE BELOW ( •,� ------__ .-- __--- $ 48" AFF OR AS ON CEILING OR / .j SWITCH, KEY OPERATED © FIRE ALARM SMOKE DETECTOR NOTED AS NOTED • . °A TIME DELAY SWITCH 48" AFF OR AS o., WALL MOUNTED roll BELOW THE CEILING TO =° '• ° q' T NOTED SMOKE DETECTOR THE TOP OF THE DETECTOR a (n) 48" AFF OR AS ON CEILING OR R G iii) ++ i� SWITCH WITH PILOT LIGHT ® FIRE ALAR!"1 NEAT DETECTOR -- -_{° s -- - - - - -- -- - -,. - -- --- - NOTED AS NOTED ��� --.---- -- ------- �- SINGLE RECEPTACLE, 125V, 15A IS" AFF OR AS FAGP FIRE ALARM CONTROL PANEL b0" AFF TO TOP LICENSE M31S33 N NOTED OR AS NOTED t i N r-� - - IS AFF OR AS AA Coo AFF TO TOP MICHAEL P. SPYC ` t �� DUPLEX RECEPTACLE 125V 15A NOTED FIRE ALARM ANNUNCIATOR OR AS NOTED r'� --- - O AFF OR .DUPLEX RECEPTACLE, 125 V, 15A FLOW AND TAMPER SWITCH AS NOTED 6" ABOVE COUNTER TAGL 125 15A IS" A AS R REMOTE EST/ 48" A AS `� -- -- - - Lo - - - -- GROUND FAULT NOTED ` RESET SWITCH NOTED In cp DUPLEX RECEPTACLE, 125v, 15A 44" AFF OR AS (� DUCT TYPE SMOKE DETECTOR IN HVAC Z 2 Co - - . . - -- ------ - -- -D D E DE GF I of in �, N -\- _ GROUND FAULT NOTED T DUCTWORK M-1 x4 2 G = = G = �or DUPLEX RECEPTACLE, 125v, 15A 18" AFF OR AS IN HVAC .. ® SMOKE DAMPER V . W (ONE-HALF SWITCHED) NOTED DUGTWORG EXISTING RECEPTACLE AS NOTED ® RELAY AS NOTED ��� O Z 0 C DUPLEX RECEPTACLE, 125v, 15A CONDUIT AND ON FLOOR 12" AFF OR AS (PEDESTAL BOX) SERVICE FITTING © MAGNETIC DOOR HOLDER NOTED E>- DUPLEX RECEPTACLE, 125v, 15A FLUSH WITH FLOOR EXTERIOR F/A AUDIO SIGNAL 50" AFF OR A5 - - F FLUSH FLOOR BOX NOTED p� L F 15A 18 AS O ELECTRIC WATER GONG AS NOTED E �� m"� >` Y DUPLEX RECEPTACLE, 125V AFF OR GROUND TYPE NOTED . ISOLATED GRO EX RECEPTACLE, 125v, 15A 44" AFF OR AS 48" AFF OR AS ° •..'+ DUPL REG El PUSH BUTTON f ISOLATED GROUND TYPE NOTED NOTED RECEPTACLE, 10-125/250V, f8" AFF OR AS 48" AFF OR AS -' '_I1 -- r --- 20A, 2P3W NOTED KEYPAD NOTED --------- - - - 18" AFF OR AS " �; i QUADRAPLEX RECEPTACLE, 125v, I5A NOTED MAG-LOCK CONTACT AS NOTED i © 44" AFF OR ® WALL MOUNT 90" AFF ---------, - QUADRAPLEX RECEPTACLE, 125V, 15A NURSE CALL DOME L IGHT Q 3 (o ABOVE COUNTER OR AS NOTED ; �S \/ QUADRAPLEX RECEPTACLE, 125v, i5A CONDUIT AND ON FLOOR 48" AFF WITH CORD TO � \ ) -� (PEDESTAL BOX) SERVICE FITTING EMERGENCY NURSE CALL STATION� WITH PULL CORD REACH WITHIN 2" AFF l © �r t.NLE55 NOTED OTHERWISE .- ,n) � QUADRAPLEX RECEPTACLE, 125v, 15A F� USH WITH FLOOR LL ALL STATION - F (FLUSH FLOOR BOX) SINGLE BED NURSE C 4 ro AFF OR RECEPTACLE, 1m-125/250v, 18" AFF OR AS WITH ONE CORD SET AS NOTED BOA, 2P4W (DRYER) NOTED /� DOUBLE BED NURSE CALL STATION 4'-l0" AFF OR ® RECEPTACLE, 141-125/25OV, IS" AFF OR AS ``J� WITH DUAL CORD SET AS NOTED 50A, 2P4W (RANGE) NOTED NURSE CALL DUTY STATION 48" AFF OR 6" ABOVE ® ` O° SPECIAL RECEPTACLE AS COUNTERTOP NOTED 18" AFF OR AS NOTED NCA loo" AFF TO TOP OF w PANELBOARD 120/208v SEE PANEL C}--I NURSE CALL ANNUNCIATOR ANNUNCIATOR OR OR 1201240V SCHEDULE ABOVE COUNTERTOP SEE PANEL NGCP NURSE CALL CONTROL PANEL WALL MOUNTED © PANELBOARD 2111480V SCHEDULE 0 1 1 = OTESO 3 . DEVICE UNLESS NOTED OTHERWISE MOUNTING z TO THE CENTERLINE OF THE .MFG 0 DISCONNECT SWITCH TOP 60 AFF 40 SIZE/ FUSE/ OF POLES OR AS NOTED r 1. ALL EQUIPMENT INDICATED ON THIS PLAN IS EXISTING DISCONNECT SWITCH WITH TOP 60" AFF NOTE - THE DEVICE SHALL BE PLACED 80 INCHES ABOVE THE HIGHEST AND SHALL BE REMOVED UNLESS NOTED OTHERWISE. SEE MOTOR STARTER OR AS NOTED FLOOR LEVEL WITHIN THE SPACE OR 6 INCHES BELOW THE CEILING, PREVIOUS PLANS FOR ITEMS TO REMAIN. WHICHEVER IS LOWER � -•-~�c �� 2 ALL Fr- UNITS ABOVE THE CEILING5 SHALL REMAIN ® MOTOR STARTER AS NOTED ` ABBREVIATIONS UNLESS NOTED OTHERWISE. MOTOR STARTER SWITCH WITH AS NOTED AFC - AVAILABLE FAULT CURRENT 3" ALL SMOKE/FIRE DAMPERS SHALL REMAIN UNLESS NOTED OVERLOAD RELAYS AS REQUIRED AFF - ABOVE FINISHED FLOOR OTHERWISE. AHU - AIR HANDLING UNIT BFG - BELOW FINISHED GRADE 4" EXISTING ELECTRICAL PANEL A3 TO REMAIN. PROVIDE MOTOR AS NOTED C _ CONDUIT LOCKING FRONT COVER IF ONE DOES NOT EXIST. CW COOL WHITE LECTRIG DUCT HEATER AS NOTED DACT - DIGITAL ALARM COMMUNICATOR TRANSMITTER DACP - DOOR ALARM CONTROL PANEL OUTLET BOX WITH FLEXIBLE AS NOTED OR DN - DOWN CONDUIT CONNECTION TO EQUIPMENT REQUIRED EF - EXHAUST FAN m. EG - EQUIPMENT GROUND OUTLET, JUNCTION OR AS NOTED OR ENCL - ENCLOSURE 0 PULL BOX REQUIRED EWC - ELECTRIC WATER COOLER EWH - ELECTRIC WATER HEATER DRIVEN GROUND, UNLESS LUX - EXPLOSION PROOF I� PARTIAL THIRD FLOOR- NOTED OTHERWISE FHP - FRACTIONAL(HORSE POWER Q DEMOLITION PLAN CONDUIT CONGEALED IN CEILING NUMBER OF WIRES FLA - FULL LOAD AMPERES " - _ SPACE OR WALL INDICATED AS FOLLOWS G - GROUND SCALE 1/4" = 1'-0" CONDUIT IN FLOOR SLAB, CEILING TWO WIRES --i+— GFI - GROUND FAULT INTERRUPTER i' HID - HIGH NTENSISTY DISCHARGE U SLAB OR UNDERGROUND THREE WIRES --�I! HORIZ - HORIZONTAL HOME RUN TO PANEL (HASH MARKS IG - ISOLATED GROUND INDICATE NUMBER OF WIRES) FOUR WIRES ---�+t+- LW - LIGHT WHITE HP - HORSEPOWER, HEAT PUMP cc CONDUIT RUN EXPOSED HVAC - HEATING, VENTILATING, AIR CONDITIONfNG JB - JUNCTION BOX O Z LRA - LOCKED ROTOR AMPERES O co MCB - MAIN CIRCUIT BREAKER -j LOW VOLTAGE WIRING MLO - MAIN LUGS ONLY LL J- NEUTRAL ISOLATED NEUTRAL AND SEPERATE GROUNOM, CONDUCTORS NL - NIGHT LIGHT ® 0 NOT SHOWN EXCEPT OB - OUTLET BOX GROUND CONDUCTORS (CLEAN CIRCUIT) L� FOR CLEAN CIRCUITS PB - PULL BOX, PUSHBUTTON O PS - PAY STATION o CONDUIT RUN UP AS SHOWN RECEPT - RECEPTACLE SF - SUPPLY FAN SPEC - SPECIFICATIONS O CD c CONDUIT RUN DOWN AS SHOWN SWECS - SMOKE WARNING EMERGENCY:CALL SYSTEM TL - TWISTLOCK TTB - TELEPHONE TERMINAL BOARD W .� O 3O 3❑ O REFER TO LIKE NUMBERED NOTES TvTB - TELEV161ON TERMINAL BOARD VERT - VERTICAL G= WM - WATT MISER WP - WEATHERPROOF WW - WARM WHITE XFMR - TRANSFORMER O °o. !I? CV .Z c 0 0Q w - Uo°ODotr E ..o