01-0412-022 a � � 0 e @ ll � G� I LOAD CODE KVA WIRE BRKR ABC MKR WIRE KVA CODE LOAD / PANEL: A3 (EXISTING) 00 1 Rd. 305, 306 L 1.06 12 20 A 20 12 1.08 R RM, 302, 303 2 VOLTAGE: 120 208V,3P,4W �- 3 R11. 364, 305 R 1.08 12 10 8 ZO 12 1.00 l RM. 301, 303 4 W+NJFACTUFf: SQUARE D CUPANY ---- ------- ----------------------------- -- --------------- ------ - ------ --------- --------------- -------- ----------- ------ ------------- ----- --- -- ----- - ------- ------------ o 5 131. 304, 305 l 1.01 12 20 C 20 11 0.90 R Rd. 301, 302 6 TYPE: 0 _ 7 131. 301 R 0.74 12 20 A 20 11 0.94 L TOILET LTS k RECEPT 8 VAIN ALPS: 200 A1.A 9 RM, 310,311, 312 L 0.78 12 20 6 20 11 1.00 R RV. 309, 310 10 MLO OR McB: MLO AIC RATING: 10,000 M 11 IN. 310,311, 312 R 1.08 12 20 C 20 12 1.08 R RV. 308, 309 12 MRS 13 131. 311, 312 L 0.84 12 20 A 20 12 1`50.1 HALL LIGHTS 14 MOl!<NT I� FLUSH _. _ o`er c4 LOCATION: CORRIDOR 15 fad. 311, 312 R 1:03 12 20 8 20 12 0.90 R- Rd. 325, 328 16 THIRD FLOOR FEED: BOTTOM 93 tj 17 RI. 325, 328 L 0.56 12 20 C 20 12 1.08 R RM. 325, 327, 328 18 CU OR AL WIRE: CU - - - ` 9 FEEDER: 200 ALP - ®® 19 A/C RM. RECEPT. R 0.72 12 20 A 20 11 0.90 H RM. 301, 304 FAN 20 SEE RISER DIAGRAM p eg FOR &21 A/C Rd. LIGHTS l 0.36 12 20 B 20 12 0.90 R R1. 326, 327 22 SIZES WIRE IT A P 23 Rd. 326, 327 R 0.72 12 20 C 20 12 1.08 R RI. 326, 327 24 25 RM. 309, 312 FAN H 0.90 12 10 A 20 12 0.60 H FAN COIL UNIT 26 NOTES: NORMk BRANCH 3 3P -10 2.00 H 28 + NEW CIRCUIT MEYER ��f 29 + N'E�M EDH E 1.15 10 25 C 10 2.00 H STRIP HEATER 30 SPACE I A 10 2.00 H 31 51� \ 33 EX R 0.72 12 20 B 1 SPACE 34 ® Q 35 EWC R 0.72 12 20 C 20 12 0.60 H FAN COIL UNIT 36 - \ 37 RECEPT. R 0.72 12 20 A 3P 1 11.39 S 38 ------ --- -- -- -- ----- ---- ------- -- --.------ -------------- ------ ---- ------- - - --- ----- ----- -- - ----- --- ------ - -- ------ -- -------- ------ _. 39 RECEPT. R 0.72 12 20 8 1 11.39 S PANEL -A4 40 41 SPACE I C 125 1 11.39 S ON FOURTH FLOOR 42 TOTAL KVA CR1"IECTED 23.39 BUS A 22.53 BUS B 23:36 BUS C TOTAL 69.28 KVA LIGHTING: 8.04 KVA X 1.25 DEMAND FACTOR 10.05 DEMAND LOAD PANEL CALCULATION RECEPTACLES: 10.00 KVA X 1.00 DEMAND FACTOR 10.00 DE]M LOAD 67.83 RECEPTACLES: 6.92 RVA X 0.50 DEMAND FACTOR, 3.46 DEMIAD LOAD TINS 1000 HNAC: 9.00 KVA X 1.00 DEMAND FACTOR 9.00 DEMAND LOAD DIVIDED BY 1.73 ALPS EQUIP►1ENT: 1.15 KVA X 1.00 DEMAND FACTOR 1.15 DEMAND LOAD DIVIDED SY 208 188.28 KITCHEN EQUIPMENT: 0.00 KVA X 0.00 DEMAND FACTOR 0.00 DEWZ LOAD SWEED 34.17 KVA X 1.00 DEMAND FACTOR 34.17 DEM..`D LOAD LARGEST MOTOR: 0.00 KVA X 0.25 DEMAND FACTOR 0.00 DEYAN'0 LOAD I LOAD CODE KYA WIRE MKR ABC BPKR WIRE KVA CODE LOAD I PANEL: DPC (EXISTING) 1 LOAD CODE KYA WIRE �tKR ABC BRIOt HIRE KVA CODE LOAD I PANEL: EC3 (EXISTING) �� + �;�ILI 1 NURSE STATION L 0.60 12 20 A 10 12 0.72 L Rd. 301 -303 2 VOLTAGE: 120/208V,3P,4W o %.•'� I H 0.90 12 V A 3P 10 2.00 H 2 VOLTAGE; 120/208V.3P,4W c s 3 AMH 10 H 0.90 12 B 10 2.00 H At#1 4 4 Vd IJFACTUPE: SQUARE D CCAPANY 3 IfDIC LAB R 0.70 11 20 B 20 12 0.72 R RM. 304 -306 4 RMACTURE: SO.IAP.EE D OVANY S H 0.90 12 20 C 30 10 1.00 H 6 TYPE: NQ08 5 E 8 S HALL RECEPT. R 0.11 12 20 C 20 12 0.72 L FM. 359, 361 6 TYPE: NOO 1 E 1.40 3 3P A 3P 10 1.35E 8 MAIN MPS: 250 AMP 7 NURSE STATION REC. R 0.54 12 20 A 20 11 0.72 R RM. 310-332 8 MAIN AMPS: 60 AMP ►1MA OR MOB: 250 MILO OR MCB: WO L DENSE 031533 9 CRASH CART REC. R 0.36 12 20 B I SPARE 10 9 COLPRESSOR E 7.40 3 B 10 1.36 E COLFRESSOR 10 AIC RATING: 10,000 ALPS ���-- -- �K 1'IC;44EL P. 5F"'GHALA AIC RATING: 22,000 ALPS 11 DARK RM. LIGHTS L 0.40 12 20 C 20 12 0.20 E NURSE CALL SYSTEM 12 11 E 7.40 3 100 C 30 10 1.36 E 12 MOUNTING: FLUSH 13 Hf 4.00 6 3P A Y 3 5.00 H 14 MOUNTING: SURFACE 13 SPARE 1 20 A I SPARE 14 LOCATION: FIRST FLOOR, 15 SPARE 1 20 B 20 12 0.72 R RM. 308, 309, 340 16 LOCATION: THIRD CORRIDOR FLOOR 15 EH-1,2,3, k 4 H 4.00 6 B 3 5.00 H EH-8 16 ELECTRICAL Rd 12 FEED: BOTTOM v FEED: BOTTOM 17 s RECEPTACLES R 0.70 12 20 C 20 1 SPARE 13 CU OR AL WIRE: CU .� co Ns 17 H 4.00 6 60 C 100 3 5.00 H 18 CU OR Al WIPE: CU FEEDER: 60 AMP FEEDER: 250 AMP 19'9 RECEPTACLES R 0.36 12 20 A 20 12 0.20 E NCCP + 20 SEE RISERDIAMM 1� 19 H 1.33 12 Y A 20 12 5.20 H 3RD Fl PSYCH WING 20 SEE RISER DIAGRAM FOR WIRE k CONDUIT -U c' FOR WIRE R CONDUIT 21 + RECEPTACLES R 0.90 _12 20 B 20 12 0.20 E MAC-LOCK s 22 SIZES REQUIRED - co 21 EH-5 H 1.33 12 6 I SPACE 22 S I ZES REOU I RED �j Z co 23 H 1.33 11 20 C I SPACE 24 23 + RECEPTACLES R 0.90 12 20 C 20 12 0.50 L L IGHTS + 24 HI d 25 NOT AVAILABLE I A I NOT AVAILABLE 26 NOTES: CRITICAL BRANC}i •. M 25 SPACE I A I SPACE 25 NOTES: EOUIP'.M BUD V � 27 SPACE I B I SPACE 28 + -NEW CIRCUIT 27 NOT AVAILABLE I B I NOT AVAILABLE 28 + -BREAKERS ARE 6,582 AFC 9,130 AFG 2,481 AFC 9,130 AFC b o EXISTING. CIRCUITS BREAKER SHALL MEET I---, i --, I --, I --� ^ 0 � '�a 29 NOT AVAILABLE I C I NOT AVAILABLE 30 ARE 0. 29 SPACE I C I SPACE 30 OR EXCEED MINIMUd I C3 I I B3 1 I EC3 I I A3 I M•�1 Z c o AIC VALUE BASED ON 31 NOT AVAILABLE I A I NOT AVAILABLE 32 1 1504 1 120041 1 60A I 120041 31•SPACE I A I SPACE 32 AFC INDICATED ON I 1 I 1 SHEET E1.0. 33 NOT AVAILABLE 1 6 1 NOT AVAILABLE 34 1_ 33 SPACE I B I SPACE 34 35 NOT AVAILABLE I C I NOT AVAILABLE 36 I I I I F•+y '°co 35 SPACE I C I SPACE 36 I I I I Z o 37 SPACE I A I SPACE 38 31 NOT AVAILABLE I A 1 NOT AVAILABLE 38 EXISTING RUN OF--� EXISTING RUN OF- 39 NOT AVAILABLE I B I NOT AVAILABLE 40 I EXISTING R1U) CU. AHU-I p ,f-� I 1 O 39 SPACE I B I SPACE 40 I r I I I 1 4-'1/0 THW CU. I 4-0I/0 THW GU. : I 4-01/0 THW CU. : NEW � fl� 41 SPACE I C I SPACE 42 IN 2 C_ 1 IN 2 I I IN 2 G. i s rs 11 NOT AVAILABLE I C I NOT AVAILABLE 42 I I I I �� 1 E co TOTAL KYA MECTED 3.14 BUS A 3.60 BUS B 4.14 BUS C TOTAL 10.83 KYA I I I I TOTAL KVA COtNECTED 27.19 BUS A 21.99 BUS B 21.99 BUS C TOTAL 71.17 KVA LIGHTING: 2.94 KVA X 1.25 DEW FACTOR 3.68 DEMAND LOAD PANEL CALCULATION In LIGHTING: 0.00 KYA X 1.25 DEMAND FACTOR 0.00 DEMAND LOAD PANEL CALCULATION I � I I I �°-..' � '�f •o x RECEPTACLES: 0.00 KVA X 1.00 DD' D FACTOR 0.00 DIM LOAD , RECEPTACLES: 1.34 KVA X 1.00 DEMAND FACTOR 1.34 DEMAND LOAD � 11.61 _� � �M a. 11.17 RECEPTACLES: 0.00 KVA X 0.50 DEMAND FACTOR 0.00 DEMAND LOAD TIMES 1000 I I I I RECEPTACLES: 0.00 KVA X 0.50 DERNM FACTOR 0.00 DEMO LOAD TIMES 1000 HVAC: 0.00 KYA X 1.00 DEMLID FACTOR 0.00 DEMAD LOAD DIVIDED BY 1.73 Afi 1 HTVAC: 44.89 KVA X 1.00 DEltARO FACTOR 44.89 DEMO LOAD DIVIDED BY 1.73 AMPS EQUIPMENT: 0.60 KVA X 1.00 DEM,"•1D FACTOR 0.60 DEMAND LOAD DIVIDED BY 208 32.24 I EOHIPLENT: 26.28 KYA X 1.00 DEMAND FACTOR 25.28 DEIL%T LOAD DIVIDED BY 208 197.55 KITCHEN EQUIPMENT: 0.00 KVA X 0.DO DEV=FACTOR 0.00 D "ND LOAD I KITCHEN EQUIPMENT: O.CO KVA X 0.00 DEV-"O FACTOR 0.00 DEWM LOAD SLEFEED 0.00 KVA X 1.00 DEl6:D FACTOR 0.00 CE *Zn LOAD TO PANEL-DPl TO PANEL-B2 I TO PANEL-A2 NEW ", OF SU�EED 0.00 KVA X 1.00 DR'LtO FACTOR 0.00 DELI"'D LOAD LARGEST MWTCR: O.CO KYA X 0.25 DE00 FACTOR 0.00 DEMAND UVO GROUND FLOOR I r LARGEST MOTOR: 0.00 KVA X 0.25 DEIL,M) FACTOR 0.00 DEW10 LOUD ELECTRICAL ROOM. SECOND FLOOR 1 SECOND FLOOR 3- 12 TH+W GU. 1 IN 3/4 G. � J Q I 0 I -_1 I ® LL I I LOAD CODE KVA WIRE ET<1(R ABC ERKR WIRE KVA CODE LOAD I PANEL: LS (EXISTING) NOTES O I 1 N. STAIRS LIGHTS l 1.20 12 20 A 20 10 1.00 L 5TH FL. HAIL LIGHTS 2 VOLTAGE: 120/268V,3P,4W I e�O 3 N. STAIRS k EX. LICL 0.36 12 20 B 20 10 0.73 L 5TH FL. HALL LIGHTS 4 kVNUF9TURE: SQUARE 0 COMPANY 1. ALL EQUIPMENT INDICATED ON THIS RISER DIAGRAM IS EXISTING 1 0 UNLESS NOTED OTHERWISE. 1 5 S. STAIRS k EX. LIGL 1.48 12 20 C 20 10 1.20 l 21D FL. HAIL LIGHTS 6 TYPE: N00 I I 7 E. STAIRS k EX. LIGL 0.84 12 20 A 20 10 0.48 L 2ND FL. HALL LIGHTS 8 PAIN AMPS: 60 A1dP 2. THE SCOPE OF THI5 PROJECT SHALL INCLUDE ADDING NINE (9) 1 ►10 OR UC8: W-0 BRANCH CIRCUITS TO THE NOTED PANELS AND RE-USING THE ' 9 1ST Fl. HALL LIGMSL 1.00 12 20 B 20 to 1.16 L 3RD FL. PALL ucxTSlo EXISTING CIRCUITRY FROM WITHIN THE BOUNDARY OF THI5 AIC RATING: 10,000 AIFS I 11 1ST FL. EX, LIGHTS L 1.26 12 20 C 20 10 0.36 L 3RD FL. HALL LIGHTS12 PROJECT. I MOUNNTING: (LUSH I 13 SPARE 1 20 A 20 10 1.10 L 4TH FL. WALL LIWS14 3. NEW MECHANICAL EQUIPMENT. ROUTE FEEDER WIRE IN CONDUIT LOCATION: FIRST FLOOR THROUGH NEAREST CHASE DOWN BUILDING TO FIRST FLOOR ELECT. ----- - - -- --- -- - - - ----- ---- - - 15 SPARE 1 20 B 20 10 0.36 L 4TH FL. HALL L I GHTS16 ELECTRICAL FOCM -- - -- - - - - - -- --- -- - - -- --- -- - - - - ------ -- --- - - - - - ---- - --- - ----- -- -1 -- -- -- ---- - ---- --- - --- FEED: BOTTCld ROOM AS INDICATED. 17 1ST FL. DOOR HOLD E 0.20 12 20 C 20 10 0.20 E 2ND FL. DOCK HOLD 18 CU OR AL WIRE: CU I FEEDER: 60 AP 4" PROVIDE AIR TERMINAL AND DOWNLEAD CABLE AS REQUIRED FOR 1 19 PBX EQUIP. E 0.60 12 20 A 20 10 0.20 E 3PD FL. DOCK HOLD 20 SEE RISER DIAGRAM --- - W - i FOR WIRE k CONDUIT ROOF MOUNTED EQUIPMENT. INSTALL AND TIE INTO EXISTING EXISTING RUN OF -� EXISTING RUN OF i 1 TO EXISTING AT5-4 c 12 014 AFC 1 4p�20 AFC EXISTING RUN OF-� 33 545 AFC, o 33,366 AFC 18,935 A'rC 21 OR. ENTRY LIGHTS l 0.50 12 20 B 20 10 0.20 E 4TH FL. DOOR. 22 SIZES RECUIPFD LIGHTNING PROTECTION SYSTEM AS R_Qt11RED. 4 '6-THW CU. _ _ _.I_, 4-'6 THW CU. r_ _ 4- 250 MCM GU. _ _ 1_L , (FIRE PUMP) 23 LOBBY LIGHTS L 0.20 12 20 C 20 10 0.20 E 571T FL. DOOR HOLD 24 i--------------I IN 1" C. I DP3, i L5 I IN 1" C. 1 DP4 i IN 2.5 C. t DP2 I I DPC I TO EXISTING ATS-3 I 1 100A I 160A I 1500,41 1600,41 1250A 1 25 NOT AVAILABLE I A I NOT AVAILABLE 26 NOTES: LIFE SAFETY BRANCH I I I I I I I I I I I I TO EXISTING ATS-2 27 NOT AVAILABLE I B I NOT AVAILABLE 28 1 I 1 I I I I I TO EXISTING AT5-1 I I 29 NOT AVAILABLE I C I NOT AVAILABLE 30 31 NOT AVAILABLE I A I NOT AVAILABLE 32 EXISTING RUN CF� EXISTING 2 RUNS OF I EX15TING 2 MGM GU. I 4-�'3 THW GU. 4-"250 MCM CU. 33 NOT AVAILABLE 1 B 1 NOT AVAILABLE 34 - _--__ ___-- �_ --__-_--_ I I I I F.P. t L. CO. I IN 125" C. I\ �___ IN 25" C. '\ TO PNL-GE 1N 2-5 C. TO PNL-GE 1 TO PNL-GE I TRANSFORMtR i � I -� i i--- � i \ I -� 4-----� I : : 33,501 AFC , . 38,671 4FG i---� � : i 12004 1 EXISTING 35 NOT AVAILABLE I C I NOT AVAILABLE 36 i VAULT I I \ I I I_I_I- 37 NOT AVAILABLE I A I NOT AVAILABLE 38 I MAXIMUM I I DP-5 I LIFE SAFETY I I CRITICAL I I EQUIPMENT I I i EMERG. _. AVAILABLE. I 18004 : BRANCH I BRANCH I BRAND= I 39 NOT AVAILABLE 1 8 1 NOT AVAILABLE 40 LOAD CALCULATION I I SW. *2 I 1_ 1_ 1_ I I GEN. DIST. AIC RMS 1 NORMAL I r-- I r-- 1 I r-- 1 I : I PANEL-GE 41 NOT AVAILABLE I C I NOT AVAILABLE 42 i 49333 AMPS BRANCH -1-r- 100 1 i t 1 I I 600, I I I 1 I 1 I AT5-2 I 3 i I ATS-3 I I I : AT5-I TOTAL KVA COIlfCTED 5.42 BUS A 4.30 BUS 8 5.10 BUS C TOTAL 14.82 KVA LOAD CALCULATION FOR EXISTING GENERATOR I I 1 1 100 3 i 1200A r----- 500 I ---160004 r----- I r---16004 r---- I L 77- -- 1 1 19,451 AFC L-T-I- I 1 39,159 AFC `T T- I 1 31,800 AFC �YISTING : EX15TING L ICHTI NC: 13.22 KVA z 1.25 DEMAND FACTOR 15.53 DEMAND LOAD PANEL CALCULATION I L---- L---- L---- 3 RUNS OF d-600 MCM CU. NEW LOAD ADDED 18.00 KVA I I I I I I I I I I 30OKLU - 315KVA "1 RECEPTACLES: 0.00 KVA X 1.00 DEMAD FACTOR 0.00 DEMAND LOAD 18.13 EXISTING ATS-1 CRITICAL BRANCH 163.10 KVA I I I 1 : I I 600 : 1 IN 35 C. RECEPTACLES: 0.00 KVA X 0.50 DEMAND FACTOR 0.00 DEMAD LOAD TIES 1000 EMER MAIN 3 MAIN - --- - --3 PH, 4W, 1201208v- th'AC: 0.00 KVA X 1.00 DEMAND FACTOR 0.00 DEMAND LOAD DIVIDED BY 1.73 AIDS EXISTING ATS-2 LIFE SAFETY BRANCH 28.24 KVA I I ' ' 1 1 1 I bmm I a - I 1 I I I I MAIN SW. .i I SW. "3 I I SUU. Y6 GENERATOR EQUIPMENT: 1.60 KYA X 1:00 DEMAND FACTOR 1.60 DEMAND LOAD DIVIDED BY 208 50.31 - EXISTING ATS-3 EQUIPMENT BRANCH 134.89 KVA Y KITCIEN EQUIPMENT: 0.00 KYA X 0.00 DEMAND FACTOR 0.00 DEl4W) LOAD ------------------- - __ __---- ----- ---N-1--------------------- t-t- --- ----._ .__. _ _ -- -- --- --------------t-t----- -------- ------- -------------t--t- --------- � SUBFEED o.0o KYA z 1.06 DE1U D FACTOR o.00 DEIWD LOAD EXISTING ATS-4 EQUIPMENT BRANCH 52.30 KVA TO >T MR VAULT I , TO XFMR VAULT I i TO XFMR VAULT I I TO XFMR VAULT I I I 30,111 AFC -•-------- ---- -- - ---- - LARGEST MOTOR: 0.00 KVA X 0.25 DEMAID FACTOR 0.00 DEVI)LOAD EXISTING FIRE PIMP (LARGEST MOTOR 52.30 X DEMAND LOAD OF 25% PER N 13.08 KVA ' I I i I i I I i --- -------------------------- -- ------------------------- 1 - SUB TOTAL A 409.67 KVA � � � -� 1 I EXISTING 2 RUNS OF 1 EXISTING 2 RUNS OF ' i I EXI5TING RUN OF I 1 4-•350 MCM CU. ' EX15TING 4-•250 MGM CU. I 0350 MCM CU GRD" LESS ONE ELEVATOR (ONLY ONE ELEVATOR WORKS EXISTING BUILDING -� 4-"3 THW GU. i IN 25" C. i IN 25" C. I WHEN GENERATOR IS N) 41.20 KVA SYSTEM GROUND - i IN 125 G. -I - 1 - _ 1 -I 0 - SUB TOTAL B 368.47 KVA X 1000 � e t DIVIDED BY 1.73 s - DIVIDED BY 208.00 1022.79 AMPS REQUIRED 1041 STAND BY MAPS AVAILABLE FROM AN EXISTING 30OKW / 375KVA GENERATOR Lu THE HIGHEST PEAK DEMAND FOR SERVICE TO THE HOSPITAL T A WITHIN THE LAST CALENDER YEAR WAS 600 KVA PARTIAL IAL RISER DIAGRAM cc N - O �O F m m c:) - t� 4.< 0 `° Q0W _ N Uo � 00 E1,0.