01-0386-019 DATE REVISIONS W. FAN SCHE DUl_E HOOD &CHE IDUL_ E MANUFACTURER ELECT. SERVICE DIMENSIONS WEIGHT MANUFACTURER FAN AND MODEL NO, RPM HP CFM S" S.P. VOLTS/PH/Hz WxLxH (IN.) LBS. REMARKS LENGTH W H(IN) XAHUST/COLLAR SUPPLY/COLLAR REMARKS EXIST. BROAN 696 AND MODEL NO. - EF 01,2 43 1500 1/80 10061/8" 115/1/60 10x10x6 10 /GRILLE , 4"� S/M DUCT, DAMPER SAV ON AIR SU1E UL LISTED STANLESS STEEL HOOD EXIS i. 4 ROOF CAP KIT HOO 108" 46" 24" 2340 CFM /12"X16" 1800 CFM,/ 38"XS" UJ/ANSUL F.P. SYSTEM,LIGHT 4 FILTER ' GREENHECK CUBE 161 W/VENTED 4 HINGED ROOF CURB, EF 04 1200 3/4 234063/4" 208-230/1/60 29DIAX25H 21 5IRD5CREEN. MOTOR 5TARTER4DISC, LMDG - QD UL162 LISTED • BF 05 GREENHECK RSF 100 LMDX 780 3/4 180063/8" " 41X4IX25 ___ UJ/ROOF CURB, DUCT ADAPTOR M, STARTER 4 DISCON. HOOD NOTES: I. INSTALLATION SHALL COMPLY W-NFPA S6/LOCAL CODES. 2, 1400D SHALL BE 18 GAGE STAINLESS STEEL (TYPE 304). ALL SEAMS AND JOINTS SHALL BE LIQUID TIGHT CONTINUOUS EXTERNAL WELD. 3. A. EXHAUST DUCTWORK SHALL BE 16C CARBON STEEL ALL WELDED CONSTRUCTION. B. SUPPLY DUCTWORK SHALL BE 22C GALVANIZED STEEL. 4. HOOD SHALL HAVE: A WET CHEMICAL FIRE PROTECTION SYSTEM NOZZLES EXPLOSION PROOF LIGHT, STEEL MESH GREASE FILTERS, GREASE DRIP TRAY DRAINING TO 22 GAGE STAINLESS STEEL GREASE RECEPTACLE. 10' MIN. EXH. HOOD FAN EXHAUST FAN NOTE: FILTERED SUPPLY FAN 16 GAUGE WELDED STEEL FAN 814ALL BE MOUNTED ON NON-COMBUSTIBLE ROOF CURB ACCORDING TO NFPA-96. DISCHARGE GREASE EXH. DUCT OF FAN SHALL BE 40" MIN. FROM ROOF SURFACE AND 10' MIN. HORIZONTALLY FROM ANY FRESH AIR 16 GAUGE WELDED STEEL INTAKE OR THE SUPPLY FAN. FIRE MODE REQUIRES EXHAUST FAN t0 BE ON WHENEVER THE 12" CURB GREASE EXH. DUCT METAL STUDS EXTINGUISHING SYSTEM IS ACTIVATED. MIN.(TYP) STEEL 42" MIN PREF. ROOF CURB MANUF. 5/8" GYPSUM BOARD TYPE X ROOF JOIST 7 BY GREENHECK n VENTED [21 GAUGE GALV. OR STAINLESS STEEL PLATE SUPPLY FAN NOTE: METAL STUDS FAN SHALL BE MOUNTED ON ROOF CURB 10" MIN. FROM EXHAUST FAN OR PLUMBING VENT. S. FAN n/ "n/ SHALL BE ELECTRICALLY INTERLOCKED WITH EXHAUST FAN AND WITH HOOD FIRE SUPPRESSION SYSTEM 5/8" GYPSUM BOARD TYPE X TO BE "OFF" IN CASE OF FIRE, n n n n 6.. 22 GAUGE GALV. OR STAINLESS STEEL PLATE Hnd n F.D. n 6" AIR SPACE Ell KITCHEN VENTILATION NOTES: I. THE KITCHEN VENTILATION SYSTEM HAS BEEN DESIGNED WITH THE INTENT TO MANTAIN A CEILING TILE o n NEGATIVE PRESSURE, NEVER OVER .02" W.C. RELATIVE TO ALL INDOOR SPACES SURROUNDING THE KITCHEN SPACE, DURING COOKING HOURS, COMPLYING WITH "THE FLORIDA ENERGY lo 24, n ANSUL SYSTEM FZPKNOZZLE EFFICIENCY CODE" SECTION 303.1 (A). lz�_UL. APPROVED INCAND. VAPOR n WASHABLE REMOVABLE 2. ALL EXHAUST AND MAKE UP AIR SYSTEM COMPONENTS (FANS, DAMPERS, ETC-) SHALL BE PROOF LIGHH 45' n NON-COMBUSTIBLE ALUMINIUM INTERLOCKED IN SUCH A WAY THAT THE BALANCE PRESCRIBED IN (1) ABOVE IS MAINTAINED FILTERS (UL. APPROVED) THROUGHOUT ALL COOKING HOURS, AND ALL VARIATIONS OF COOKING OPERATIONS. PROVIDE PILOT LIGHT IN KITCHEN AREA INTERLOCKED TO SUPPLY 4 EXHAUST FANS. Tr REMOVABLE GREASE RECEPT. 1 HR FIRE RATED ENCLOSURE ADJUSTABLE VANE 2�� n LESS THAN I GAL. CAPACITY NTS / a. SUPPLY AND EXHAUST FANS ARE INTERLOCKED WITH PILOT LIGHT IN KITCHEN AREA, SUPPLY AIR DIFF, no / b. FIRE MODE REQUIRES EXHAUST FAN CONTINUES TO OPERATE AND SUPPLY FAN STOPS. /c. HOOD EXHAUST FANS SHALL OPERATE WHENEVER THE EXTINGUISHING SYSTEM IS ACTIVATED. 41-C 11 n TENANT PREPARATION J d. FIXED PIPE EXTINGUISHING SYSTEMS IN A SINGLE HAZARD AREA SHALL BE ARRANGED FOR ol n PROTECTION OVERLAP SIMULTANEOUS AUTOMATIC OPERATION UPON ACTIVATION OF ANYONE OF THE SYSTEMS. THE HOOD WITH THE 6" n PROTECTION BY 18" EACH SIDE ALL THE '-0 AX. n 6 WAY DOWN " BELOW 6" n COOKING SURFACE i (ALL AROUND) n PARTITION " PULLEY ELBOW-TYPICAL 1/2" DIAMETER DETECTION CABLE CONDUIT SERIES DETECTOR W/ 360 DEC. F FUSIBLE LINK DUCT NOZZLE SP-2 3/8" DIAMETER KITCHEN HOOD I / AGENT PIPING SYSTEM DETAIL, t0 MECHANICAL ._ N.T.S. GAS VALVE i I APPLIANCE NOZZLE SW TERMIMINAL DETECTOR I W/ 360 DEC. F Drawings and Specifications as instrument of service are and shall remain the FUSIBLE LINK property of the Architect and shall remain the property of the Architect wheth the project for which they were made is executed or not.They are not to be ue in any manner on other projects or extensions to this project except by agrees in writing and with the appropriate compensation to the Amhitec t.Reproducti U REMOTE of drawings and ifica6ons without the written consent of the Architect is PULL STATION I � � I prolubited. u EXPELLAN 2 -011 / PIPING CAPTURE HOOD 101 PLENUM NOZZLE AREA, OVER ITEM 0 O FLYER 3/8" APPLIANCE.NOZZLE 5W _ .'®• 9'-0" CAPTURE AREA. '��+� 3 GALLON ASNSULEX TANK W/WALL BRACKET i JOHN R MEDINA&ASSOCIATES,Architects, PLENUM NOZZLE i ofce(305)740 05554 %F5)7405355 I OVER ITEM O �— 22 GAUGE GALV. OR STAINLESS 0 f�ANGEfz,It FLORIDACERTRrICAT ION NUMBER.RA14867 MIN. STEEL PLATE CERTIFICATE OF CORPORATE AUTHORIZATION AA00026' " BREAD GALLERY REMODELATION. ' li PLENUM NOZZLE " 31" MAX, 17" MIN E, " 70 COOKING SURFACE. 5784 SUNSET DRIVE „ ,MECHANICAL AUTOMAN SOUTH MIAMI FLORIDA 6 MIN. REMOTE PULL STATION W/ LT-30-R CARTRIDGE OVER ITEM 02 y 60" AFF.(MAXIMUM) CHARBROILER CONTACT:CESAR&LUISA RINCON`'(305)663-1179 COOKING EQUIP. JOB /: XXXXX ' REFER t0 M-1 SHEET FOR MOUNTING ANSUL R-102 HOOD FIRE SUPPRESION GUERRERO/GONZALE2 LOCATION OF ANSULEX TANK AUTOMAN AND REMOTE PULL STATION. 5Y5TEM PIPING ISOMETRIC ENGINEERS, INC. NTS Michael C. Guerrero, P.E. Mechonkal Eng. tk. 115235 Rafael L Conza4z, RE Electrleal Enq. Lk. /11057 4300 S.W. 73rd Avenue, Suite f 107 Miami, Florida 33155 Td. (305) 262-3941, Fax (305) 262-8211 E—mail: GGENGQACCESSPRO."ET HOOD ELEVATION --- NTS GUERfj .�\eA i F s,z° FLOOR PLAN l V:•�, ����` �, w SCALE: AS SHOWN DATE: FEB.'01 M 2 DRAWN: DHB