Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
01-0386-018
DATE REVISIONS BY HVAC DESIGN REQUIRES: YES NO AIR CONDITIONING 5C�IEDULE OUTSIDE AIR CALCULATION % DUCT DESIGN EQJI DETECTOR x � PER ASHRAE 62 - 89 �/ UNIT MANUFACTURER NOM. NOM, ESP IN. ELECT. TOTAL COOLING CAP.8/t O/A DIMENSIONS WEIGHT ELEGt.SERVICE DER T=IRE DAMPER l8) AND MODEL NO. TONS CFM U a. HEAT KW LA/HP BTUH a 95. 4 61' W UxLxH (IN.) LBS. ELECT.smv CUSTOMER DINING AREA O/A REQUIRED 20 CFM/PER x A/C BART ---- 500 _ 40 PEIR60N MAX. SMOKE DAMPER(S) x RTLIOf (EXIST) 9 2000 --- --- •-• 208- 1 60 - 230 / KITCHEN AREA O/A REQ'D - IS CFM/PER FIRE RATED ENCLOSURE 20 MR/1000 SQ.FT,AREA . 448 SGIFt x A/C CARRIER 50SX060 - 3 5 2000 b 10 41,4/1 46,000/60,000 500 46x40x38 319 208 (I / bm 113 FIRE RATED ROOF/FLOOR x RTU CFM ■ 40 x 20 +20 X�$x 15 • S34 CEILING:A85EMBLY NOTES% v= DIRE STOPPINGa x PROVIDED 1000 CPM SMOKE CONTROIL x 900 CFM THRJ A/C h 4 900 CFM THRU A/C e2 FROM DETECTOR AIR CONDITIONING SYSTEM - GENERAL NOTES' (IF A LI ABLE) IONIZATION SMOKE DETECTOR 5 ING DRYWALL CEILING. HVAC LEGEND (SEE HVAC PLANS) I I I/2• I. DUCTWORK SHALL BE 1 1/I" THICK,3 POUNDS PER CU®IC FOOT DENSITY DETECTOR TEST PANEL FIBERGLASS WITH VAPOR BARRIER UNLESS OTHERWISE SPECIFIED. Da FIRE ALARM PANEL ® IMP"'PLY AIR DIFPUBER DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE IF APPLICABLE WITH MANUFACTURER'S SPECIFICATIONS AND ACCORDING TO "ASHRAE" POWER EXIST.LIGHT AND " DIMENSIONS STANDARDS. 24 INDICATOR EF 01 RETURN AIR GRILLE DUCT DIMENSIONS ARE IN INCHES AND CORRESPOND t0 INSIDE DIMENSIONS WIDTH X HEIGHT. DUCT SYSTEM SHALL COMPLY WITH Vnc � I j /� O ti Fg 10bTAt 1-FPA" STANDARD NO.WA AND/OR 908. DUCTWORK AND ClaipONENTS EXISTING DRYWALL CEILING. EXISTING TENANT _ SHALL BE CLASS 1 MATERIALS IN ACCORDANCE WITH U.L. 181 � i'. TESTS.PROVIDE FIRE DAMPERS WHEN CROSSING F. RATED WALL OR CEILING. 7'-5`. `��.'/' F=� SUPPLY AIR DUCT E t20 GTANGULAR GR068 SECTION VAC 2. COORDINATE LOCATIONS,SIZES AND OPENINGS WITH OTHER TRADES _ RETURN AIR DUCT RECTANGULAR CROSS,SECTION ON THE JOa. AA_-- CONTRACTOR SHALL r, VIDE THE COMI=LETE DUCT AUDIBLE ALARM A�- SYSTEM A/C W/TURNING VANES AT ALL ELBOWS,SPUTTERS 4 VOLUME DAMPERS,,ULLISTEII A NORMALLY TURNING VANE OCCUPIED AREA OR THROUGH BUILDING FIRE 3. DIFFUSERS SHALL BE SELECTED,LOCATED, AND BALANCED IN ORDER ALARM SYSTEM VOLUME DAMPER M LINE THAT THEY DELIVER THE REQUIRED CFM TO THE ENTIRE ROOM EVENLY IF APPLICABLE AND DRAFT FREE TO MAINTAIN THE FOLLOWING DESIGN CONDITIONS: VOLUME DAMPER AT TAKE OFF RELATIVE INSIDE OUTSIDE HUMIDITY ' FLEXIBLE ROUND DUCT COOLING - 16• DB 91' DB - 19' WB 50% TO 60% � HEATING - 10' DB 45' DB x EVAPORATOR FAN MOTOR SPLItt£R DAMPER AUXILIARY CONTACT TO O 4. ALL FAN UNITS,MOTORS,COMPRESSORS, ETC.SHALL BE ISOLATED, SHUT SMDOWN E NIT IN CASE 8 AS REQUIRED TO OPERATE QUIETLY 50 THAT NOOBJECTIONABLE SOUND WILL BE HEARD IN THE HABITABLE SPACES DUE TO AIR VELOCITY, FAN MOTOR HUM, VIBRATION, OR MECHANICAL MOVEMENT. 5 . AIR CONDITIONING DUCT SMOKE DETECTOR EF �— FIRE DAMPER 5. A/C SYSTEM SHALL HAVE CLEANABLE AIR FILTERS LOCATED AS O OS SMOKE DETECTOR REQUIRED FOR EASY ACCESS151LITY. ® OPPOSED BLADE DAMPER 6. A/C SYSTEM SHALL BE CONTROLLED BY A THERMOSTAT. MOUNT BuPPI AIR DC7C7C7(—'}r''r THERMOSTAT 5'-O" ABOVE FINISHED FLOOR,U.ON (SEE PLAN�) RTC ``--"�"`-�"-11�_JJ ELECTRIC STRIP F+EATER M 1. ALL GRILLS AND DIFFUSERS TO BE STEEL CONSTRUCTION.DIFFUSERS TO METAL 1e0UID FRTNM3 ST HAVE CEILING RADIANT DAMPERS 411# QIADRANr OP£RAT . PROVIDE GASKETS ON ALL GRILLES, to EiE OUT6IDE AT D MOTORIZED DAMPER TITUS OR AIREGUIDE OR APPROVED EQUAL WITH ENAMEL FINISH COLOR BY PROVIDE NtULATI�GN GUARD RD ARCHITECT. U+ERB NECIE"ARY 8. UNDERCUT DOORS I" AFF,AS INDICATED. AIRFLOW �' S. ALL REFRIGERANT PIPING SHALL BE COPPER - TYPE L - A�I-PER�E vOl.l49E x ACR TYPE, DEHYDRATED AND SEALED.ALL FITTINGS SHALL BE rE DtIC WROUGHT COPPER ALL JOINTS SHALL BE MADE WITH HIGH 6tILATED�X'YETHELENE N MA H F'OL SXS TEMPERATURE BRAZING ALLOY OF NOT LESS THAN 5% SILVER WIRE t`ff#FOl N0- 12x12 SEAL JOINT UTH I nQ P P INSTALLATION NOT LESS THAN 1ZE THICK "ACCORDING T LEX". EPDXY 4 DUCT TAPE IXI5TING FIXTURES. FRAI•IE DIMENSIONS LIQUID AND M SUCTION ALT RERSS RECOMMMENDATIIOONCS FOR EQUIVALENT DAMPER MODEL b A 0 c E LENGTH OF PIPING RUN FOR CONNECTED TONNAGE. ALL PIPING AIR ROW GRD-2 STANDARD FRAME 5"-q• 3 VIb NA NA NA ACCESSORIES SHALL BE CONSTRUCTED AS SUGGESTED BY EQUIPMENT 18x MANUFACTURER ALL PIPING SHALL BE EVACUATED PER GOOD EXIST. CRP-20 BOTTOM EXTENSION 5"45• NA 5A4 NA NA PIPING PRACTICE BEFORE START-UP. fn1 OIRD-2T TOP EXTENSION 5"4142" NA NA 1tt NA V PEIlPORATED DrR1bER O 11411•15" NA NA 945" NA -------------- CRD-2BT BOTTOM AND TOP EXT. 5"-111/4" NA NA NA 9 1/8• I I eEAL JJo TD MT TAPE 1145'-15" NA NA NA If 1/6" j TYPICAL DIFFUSER CONNECTION DETAIL GRD.I ANA cJee C NO SCALE �gLe. EX15TING 2X4 ACOUSTICAL CEILING TILE /RE51U NT A ING. ® a„m A O . - THIS MTALLATION 16 DE6sMleD AM TESTED I I E 8'-O" I HR. FIRE RATED O FOR EIT4�R 6TEEL OR FLExlPWUNID)DUGT6 NO.10 SC7QEW WINO.10 6CI�E1116 O "114!!TI-e EM5KANC P"TRATION le LAPOER •24'OC. •24"OC XH THAN THE DUCT 61AM N OUGN GAWIS,THE DAGK OP THE GRILLE OR OM16M MUl5T eE PROTECTED B PRE-FAB CURB � GA&CET 8'Ia WITH THE ADDITION OI'OUR T5-24 THERMAL MLA.%"t O THE DEER 6HALL BE 6USPENDED AT ALL POUR I I METAL CURB COIO+ERe U11TH M2 OZa STEEL UnRE I eulLnule R)�Gr trlcLo"..tl� I L-----------------� , \ .. FLA5WNG STANDARD CONStRI1CtION , WOOD CANT. FRAMEr STEEL RIbID INSULATION O I BLADE R45U•ATIM NON-ASBESTOS UL CLASSIFIED 4"BOLTS•24"O,G REMOVE EXISTING SOFFIT FINISHr MILL GALVANIZED U4NUT6 A WA-*+E" EXISTING FIXTU L 0 AND RECE55ED LIGHT. AIR BALANCING SCHEDULE FUSIBLE LING REPLACEABLE 165•F UL LISTED �1 6PACER / NEW---o' 1 RELOCATE JUNCTION LINO 16 6TANDARD.2121 16 OleTIONAL. 8"a / / BOXES AS REQUIRED. CFM UNIT 6/A RIHTJAIR MARL' UP CPM1 PRESSURE MAXIMUM SIZE% I5"DIAMETER — RTU / 00 ISM AIRCFM --- CFM MMIMU1M SIZEr 5"DIAMETER { 5T'^�/ RTU I 2m� I500 500 --- 4Fs09 8xh \� RM 1;,3 300 .300 EF e4 2340 -2340 D to $/A 03 s°# c 1 SUBTOTAL 1 +2300 -2490 _340 (p NEW U BAR @ " IRTU 2 2000 1500 509 X OA W" :::: + > ROOFTOP UNIT 8 x 8ll* 00 tOTAL8 40 3000 42600 -24W 060 Drawings and Specifications ab inst ucnent of service are and shall remain the ® property of the Architect and shall remain the property of the Architect whether "cop cup" IXI5TING DRYWALL CE I LING. ® ® the project for which they were made is executed or not.They are not to be used 9'-0". in any manner on other projects or extensions to this project except by agreement in writing and with the appropriate compensation to the Architect.Reproduction AIR DISTRIBUTION SCHEDULE ����„� �N�� �' w � of drawings and rfications without the written consent of the Architect is SYMBOL USE CFM TYPE DESCRIPTION MFaRpESRJG 4 MODEV prohibited. CEILING LAY-IN PANE M T'L TITUS• TDC CEILING RADIATION DAMPER MODEL CRD-2 — 4�,, T OA SUPPLY AIR 250 PER1.LAY- 8"+ I0>W N,TA 4k' �.0m"OoF 6TINUCIU M EXISTING BEAM ® " 400 " 106♦ 24X24 " " PAS W4'*yC GODS! O » `LLR70D JOIM OR"UM" © " 100 • g•+ ■ • • • 1111100P DRAN II ,r II *L.O�DMaxi"C0/1+. TO NZ R"T C X • 90 • 4"+ 14XB • . • C14 A/C UNIT (ROOF TOP) `� JOHN R NIEDINA&ASSOCIATES,Architects,Inc. 8a� 4901 SW.75 AV.MIAMI,FL 33155 CEILING Kt/A No SCALE INSTALLATION DETAIL L. offioe(305)740-0354 fex(305)740-5355 R R£T11}eJ AIR --- REGISTER -' 24X24 " tltUb PAR •OR EQUAL /—"X N�T6rEEL Duct FLORIDA CERTIFICATION NUI4IDBIt,RA 14867 t`A CERTIFICATE OF CORPORATE AUTHORIZATION AA0002647 - GA O O s'Io MODEL GRD-I OR a®-1 IXI5TING DRYWALL CEILI ® BREAD GALLERY REMODELATION. `ET ', �CE LM DAMPER) 5784 SUNSET DRIVE TIS 24 —— ——— TO 24 SOUTH NIIAMI,FLORIDA BLANKET FAT &WaL OLLV CONTACT:CESAR&LUISA RINCON(305)663-1179 TM unRe TO JOIGT6 ,MOB y: xxxxx GUERRERO/GONZALEZ I HR PR c>=8-Nrl, GRID LAY-N TYPE STEEL DIPFUSER ENGINEERS, INC. PANEL Michael C. Guertem, P.E. - Mechanical Eng. Uc. /15235 b•cLRARANi=DSTitEEA1 DAPPER Rafael L Gonzalez, P.E. FRAME AND V=T°R°'°`TY°' -- REFLECTED CEILING ALAN HVAC °�`" ria `3155 MAXRUy rlrrlORArt oPENnrci 611E 14"X 14•(6,.ec+ SCALE' 1/4"— I '-O" GW4mi S.W. 73rd Nwnw. Sun. �1o7A , Floflda 33133 Tel. (305) 262-3944, Fax (305) 262-8211 E-mail: GGENCOACCESSPRO.NET CEILING RADIATION DAMPER INSTALLATION REQUIREMENTS G.•��`GA I-� P OR PLAN U r: •SCi&E: AS SHOWN • % r�,i�\IIzAA FEB.'O 1 r ' ,DRAWN: DHB. Ir