Loading...
01-0386-015 DATE REVISIONS BY - � PANEL "A"EXISTING SURFACE MID LIGHTING FIXTURE SCHEDULE BRANCH CIRCUITS TYPE MANUFACTURER CATALOG NUMBER MOUNTING LAMPS REMARKS LOCATION WIRE AND TOTAL BREAKER CKTICKTBREAKEF TOTAL WIRE AND LOCATION CONDUIT V.A TRIP NO.1 NO. TRIP V.A CONDUIT U.C.REFR 412 - 1/2"C 1200 1P-20 1 2 1P-20 1200 012 - 1/2"C U.G. ICE MAKER lc) A COLUMBIA 4PS24-432G-RAA12-4EB8-GLR FLUSH (4)FO32T8/741 2 X 4 LAY IN REF. COUNTER 1500 1 3 4 1000 BACK BAR B PRESCOLITE PBX-TO-71S FLUSH 1-150W CLEAR AL AK HEAT LAMP 900 5 6 1000 SODA SYST. A-19 REFLECTOR HEAL LAMP 900 7 8 900 C PRESCOLITE W B-28 WALL 1A 19w WALL SPHERE ELECTRICAL LEGEND RECEPTACLES DISH MACHINE 1500 9 10 SW RECEPTACLES D DUAL LITE LZ2D SURFACE 2PAR36 SEALED BEAM EMERGENCY BATTERY F—p—L FLUORESCENT STRIP (a) CASH REGISTER E DUAL LITE LXURWE SURFACE LED ® FLUORESCENT LIGHTING FIXTURE - SURFACE MTD. 600 11 12 600 GAS CONTROLS UNIVERSAL EXIT W EMERGENCY BATTERY WALL MOUNTED LIGHTING FIXTURE REFRIGERATOR 13� 13 14 � RECEPTACLES (c) F IMDELITE/EXCELIME C/N RHL-AF-400-MA-FS PENDANT 1-100W 1500 15 16 90m RECEPTACLES A21 4) EXIT LIGHTING FIXTURE SPARE 550 17 18 900 RECEPTACLES (C) G ❑ 2'x2' FLUORESCENT LAY-IN LIGHTING am 19 20 1 500 LIGHTING H Q 2'x4' FLUORESCENT LAY-IN LIGHTING 1100 1 21 122 1 900 LIGHTING (c) O CEILING MOUNTED LIGHTING FIXTURE LIGHTING 1200 23 24 1 900 LIGHTING (c) Q LIGHTING FIXTURE TYPE BAR REC. 600 25 26 Iy00 SHOW WINDOW (c) LIGHTS ON EMERGENCY CIRCUIT SPARE 600 27 28 1500 SIGN (b)(C.) 0I EMERGENCY FIXTURE - BATTERY TYPE SPARE 6mm 29 30 °gym BAR LIGHTS MOTOR RATED SWITCH 20A.120//277 VAC SINGLE POLE TOGGLE SWRCH,SPECIFICATION GRADE 4'-0" SPACE 31 32 SPACE $0 A.F.F. LETTER DENOTES UG14TS SWITCHED. 33 34 THREE WAY TOGGLE SWITCH 20A. 125V, 3 WIRE GROUNDING TYPE SPECIFICATION GRADE DUPLEX 35 36 ELECTRICAL NOTES =0C 20A.1Y5V , 3 WIRE IGROUND TYPE CSPECIFICATION COMPUTER GRADE QUADRUPLEX 37 38 RECEPT. MID. 18" A.F.F. 39 40 I. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE S. MATERIALS, APPLIANCES,DEVICES AND EQUIPMENT SHALL MEET 20A, 125V, 3 WIRE GROUND TYPE SPECIFICATION GRADE DUPLEX NATIONAL ELECTRICAL CODE AND ALL APPLICA15LE LOCAL CODES. WITH THE REQUIREMENTS OF UNDERWRITERS' LABORATORIES AND RECEPTACLE 6" ABOVE COUNTER (U.O.N.) 41 42 2. COORDINATE ELECTRICAL SERVICE W/FLORIDA POWER AND LIGHT SHALL BE NEW AND THE LATEST STANDARD PRODUCTS OF MANUFAC- GFI GROUND FAULT INTERRUPTER COMPANY TUBERS REGULARLY ENGAGED IN THE PRODUCTION OF THE ITEM, SPECIAL RECEPTACLE OF NEMA TYPE AS INDICATED ON PLANS. UNLESS OTHERWISE INDICATED. LIKE ITEMS SHALL BE THE PRO- ® PROVIDE MATCHING PLUG SUBTOTAL 13050 TOTAL ■ 26050 (109 A) 16000 SUBTOTAL 3. ALL TELEPHONE RELATED EQUIPMENT PER TELEPHONE COMPANY DUCT OF A SINGLE MANUFACTURER F FLOOR MTD. RECEPTACLE 1P/20A-12OV. SPECIFICATIONS, Q JUNCTION BOX (a) ISOLATED GROUND I0. ALL CONDUCTORS SHALL BE COPPER AND RUN IN CONDUIT.WIRE c CLOCK OUTLET d. ELECTRICAL INSTALLATION DESIGN OF tH18 PLAN IN IN GOM- SIZE SHALL BE THUN UNLESS OTHERWISE NOTED ON PLANS. PROVIDE � (c) EXISTING PLIANCE AS SET FORTH BY STATE OF FLORIDA STATUTES MODEL GROUND CONDUCTOR PER S O 250-95. I4 TELEPHONE OUTLET, 18' A.F.F. ENERGY EFFICIENCY CODES. . � TELEPHONE OUTLET, MTD 54" A.F.F. 5. THE CONTRACTOR WILL EXAMINE THE JOB SITE AND DETERMINE FOR 11. LOCATION OR OULETS IN ELECTRICAL DRAWINGS IS DIAGRAMMATIC- ® TELEPHONE OUTLET, FLOOR MTD. HIMSELF PRIOR TO SUBMISSION OF BID EXISTING CONDITIONS. CHECK MANUFACTURER'S DRAWING FOR EXACT LOCATION OF OUTLETS. ❑ DATA OUTLET 6. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSED 12. PROVIDE TYPEWRITTEN SCHEDULES FOR ALL PANELBOARDS. SP SPEAKER OUTLET ELECTRICAL CONTRACTOR IT WILL BE HIS RESPONSIBILITY TO SECURE AND PAY FOR ANY PERMITS,CERTICATES D OF INSPECTION, 13. A/C EQUIPMENT WIRING,BREAKER AN FUSE SIZES ARE BASED ON TO THERMOSTAT AS REQUIRED. Q TELEVISION OUTLET A/C EQUIPMENT SPECIFIED ON ORIGINAL CONTRACT DRAWINGS. CON- ® PULL 80X, SIZED PER NEC 1. SUBSTITUTE MATERIALS EQUIPMENT OR METHODS SHALL NOT BE TRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING,BREAKER MADE WITHOUT APPROVAL OF THE ENGINEER IF THE USE OF A AND RISES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE ® ELECTRICAL PANEL, SURFACE MOUNTED SUBSTITUTE REQUIRES ANY CHANGE IN WORK.THE NECESSARY FOR REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS, ® ELECTRICAL PANEL, FLUSH MOUNTED SUCH CHANGE WILL BE BROUGHT TO THE ATTENTION OF THE EN531- AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE. SAFETY DISCONNECT SWITCH, 60-SWITCH SIZE, 3-No. OF POLES, 120/240V " " _400A ML O NEER. AND IF APPROVED, SHALL BE MADE AT NO COST t0 THE CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA 3 , 40-FUSE SIZE, O-NON FUSED 3PHA PANEL B SURFACE MTD OWNER. COST. HACR CIRCUIT BREAKERS MAY BE USED IN PLACE OF RUSES. USE ® MAGNETIC MOTOR STARTER WITH THERMAL OVERLOADS. NEMA 1 ENCLOSURE EXISTING NON-AUTOMATIC SWITCH FOR A/C COND.DISCONNECT. COMBINATION MOTOR STARTER/DISCONNECT SWITCH BRANCH CIRCUITS 8. GLEAN UP SUCH TRASH AND DEBRIS GENERATED BY THE WORK AND T❑®' LEAVE COMPLETED WORK N A GLEAN,UNDAMAGED, AND FINISHED ❑ TRANSFORMER - SIZE/RATINGS As SHOWN LOCATION WIRE AND TOTAL 3REAKERCKTICKTPREAKER TOTAL WIRE AND LOCATION CONDITION READY TO RECEIVE WITHOUT FURTHER PREPARATION, ® MEACAHA I ENCLOSURE LIGHTING CONTACTOR, SIZE AS SHOWN CONDUIT TRIP NO. NO. TRIP CONDUIT UNLESS SO SPECIFIED IN OTHER SECTIONS,ANY ADJACENT OR RTU No2 2"6 - IIIC 5500 2P 1 12 1 2P SPACE ABUTTING WORK TO BE PERFORMED BY OTHERS. ELECTRICAL MOTOR - 3HP SHOWN —F— FIRE HARM CONDUIT LOOP (10 KW) 5500 b0 3 4 30 —� CONDUIT RUN-DOWN TER 3'10 1/2"C 2150 2P 5 6 2P 5500 206 - INC A.W.U.No.l lc) —o CONDUDIT RUN-UP lc) - HEATER 2'15 6 TO EXISTING 0 30 7 8 0 5500 CI0 KW) TOf�'1ER CONDUIT RUN-CONCEALED RAtJSf,- CONDUIT RUN-EXPOSED SPARE 2P 9 10 2P 3000) 24119* - PC COND.No.1 (c) POLE -w�• FLEXIBLE CONDUIT HOMERUN TO PANEL - TICKS INDICATES NUMBER OF WIRES. ALL RE SIZES 0 11 12 60 3000) WIRE INDICATED TO BE 12 AWG, LONG TICK INDICATES NEUTRAL, SHORT 2P 13 14 3P TICKS INDICATES HOT 40 15 16 100 SPARE PANEL "A" 303/0 - 2 0C 13000 2P 17 18 13050 200 19 120 SPACE SPACE 21 22 23 24 Drawings and Specifications as instrument of service are and shall remain the property of the Architect and shall remain the property of the Architect whether 25 26 the project for which they were made is executed or not They ate not to be used RUN CCNOUITS IN BACK OF in any maaner on other projects or extensions to this project except by agreement 27 28 BLDG TO UTILITY POLE IN 29 30 ALLEY lAF'PRDX_TO FT). TgW 320A F?Jl. 1'44.. in writing and with the appropriate compensation to the Architect Reproduction COORDINATE ILV Milt.Co METER of drawings and specifications without the written consent of the Architect Is 31 32 3 0350 MCM,M50 MW O B A prohibited. TFN11d(CU)-30C 33 34 35 36 3'C/0 T"(OJ) 37 38 39 40 3P-3WA �••Ll 41 42 CIRCUIT BMEAKFR •0 (22000 AIC) EXISTING METER IYX11M SUBTOTAL i42550 TOTAL ■ 53550 (129A) 11000 SUBTOTAL JOHN R MEDINA&ASSOCIATES,Architects,Inc. 4901 SW.75 AV.MIAMI,FL 33155 otl3oe(305)740.0554 fax(305)740-5355 3 0350 MCI,N150 MCM(Hl -LEG) TN.IN(CU)-3 1C FLORIDA CERTIFICATION NUMBER,RA 14867 CERTIFICATE OF CORPORATE AUTHORIZATION AA0002647 C13 N - 10 0 1/ (cu)- 3/a"c BREAD GALLERY REMODELATION. 5784 SUNSET DRIVE SOUTH MIAMI,FLORIDA 2-5/8"COFFERCLAA 1sT.LLCIS CXIP MAW-) CONTACT:CESAR&LUISA RINCON(305)663-1179 Cu 617.MIN BLDG.STEEL FOIAJ JOB III: XXXXX ru UNDAT NOT AVAILABLE GUERRERO/GONZALEZ ENGINEERS, INC. lacMoel C.Cuemro. P.E RISER DIAGRAM E a Eng. U x,5235 Rafael L Gonzalez. P.E. NTS Electrical Eng. Uc, 111057 4300 S.W. 73rd Avenue, Suite /107A Miami. Florida 33155 l Tel. (305) 262-3944, Fax (305) 262-8211 i E—mail: CGENCOADDESSPROMET z FLOOR PLAN ( tJ ra ID • U� • r Of'1 : _ 4 : c) SCALE: AS SHOWN DATE: FEB.'01 DRAWN: DHB.