Loading...
01-0320-006 pti N a REMOVE SOFFIT AND EXISTING KITCHEN CABINETS STRUCTURAL LEGEND EXISTING 8x8 CONC. COL. -- - - _ REMOVE WALLS DOORS EXISTING 8x 12 CONC. COL. a a- opLo N W co (D \ NEW CONC. FILL CELL W/ REINFORCEMENT SEE c � REQUIREMENTS ON PLAN �; Q 1- 9 0 0 REMOVE DAMAGED TRUSS — — — EXYf — -I ® � W Q c0 LL' (oo m 00 coQ O ■ I - 0 IR z 7 1-- E PATIO HIM ILfi - - - — — — — — — — r� DEMOLITION NOTE: ■ I f� ��� � �r ka( � j ( REMOVE ALL DRYWALL INSULATION �� — � - ii BEDROOOM DUCTWORK, DOORS WINDOWS DEMOLITION PLAN ( FIRE DAMAGE ) 3/32 — 1 O FAMILY ROOM rY A 1 1 �k�7 DOOR NOTES 5EE 5H EET A-3 FOR DOOR 5CH EDU LES O SAFTY II GLASS DOOR AREA PERMIT BUILT 1997 3 � I CONFIRM STRUCTURAL CONC.COL. I . CONTRACTOR 15 RESPONSIBLE FOR CORRECT ROUGH OPENING FOR EXISTING AND NEW DOOR @ INSTALLATIONS. GLA55 BLOCK CONTRACTOR 15 RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS AND DIMENSIONS 0 A-----A Q PRIOR TO ORDERING DOORS. i 145 5 5 2. EXTERIOR PATIO DOORS EXISTING GLA55 SLIDING WITH HURRICANE SHUTTERS. J -#5 CLOSET O O 3. ALL HARDWARE TO BE 5CHLAGE OR EQUAL UNLESS OTHERWISE NOTED. ° ° ° ° R� THE OWNER 15 RESPONSIBLE FOR SELECTION AND APPROVAL OF ALL HARDWARE PRIOR TO I pW o o i WH W D BLOCK AT SLAB Ll__l LLJ PURCHASING AND INSTALLATION. FINISH OF HARDWARE TO BE SATIN CHROMIUM PLATED. BATH O� ■ �' �-- o SK L Ln A. BEDROOM * BATHROOM DOOR: I ° O 0 u 0 - Z O LOCK SET: LEVER TYPE'HANDLE BATH DINNING KITCHEN 0 i 5T �E O J u_j _j HINGE: 1 112 PAIR 4 x 4 FULL MORTISE HINGES 00 O W W STOP: HAGER BLG2 12 SATIN CHROMIUM PLATED I �j 10'-0" '- 10" 4" 1 W B. CLOSETS * A/C CLOSET DOORS: O _ 10,10.C. 7�� o I) REMOVE SOFFIT AND SOLOTUBE O U� LOCK SET: LEVER TYPE FOR DOORS AND EGG KNOB FOR B(-FOLD � EXISTING KITCHEN CABINETS REF HINGE: 1 112 PAIR 4" x 4" I 0 ° I TRACT: SUSANA HEAVY DUTY B(-FOLD TRACT ° O `0 GARAGE b 4x6 CONC. SLAB O 4. THE FASTENERS TO BE INSTALLED WITH THE FOLLOWING SPECIFICATIONS: I BEDROOM _ �' - - - - - - - - - ° Q Q A. TYPE 1 : 3(PF-3 14) TAPCON 3/1 G" FLAT HEAD AT TOP * BOTTOM OF DOOR FRAME @ 14" ■ I 0 5(PF-3 14) TAPCON 3/ 1 6 FLAT HEAD AT EACH 51DE OF FRAME @@ I G" O.C. MAX. I 13'-0" N 4" - [,,4" I O' " 411 B. TYPE 2: G(PF-3 14) TAPCON 3/1 G" FLAT HEAD AT TOP * BOTTOM OF DOOR FRAME @ 10" O.C. MAX. Ln 5(PF-3 14) TAPCON 3/ 1 G" FLAT HEAD AT EACH 51DE OF FRAME @@ 16" O.C. MAX. CLOSET ° -■�-� @ ONE HOUR FIRE RATED STEEL STORM PANELS (NOT REQUIRED ALL WINDOWS * EXTERIOR WOOD/GLASS DOORS ARE 1 WALLS DOOR O I O RATED IMPACT SAFETY) v 5. A/C CLOSET DOOR TO BE I HR. FIRE RATED DOOR IN GARAGE. LIVING ROOM G. UNDERCUT I " FOR ALL INTERIOR DOOR TO ALLOW RETURN AIR FLOW. I O N BEDROOM 7. DOORS IN MASTER SUIT SHALL COMPLY WITH ADA STANDARDS. – SPRINKLER PUMP I CLOSET CLOSET WINDOW NOTE5 5EE 5H EET A-3 FOR WINDOW 5CH EDU LE5 Ulf OO DOMESTIC PUMP NOTE: ALL WINDOWS TO BE INSTALLED BY SEPARATE PERMIT. I Oi O O FROM WELL 1 . WINDOW MANUFACTURER TO BE ALUMINUM PGT HORIZONTAL SLIDING WINDOWS, ° ° o" ° ° °° ` °° ° #99-0204.03 EXP. 5/20/02. EXIT 145 EXIT H O ALUM. MULLIONS, SECURITY WINDOWS #99-0104.01 EXP. 1102102. FIXED WINDOW ■ 245 PGT #99-0218.01 EXP. 5/20/02. z 2. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS AND DADE COUNTY PRODUCT APPROVAL FOR O ALL EXTERIOR WINDOWS TO BE INSTALLED. 3. CONTRACTOR 15 RESPONSIBLE FOR CORRECT ROUGH OPENING FOR ALL WINDOW INSTALLATIONS. L ROOF LINE CONTRACTOR 15 RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS AND DIMENSIONS j PRIOR TO ORDERING WINDOWS. WINDOW DIMENSIONED GIVEN ARE FRAME OPENING FROM 11__l WINDOW MANUFACTURE. DIMENSIONS ON FLOOR PLAN ARE BASED ON WINDOW FRAME AND I x P.T. BLOCKING EACH SIDE OF JAMB. a 4. THE FASTENERS TO BE INSTALLED WITH THE FOLLOWING SPECIFICATIONS: A. TYPE 1 : 2(PF-3 14) TAPCON 3/1 G" FLAT HEAD AT TOP * BOTTOM OF WINDOW FRAME FLOOR PLAN 1 /411 = 1 ' - O" @ 20" O.C. MAX. 3(PF-314) TAPCON 3/ 1 G" FLAT HEAD AT EACH SIDE OF FRAME @ I G" O.C. MAX. B. TYPE 2: 4(PF-3 14) TAPCON 3/ 1 G" FLAT HEAD AT TOP � BOTTOM OF WINDOW FRAME ET @ 22" O.C. MAX. 3(PF- 3 14) TAPCOM 3/1 G" FLAT HEAD AT EACH SIDE OF FRAME @ I G" O.C. MAX. 0 DOOR 5CH EDU LE Q WINDOW 5CH EDU LE 5. ONLY OF OWNER DECIDED TO CHANGE FROM IMPACT SAFETY GLASS THEN CONTRACTOR IS MARK 51ZE (WxH) TYPE f RAM E FINISH THRESHOLD REMARKS MARK MODEL SIZE TYPE SILL FRAME GLA55 REMARKS TO PROVIDE AS PER ITEM #9. A 34 11x80"x 1 3/8" FLUSH WOOD PAINTED -NA- I D23 38 3/8" x74 3/4" PGT HORZ. SLIDER MARBLE WHITE ALM. GRAY TINT EXIT WINDOW A- 2 G. ALUMINUM FRAME FINISH 15 TO BE WHITE WITH IMPACT GRAY GLA55 TINTED, B 30"x80"x 1 3/8" FLUSH WOOD PAINTED -NA- 2 9040 48 11x 108 3/4" PGT HORZ.SLIDER MARBLE WHITE ALM. GRAY TINT 7. PROVIDED SCREENS TO MATCH ALL WINDOW WIRED WITH ALARM CONTACTS. C 24 11x80"x 1 3/8" FLUSH WOOD PAINTED -NA- 3 23 38 3/8 11x37 3/4" PGT HORZ. SLIDER MARBLE WHITE ALM. GRAY TINT 8. SEE STRUCTURAL PLANS FOR WIND LOAD CALCULATIONS AND ELEVATIONS. D 32 11x80"x 1 3/8" FLUSH WOOD PAINTED -NA- 4 33 38 3/8 11x53 7/8" PGT HORZ SLIDER MARBLE WHITE ALM. GRAY TINT EXIT WINDOW 9. PROVIDE 18 GAUGE GALVANIZED STEEL STORM PANELS WITH REMOVABLE TOP AND E 48 11x80"x 1 3/8" B(-FOLD PLASTER PAINTED -NA- 5 22 2G 11x37 1/3" PGT HORZ SLIDER MARBLE WHITE ALM. GRAY TINT 30F= 8 BOTTOM MOUNTING TRACKS FOR WINDOWS I AND 2. THE CONTRACTOR IS TO PROVIDE F 32 11x80"x 1 3/4" FLUSH WOOD PAINTED -NA- SHOP DRAWINGS AND CALCULATIONS STATING THAT THE STORM PANELS COMPLY WITH G 2G"x80"x 1 3/4" FLUSH WOOD PAINTED -NA- WINDOW NOTE THE SOUTH FLORIDA BUILDING CODE, SECTION 23 15 (IMPACT), SECTION 2309 (WIND PRESSURE) AND SECTION 2303.3 ( DEFLECTION), BOTH OF WHICH ARE TO BE SIGNED H 3G"x80"x 13/4" ENTRY DOOR WOOD PAINTED ALUM. J EXISTING TO REMAIN AND SEALED BY A FLORIDA REGISTERED ENGINEER. K EXISTING GARAGE DOOR TO REMAIN MFR TYPE APROV # EXPIRED 10. ALL WINDOWS USED FOR SECOND MEANS OF ESCAPE SHALL COMPLY WITH N.F.P.A. 10 I L EXISTING GLA55 SLIDING DR. TO REMAIN SECURITY BOX MULLION 99-010.01 1 1/24/01 �� WITH A CLEAR OPENING MAX HEIGHT 44" ABOVE FIN. FLOOR TO BOTTOM OF ALUMINUM PGT SWING DOOR 99-0128.01 I 1/22/01 �•t�z�lo':':■■. ' FRAME. NOT LE55 THAN 20" IN WIDTH AND 24" IN HEIGHT AND 5.7 SQFT. IN AREA. AL50 ALL WINDOWS SHALL HAVE A LOCKING MECHANISM AT MAX. HEIGHT 54". I HR. FIRE RATED OR METAL CLAD DOOR W/ CLOSURE PGT FIXED WINDOW 99-0218.01 05/20/02 PGT HUNG SLIDER 97- 1 1 24. 1 1 07/30/0 I ROBERT a<OGER AIA A itect: AR-0005174 g Dat@ r'