Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
01-0320-003
s -- REMOVE SOFFIT AND -- EXISTING KITCHEN CABINETS STRUCTURAL LEGEND G -EXI5TING-60 CONC. COL. W Co + REMOVE WALLS DOORS _E34I5TIi`1G 8x=1 2 COLIC. COL. 4 Lo pa W 00 (o C V ❑a NEW CONC. FILL CELL W/ REINFORCEMENT SEE � d � m >� REQUIREMENTS ON PLAN o0 TM w lu = a °o ° Y cc 0 0 , W O 11 REMOVE DAMAGED TRUSS E Q0 0 c m a '- � _ � ❑ � a - o/�,� w0� CC0 O � W � T G ( 3 4 I PATIO Vi n I DEMOLITION NOTE: # ' REMOVE ALL DRYWALL INSULATION DUCTWORK, DOORS � WINDOWS DEMOLITION PLAN ( FIRE DAMAGE ) 3/32" = 1 ' - 0" DEDROOOM FAMILY ROOM • I I 4 � 4+d. , DOOR NOTES SEE SHEET A-3 FOR DOOR SCHEDULES 3 AREA PERMIT BUILT 1997 I O O I 1 . CONTRACTOR IS RESPONSIBLE FOR CORRECT ROUGH OPENING FOR EXISTING AND NEW DOOR SAFTY 11 GLASS DOOR CONFIRM STRUCTURAL CONC.COL. 0 INSTALLATIONS. GLASS BLOCK CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS AND DIMENSIONS O O I PRIOR TO ORDERING DOORS. f Q O s Q s Q 2. EXTERIOR PATIO DOORS EXISTING GLASS SLIDING WITH HURRICANE SHUTTERS. F D 1 -#5 I 3. ALL HARDWARE TO BE 5CHLAGE I -#5 CLOSET OR EQUAL UNLE55 OTHERWISE NOTED, a a a a a a o I THE OWNER I5 RESPONSIBLE FOR SELECTION AND APPROVAL OF ALL HARDWARE PRIOR TO I ° o i 20 SQ.IN. VENT z W I i DW , ' BLOCK AT SLAB PURCHASING AND INSTALLATION. FINISH OF HARDWARE TO BE SATIN CHROMIUM PLATED. BATH W Q A. BEDROOM * BATHROOM DOOR: a o SK ' _. I Qo U LOCK SET: LEVER TYPE HANDLE BATH DINNING i KITCHEN 5T �/E O z }-- 0 I HINGE: I 1/2 PAIR 4" x 4" FULL MORTISE HINGES 00 O � W I STOP: HAGER BLG2 1 2 SATIN CHROMIUM PLATED Q 10'-G" '- 10" 4" I 0"O.C. LU B. CLOSETS * A/C CLOSET DOORS: d- E _ SOLOTUBE � ��� ® Ut 0 LOCK SET: LEVER TYPE FOR DOORS AND EGG KNOB FOR BI-FOLD I REMOVE SOFFIT AND O �[ HINGE: 1 1/2 PAIR 4" x 4" c0 EXISTING KITCHEN CABINETS REF I d j TRACT: 5U5ANA HEAVY DUTY BI-FOLD TRACT A IL D GARAGE 4'x6' CONC. SLAG O O , 4. THE FASTENERS TO BE INSTALLED WITH THE FOLLOWING SPECIFICATIONS: I BEDROOM _ n_ o Q A. TYPE 1 : 3(PF-3 14) TAPCON 3/1 G" FLAT HEAD AT TOP � BOTTOM OF DOOR FRAME @ 14" ° I �, O 5(PF-3 14) TAPCON 3/ 1 G" FLAT HEAD AT EACH SIDE OF FRAME @@ I G" O.C. MAX. `� - I 13'-O" N 4" _ ' 1114 10 1 OI 4 B. TYPE 2: G(PF-3 14) TAPCON 3/1 G" FLAT HEAD AT TOP * BOTTOM OF DOOR FRAME @ 10" O.C. MAX. R/A Ln 5(PF-3 14) TAPCON 3/1 G" FLAT HEAD AT EACH SIDE OF FRAME @@ I G" O.C. MAX. CLOSET = ® Q ONE HOUR FIRE RATED I �9 STEEL STORM PANELS (NOT REQUIRED ALL WINDOWS � EXTERIOR WOOD/GLASS DOORS ARE WALLS DOOR O RATED IMPACT SAFETY) i 0 5. A/C CLOSET DOOR TO BE I HR. FIRE RATED DOOR IN GARAGE. 41 A © O I G. UNDERCUT I " FOR ALL INTERIOR DOOR TO ALLOW RETURN AIR FLOW. I O N BEDROOM LIVING ROOM 7. DOORS IN MASTER SUIT SHALL COMPLY WITH ADA STANDARDS. i SPRINKLER PUMP I CLOSET CL05ET o WINDOW NOTES SEE SHEET A-3 FOR WINDOW SCHEDULES O DOMESTIC PUMP a NOTE: ALL WINDOWS TO BE INSTALLED BY SEPARATE PERMIT. I d O O O FROM WELL 1 . WINDOW MANUFACTURER TO BE ALUMINUM PGT HORIZONTAL SLIDING WINDOWS, a o a a as as ° I #99-0204.03 EXP. 5/20/02. O ALUM. MULLIONS, SECURITY WINDOWS #99-0104.01 EXP. 1 /02/02. FIXED WINDOW EXIT �� 145 EXIT 0 - PGT #99-02 - --- 2 #5 0 8.01 EXP. 5/20/02. � (,n 2. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS AND DADE COUNTY PRODUCT APPROVAL FOR z ALL EXTERIOR WINDOWS TO BE INSTALLED. O 3. CONTRACTOR 15 RESPONSIBLE FOR CORRECT ROUGH OPENING FOR ALL WINDOW INSTALLATIONS. ROOF LINE IL CONTRACTOR 15 RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO ORDERING WINDOWS. WINDOW DIMENSIONED GIVEN ARE FRAME OPENING FROM j WINDOW MANUFACTURE. w DIMENSIONS ON FLOOR PLAN ARE BASED ON WINDOW FRAME AND I x P.T. BLOCKING EACH C/ 51DE OF JAMB. a 4. THE FASTENERS TO BE INSTALLED WITH THE FOLLOWING SPECIFICATIONS: A. TYPE I : 2(PF-3 14) TAPCON 3/1 G" FLAT HEAD AT TOP * BOTTOM OF WINDOW FRAME FLOOR PLAN 1 4�� - 1 - Oil @ 20" O.C. MAX. / 3(PF-314) TAPCON 3/1 G" FLAT HEAD AT EACH SIDE OF FRAME @ I G" O.C. MAX. B. TYPE 2: 4(PF-314) TAPCON 3/1 G" FLAT HEAD AT TOP * BOTTOM OF WINDOW FRAME 3 @ 22" O.C. MAX. _ �� H Ef ff-T 3(PF 3 14) TAPCOM 3/1 G FLAT HEAD AT EACH SIDE OF FRAME @ I G O.C. MAX. O DOOR 5CH EDU LE A O WINDOW SCHEDULE 5. ONLY OF OWNER DECIDED TO CHANGE FROM IMPACT SAFETY GLA55 THEN CONTRACTOR IS MARK SIZE (WxH) TYPE FRAME FINISH THRE5HOLD REMARKS MARK MODEL 51ZE (WxH) TYPE SILL FRAME GLA55 REMARKS TO PROVIDE AS PER ITEM #9. G. ALUMINUM FRAME FINISH IS TO BE WHITE WITH IMPACT GRAY GLASS TINTED. A 34"x80"x 1 3/8" FLUSH WOOD PAINTED -NA- I D23 74 3/4 x" 38 3/8" PGT HORZ. SLIDER MARBLE WHITE ALM. GRAY TINT EXIT WINDOW A- 7. PROVIDED SCREENS TO MATCH ALL WINDOW WIRED WITH ALARM CONTACTS. B 30"x80"x 13/8" FLUSH WOOD PAINTED -NA- 2 9040 108 3/4" x 48" PGT HORZ.SLIDER MARBLE WHITE ALM. GRAY TINT 2 8. SEE STRUCTURAL PLANS FOR WIND LOAD CALCULATIONS AND ELEVATIONS. C 24"x80"x ! 3/8" FLUSH WOOD PAINTED -NA- 3 23 37 3/4" x 38 318" PGT HORZ. SLIDER MARBLE WHITE ALM. GRAY TINT 9. PROVIDE 18 GAUGE GALVANIZED STEEL STORM PANELS WITH REMOVABLE TOP AND D 32 11 1 3/8"' FLUSH WOOD PAINTED -NA- 4 33 53 7/8" x38 3/8." PGT HORZ SLIDER MARBLE WHITE ALM. GRAY TINT EXIT WINDOW 3oF= E 48"x80"x 1 3/8" BI-FOLD PLASTER PAINTED -NA- 5 22 37 1/3" x 2G" PGT HORZ SLIDER MARBLE WHITE ALM. GRAY TI NT BOTTOM MOUNTING TRACKS FOR WINDOWS 1 AND 2. THE CONTRACTOR IS TO PROVIDE F 32"x80"x 1 3/4" FLUSH WOOD PAINTED -NA- SHOP DRAWINGS AND CALCULATIONS STATING THAT THE STORM PANELS COMPLY WITH G 26"x80"x 13/4" FLUSH WOOD PAINTED -NA- WINDOW NUTS THE SOUTH FLORIDA BUILDING CODE, SECTION 23 15 (IMPACT), SECTION 2309 (WIND PRES5URE) AND SECTION 2303.3 ( DEFLECTION), BOTH OF WHICH ARE TO BE SIGNED H 3G"x80"x 1 3/4" ENTRY DOOR WOOD PAINTED ALUM. J EXISTING TO REMAIN 10. ALL WINDOWS USED FOR SECOND MEANS OF ESCAPE SHALL COMPLY WITH N.F.P.A. 10 ( DONALD W. SHA CKELFORD P.E.AND SEALED BY A FLORIDA REGISTERED ENGINEER. .EXISTING GARAGE DOOR TO REMAIN MFR TYPE APROV # EXPIRED W.K L EXISTING GLASS SLIDING DR. TO REMAIN SECURITY BOX MULLION 99-010.01 I ��"""" 1/24/01 WITH ••:;%NND A R OPENING MAX HEIGHT 44" ABOVE FIN. FLOOR TO BOTTOM OF ALUMINUM PGT SWING DOOR 99-0 i 28.0 I STRUCTURAL .ENGINEERS AND PLANNERS " •'" '; FRAME. .NOT LESS THAN 20" IN WIDTH AND 24" IN HEIGHT AND 5.7 5QFT. IN AREA. 1 1/22/01 �`�.•'eY, ALSO ALL WINDOWS SHALL HAVE A LOCKING MECHANISM AT MAX. HEIGHT 54 . I HR. FIRE RATED O AL CLAD DOOR W/ CLOSURE 7975 SUNSET DRIVE 1 •,a �.� . PGT FIXED WINDOW 99-02 18.01 05/20/02 PE--24803 fi PGT HORZ. SLIDER 97- 1124. 1 I 07/30/ MIAMI, FLORIDA 33143 _ 01 NOTE: ALL EXTERIOR DOORS WINDOWS HAVE EXISTING HURRICANE SHUTTER ' (sos) 271-ao4o FAx (305) 273-1z10 NOTE: UNDERCUT I " FOR ALL INTERIOR DOOR TO ALLOW RETURN AIR FLOW 'IMPACT GLASS, WHITE ALUMINUM ROBERT KOGER AID Archi Oct: AR-0005174 �� Sl . Date 3J a,