01-0193_2-005 _ No REVISION U,4TE 2"6/1"8 ALL CONDUIT INDICATED IS NON-CORROSIVE 3/4' CONDUIT FPL O.H. PVC NOT LESS THAN 1/2' IN DIAMETER SERVICE EXT'G O POOLPUMP EXT'G METER TIME CLOCK W.P. SURFACE MNT. 0 A PANEL 60 AMP, EXIST'Cs EXIST'G SINGLE PH. SINGLE PH. ® 120/140 120/240 HOUSE PANEL HOUSE PANEL D�SG. 012 (CU) -I/2' G ® (MNTD INSIDE) (MNTD INSIDE) RESIDENCE RESIDENCE POOL 200 AMPS 200 AMPS PANEL PANEL 'B' PANEL 'A' - - 2 1-4P O POOL PUMP o MOTOR GF.I. 0 OUTLET po ��� �1 Cu)1/2�GT TRANSF. 7 _. BOX 4110 (Cu)- 3/4' C _ i 3m�UJ 1211 JUNCTION - - - - ►�_� L[C=1-4T BOX 010 (Cu)- 3/4' G NON CORROSIVE CONDUIT -= 40'-!5' --- -- ALL POOL AND OR SPA PUMP MOTORS SHALL BE --- -- CONNECTED DIRECTLY t0 AN APFROVED TIME CLOCK. EXISITNG ELECTRICAL RISER 85 B5 B5 -�AI3 �- B5 55 B5 15 B5 •�'---'i 5-1 B7 EXIST. 12' 4- (TYP) CONIC. COLUMNS i t0 REMAIN TYPE: ItE EQ MAIN BUS: 200 AMPS 4J SERVICE: 240 V - 10- 3W PANEL 5 NEUTRAL: FULL B5 139 x- B9 B'1 MOUNTING: RECESSED EXISTING MAINS: M.G.B.(200) ' POLES: 32 A.LG.: 10K �•` �- DEM. NO DEM TRIP CON C.Kt C.KT CON- TRIP O DEM DEM. �-----� ; K.V.A K.V.A POLE DUIT WIRE REMARKS N0- N0- REMARKS WIRE DUIT POLE K.V.A KVA_3z 2-30 2-30 1/2 10 A/C UNIT "I 1 2 SPARE 3 4 LIGHT d RECEP 14 1/2 1-15 /C UNIT "I \� EXIS71NCs \ POOL PANEL •�• A/C UNI 02 - 1-15 1/2 14 LIGHT d RECEP 5 6 - ff LIGHT d RECEP 14 I/2 I-15 \- LIGHT d RECEP 14 1/2 1-15 Bl3 Bg B'1 B'1 811,13 � - I-15 1/2 14 LIGHT d RECEP '1 a - 1-15 1/2 14 LIGHT d RECEP 9 10 LIGHT d RECEP 14 1/2 i-15 - 3.0 2-30 1/2 10 A/C UNIT "2 11 12 LIGHT d RECEP 14 1/2 1-15 - 13 14 BATH RECEP 12 1/2 1-20 1.5 SPARE 15 1e. GFI RECEP 12 1/2 1-20 1.5 15.31 2-60 1 6 POOL PANEL 1'1 IS EXT'G JACUZZI 121 3/14 2-610 312 x �- 19 24D � `� �-° I I 5 2-140 3/14 8I W/IH 21 2'• EXT'G A.H.0 6 3/14 2-610 121 4/C E Q U 11�1�E I�l T S C 14 E 1..-�I 1 L.E �L �L �V �L �L 23 24. 11.... CTRICAL FLAi�I 5,41„1FTON 5A� Wa 11 un I tS C 2 / SPARE 25 2. EXT'G COMP. 12 3/4 2-40 12 TU BOLTS 1„10UEL SCALE 1/�I'"=1'-0' J� EER z t 28 29 30 REFRIGERATOR 12 1/2 1-20 12 8�s?�� 1� 115 I-18L��SQ� 31 32 SPARE LOAD CALCULATIO�15: POOL PANEL: -' - - 1 POOL PUMP 121 KW - - I POOL LIGHT 30 KW I SPA LIGHT .10 KW FIRST 10 KW 100% : 10.0 KVA. ELECTRICAL NOTES 1 BLOWER 1.9 KW REMAINDER 20.42 KVA w 40% : 8.16 KVA. --- _ - - I GFI RECEP. 0.8 KW A/C (2 UNITS) ,w 100% : 6.0 KVA. _ - 1.- LOCATION OF LIGHT FIXTURES SHOWN ON TYPICAL FLOOR PLAN ARE SUB-TL POOL EQUIP. 1531 KW TOTAL : 24b KVA ELECTfRICAI LE�FzND APPROXIMATE. VERIFY EXACT LOCATION WITH ARCHITECT AND/ OR + 24kOO W- 240= 103AMP - _ L OWNER 1 REFRIGERATOR 12 KW - - - 2.- ARCHITECTURAL PLAN AND DETAILS SHALL BE REFERRED TO FOR EXACT 1 WATER HEATER 5 KW USE 200 AMP. PANEL SWITCHES t RECEPTACLES LIGHTS t FIXTURES SIGNALING SYSTEM LOCATION OF ALL EQUIPMENT; CONSULT WITH ARCHITECT AND/ OR OWNER 1 JACUZZI 32 KW SWITCH CEILINGS LIGHT o PUSH BUTTON IF ANY DESCREPANCIES ARE FOUND. USING THE SCALE ON THE DRAWING SHALL BE _ ❑ INACCEPTABLE. SUB-TL EQUIP.= 9.4 KVA ' O RR 3.- ALL CONDUCTORS SHALL BE COOPER, INSULATION ON CONDUCTORS SIZES 3-WAY SWITCH RECESSED DOWNLICsHT BELL + O Ll THROUGH # 6 AWG SHALL BE THHN AND THW ABOVE # 6 AWG. CONDUCTORS 1906 SQ. Ft. X 3 WATT e-- 1000 = 511 KVA ® TIME SWITCH WALL LIGHT IQ TELEPHONE SIZES THROUGH # 12 AWG SHALL BE EITHER STRANDED OR SOLID, STRANDED SUB-TOTAL 30.42 KVA ' ONLY FOR # 10 AWG AND LARGER SIZES. e- SINGLE RECEPTACLE —o-- FLUORESCENT STRIP ® FLOOR TELEPHONE AUTHORITY HAVINGTJURISDIICTIIONTHER RACEWAY BE AS PERMITTED BY THE CEILING MOUNTED v1 5.- ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO INSTALL THERMOSTATS DUPLEX RECEPTAGL ® FLUORESCENT 1� INTERCOM STARTERS, CONTROL DEVICES, ETC. FURNISHED BY THE MECHANICAL SPLIT- CIRCUTED CONTRACTOR FOR THE HVAC SYSTEM, AS SHOWN ON CONTROL AND POWER DIAGRAM DUPLEX RECEPTACL TELEVISION OUTLET POLE MOUNT LIGHT 0 FOR EACH DEVICE. 6.- IT SHALL BE THE ELECTRICAL CONTRACTOR'S RESPONSABILITY TO VERIFY THE ® 240V OUTLET FLOODLIGHT 0 THERMOSTAT LOAD RATING OF ALL DEVICES PRIOR TO ORDERING ELECTRICAL EQUIPMENT. LOAD •�� • `�` '�J r��. FIRE ALARM INFORMATION ON DRAWING IS BASED ON INFORMATION PROVIDED BY ARCHITECT/ ® FLOOR OUTLET ® EXIT LIGHT El STATION OWNER TO ENGINEER AT THE TIME OF DESIGN. � 4 I-O JuNTION Box EXHAUST FAN FIRE ALAF'M HORN 7.- ALL FUSES SHALL BE DUAL-ELEMENT WITH INTERRUPTING CAPACITY RATING AS SHOWN. EMI LId'* ,;�` ?INLRb�,,•• SAFETY SWITCH CEILING FAN Q SMOKE DETECTOR 8.- ELECTRICAL CONTRACTOR SHALL COMPLY WITH ALL REQUIREMENTS OF THE PROFESSIONAL';CIVIL TNG"INEER �1 I OCCUPATION SAFETY AND HEALTH ACT OF 1970 (OSHA) ELECTRICAL AND MECHANICAL CERTIFICATE .;48352 N� CIRCUIT BREAKER GROUND FAULT GARAGE DOOR MOTOR GFI 9.- ALL WORK AND MATERIALS SHALL BE GUARANTEED, FOR A PERIOD OF ONE YEAR, INTERMLIff ER TO BE FREE FROM DEFECTS OF WORKMANSHIP OR MATERIALS, FROM THE DATE EXISTING TO OF ACCEPTANCE. .-ELECTRICAL OUTLETS BELOW BASE FLOOD ELEVATION 95MI SW 29 STREET o❑ ELECTRICAL METER DISPOSAL E REMAIN MIAMI, FLORIDA DUPLEX RECEPTACLE ELECTRIC DOOR EXISTING to BE 10.- CONTRACTOR SHALL CARRY LIABILITY AND PROPERTY DAMAGE INSURANCE FOR SHALL BE INSTALLED AT THE HIGHEST PERI�IITED ABOVE COUNTER- E❑ I R �MO�p THE DURATION OF THE PROJECT AND FURNISH PROOF OF SAME TO OWNER PRIOR ELEVATION AND SHALL BE INSTALLED IN INDEPENDANT TO THE COMMENCEMENT WORK. CIRCUITS FROM THOSE IN THE HABITABLE AREA. PROJECT N0.I CADD FILE L DIMMER ELECTRICAL PANEL WP WEATHER -PROOF 11.- ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL .- NO APPLIANCES OR APPLIANCES OUTLET SHALL BE INSTALLED CL4RISA—E1 ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODE. BELOW BASE FLOOD ELEVATION. 3 3 3 ® LOUT VOLTAGE SWITCH Q HIGH HAT 12.- COORDINATE ELECTRICAL SERVICE WITH FLORIDA POWER AND LIGHT COMPANY. A/C COMPRESSORS SHALL BE INSTALLED ABOVE BASE FLOOD ELEVATION DATE LAST ENTRY - NEW CIRCUIT BREAKER. PANELS SHALL BE LOCATED ABOVE BASE FLOOD ELEVATION IT IS SUGGESTED THAT YOU CONFER WITH FLORIDA POWER AND DRAWN by CHECKED by LIGHT TO LOCATE THE ELECTRICAL METER TO COMPLY WITH NR FEDERAL EMERGENCY MANAGEMENT AGENCY REQUIREMENTS DATE ASSIGNED NOV '00 SCALE 1/4" = 1'-0" DRAWING NUMBER � - 1