01-0071-034 FIRE ALAS ���-T-E SPECIFICATIONS 11.- All new wiring installed in ducts, plenums and other spaces used for FIRE ALARM SYMBOLS =_ - - environmental air shall be type FPLP, as per NEC (National BATTERY BACKUP CALCULATIONS ''[�'¶' (,gyp Electrical Code)article 760-61. S�LJ E N C E ®F ®P E RA U 1L®d�1 1 The Fire Alarm System design for Terrace Grill Restaurant located at ■`"` - 5920 South Dixie Highway South Miami,Florida. SYM DESCRIPTION DEVICE 12.- All Alarm notification devices shag be audible and visual and shall be INITIATION DEVICES M4KE 2.- All equipment shall be new and U.L.Listed. done via Speaker/Strobe combination devices. Strobes shall be clear - = STAND-BY MODE xenon type, with intensity of 75 candelas as per Article 4.28 (1) Smoke Detector System Sensor modet #2400 - DEVICE UNIT QTY TOTAL Automatic response functions shall be initiated only by the first fire alarm received. 3.- This Design is based on the building having a Sprinkler Fire through (5)of the ADA guidelines of July 26, 1992 and as per article Additional alarms shall be received, annunciated and shall initiate functions associated Protection System. 4.28.2 & 4.28.3 of the Florida Accessibility Code for Building amps am S exclusively with subsequent alarm. Common alarm function shall not be initiated unless Construction 1997 edition. DQ Duct Detector System Sensor model#DH100P FRCP 0.120 1 0.120 4.- The installation of the Fire Alarm System shall also comply with the the first alarm is returned to normal. NFPA-70 National Electrical code(NEC) 1996 edition and the Florida 13.- Speaker/Strobe and Strobe devices shag be placed 80"(6'-8')above Smoke Detectors 0.00012 3 0.00036 the highest floor level within the space or 6" below the ceiling Accessibility Code For Building Construction 97 edition. The Duct Ductecoors 0.00012 2 0.00024 installation shall also comply with NFPA-101 and NFPA-72. whichever is lower as per ADA guidelines and article 4.28 (6) of the Manual pull station Silent Knight model#PS-SATK The actuation of the fire alarm initiating device shall automatically initiate the function Florida Accessibility Code for Building Construction 97 edition. PU/I Stations 0.0001 4 0.0004 detailed below: 5.- The Fire Alarm System shall consist of an Automatic Fire Detection Voice Panel 0.130 1 0.130 1 MARICE CHAEL, A.I.A. AR0014885 and Notification System. The Fire Alarm System shall be an 14.- The distance from any place to a notification device shall not exceed Silent Knight 5207 with Voice Evac Panel System. 50'as per article 4.28(7)and(8)of the Florida Accessibility Code for ® Water flow switch Provided By Others Total 0.251 THOMAS T. COOPER, A.I.A. AR4486 A.- MANUAL FIRE ALARM PULL STATION - Building construction 97 edition. 0.251 am s x 24 hours = 6.024 Amp-Hour required b_ P P Y battery L- - ------ � Activation of the Manual Fire Alarm Pull Station shall initiate the following functions: 6. L All Alarm equipment for this project shall be rated "POWER 15.- Pull Stations shall be installed at 48"AFF as per article 4.2.5 of the ® Tamper switch Provided By Others .. Florida Accessibility Code for Building Construction 97 edition. 1.- Generate an audible alarm signal at the Fire Alarm Control Panel and at the 7.- The Fire Alarm Control Panel shall have standby battery backup as NOTIFICATION DEVICES BATTERY BACKUP CALCULATIONS r___----_-_-_--__-_-_-----� per NFPA 72, 1996, Article 1-5.2.6 providing battery power 16.- The location of the audible devices has been designed as to be Remote Annunciator Panel. effective) heard 15 d6 above ambient noise level obtained under Wheelock model#E70-2475W-FR with ca ac for the entire system to operate for 0 ou in normal y ALARM MODE 2- Generate an audible alarm signal simultaneously on all areas of the building by mode and then, at the end of the period, for 5 minutes In the normal condition of occupancy as per Article 6-3.2.2 of the NFPA 72, Speaker/Strobe device 75 candelas ADA compliant - means of a Speaker devices. Generate a visual alarm signal simultaneously on emergency mode. 1996 edition., the NFPA 101 article 7-6.3.6, the Florida Accessibility DEVICE UNIT QTY TOTAL Code for Building Construction and the South Florida Building Code. Wheelock model#RSS-2415W-FR amps Amps all areas of the building by the use of Strobe devices or combination Speaker/ 8.- Cable size shall comply with article 760-71 and the cable installation S❑ Strobe device 15 candelas FACP 0.700 1 0.700 - Strobe notification devices. shall comply with the separation and use of conductors and 17.- Duct detectors shall be provided for systems above 2000 cfm in the cables as specified in articles 760-54 and 760-61 of the National downstream supply air ducts and in the air return duct for systems Smoke Detectors 0.055 3 0.165 1 EL 3.- Indicate the location of the Pull Station by displaying, in English, the alarmed p recirculating over 15,000 cfm and serving more than one floor as per ANNUNCIATORS Electrical Code. g p Duct Detectors 0.055 2 0.11 device and its location on the FACP alphanumeric display and on the Remote NFPA 90A article 4-4.1. Activation of a duct detector shall Annunciator alphanumeric display. 9.- Building wiring shall specifically conform with the National Electrical produce a shut down of the air handling units. FF_A_C__R FACP Fire Alarm Control Panel Silent Knight model#5207 Speaker/Strobe (75 Cd 0.133 12 1.596 4.- If selected, transmit a fire alarm signal to the designated third party Security Code article 760 part C for Power-Limited Fire Protection Signal 18.- This design was based on calculations over a set of plans provided Strobe Devices 15 Cd) 0.05 2 0.1 Circuits with emphasis on article 760-52(b)on Power Limited Wiring OTHER Control Station by way of Digital Telephone Dialer. Methods and Materials. to the design engineer. If the post installation on-site tests conducted Voice Panel 1.0 1 1.0 by the authority having jurisdiction determines that, because Sync Module 0.025 3 0.075 unforeseeable conditions or changes in field parameters, the audible Remote Annunciator Silent Knight model#5230 � 10.- MINIMUM CABLE SIZE: g p ® g B.- ELEVATOR LOBBY SMOKE DETECTORS (elevator lobby& machine room) A: #18 AWG Copper(2-#18 FPLP)for:Smoke Detectors, Duct alarm level falls below the required level in specific areas, the Total 3.746 number of audible speaker/strobes shall be increased to comply with 3.746 am s x 0.25 hours = 0.9365 Amp-Hour required b batte U - Activation of the Smoke Detectors (elevator lobby& machine room only) , shall initiate Detectors, Pull Stations, Water and Tamper Switches. p p y battery �- B: #14 AWG Copper(2-# 14 FPLP) for. Speakers, Strobes and the requirements and to the satisfaction of the authority having QV Voice Evac Panel Wheelock model#SCSP-4RP =� "d) ti the following functions: jurisdiction. < 0 Speaker/Strobe notification devices. Total battery capacity for 24 hours = 6.024 + 0.9365 = 6.9605 Amp-Hours (J� 1.- Generate an audible alarm signal at the Fire Alarm Control Panel and at the SM Syncronization Module Wheelock model#SM-12124-R j Remote Annunciator Panel. Provide a 12 Am -Hour battery U > � 4 2- Generate an audible alarm signal simultaneously on all areas of the building by TYPICAL ELEVATOR WIRING p rY Q means of a Speaker devices. Generate a visual alarm signal simultaneously on CONVENTIONAL SYSTEM 918/97 Kss Kitchen Suppression System Provided By Others 0 e, u ;w all areas of the building by the use of Strobe devices or combination Speaker/ _ AUDIO AMPLIFIER CALCULATIONS 1 C Strobe notification devices. NOTE: Smoke Detector equipped with EOL EOL End of Line Resistor (For Voice Panel) 3.- Indicate the location of the Smoke Detector by displaying, in English, the SMOKE DETECTOR ON S additional relay contacts AUDIO AMPLIFIER CALCULATIONS HOISTWAYS E alarmed device and its location on the FACP alphanumeric display and on the As Top Elev Shaft ALARM MODE ._ p p }/ per Mr. Robert I Remote Annunciator alphanumeric display. Weatherbee [(904) 922-3100] DEVICE UNIT QTY TOTAL (D p p y memo of 4/21/95, the Florida H 120v HEAT DETECTORS: INSTALL I W ° `'' 4.- Initiate the Automatic Recall operation of all elevators as follows: Administrative Code for Fire DISTRIBUTION OF ZONES amps amps H;` ONLY IF SPRINKLER HEAD IS a. Recall all elevators to the ground floor upon activation of any alarm Safety of elevators does not PROVIDED. Speaker/Strobe Devices 0.04 12 0.48 per Chief Jim Redcliff from initiating circuit on any floor other than the ground floor. require Smoke Detectors in As elevator shaft. If one is State Fire Marshall, [(904) 922- ZONE TYPE ZONE DESCRIPTION ( 1 watt each) U tom, b. Recall all elevators to the alternate level upon activation of any alarm installed do not tie it into the 3100] directions on memo dated " Total 0.48 Fire Alarm System for power 4/28/95 the Heat Detectors 1 Manual Pull Stations Ent/Exit 1 Fir. O initiating circuit on the ground floor. p 5t 0.48 amps x 0.25 hours = 0.12 Amp-Hour required by battery rJ � Ell or alarm. marked in re are not art of the 2 Smoke Detectors Above FACP Elev. Lobby 1 Fir 5.- Activate the blaming Lights at the elevator lobbies. Fire Alarm gs stem. The elevator St I �� ''�' System. 3 Tamper Switch Stairs 1 Mr. T 6.- If selected, transmit a fire alarm signal to the designated third party Security inspectors have jurisdiction in this St Total battery capacity for 24 hours = 0.12 Amp-Hours ; `� vl Control Station by way of Digital Telephone Dialer. matter. 4 Water Flow Stairs 1 Mr. 0 ° 5 Kitchen Suppression System Kitchen Area C.- DUCT DETECTORS AM s ADD A MINIMUM OF 2 AMP-HOURS TO THE FACP ORIGINAL BATTERY s s W Activation of Smoke Duct Detectors shall initiate the following functions: E SMOKE DETECTOR IN 6 Smoke Detectors Elev. Lobby 2nd Flr CALCULATION. uj f= To other S.D. i X Floor:Elev lobby S ELEVATOR MACHINERY 7 Manual Pull Stations Ent/Exit 2nd Mr. I 1.- Generate an audible alarm signal at the Fire Alarm Control Panel and at the In addition t RGeOneral Alarm and 8 Tamper Switch Stairs 2"d Mr. 1 I Remote Annunciator Panel. Elevator Recall, this smoke 9 Water Flow Stairs 2"d Flr. 2- Generate an audible alarm signal simultaneously on all areas of the building by Detector shall also cause a 10 Duct Detectors Roof Top Units suitable blaming Light to flash � means of a Speaker devices. Generate a visual alarm signal simultaneously on 11 - Not Used all areas of the building by the use of Strobe devices or combination Speaker/ I `M- FACP 12 - Not Used - ------- ---- Strobe notification devices. A s s s Zone 13 - Not Used 3.- Indicate the location of the Smoke Duct Detector by displaying, in English, the E Zone 14 - Not Used ------ - ---------- alarmed device and its location on the FACP alphanumeric display and on the To other S.D. 2 Floor:Elev lobby Zone _ - p p Y 15 Not Used Remote Annunciator alphanumeric display. Relay 2a 16 - Not Used 4.- Shut off the air handling unit and A/C equipment associated with the duct j vuL detector. AM s s s 5.- If selected, transmit a fire alarm signal to the designated third party Security I E 1To other S.D. Grd Floor-Ely.lobby S Control Station by way of Digital Telephone Dialer. E D.- WATER FLOW DETECTORS Recall Alternate Activation of the Water Flow Detectors shall initiate the following functions: ❑ . Recall Designated 1.- Generate an audible alarm signal at the Fire Alarm Control Panel and at the 30 23 NOT,� ❑ Breaker F E�.,f� ,,-. � �- � Remote Annunciator Panel. with shunt r�y A� ± 2- Generate an audible alarm signal simultaneously on all areas of the building by Trip `- Y12v EOL means of a Speaker devices. Generate a visual alarm signal simultaneously on 2S `= ` . 4 I ` V11, ��all -J all areas of the building by the use of Strobe devices or combination Speaker/ Power yr °;, x.tiiTr ji - -> Elev Pit The Subn,? .f,G£c%c' _ rl :'�f''all Strobe notification devices. EOL T� � 0. ar , nv,- t ELEV MACHINERY RM I aI.p ,'ital::1• =i 3.- Indicate the location of the Water Flow Detector by displaying, in English, the T �"C)LJ-'')' D�]�urtn:ert. alarmed device and its location on the FACP alphanumeric display and on the 2� Appr oved °i' ulicingpT,,; U Q Remote Annunciator alphanumeric display. mate _ 4.- If selected, transmit a fire alarm signal to the designated third party Security EOL By I i I_LI 1 Control Station by way of Digital Telephone Dialer. 25 23 I U Q < W E.- TAMPER SWITCHES EOL CJ S GJ S S EOL(mwat3t )amps) i Activation of the Tamper Switches shall initiate the following functions: NEW RELAY (provided by F.A. contractor) i� -� � � CONTROLLED BY FACP 20 21 22 24 2(o L1J 1.- Generate an audible Trouble Signal at the Fire Alarm Control Panel and at the SUPPLY FAN 'CD � 1 g EOL cJCj L_L_I � <<1 r I Remote Annunciator Panel. EXISTING SUPPLY FAN SWITCH N.O. contactor Remove power from coil to open contacts. 2.- Indicate the location of the Tamper Switch by displaying, in English, the troubled \ s e12 THHN In 3/41 c Apply power to con to close contacts SUPPLY FAN CONTACTOR 2 *IS 1=PLP I �` device and its location on the FACP alphanumeric display and on the Remote 2 E72 THHN In s/4" C PROVIDED BY OTHERS. EOL CJ S S EOL(03ss amps) Annunciator alphanumeric display. p TO EXISTING EOL(3 Watts) �� BRANCH CIRCUIT Q ( ' The maximum time period from actuation of the initiating device until initiation of all 12 18 1g related functions as listed above shall be ten seconds. EOL D T All indicating Line Circuits shall be Class B PANEL 14 All notification Appliance Circuits shall be Class B NEW RELAY (provided by F.A. contractor) C, C� EOL(0.iss amps) CONTROLLED BY FACP EOLQ �•/ v EXHAUST FAN 2 *14 1=PLP S 3 � EOL(6 Waite) �� �� � 2 � 8 OPERATION EXISTING EXHAUST FAN SWITCH N.O. contactor The new relays are connected to and Remove power from coil to open contacts. 2 E72 THHN In 3/4" C Apply power to coil to close contacts. activated by the Ansul System. EXHAUST FAN CONTACTOR EOL ■ PROVIDED BY OTHERS. 4 Normal operation Is controlled by 2 *14 FPLP TO EXISTING Y O I C the existing switch which turns on/off R,4 INPUT 24V01 t the exhaust and the supply fens. BRANCH CIRCUIT j --- - - --- - - --- - - - Upon emergency, the Ansul system activates CONNECTED TO FIRE ALARM CONTROL PANE DATE: 10/03/00 _ _ _ _- the now relays so, regardless of the position D I A I t-E j of the switch the supply fan turns off PANEL CENTfR,4L STATION LOB N 0: 001032 --- and the exhaust turns on. I D W N B Y: AW lr-s NOTE SUPPLY & EXHAUST FAN CONTROL SCHEMATIC IC ..,�.,.� � ��.�,,,, � CHK BY: All electrIcal sources (receptacles) located under -- the hood/ventilating equipment (subject to receive the ,jai extinguishing dlacharge) shall be shut off. `c' l 01 C •�•,f , REVISION__ ---- _ • I Turn on the exhaust fan and turn off the supply fan. TOMAS C. ARMSTRBNG, P.A.ENGINEERING CONSULTANTS- EBB 7 5?` •� � - 1 135th Ave.. S-211, A4(pm1 ri�T,T Automatic signal to the fire d 5600 S.W.alarm control penal. To/lws/lee-7152 vo,(305)386-7;W -CMAOvolean T - 3 O f 3 TORUS C. ARMSTRONG, P.E^ 1 EX. PE-17974 e: 1g%0 �0,-`p- .,• �� Sheet