Loading...
01-0071-026 WATER HEATER SCHEMATIC TYPICAL CONDENSATE DRAIN TRAP PLUMBING SYMBOL LEGEND PLUMBING Fl ),"-TUr% L SCHEr[,'-IJLE GENERAL PLUMBING NOTES: SYMBOL DESCRIPTION - P & T RELIEF ---------------66 66-6666-- --------- CAP�_ --- 1. A ALL WORK SHALL BE DONE in accordance with the South Florida SANITARY LINE NO. DESCRIPTION DRAIN CW HW REMARKS Building Code and with all applicable regulations. MARICE CHAEL A.I.A. AR0014885 — — —— VENT LINE —___— B. DRAWINGS: Refer to all drawings for coordination of the , - CLEAN OUT plumbing work. STORM DRAIN LINE P-1 WATER CLOSET 4" V, — A.S. #2234.015 THOMAS T. COOPER, A.I.A. AR4486 DRAIN PAN SD (FLUSH VALVE, SEAT: OLSONITE # 95 C. ARRANGE AND PAY for all permits, licenses, inspections VENT SAFEWASTE LINE FLR MTD) VALVE: SLOAN #111 and tests. Obtain the required certificates and present HOT WATER SUPPLY TO ! STORAGE TANK CD CONDENSATE LINE to owner. RESTAURANT(140' F) 82 GAL GLASS LINED -----------6666 66 66-6666-- -----------------------6666-- D. GUARANTEE: The completed installation shall be fully 18" MIN WEATHER PROOF. PRESSURE — COLD WATER LINE P-1H WATER CLOSET 4" 1" — A.S. # 3043.102 guaranteed against defective materials and/or improper REGULATING PITCH DOWN (FLUSH VALVE, SEAT: OLSONITE # 95 workmanship for a minimum of one year for material and P & T RELIEF -- HOT WATER LINE (TYP.) VALVES TOWARD DRAIN —FLR MTD) VALVE: SLOAN #111 labor. E. ALL HORIZONTAL SANITARY PIPING shall slope at 1/8 per FT CLEAN OUT G GAS LINE for pipes 3" and larger, and at 1/4" per FT for 2" and smaller. Q COLD WATER SUPPLY I FCO FLUSH CLEAN OUT -------- --------- _ 2. SHOP DRAWINGS: Contractor shall submit for approval, within — -----------6666 66 66-6666-- — -- -------- FROM FIRST FLOOR. FD FLOOR DRAIN P-2 LAVATORY 1 1/4" 1/2" 1/2" A.S. #0355.012 30 days of signing contract, a minimum of five copies of fully n 2" MIN ROOF DRAIN (COUNTER TOP) FAUCET: AS # 2385.130 descriptive literature, including but not limited to: water GATE VALVE III RD — WITH 4" CENTERS. heaters, and plumbing fixtures. No work shall proceed without (TYP.) UNION RD_1 PVC ROOF DRAIN (BODY AND DOME) _----—---________ _—_______ ------_---------_-------- the approval of these submittals. CHECK VALVE (TYP.) CO CLEAN OUT P-2A LAVATORY 1 1/4- 1/2' 1/2" A.S. #0355.012, (TYP.) GATE VALVE 1 DRAIN LINE SHALL BE AT LEAST THE (REGULAR, WALL FAUCETAS#2385.130 3. PLUMBING FIXTURES: Fixtures shall be as specified and shall be (TYP.) SAME SIZE AS THE NIPPLE ON THE VTR VENT THRU ROOF HUNG) PROVIDE CONCEALED ARM CARRIER. furnished and installed by this contractor. Fixtures shall be O TERMINATE P&T RELIEF CIRC. PUMP DRAIN PAN RWL RAIN WATER LEADER -----—___________ _—_______ _—------_----------__—_______ complete with drains, traps, supplies and any other accessory �— O LINE AND DRAIN PAN LINE (TYP-) WATER HEATER RWL-1 CLAY PIPE RAIN WATER LEADER P-2H LAVATORY 1 1/4" 1/2" 1/2" A.S. #0355.012, required. L C OUTSIDE, PERVIOUS AREA, (HANDICAP, WALL FAUCETAS#2385.130 4. MATERIALS: _ 6" AFG. TELEDYNE LAARS HUNG) PROVIDE LAV—GUARD # 103 A. PIPING: ` I O to NOTE: ALL EQUIPMENT MOUNTED ON ROOF SHALL # PW-0250—E—N-04—K 3" MIN 6666-- INSULATION KIT, AND a. Soil, waste and vent, and storm: Cast Iron pipe & fittings. v (0 CONCEALED- ARM CARRIER. V INSTALL PER MANUF. Bell & Spigot for undergroundand No—Hub for above. O d• t0 SUITABLE FOR OUTDOOR USE AND SHALL BE SECURED -----------6666-- --- --_ A.S. #6501------------------- r RECOMMENDATIONS. P-3 URINAL 2" 3 4 A.S. # 6501.010 b. Domestic water: Copper pipe, Type L with sweat wrought --F—� M ^ AGAINST HURRICANE WINDS AS REQUIRED BY THE SFBC. / " VALVE: AS # 1662.601 copper fittings. Type M" in concealed spaces is O Ih --------- ------- acceptable. Isolate piping from concrete with / /-� (n O 00 P-4HD ELECTRIC WATER 1 1/4- 1/2" — ELKAY LIEATL-8 insulating material. V J U < M 0 COOLER (HI—LOW) W/S.S. FINISH. c. Condensate drain: DWV Copper pipe and fittings. v — d. Gas line: Schd 40 Black steel pipe with threaded fittings, PIPE PENETRATION DETAIL TYPICAL C L E A N O U T DETAIL ______________ ________ e. Domestic voter supply assembly. Chrome finish tubing o t P-5 MOP SINK 3" 1/2" 1/2 FIAT # TSB-100, with angle shut off valves. D �"I FIAT # 830—AA FAUCET. B. INSULATION: --MOP HANGER # 889—CC. � 2 Hour Fire Rated Through v _________________ _________ _____ ______ a. Condensate drain: 3/4 in. thick, foam plastic —F—J OD a Penetration Firestop for ` 6666—`6666-- insulation, fire resistant type. V) 0 Multiple Metal Pipe through 3735 Green Rd. ® FD FLOOR DRAIN 3" — — JOSAM #30003-5A-50 OR J.R. SMITH a. Hot Water and Hot Water Return: 1" thick foam plastic (�/ •_ Z O O Concrete floors or walls Beachwood, ow, 44122 (TOILET ROOMS) PROVIDE TRAP PRIMERS. insulation, with self sealing flaps. O 0 using FYRE—SHIELD. I I V) t0 ------6666-6666 66 66-6666 66 66---6666---------------6666-- 5. ALL AUTOMATIC GAS voter heaters shall meet the i�U Drawing not to scale FACE OF' WALL (p • FD-1 FLOOR DRAIN 3" — — JOSAM #32120-50-1 standards of the latest energy efficiency code. �'1 0 �p .0 CAJ1047 F—rating = 2 Hr. COVER SECURED --------------666 6--6666-- ------------------------------ n T—rotin = 0 Hr. WITH SCREWS FD-2 FLOOR DRAIN 3" — — JOSAM #49000-3 6. PIPING TEST AND sanitary End do: O � W 1 n 9 (326) g ADJUSTABLE COLLAR A. Test: All sanitary and domestic water supply piping shall --------------666 6--6666-- -----------6666--6666-------- be tested for leaks before piping is concealed or connected U O 1 2 THREADED C.O. PLUG THREADED C.O. PLUG NOTES: 1— A.S.= American Standard to equipment and plumbing fixtures. O L v 1 FIN. FLOOR 2- All exposed trim, such as P-traps, angle stops, and B. Disinfection: All domestic water piping shall be FIN. GRADE STAINLESS STEEL COVER p p g U L-- supplies shall be chrome plated. disinfected b introducin a solution of calcium W SCREWED TO THREADED 3— All plumbing fixtures shall comply with table # 46—R-2 of SFBC. y 9 % 1� �' *'>'il'>'`'' C.O. PLUG. hypochlorite of 50 parts per million of chloride and as per AWWA Standards. .. 7. VALVES: Domestic water valves shall be of bronze body, fsweat ends. W 38 J 4 X 6" DIA. CONCRETE 8. All water connections to equipment shall be protected with vacuum 3B PAD FLUSH W/FIN. GRADE SLIP JOINT 04 breakers as required by code. Q 9. CONTRACTOR SHALL COORDINATE exact location of sanitary, grease, 2 gas, and water piping before starting any work. Notify 1Q Floor or Wall assembly = 4 " thick concrete, Max. area of Architect/Engineer of any deviations from design drawings. opening is 288 sq. in. 10. CLEANOUTS: ® • Nom. 8" diam. or smaller) Sch. 40 (or heavier) steel pipe A. Wall: Josam 58890-15 •Nom. 4 diam. smaller) copper pipe. B. Finished Floor Josam 56020-88-15 •Max, number of pipes with opening is three (3). ® A) Forming Material — (Not shown) — Nom. 1" thick poly— EXTERIOR TYPE FLOOR WALL 11. CONTRACTOR to fire protect and seal all openings and pipe urethane backer rod friction fitted penetrations thru fire rated walls and ceiling. Materials and into opening. methods to fire rating shall be approved by Dade County Product B) Nom. V2 " FYRE—SHIELD thickness installed within opeming. Control. 12. PROVIDE CEILING/WALL ACCESS DOORS where indicated on drawings NOTE: For wall apply FYRE—SHIELD to both surfaces of wall. and when required to access mechanical equipment. Doors shall The pry;•„d In thabove t�;yh be recessed type, fire rated if in fire rated wall or ceilings. Project: .ASTM Ee14(111479)standard Teel Alethod The uc•.e are been °ewnbly and product.have aen to d c and m iv Through Pwelrotbn FYeftopptny bored an both poet vei mtblpoted S manufactured by Karp model an Location: „STM E119(u=!,)stamQe for Fire Teets performance erlterta Tr shall 13. PLUMBING CONTRACTOR SHALL see structural drawings prior to of Suktig Conetruc kn and Yaterlde. nol be Ycble for any ee,dlncl Installer: or canwpu�.41d,r�tt Rem uw Date:2/26/94 Drawin :TR-1047 °'con W—Va or dwlgr. Tremco bidding to fully familiarize himself with project. g ehal only a Mwsl"for reploatn, Signature: Approved by. C. Tuzzeo material round to be defectWe. 14. CONTRACTOR shall provide all neccessory accessories and materials for a complete kitchen equipment installation. Consult with the kitchen consultant's drawings for requirements. 15. CONTRACTOR shall saw cut or core drill existing slabs to install new plumbing work. Patch slab to match existing. } Q GREASE TRAP DETAIL ry z = o C Ca QQ � C MESH REINF 112-00, W Q LJ D x I 0 Q � _ - U) Er L.Li 00 L W 04 � 22"0 OPNG FOR C.I. FRAME & COVER TYP. - TRAFFIC LID, 7" THICK #5 0 7" C.C. V-6" ALL ROUND. #4 0 9" C.C. 12" 2—#5 12" I ALL ROUND. I — I 2 1/2" D B" I DATE: 06.19.00 100 N O: 001032 GAL 750 900 & 1050 1200 1600 2000 W 3-6 3-9 4-0 4-0 5-0 OWN BY: L 7-2 8-0 10-0 12-0 12-0 T MIN. 3 3 3 3 3 CHK BY: jml REINF. 1 6X6 10/10 4X4 4 4 Lagomasino Wp ocia. P.A REVISION: CONC. 3000 PSI, 28 DAY, Consulting Engi e i P - 5 / 5 of S CERTIFICATE OF A TON0 T _MEnANICAL 814 PONCE DE L BLVD -;.:• 7EL.095);. 444-0867 CORAL GABLES, FL. 33134 ,tFAX:(3Q! '441-6979 Shoot 5 �t