01-0071-021 SPLIT A/C UNIT SCHEDULE / FAN SCHEDULE ' I GENERAL NOTES-HVAC UNIT DESIGNATION FC-1 FC-2 UNIT DESIGNATION ' A. - AI-Z WORK SHALL be done in accordance with the South Florida KEF-1 KSF-1 TEF-1 I Building Code and with all applicable regulations. AREA SERVED GR FL 2ND FL H, PKAWINGS: Refer to all drawings for coordination of the HVAC work. AREA SERVED GREASE C. ARRANGE AND PAY for all permits licenses, inspections and tests. NOMINAL TONS 10 10 HOODS TOILET Obtain the required certificates and present to owner. D. GUARANTEE: The completed installation shall be fully guaranteed MARICE CHAEL, A.I.A. AR0014885 15" OPERATING WEIGHT 416 416 LOCATION ROOF ROOF against defective materials and/or improper workmanship for a 1 1" minimum of one year for material and labor. Compressors shall THOMAS T. COOPER, A.I.A. AR4486 DESIGN MANUFACTURER TRANS FAN TYPE UL LISTED K.E. FILTERED SUPPLY ROOF EXH be guaranteed for a minimun of five years. MODEL NO. TWE120 (1) TWE120 (1) FAN WHEEL TYPE & DIAMETER CENTRIF 1. GENERAL SEER, MIN. 9.5 9.5 2. SHOP DRAWINGS: Contractors shall submit for approval, within 30 days DRIVE TYPE BELT BELT DIRECT after signing contract, a minimum of five copies of fully descriptive TOTAL AIR, CFM 4000 4000 w literature, including but not limited to: fans, air conditioning units, hood, U TOTAL AIR, CFM 6000 5400 400 air outlets. No work shall proceed without approval of these submittals. • VENT AIR, CFM SEE 0/A SCHED. Z TOTAL STATIC PRESSURE, IN. OF WATER 1.75 1.5 .375 Q HOOD # 1 Q a --- --- 3. DESIGN PARAMETERS: EXT. STATIC PRESS., INCHES OF H2O .6 B FAN SPEED, RPM SPEED CONT. A. Outdoor design temperature Summer): 91°F DB and 79°F WB • FAN MOTOR H.P. (NON-OVERLOAD) 2 2 0 FAN BHP (MAX) --- --- --- B. Outdoor design temperature Winter): 44°F n O � ___ C. Indoor design temperature Summer): 78°F DB 208V - 3 0 - 60 208V - 3 0 - 60 a FAN OUTLET VELOCITY, FPM MAX --- --- g P %9 ELECTRICAL SERVICE AVAILABLE D. Indoor design temperature Winter): 72°F DB / n V ! 4. ALL THERMOSTATS SHALL have heating mode maximum setting of 75 F and FACE VELOCITY, FPM --- --- FAN MOTOR HP NON-OVERLOAD 3 3 1/8 g g LIJ Q) ' NL-D cooling mode minimum setting of 70 F. The thermostat shall be arranged N! O z o DESIGN AIR ACROSS COIL, CFM 4000 4000 ELECTRICAL SERV. AVAILABLE 208/3/60 208/3/60 115 1 60 to prevent the simultaneous operation of heating and cooling. D U OPERATING WEIGHT LBS --- --- --- J GRAND TOTAL CAPACITY, BTUH 118,910 118,910 5. ELECTRICAL CONTROLS AND POWER WIP.�NG: Under electrical contract. ED o z TYPE OF STARTER/FURNISED BY MXL/MC MRS MC coordinate with elect. dwgs. Comply with F.A. sequence of operation. LU Cy TOTAL SENSIBLE CAPACITY, BTUH 84,770 84,770 EXTENDED VENTED 12" HIGH 12" HIGH U ° .-. 9 10 Z o w COMPANION CURB MODEL N0. 6. EQUIPMENT SPECIFIED BY manufacturers number shall include all !!f O IL � ov ENTERING AIR TEMP, of DB/WB 80/67 p HINGED BASE & GREASE INT. YES NO accessories, controls, etc., listed in the catalog as standard with the O �J 4 Q p O (n equipment. Optional or additional accessories shall be furnished as O L-A --- --- (n BACKDRAFT DAMPER NO NO YES ® _V 2 COIL MODEL N0. specified. r� % ° v O FILTER AND FRAME NO YES NO 7. MATERIALS; V / UA ad �• 0 © O FILTER TYPE & THICKNESS CLEANABLE, 2" CLEANABLE, 2" Q SERVICE SWITCH YES YES YES U 3 w A. DUCTWORK: Q Q C J QUANTITY AND SIZE DESIGN MANUFACTURER COOK COOK COOK a. All supply and return ducts round s iral factory, fabricated v. V 999 L'- ducts with exposed spiral ribbs. Ducts shall be internally lined FACE VELOCITY FPM. MAX. --- --- & MODEL N0. VCR-HP270VH10B 180ASP ACED90C15DM with 1" U.L. duct liner, R-4.2 minimum. p� 0 HEAT/REHEAT COIL TYPE ELECTRIC -� b. All ductwork except for kitchen exhaust ducts shall be W 0 d Of ELECTRICAL SERVICE AVAILABLE 208V - 3 0 - 60 208V - 3 0 - 60 galvanized sheet metal not rated to 2" and 2000 fpm max. �y UW Go 0. w AIR DISTRIBUTION SCHEDULE Ductwork shall be constructed and installed as per SMACNA's LL •- a o 0 CAS_P A F2 T = AUXILIARY ELECTRIC HEAT, KW 11.25 11.25 Sheet Metal Duct Manual. Ld Z Q MFR_R A R T SYMBOL USE TYPE ACCESORIES DESIGN, MFGR. & MODEL No. C. Kitchen hood exhaust air ductwork shall be 16 ga. min. -� D %D V MGV QTY STAGES AND KW/STAGE 1, 11.25 1, 11.25 black iron or galy, steel construction, with all seams I H to 40 UNIT DESIGNATION CU-1A & 1B CU-2A,2B A SUPPLY AIR CEILING DIFFUSER OBD TITUS 250-AA and joints liquid-tight continuously externally welded. Q U $ %D �• provide duct acess panels at all elbows and urns. Ch 0ie TYPE OF FAN PROPELLER Ducts shall be constructed as per NFPA 96. O 11% ' RETURN AIR CEILING FILTER GRILLE TITUS 50FF U 00 Q in Q Z NO. OF FANS AND HP 1 - 1/4 1 - 1/4 g d. All duct dimensions are clear inside dimensions. 0 0 AMBIENT AIR TEMP., oDB 95 95 e. Firestop all rated wall penetrations, submitt U.L. assembly. v ' GAS EQUIPMENT Z C SUPPLY AIR ROUND CEILING DIFFUSER OBD TITUS TMR-AA -I Fn BRANCH CIRCUIT AMPS MIN./MAX. 23/40 23/40 J w 8. TEST AND BALANCE: Contractor shall test and balance all ventilation W LU M NO. OF COMPRESSORS 1 1 Z p EXH. AIR EXHAUST REGISTER OBD TITUS 50F and air conditioning systems. Submit four copies of Test and Balance Q a' REF. PIPE SIZE SUCT./LIQ. (O.D.) 1-1/8/3/8' 1-1/a/3/8' Report to Owner for approval. CAPACITY REDUCTION 0-100% 0-100 9. CONTROLS: 0 20.9 FLA 20.9 FLA OUTDOOR AIR CALCULATIONS AS U U UNIT TOTAL AMPS A. Air conditioning systems shall be started and stopped thru Of ELECTRICAL SERVICE AVAILABLE 208V - 3 0 - 60 208V - 3 0 - 60 AREA FLOOR PERSONS TOTAL CFM CFM CFM CFM SYSTEM programmable thermostat. Individual thermostats shall start/atop a DESIGNATION AREA 1000 FT2 PERSONS PERSONS FT2 REQUIRED PROVIDED DESIGNATION supply fans and activate cooling/heating systems as selected. OPERATING WEIGHT 239 239 Activation of any unit smoke detector shall shut down all RTU's DINING --- --- 120 (1) 15 =900 900 FC-1=450 and activate fire alarm system. DESIGN MANUFACTURER TRANS TRANS 2(2) FC-2=450 MODEL NO. TTA060C TTA060C H. Hood and exhaust system: Hood # 1 & 2 SE PLANS (1) PROVIDE INTERTWINED SPLIT COIL a. Supply and exhaust fans are interlocked with pilot light Duct # 1 & 2 SEE PLANS in kitchen area. b. Fire mode requires exhaust fan continues to operate and NOTES supply fan stops. - FIELD PIPE DROPS AS SHOWN EXHAUST HOOD SCHEDULE C. Hood exhaust fans shall operate whenever the extinguishing SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY CAS 1 USER PROJECTED OCCUPANCY system is activated. - RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, HOOD ( ) 3' • SALAMANDERS, ETC. DESCRIPTION HOOD # 1 (2) HOOD # 2 (2) (2) LESS THAN 3 HOUR PEAK OCCUPANCY DURATION. d. Fixed pipe extinguishing systems is a single hazard area - MAXIMUM 9 ELBOWS IN SUPPLY LINE. - MINIMUM 72 INCHES OF AGENT LINE FROM TANK TO FIRST NOZZLE. SERVICE GREASE EXH. GREASE EXH. shall be arranged for simultaneos automatic operations upon Q - IF APPLICABLE, PRE-PIPED CHARBROILER DROPS ARE SHIPPED LOOSE. activation of anyone of the systems. Q - FACTORY PIPING EXTENDS A MAXIMUM OF 6" ABOVE THE TOP OF THE HOOD. EXHAUST AIR 3000 3000 - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOKING SURFACE QUANTITY (CFM) 10. Verify that all ductwork fits in ceilings prior to fabrication. Offset SIZE, NOT THE OVERALL APPLIANCE SIZE. MAKE-UP AIR QUANTITY 0 0 ducts and pipes as required, at no additional cost to owner. V O - - THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS CFM INTO HOOD CL z = � a • EXHAUST DUCT 3000 =1935 3000 .1835 �� nn Q d. � CALCULATION 1.55 FT2 FPM 1.55 FT2 FPM V ' FACTORY PIPING 0, � Q HOOD DIMENSIONS 10' X 4' (1) 11' X 4' (1) KEF-1 FIELD PIPING DUCT SIZE (OUTLET) 14" X 16" 14" X 16" 1 W W GREASE KEF-1 VENTED CURB U Q COLLECTOR. _ " DUCT SIZE (INLET) --- --- i 0 NON KITCHEN HOOD FIRE PROTECTION SAVAIR MODEL CL-DW CL-DW FIN. ROOF. o0 z ?N COMBUSTIBLE J =1 X p O1 SYSTEM SHALL BE A CARTRIDGE CHEMICAL TYPE WHICH WILL PROVIDE AUTOMATIC UL FILE 14692 14692 HINGED FAN � a0 ROOF DECK - L_L_� BASE �,�,�r,°'- �`• '•' s;,k; `j1� i'�= � a FLOODING IN THE HOOD/DUCT AREA ABOVE FILTER BANKS IN ADDITION TO THE REQUIRED + =%^�- SURFACE FLOODING. SYSTEM SHALL BE U.L. LISTED, ANSUL R-102 OR APPROVED EQUAL. (1) CAPTURE AREA FIRE RATED, ENCLOSURE FIRE RATED ENCLOSURE ":::;w• "^ "�'''"'�"`�°`'�`� qA O2 NOZZLES SHALL BE SELF CLOSING TYPE CAPABLE OF PROVIDING VARIOUS STREAM PAT- (2) PROVIDE HOOD MOUNTED CONTROL PANEL AND ALL ASSOCIATED INTERLOCK PROVIDE 6 CLEAR ALL PROVIDE 6 CLEAR ALL I TERNS. WIRING AS REQUIRED BY FIRE ALARM/ANSUL SYSTEM. AROUND DUCT. AROUND DUCT. COORDINATE WITH ELECTRICAL DRAWINGS/CONTRACTOR, WIRING IS TO BE INSTALLED •,�_. .._---- O3 NON-COMBUSTIBLE AUTOMATIC FUEL SHUT-OFF ASSEMBLIES SHALL BE FURNISHED IN ACCORDANCE WITH NFPA BY THE ELECTRICAL CONTRACTOR. DEVICES ARE TO BE PROVIDED BY o LIBL 96 WITH ALL REQUIRED GAS VALVES OR MICRO-SWITCHES, CUTOFF RELAYS AND CONTRAC- THE MECHANICAL CONTRACTOR. Z X CONCRETE SLAB TORS. g N ® ALL EXPOSED PIPING AND FITTINGS TO BE CHROME PLATED. 16X14 16 GAUGE GALV. FILL-IN O5 ENTIRE ASSEMBLY AS PER NFPA 17, 17A, 96 AND AUTHORITY HAVING JURISDICTION. �- FILL-IN PANEL, 22X20 16X14 PANEL © SUBMIT SHOP DRAWINGS. SECURE SEPARATE PERMIT FOR HOOD FIRE SUPPRESSION SYSTEM. NON-COMBUSTIBLE 61' (TYPICAL) O7 AS MANUFACTURED BY ANSUL OR APPROVED EQUAL AND SHALL BE U.L. LISTED. WALL ANSUL R-102 OR EQUAL 2'-0" HOOD # 2 HOOD 2 HOOD 1 ® VERIFY LOCATION OF MANUAL PULL STATION, HOOD FIRE SUPPRESSION CONTROL (REFER TO HOOD 2'-0" CAPTURE AREA. " � � AREA. PANEL/CABINET AND AGENT WITH ARCHITECT STORAGE TANK(S) PRIOR TO INSTALLATION. SCHEDULE). 10 -0 CAPTURE AREA. 11 '-0" CAPTURE AREA. MOUNT PULL STATION 48" ABOVE FINISHED FLOOR. 4'-0" CAPTURE AREA. - UL CLASSIFIED HOOD, SEE SCHEDULE. 22 GAUGE STAINLESS - RATE: P 0 NOTES AND DST . 22 GA. STAINLESS 6" � STEEL PLATE OR TILES 6" MIN. (TYPICAL iD I>tATE: 10.18.00 HOOD FIR PR OT . I zoa NO: 001032 STEEL PLATE. ` 0 SHOP DWGS. FOR THE HOOD PROTECTION SYSTEM SHALL BE SUBMITTED PRIOR TO OBTAINING PERMIT. GAS COOKING P W N B Y:KKN TESTING AND INSPECTIONS EQUIP. GAS COOKING EQUIP. FINISHED FLOOR. CHIC BY: 1. IT IS THE CONTRACTORS RESPONSIBILITY TO CONTACT THE FIRE MARSHALL'S OFFICE FOR s1II0&Associates, PA INSPECTION AND TESTING OF THE FIRE ALARM SYSTEM AND THE HOOD FIRE PROTECTION SYSTEM. I I Consulting Eiigineers REVISION: SCHEDULE THE APPOINTMENT 48HRS. BEFORE YOU NEED THE TEST. 814 Ponce De Leon Blvd. AC -Co Gables, L 33134 3 HOOD 1 & 2 SECTION HOOD 1 & 2 ELEVATION 3 of 3 - = NTS NTS Sheet 3