01-0071-007 TYPICAL CONDENSATE DRAIN TRAP PLUMBING SYMBOL LEGEND PLUMBING FIXTURE SCHEDULE GENERAL PLUMBING NOTES: SYMBOL DESCRIPTION PERFORATED CAP�_ ------------- --------- ----------- --------- --- 1. A. ALL WORK SHALL BE DONE in accordance with the South Florida SANITARY LINE NO. DESCRIPTION DRAIN CW HW REMARKS Building Code and with all applicable regulations. CLEAN OUT VENT LINE B. DRAWINGS: Refer to all drawings for coordination of the MARICE CHAEL, A.I.A. AR001488 — — — —— --------- ----------- --------- -------- plumbing work. SD STORM DRAIN LINE P-1 WATER CLOSET 4" 1" — A.S. #2234.015 C. ARRANGE AND PAY for all permits, licenses, inspections THOMAS T. COOPER, A.I.A. AR448 DRAIN PAN SAFEWASTE LINE (FLUSH VALVE, SEAT: OLSONITE # 95 and tests. Obtain the required certificates and present FLR MTD) VALVE: SLOAN #111 to owner. 18" MIN CD CONDENSATE LINE D. GUARANTEE: The completed installation shall be fully COLD WATER LINE P-1H WATER CLOSET 4" 1" — A.S. # 3043.102 guaranteed against defective materials and/or improper PITCH DOWN HOT WATER LINE (FLUSH VALVE, SEAT: OLSONITE # 95 workmanship for a minimum of one year for material and TOWARD DRAIN FLR MTD) VALVE: SLOAN #111 ______ labor. ——— HOT WATER RETURN ------------- --------- ---------- ---------- — CLEAN OUT E. ALL HORIZONTAL SANITARY PIPING shall slope at 1/8 per FT G GAS LINE for pipes 3" and larger, and at 1/4" per FT for 2" and smaller. FCO FLUSH CLEAN OUT FD FLOOR DRAIN ----------- --------- ---------- ---------- --------- 2. SHOP DRAWINGS: Contractor shall submit for approval, within 2" MIN P-2 LAVATORY 1 1/4" 1/2" 1/2" A.S. #0355.012 30 days of signing contract, a minimum of five copies of fully RD ROOF DRAIN COUNTER TOP) FAUCET: AS # 2385.130 descriptive literature, including but not limited to: water WITH 4" CENTERS. heaters, and plumbing fixtures. No work shall proceed without RD-1 PVC ROOF DRAIN (BODY AND DOME) __—__________ ______�—_/ ___ _____ __________ _-------- the approval of these submittals. 2A LAVATORY 1 1 4 CO CLEAN OUT r n P— " 1 2" 1 2" A.S. 0355.012, V I DRAIN LINE SHALL BE AT LEAST THE (REGULAR, WALL FAUCETAS#2385.130 3. PLUMBING FIXTURES: Fixtures shall be as specified and shall be SAME SIZE AS THE NIPPLE ON THE VTR VENT THRU ROOF HUNG) PROVIDE CONCEALED ARM CARRIER. furnished and installed by this contractor. Fixtures shall be O DRAIN PAN RWL RAIN WATER LEADER __—__________ _______—_ ___________ _ ______ complete with drains, traps, supplies and any other accessory I— �p RWL-1 CLAY PIPE RAIN WATER LEADER P-2H LAVATORY 1 1/4- 1/2" 1/2" A.S. #0355.012, required. OM (HANDICAP, WALL FAUCETAS#2385.130 4. MATERIALS: HUNG) PROVIDE LAV—GUARD # 103 A. PIPING: I E 3" MIN INSULATION KIT, AND a. Soil, waste and vent, and storm: Cast Iron pipe & fittings. U M O O CONCEALED ARM CARRIER. O V ------------- --------- ----------- ---------- _ _______ Bell & Spigot for undergroundand No—Hub for above. O W (p � P-3 URINAL 2" 3/4" --- A.S. # 6501.010 — b. Domestic water: Copper pipe, Type L with sweat wrought Ih ^ O VALVE: AS # 1662.601 copper fittings. Type "M" in concealed spaces is (f) O M Oa acceptable. Isolate piping from concrete with O 0 P-4HD ELECTRIC WATER 1 1/4" 1/2" — ELKAY # LIEATL-8 insulating material. (J� Q M COOLER (HI—LOW) W/S.S. FINISH. c. Condensate drain: DWV Copper pipe and fittings. TYPICAL C L E A N O U T DETAIL d. Gas line: Schd 40 Black steel pipe with threaded fittings. p P-5 ------M---OP ---- ------ — ----------- — ------ -------- e. Domestic water supply assembly. Chrome Finish tubing Q) OJ Li V SINK 3" 1/2" 1/2" FIAT # TSB-100, with angle shut off valves. O ILL FIAT # 830—AA FAUCET. B. INSULATION: MOP HANGER # 889—CC. r L0 ------------ --------- ----------- --------- _—___--- a. Condensate drain: 3/4 in. thick, foam plastic —jJ — 00 a insulation, fire resistant type. fn ,_ O FD FLOOR DRAIN 3" — — JOSAM #30003-5A-50 OR J.R. SMITH a. Hot Water and Hot Water Return: 1" thick foam plastic _ Z O O (TOILET ROOMS) PROVIDE TRAP PRIMERS. insulation, with self sealing flaps. 5 � FACE OF WALL -- ---------- -------- --------- 5. ALL AUTOMATIC GAS water heaters shall meet the LLI co FD-1 FLOOR DRAIN 3" — — JOSAM #32120-50-1 standards of the latest energy efficiency code. nn O CD J COVER SECURED ------------- --------- ----------- ------ — --------- LL Fell. WITH SCREWS ADJUSTABLE COLLAR FD-2 FLOOR DRAIN 3" — — JOSAM #49000-3 6. PIPING TEST AND DISINFECTION& O 00 0 _ 1 A. Test: All sanitary and domestic water supply piping shall THREADED C.O. PLUG THREADED C.O. PLUG ------- be tested for leaks before piping is concealed or connected O U O LLJ NOTES: 1— A.S.= American Standard to equipment and plumbing fixtures FIN. GRADE FIN. FLOOR 2— All exposed trim, such as P—trops, angle stops, and B. Disinfection: All domestic water piping shall be v STAINLESS STEEL COVER supplies P g U -� pplies shall be chrome plated. SCREWED TO THREADED disinfected by introducing a solution of calcium W 3— All plumbing fixtures shall comply with table # 46—R-2 of SFBC. C.O. PLUG. hypochlorite of 50 parts per million of chloride and as IH per AWWA Standards. .. 0 7. VALVES: Domestic water valves shall be of bronze body, ___I sweat ends. LLJ 4 X 6" DIA. CONCRETE 8. All water connections to equipment shall be protected with vacuum PAD FLUSH W/FIN. GRADE SLIP JOINT breakers as required by code. 9. CONTRACTOR SHALL COORDINATE exact location of sanitary, grease, T gas, and water piping before starting any work. Notify U Architect/Engineer of any deviations from design drawings. 10. CLEANOUTS: A. Wall: Josam 58890-15 B. Finished Floor Josam 56020-88-15 EXTERIOR TYPE FLOOR WALL 11. CONTRACTOR to fire protect and seal ell openings end pipe penetrations thru fire rated walls and ceiling. Materials and methods to fire rating shall be approved by Dade County Product Control. 12. PROVIDE CEILING/WALL ACCESS DOORS where indicated on drawings and when required to access mechanical equipment. Doors shall be recessed type, fire rated if in fire rated wall or ceilings. As manufactured by Karp model RDW and KATR. 13. PLUMBING CONTRACTOR SHALL see structural drawings prior to bidding to fully familiarize himself with project. 14. CONTRACTOR shall provide all neccessary accessories and materials for o complete kitchen equipment installation. Consult with the kitchen consultant's drawings for requirements. 15. CONTRACTOR shall saw cut or core drill existing slabs to install new plumbing work. Patch slab to match existing. w (- WATER HEATER SCHEMATIC PIPE PENETRATION DETAIL GREASE TRAP DETAIL Z c2 F U OJ C P & T RELIE 2 Hour Fire Rated Through v MESH REINF W ILL Q Penetration Firestop for 0 c' Multiple Metal Pipe through ® W = 3 Creep Rd. Concrete floors Or WOIIS Beachwood. OH. 44122 r � STORAGE TANK using FYRE—SHIELD. I I U Q = Drawing not to scale I HOT WATER SUPPLY TO 1 82 GAL CAPACITY GLASS LINED VENT I 3:INSULATED AND W/ WEATHER CAJ1047 F—rating = 2 Hr. r O RESTAURANT(140• F) PROOF JACKET T—rating = 0 Hr. i _ W �� —� v ' (/) PRESSURE (326) I I LLI O REGULATING (TYP.) RELIEF VALVES 2 1 L — — — — — — — — L1J �/ N ` — � 22"0 OPNG FOR C.I. COLD WATER SUPPLY ' FROM FIRST FLOOR. FRAME & COVER (TYP.) ,�;�;•R � �" �`:• GATE VALVE TRAFFIC LID, 7" THICK I �I (TYP.) UNION 3B #5 ® 7" C.C. �6" ALL ROUND. CHECK VALVE (TYP.) 38 4 ® 9" C.C. (TYP.) GATE VALVE ! # (TYP.) 2 12 _ —. TERMINATE P&T RELIEF CIRC. PUMP 1Q Floor or Wall assembly = 4 " thick concrete, Max. area of I 2—#5 LINE AND DRAIN PAN LINE (TYP.) WATER HEATER opening is 288 sq. in. 12" I ALL ROUND. OUTSIDE, PERVIOUS AREA, ® - Nom. 8" diam. (or smaller) Sch. 40 (or heavier) steel pipe —� 6' AFG. TELEDYNE LAARS "Nom. 4" diem. (or smaller) copper pipe. I — NOTE: ALL EQUIPMENT MOUNTED ON ROOF SHALL BE # PW-0250—E—N-04—K a Max. number of pipes with opening is three (3). 1 2 1/2- SUITABLE FOR OUTDOOR USE AND SHALL BE SECURED INSTALL PER MANUF. ® A) Forming Material — (Not shown) — Nom. 1" thick poly— I D 8" urethane backer rod friction fitted I RECOMMENDATIONS. AGAINST HURRICANE WINDS AS REQUIRED BY THE SFBC. into opening. I B) Nom. X " FYRE—SHIELD thickness installed within opeming. NOTE: For wall apply FYRE—SHIELD to both surfaces of wall. The Product.ueed to the above aenmbly hove Project: been teat In oroordanae WAh the rdloebrq: The oboes deeeatbed annaftly and •ASTM Est4(LL1479)Stondad Teri Method producte hove been tested and are DATE: 06.19.00 Location; for TMougl,Pmetretion Fleelopptnq. bo.ed an both post and ordlclpated •ASTM E119(UL M)Standard for Fire Terie Von-M WKWIO. TremCV 001 of suldnq Conriruattan and Yrierlale. Von Noble for any damor%dhect n \/ Installer: °c-eagw tbl,..WtIng rrom u~ Date 2/28/94 Drawing:TR-1047 d;;,�y a tea„ 'a afar;e,� GAL 750 900 & 1050 1200 1600 2000 Signature: Approved by. C Tuneo material fond to be defecthe. JOB NO: 2 W 3-6 3-9 4-0 4-0 5-0 DWN BY: L 7-2 8-0 10-0 12-0 12-0 T MIN. 3 1 3 3 3 3 CHK BY: Iml REINF. 6X6 10/10 1 4X4 4/4 CONC. 3000 PSI. 28 DAY. La ii ,o $ Associates, P.A REVISION: 'Crinsilting.tin gin eers:: ��' �" P — 5 R. /. 5 of 5 CERTIFIC�TE;•OF AUTHORIIZ ECHANICAL 814 PONCE D -LEON BLVD. r •" TEL.:(305) 444-0867 CORAL`GABLE L,X33134 ',,• FAX:(305) 441-6979 Sheet 5 J, •'+ r