Loading...
01-0071-002 UNIT MOUNTED ON ROOF CURB AND F_ - - - - - - � F- - - - - - - SECURED TO CURB WITH 1" WIDE 22 GA STRAPS, STRAPS SECURED TO BEAM WITH #10 SCREWS I I MARICE CHAEL, A.I.A. AR00 4885 I I I I THOMAS T. COOPER, A.I.A. A34486 NEOPRENE PAD ANCHOR UNIT FIRMLY WITH 3/8" BOLTS I I I (MIN. PER SIDE) FOR HURRICANE PROTECTION I I TERRACE BELOW JUNIOR I BEAM PITCH PAN I L_ - - - - - - - - - - - - - - - - — — — — — J (ALL LEGS) 4" DIA. GALV. 24" PIPE (TYP.) WELD (TYP.) FIN ROOF I ELEV. SLAB I (O I ROOF SU RTS 022 I 20 I w Q) 3 I O @30 X 20 10" X 10" X 3/8" STEEL PLATE I CU-2B CU-2A CU-18 I I I I I I I I I I C SECURE TO ROOF SLAB WITH (4) 0 5/8" TAP CONS U W O 0 F (� 5 <�- O IN III iiiiiiiiiiiiiii INS C/O 0 I '2X'2 Q °CONDENSING UNIT MOUNTING DETAIL KEF— o N.T.S. I I I I � CU-1A TEF-1 • I 8d ~ • � m -� W — O a - - - - - - - - - - - - - - - - - - - � I zc g © I w _c_ nom ' 00o , O U c" oll O yW U J I i 0 � I KSF-1 I VENTED GALV. SHEET METAL HOOD W/ WEATHERTIGHT I I w SEAMS AND WELDED SKIRT I I Q GALV. SHEET METAL OR FLEX-TUBE COLLAR — U SLOPE PIPES AWAY FROM HOOD 0 16"x16" OPENING GALV. FASTENERS APPROX. 6" O.C. ROOF P L A N SCALE: 3/16"=1 '-0" 09 REFRIG. PIPES w NOTE: PIPING HOOD PROVIDED BY THIS CONTRACTOR FLASHING BY ROOFING CONTRACTOR. �-- HVAC KEY NOTES U ROOF PENETRATION DETAIL FOR REFRIGERANT PIPES O KITCHEN EXHAUST DUCT UP IN SEPARATE FIRE RATED ENCLOSURE. z w N.T.S. HVAC DESIGN REQUIRES: YES NO PROVIDE 6" CLEAR ALL AROUND. Q �— Q 0 DUCT SMOKE DETECTOR X O KITCHEN MAKE—UP AIR DUCT UP IN SEPARATE RATED ENCLOSURE. z = FIRE DAMPER(S) K 3O REFRIGERANT PIPES UP THROUGH ROOF IN VENTED PIPE CURB. w �0 SMOKE DAMPER(S) X 40 1OX10 EXHAUST DUCT UP IN SEPARATE RATED ENCLOSURE :D LL. FIRE RATED ENCLOSURE X W } FIRE SMOKE FIRE RATED ROOF FLOOR O 120/1/60 ELCET.PSERV. INSTALL PER MFGRG RECOMMENDATIONS. X CEILING ASSEMBL X w Q FIRE STOPPING X U6 DUCTS OFFSET AT 3RD FLOOR CEILING TIGHT TO STRUCTURE. ( � Q V J SMOKE CONTROL X O7 LOCATE 0/A INTAKES MIN. 10'-0" FROM VENTS AND EXH. OUTLETS. J I Q 1/4" BOLTS 20" O.C. ALL D OU) � AROUND (2 BOLTS ON SERVICE M N EACH SIDE MINIMUM) DISCONNECT SWITCH 0 (� NAIL 6" O.C. MIN. PER SIDE ALUMINUM FAN X z COUNTERFLASHING HOUSING m PREFABRICATED NEOPRENE SECURE TO STRUCTURE WITH O FAN CURB GASKET m 0 PSR TYPE HANGER CONCRETE INSERTS '---NAILER CONCRETE SLAB a, ROOFING MATERIAL STRIP I ----THERMAL & ACOUSTICAL ROOF INSULATION INSULATION DAPER FT D P 3/8" RODS AND HARDWARE PREFABRICATED SECURED TO SLAB DATE: 10.18.00 WITH 1/4" TAPCONS AT 6" O.C. JOB NO: MIN. 2 PER SIDE DWN BY: KKN STRUCTURAL STEEL ANGLE IRON AUXILLIARY DRAIN PAN TEF- 1 MOUNTING DETAIL W/ ANTIRUST PAINT AND HANGING PROVIDE 24V SWITCH WIRED TO SHUT N.T.S. ROD W/ TIE SPECIFIED TYPE OF DOWN UNIT IF WATER IS SENSED CHK BY: JML VIBRATION HANGER. Lagomasina A ssociates, P.A Consulting,��tn ers�i';'F,t,. ,,,�, REVISION AC -- SUSPENDED EQUIPMENT MOUNTING DETAIL N.T.S. CERTIFICATE O iAUfMORIVA91qN ICAL 2 OF 3 814 PONCE DE LE�PJ'BLrVD.' TEL.:(305) 444-0867 CORAL GABLES. Fl?"33t84T A T F44._-(305) 441-6979 SHEET o. 2 0'i I