Loading...
01-0483-010 ao op C� ao d o ¢ - o TYPICAL WATER HEATER DETAIL TYPICAL CONDENSATE DRAIN TRAP PLUMBING SYMBOL LEGEND GENERAL P-LU M BI N G NOTES: 4 PLUMBING FIXTURE SCHEDULE _ ^ ^^^ QQ SYMBOL DESCRIPTION o COLD WATER TO-,,,,,., PERFORATED CAP —�_ NO. DESCRIPTION DRAIN CW HW REMARKS 1• A. ALL WORK SHALL BE DONE in accordance with the South Florida w SYSTEM. f— SANITARY LINE ______________ ___ ___—___—___---------___---_---_ Building Code and with all applicable regulations. CLEAN OUT VENT LINE P-1 WATER CLOSET 4' 1/2" - A.S. #2292.100 B. DRAWINGS: Refer to all drawings for coordination of the U — — — -- plumbing work. cn COLD WATER SUPPLY (TANK TYPE, SEAT: OLSONITE #95, w 3/4 HEAT gp STORM DRAIN LINE C. ARRANGE AND PAY for all permits, licenses, inspections v ¢ TRAP DRAIN PAN —� -------FLR MTD)-------------------------------------------- � and tests. Obtain th@ req red certificc#es and present SAFEWASTE LINE � o SHUT-OFF VALVE " to owner, ,'y w 4% Qc = i C HOT WATER TO CD CONDENSATE LINE P-2 LAVATORY 1 1/4' 1/2 1/2" A.S. #0476.028, D. GUARANTEE: The completed instoll6tion 'sha be fully; < ' '•] 'i► SYSTEM. HEAT TRAP 18" MIN COUNTER TOP FAUCET:AS 2385.130 " -4 - COLD WATER LINE ( ) # guaranteed against defective mat4nols 'and' .� improper WATER SUPPLY PITCH DOWN P & T RELIEF —� TO HEATER. TOWARD DRAIN -- HOT WATER LINE workmanship for a minimum of one'year for amaterial and labor. VALVE. P & T RELIEF LINE HOT WATER RETURN E. ALL HORIZONTAL SANITARYtPIPING shall slope 6 1/8" per FT, FULL SIZE CLEAN OUT G GAS LINE ----------------------------------------------------- for pipes 3" and larger, and at 1/4" per FT for 2" and smaller. • P-3 LOUNGE SINK 1 1/2" 1/2" 1/2" JUST # SL-1815-A-GR FCO FLUSH CLEAN OUT (COUNTER TOP) FAUCET: CHICAGO ## 786-E29-255 2. SHOP DRAWINGS: Contractor shall submit for approval, within ELECTRIC WATER - - - FD FLOOR DRAIN 30 days of signing contract, a minimum of five copies of fully R D ROOF DRAIN ------------ - HEATER 2" MIN __________—__--_---_-----_—___—_-----_—___—_ descriptive literature, including but not limited to: water 6" MIN. P-4 SHOWER 2" 1/2" 1/2" A.S # 1662.601 heaters, and plumbing fixtures. No work shall proceed without Q� DRAIN VALVE RD-1 PVC ROOF DRAIN (BODY AND DOME) BASIN BY ARCHITECT. the approval of these submittals. DRAIN LINE SHALL BE AT LEAST THE CO CLEAN OUT FD FLOOR DRAIN 3" - - JOSAM ##30003-5A-50 3. PLUMBING FIXTURES: Fixtures shall be as specified and shall be Lij PLATFORM TO OUTSIDE, TERMINATE SAME SIZE AS THE NIPPLE ON THE VTR VENT THRU ROOF furnished and installed by this contractor. Fixtures shall be POINTING DOWN 6" DRAIN PAN RWL RAIN WATER LEADER complete with drains, traps, supplies and any other accessory Q ABOVE GRADE. RWL-1 CLAY PIPE RAIN WATER LEADER required. 4. MATERIALS: LL o NOTES: 1- A.S.= American Standard .Co 2- All exposed trim, such as P-traps, angle stops, and A. PIPING: O-I--J o supplies shall be chrome plated. . Soil, waste and vent, and storm: Cast Iron pipe & fittings. E METAL PAN WITH ALL 3" MIN pp p . SOLDERED SEAMS, 2" 3- All plumbing fixtures shall comply with table ## 46-R-2 of SFBC, Bell & Spigot for undergroundand No-Hub for above. (n M m $ CLEAR ALL AROUND b, Domestic water: Copper pipe, Type L with sweat wrought = •• o• HEATER. copper fittings. Type "M" in concealed spaces is U ? o ° � � 1" DRAIN, 1 2' acceptable. Isolate piping from concrete with Q ° RAISE PAN 1" ABOVE BOTTOM,OF � insulating material. c. Condensate drain: DWV Copper pipe and fittings. w LL PAN. TYPICAL C L E A N O U T DETAIL PIPE PENETRATION DETAIL d. Domestic water supply assembly: Chrome finish tubing c+, MAKER: LOCHINVAR with angle shut off valves. co MODEL: STJ030KK B. INSULATION: `D w CAPACITY: 30 GAL. 2 Hour Fire Rated Through a. Condensate drain: 3/4 in. thick, foam plastic W p o J Penetration Firestop for � insulation, fire resistant type. I- � , ELECTRICAL: 4.5 KW, 208V, 1 PHASE 4 4b ® ' Multiple Metal Pipe through 3735 Green Rd, a. Hot Water and Hot Water Return: 1" thick foam plastic :i w Concrete floors or walls Beachwood, OH, 44122 insulation, with self sealing flaps. O Z using FYRE-SHIELD. � FACE OF WALL Drawing not to scale 5. ALL AUTOMATIC ELECTRIC water heaters shall meet the O U (0 COVER SECURED CAJ1047 g standards of the latest energy efficiency code, ti F-ratin = 2 Hr. U Go WITH SCREWS ADJUSTABLE COLLAR T-rating = 0 Hr, 6, PIPING LEST AND DISINFEC110NS: � C326) A. Test: All sanitary and domestic water supply piping shall THREADED C.O. PLUG THREADED C,❑, PLUG be tested for leaks before piping is concealed or connected � 2 to equipment and plumbing fixtures, FIN, GRADE FIN, FLOOR I I STAINLESS STEEL COVER 1 B. Disinfection: All domestic water piping shall be w SCREWED TO THREADED ' ' disinfected by introducing a solution of calcium Q C.❑, PLUG, hypochlorite of 50 parts per million of chloride and as 7 �' per AWWA Standards. <� ;sit;:a `� :' ;'E'i;'3:i '• • •••• • • -••• � • • • • •• '•••• • 7. VALVES: Domestic water valves shall be of bronze body, U sweat ends. 4 X 6' DIA. CONCRETE 3B 8. All water connections to equipment shall be protected with vacuum PAD FLUSH W/FIN, GRADE 38 breakers as required by code. SLIP J❑INT 9. CONTRACTOR SHALL COORDINATE exact location of sanitary, 2 and water piping before starting any work. Notify Q Floor or Wall assembly = 4 ' thick concrete, Max. area of Architect/Engineer of any deviations from design drawings. Q) opening Is 288 sq, in, 10. CL EANOUTS: (-- -•I-� \ ® Nom, 8' diam. (or smaller) Sch, 40 (or heavier) steel pipe A. Wall: Josam 58890-15 V) t • Nom, 4' diaro, (or smaller) copper pipe. B. Finished Floor Josam 56020-88-15 Z Q Q Q • Max, number of pipes with opening is three (3). Q E EXTERI❑R TYPE FLOOR WALL ® A) Forming Material - (Not shown) - Nom, I' thick poly- 11. CONTRACTOR to fire protect and seal all openings and pipe urethane backer rod friction fitted penclratlons thru fire rated walls, floors and ceiling. Materials and —1 W _ Q into opening, methods to fire rating shall be approved by Dade County Product B) Nom. 1/e ' FYRE-SHIELD thickness Installed within opening. Control, 12. PROVIDE CEILING/WALL ACCESS DOORS where indicated on drawings � NOTE, For wall apply FYRE-SHIELD to both surfaces of wall, and when required to access mechanical equipment. Doors shall O z Y. -Q - The products used n the above as—bly have be recessed type, fire rated if in fire rated wall or ceilings. M Project, bee"tasted h accordance rtth the folloehgrhe above drscrbed assartly and ,r 9 O O W .:STM E014(1114791 Standard Test Method products have been tested and ore As manufactured by Karp model ROW and KATR. _ Lr _ o � for Through Pe,retrstlan FMestoppNp, based on both post and antklpoted .. Location- •ASTM E119 a1 esal Standard for Fire Tas-Wforl""M crltarIL Tranca shall 13. PLUMBING CONTRACTOR SHALL see structural drawings prior to l- l " of D Adlnp Eonetructlan and Materials, not be liable for ory danages,direct _ Installers or consequa rtlot.resultFg from use �^ Dote2/26/94 DrowingsTR-1047 �ate'y b;e; ;,m y';"for rep`oaro bidding to fully familiarize himself with project. U W Signatures Approved b Tuzzeo ^eterlal fauna to b wfectiva. Yc• 14, CONTRACTOR shall saw cut or core drill existing slabs to install new w 0 _ Q plumbing work. Patch slab to match existing. � J ease X � - W `w Z V' r z V-1 p >; LIJ W CL p uA O to a ° LV U _ o d Z O L? c 11 11 QL ,0 I i O 3 _. O 0 m } Co J C4 ;_,._... L p J m J (Y LU 1 ... ,... ... ... .-.. Z Z - t w LL Q U 3 V J ~ Q W H V ,u OC Z j ..... ... ._..... .. ... .. _. .... C, N ❑ ❑ V Lagom �j#I LM Associates, P.A Con pIt'+n.s r6 , "� r . DRAWING No . CERTI ICA'RE: Ogl 66,84 J 814 PONCE•,1DE • LE N BL TE .:(305) 444-0867 P —� CORAL GABLES; TF' .j 1-31 4 ' F,:A,X:005) 441.6979 _ SHEET 1 OF T E \`.