Loading...
01-0389-001 112,35' _ Hersh I Vitalini Electrical Cyr-a p h-k: Le end Corazzini PA RELOCATED - - ELECTRIC METER ARCHITECTURE PLANNING d :NEW DISCON. =--- = - INTERIORS {s A-9 LIGHT SWITCH 300 ARAGON AVENUE - SUITE 340 E A-1 . v1..Y .4� TEL:A305-A 5A 567-6021DA 4J cfl j D INDICATES DIMMER SWITCH _ r" c0D FLORIDA REGISTRATION AA C2194 ON 'ti'A-3 G A-11 I A-1 (m E DRYER � a: :., Closet _1 �f1' pp__ CEILING FAN WITH LIGHT AS ' E �J- WASHER INDICATED IN ELECTRICAL DRAWING A 16,18E A-1 Linen Sink Bedroom 2 Bath Kit hen O E WALL MOUNTED LIGHT FIXT. AS 00 & INDICATED IN ELEC, DRAWINGS A-3 E A-3 � GAI E 19 � A-1 t A-3 �TF Ref E SURFACE MOUNTED LIGHT Carport ELECTRICAL DRAWINGS IN E E Living Room A-1 A-24 A-13 � SD SMOKE DETECTOR SD SD A-24 E I `\� E -e 20A SINGLE RECEPTACLE `1' SideN,4 '- A/C I EWH ---J Cl (gEL -�l A-7 E� E INDICATES EXISTING 20A Cl �A-12 E Dining Room RECEPTACLE TO REMAIN 12f parkwQY 20,22 � SHADED AREA INDICATES 1/2 SWITCHED I � A-24 A-1 � A-13 ' 62 5D E E GFI GFI INDICATES GROUND FAULT - nd Court INTERRUPT - E Bedroom 1 A"5 A-1 +42'I NUMBER INDICATES MOUNTING HEIGHT OF DEVICE AFF, IF NO HEIGHT IS GIVEN A& � THAN MOUNT DEVICE AT 18" AFF A-5 E Porch 2 POLE SPECIAL USE / 220V c� OUTLET Electrical Notes Site Plan 20' A_5 ® ELECTRICAL PANEL "A" 1. General E A. All work performed under this contract shall comply with A-5 all national, state and local codes having jurisdiction and with, the requirements of the utility companies whose services shall be used. All modifications required by Electrical Plan 1/4" these codes shall be made by this contractor without additional charge. B. Drawins: Refer to all drawings for coordination of the electrical work. C. Arrange and pay for all permits, licenses, inspections and tesl•s. Obtain the required certificates and present to owner. D. Guarantee; The completed installation shall be fully guaranteed against defective materials and/or improper workmanshi Tor minimum of one year for material and labor, 2. Contractor is directed to review the building plans and specifications for limitations of constructions identifications of materials and products, definition of workmanship. This contractor shall include his bid proposal all costs necessary for a complete and operational Installation and shall visit the job site prior to a bid date. 3. Contractor needs to establish a field liason with project supervisor, prior to commencing work. 4. All required Insurance shall be provided for protection against public liability and property damage for duration of the work. 5. It shall not be the intent of these plans and/or specifica- tions to show every minor detail of construction. The electrical contractor shall be expected to furnish and install all items for a complete electrical system and provide all requirements necessary for equipment to be placed in proper working order. G. Electrical contractor shall not scale drawings. Contractor shall refer to architectural plans and elevations for exact TYPE G.E. MAIN BUS 150 A locations of all equipment unless otherwise noted. » » ` 7. All conduit runs are shown diagrammactically. Exact routing SERVICE 101 3W Panel A MAINS M.L.O. A shall be determined in the field, unless otherwise noted, 8. Electrical contractor shall visit the job site and verify all VOLTAGE 120/240 • conditions, locations, dimensions and counts as shown and/or A.I.C. ; 10,000 Residence noted on the drawings. This shall include any and all fabrications rior to Installations. K/VOLT CON REMARKS REMARKS ON CKT. CKT. K/VOLT p OVERHEAD SERVICE 9. As a minimum all equipment shall meet applicable standards, AMP POLE TRIP DUI WIR NO. N0. WIRE DUIT TRIF POLE AMP for the type of` equipment and intended use, of the following; FROM ELECTRICAL 6840 SW 63 Ct a. American National Standards Institute (ASTM). UTILITY COMPANY I 0,82 II ii b. Illuminating Engineers Society (IES). 1 15 1/2 #14 GEN. LTG./REC. 1 2 WASHER #12 1/2 20 1 1,50 C. American Society for Testing and Materials (ASTM) COORD. W/FP&L. 150A. DISCN. d. National Electrical Manufacturer's Association (NEMA). 120/240 1 PH. 3W I 0,.64 3 4 �i Note: These standards are subordinate to codes, and NEW ' ' 150 A. M.L.O.. DRYER #10 1/2 30 2 5.00 South Miami Floridc standards set by UL. 3#1 A.I.C.:101000 PANEL "A„ 0.64 5 6 10. All electrical equipment, devices, wire, ect. shall be NEMA 3R listed, for the intended use, with Underwriter CU , THW 120/240, 1 PH., 3W 0,36 7 8 laboratories, Inc. (UL), where standards have been IN 1 1/4"" C. A.I.C.:10 000 A/C C.U. #1 #10 1/2" 30 2 4.24 established by UL. ME ER CAN I 0.20 9 10 11, As-built drawings shall be furnished to the owner upon completion of work. 1.50 1 20 1/2" #12 SMALL APPLIANCE 11 12 12. Wiring devices to be spec. grade,is indicated at any location, I A/C AHU #1 #8 1/2" 30 2 5.00 13. Where more than one devices 200 1.50 1 SMALL APPLIANCE 13 14 Project No. 01000 these shall be ganged under one common cover plate. 1 PANEL 14. Contractor shall coordinate with electric and telephone O 200 REFRIGERATOR 15 16 utility for service entrance location and any other require- "All 1.20 ments. �` RANGE/OVEN #6 1" 50 2 12.00 15. All connections to ground rods shall be made with UL approved I SPARE 17 18 Distribution Date welded connections, unless noted otherwise. NEW 16. Provide a fuse holder and fuse in the primary side of each 3#1 19 20 PERMIT SET 4/(49/01 ungrounded conductor for all ballasts. WATER HEATER #10 1/2" 30 2 4.50 CU THW 17. Unless noted as existing, all equipment, wiring, devices, I I 21 22 etc, shall be new. IN 1 1/4" C. 18. Contractor shall guarantee all materials and workmanship free 23 24 SMOKE DET. & LIGHTS #14 1/2" 15 1 1.00 from defects for a period of not less than (1) year from date of acceptance, unless indicated of specified otherwise. 25 26 SPARE 19. Correction of any defects shall be completed without additional charge and shall include replacement or repair of #2 THW, CU. GROUND M,C,W,p, I 27 28 any other phase of the installation which may have been damaged thereby. 29 30 20. Electrical contractor shall provide temporary service for use of all trades as required for construction. 31 32 21. Temporary wiring to be removed by contractor. 22. Electrical contractor shall verify requirements, exact 33 34 location and type or outlet for all electrical fixtures, 6i_Qil appliances and equipment. 35 36 23. Shaow drawings: Coordinate with owner or architect. (MIN.) 24. All wiring to have 600 volt insulation, type TW, THW, THWN, 37 38 for branch circuits and type THW, THN for main feeders or as specified, 25, Design is based on copper conductor. Wire size #10 and 39 40 smaller type "TW", wire size #8 and larger type "THW" or 3/4"0x10'-O"L COOPER CLAD as specified. 6.76 TOTAL TOTA 33.24 26. Wire ways shall be sized as required, per NEC, unless GROUND RODS DRIVEN INTO GROUND otherwise noted. 27. All feeder, eubfeeder and branch circuits shall be properly TOTAL LOAD : 56,700 VA --- 167 AMPS. phase balanced. > DEMAND LOAD 26,397 VA --- 113 AMPS. 28. All conductors shall be in conduits. All conduits shall be LOAD CALCS.: A/C LOAD (100%) --- 5,000 VA intermediate (IMC) or rigid galvanized steel (RGS) except FEEDER: 3 # 1 CU,THW IN 1 1/4" C. �•`� A t!1 that; (a) poly vinyl chloride (PVC) conduits may used in lat. 10 KVA (100%) --- 10,000 VA !�! concrete slabs at underground provided elbows and riser are RGS; (b) electrical metallic tubing (EMT) may be used in or REST (40%) --- 11,996 VA on walls or ceilings where not subject to mechanical damage, damp conditions or corrosive conditions; (c) liquid tight = n • rj.' ' = flexible conduits where required; (d) flexible metallic •� -�- . I conduit where required in dry locations. All conduit v.1 ;a to hazardous areas (per NEC) shall meet the requirements of NEC Chapter. +C" r 29. Apply bitumastic coating to all metallic conduits in slabs •. �� or underground. �i� '. .•, Q = 1 30. Electrical contractor shall verify circuit protective device 'ri �t ••• rating for equipment prior to construction. 31. Provide fuse recommended by equipment manufacturer, 32. Furnish and install disconnect switches and wiring for air conditioning systems as per manufacturer recommendations. Controls are to be supplied by air conditioning contractor. d 33. Install power and control wiring and required control components for air condition systems as shown/noted on r these drawings and per other applicable drawings/instruc- b tions see A/C drawin s. Ao 34. Electrical contractor to run control wires for HVAC system as per HVAC drawings. 35. No conduits to be run in ductwork. 36. All electrical wiring must be in conduit (no Romex, BX, etc. is permitted unless specific permission is obtained from owner, engineering or local inspector).