01-0340-010
OWNER CONTACT INFORMATION: - -= _ -- MR. NAT KLE-l'NMX,-\l,.GENERAL ELECTRICAL NOTES --- - -- 6701 cor.loo�11��1ur�__ -I ° a CIRCUIT TO ADJACENT 6701 SUNSET DRIVE, SUITE 104 W FL � 1- ALL ELECTRICAL WORK PERFORMED IN THIS CONTRACT SHALL COMPLY _ - - M POLES ARE To SOUTH MIAMI, FLORIDA 33143 —� o 7 THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE Be BE MAINTAINED OPERATIONAL WITH THE NEC, LOCAL LAWS AND ORDINANCES, THE RULES AND - AT ALL TIMES C3os� 662_-2272 REGULATIONS OF THE LOCAL UTILITY COMPANIES, AND ALL HIS _WORK WI►H-_THAT OF OTHER TRADES AND/OR GENERAL CONTRACTOR. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS STANDARDS OF CONSTRUCTION ESTABLISHED BY THE LANDLORD. WHICH ARE NECESSARY TO COMPLETE THE INSTALLATION OF A j Q COMPLETE AND WORKING ELECTRICAL SYSTEM INDICATED BY CONTRACT 2- EXCEPT AS OTHERWISE INDICATED, ALL CONDUCTORS SHALL BE DRAWINGS. ELECTRICAL CONTRACTOR SHALL SECURE A COMPLETE SET �[ � - COPPER. USE THHN SOLID WIRES FOR CONDUCTORS SIZES No. 10 OF DRAWINGS PRIOR TO BID TO DETERMINE IF OTHER WORK INDICATED SMALLER. USE TYPE THWN STRAINED CABLE FOR CONDUCTORS IN IN STRUCTURAL, ARCHITECTURAL, MECHANICAL, OR OTHER T REINFORCED U r I SIZES No 8 AND LARGER. CABLE SIZES # 3/0 AND LARGER SHALL DISCIPLINE, WILL AFFECT HIS BID. CONTRACTOR IS TO THE VISIT CONCRETE ROOF SLAB Q 43 TERMINATE WITH PRESSURE CRIMP CONNECTORS. ALL CIRCUITS SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS WHICH DO NOT SHOW WIRING AND CONDUIT SIZE ARE TO BE # 12 CU. PRIOR TO BID. NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN IN 1/2" CONDUIT. THESE DRAWINGS AND THE EXISTING INSTALLATION. Q LL 3- ROUTING OF RACEWAYS, INTERCONNECTING OUTLETS AND HOME-RUNS 8- IN EXISTING BUILDINGS, ALL ROOF AND SLAB PENETRATIONS MUST co co IS UP TO ELECTRICAL CONTRACTOR, BUT AFTER COMPLETION OF THE INSTALLATION, HE SHALL SUBMIT TO THE ENGINEER AS BUILT CONFORM TO LANDLORD'S STANDARD CRITERIA AND SHALL BE SUBJECT TO LANDLORD'S APPROVAL AS TO LOCATION ..AND CONSTRUCTION I DRAWINGS OF HIS WORK FOR FUTURE RECORD. ALL CONDUCTORS DETAILS. ROOFING AND/OR WEATHERPROOFING OF ANY INSTALLATION REMOVE EXISTING 1 SHALL BE IN CONDUIT. FOR UNDERGROUND/IN-SLAB LOCATIONS USE AND/OR PENETRATION MUST BE PERFORMED BY A ROOFING CONTRACTOR ' LIGHT POLE GALVANIZED RIGID STEEL GRS CONDUIT OR SCHEDULE 40 PVC (REUSE CIRCUIT ( ) AUTHORIZED BY THE LANDLORD. CONTRACTOR IS REQUIRED TO FOR NEW LIGHTS CONDUIT WITH GROUND WIRE SIZED AS INDICATED OR REQUIRED BY MAINTAIN FIRE RATING OF ALL WALL AND SLAB PENETRATIONS. UNDER ROOF) ! I NEC. UNDERGROUND GRS SHALL BE COATED WITH TWO COATS OF / BITUMASTIC # 50 APPLIED WITHOUT THINING. ALL SECTIONS OF g- ELECTRICAL CONTRACTOR IS TO COORDINATE HIS WORK WITH THE \ METALLIC CONDUIT SYSTEM SHALL BE GROUNDED AND ELECTRICALLY ARCHITECT, TENANT, OR OWNER, AS APPLICABLE, BEFORE ROUGH SEE DETAILED CONTINOUS. USE ELECTRICAL METALLIC TUBING (EMT) FOR INSTALLATION OF LIGHTS, RECEPTACLES, AND SWITCHES FOR EXACT NOTES BELOW) W.P. x•\- INTERIOR CONCEALED WIRING AND ELSEWHERE AS PERMITED BY THE LOCATION AND HEIGHT. CONTRACTOR SHALL VERIFY THE CEILING NEC. USE FLEXIBLE METAL CONDUIT FOR CONNECTIONS TO LIGHT FINISHES AND SUSPENSION SYSTEMS FOR SELECTION OF THE PROPER FIXTURES AND TRANSFORMERS. USE LIQUID TIGHT FOR FLEXIBLE TRIM AND SUPPORT ARRANGMENTS OF THE FIXTURE. COORDINATE CONNECTIONS IN ALL WET LOCATIONS. INSTALL A NYLON PULL REQUIREMENTS PRIOR TO BID. CHORD IN ALL EMPTY RACE WAYS FOR FUTURE USE. SIZE ALL GUTTERS AND PULL BOXES PER NEC 370 AND 374. 10- ELECTRICAL CONTRACTOR SHALL COORDINATE THE REQUIREMENTS OF a 4- FUSES SERVING ELECTRICAL MOTORS SHALL BE TIME DELAYED TYPE, PLUG AND CHORD TYPE EQUIPMENT WITH MANUFACTURER AND IS UNLESS OTHERWISE INDICATED. ALL MOTERS STARTERS ARE TO BE REQUIRED TO PROVIDE ELECTRICAL OUTLETS THAT WILL ACCEPT oC SUPPLIED AND INSTALLED. GENERAL CONTRACTOR IS REQUIRED TO MANUFACTURER'S SUPPLIED PLUGS. O 1 LL COORDINATE WITH ELECTRICAL AND MECHANICAL SUBCONTRACTORS 11 - ALL AREAS IN WHICH WORK IS BEING PERFORMED SHALL BE KEPT 0, PRIOR TO BID. CLEAN AT ALL TIMES. \, CONC. BEAMS 5- ALL WIRING DEVICES SHALL BE SPECIFICATION GRADE HUBBELL OR \ ? 12- EQUIPMENT SPECIFIED SHALL BE ADHERED TO. HOWEVER, OWNER HAS APPROVED EQUAL. WIRING DEVICE PLATES IN FINISHED AREAS THE FINAL DECISION ON THE TYPE AND QUALITY OF EQUIPMENT TO BE w SHALL BE PHENOLIC COMPOUND WITH POLISH FINISH. COLOR ANS SUPLLIED. CONTRACTOR SHALL OBTAIN WRITTEN PERMISSION FROM oC STYLE SELECTED BY ARCHITECT, TENANT, OR OWNER, AS THE OWNER PRIOR TO PURCHASING SUBSTITUTING EQUIPMENT. - APPLICABLE. ALL SWITHCHES MOUNTED VERTICALLLY 048" A.F.F. CONTRACTOR SHALL BEAR THE COST OF ALL ENGINEERING WORK UNLESS OTHERWISE SPECIFIED. ALL RECEPTACLES MOUNTED RELATED TO SUBSTITUDED EQUIPMENT. O VERTICALLY 018 A.F.F. UNLESS OTHERWISE SPECIFIED. WHERE (SUBMIT SHOP DWGS./CUT SHEETS OF FIXTURES FOR APPROVAL.) 122'-0" N APPLICABLE, OUTLETS (POWER, TELEPHONE, DATA, SECUTRITY, ETC. WITHIN CASEWORK ARE TO BE COORDINATED WITH CASEWORK N I � N MANUFACTURER. IN THE CASE OF OUTLETS SERVING CASEWORK MOUNTED EQUIPMENT, COORDINATE WITH CASEWORK MANUFACTURER AND 13- PROVIDE CONDUIT WITH PULL-STRINGS. w EQUIPMENT MANUFACTURER FOR EXACT REQUIREMENTS PRIOR TO BID. COORDINATE INSTALLATION OF FLOOR OUTLETS WITH OWNER OR TENANT FOR EXACT LOCATION. IF FLOOR OUTLETS SERVE DISPLAY • a FIXTURES COORDINATE WITH MANUFACTURER FOR EXACT NEW I'X4' (2-TUBE) DAMP PROOF „Y LOCATION REQUIRED. LOCATIONS ON THESE DRAWINGS ARE SURFACE MOUNTED LIGHT FIXTURES WITH ACRYLIC LENS, WHITE HOUSING p[ ALL TO MATCH EXISTING a- j-' m m a- f 6- PROVIDE WRITTEN GUARANTEE STATING THAT THE CONDUCTOR WILL (TYPICAL) co APPROXIMATE. #12 THWN COPPER WIRE % oz REPLACE OR REPAIR, FREE OF CHARGE, ANY EQUIPMENT OR MATERIAL IN I/2" CONDUIT j z 3 > ~ WHICH FAILS DURING A ONE YEAR PERIOD FROM THE DATE OF (TYPICAL) m OL p SUBSTANTIAL COMPLETION. c � Q 1 s 1 CONCRETE INSTALL NEW WATER PROOF COLUMNS J--BOX W/UNDERGOUNO \ (V CONDUIT TO NEAREST \1 N CONC. COLUMN � INSTALL RECESSED J-BOX ALL CONDUIT SHALL BE CONCEALED AT EACH LIGHT I COORDINATE WITH GEN. CONTRACTOR �. PLACEMENT OF CONDUIT & J-BOXES PRIOR TO POURING CONCRETE (TYPICAL) - i REMOVE EXISTING W.P. `J LIGHT POLE _I (REUSE CIRCUIT i 'q- FOR NEW LIGHTS p c� UNDER ROOF) w RUN CONDUIT UNDERGROUND �� Z TO CONC. COLUMN A � 0 a � Z W w U (n ~ w O E-4 MM Oa 0 W r4 0 Q; /a. LIGHTING PLAN er ; 0 1 2 J 4 3 6 7 0 9 p h p p M lS G 17 6 Fi 20 FEE1 �\CO • ��•• ��©'•,• '�_' 4_4 old SHEET q OF q