Loading...
01-0177-007 AL-FAROOQ CORPORATION 1235 S.W. 87th. AVENUE MIAMI, FL. 33174 PH. 305-264-8100 AFC JOB #:AFC 01-088 02-16-2001 CUSTOMER :AUTOMATED HOME SERVICES PROJECT :MARK RESD. ADDRESS :8225 SW 60 CT. CITY :SOUTH MIAMI WIND LOAD ANALYSIS FOR COMPONENTS AND CLADDING AS PER SPECIFICATION ASCE7-88 & ASCE 7-93 FOR BUILDINGS 60 FT. HIGH OR LESS BASIC WIND SPEED V : 110 MPH '_MF'ORTn1VCE: FACTOR I : 1.05 EXPOSURE C.%TEGORY : C MELN ROOF ELEVATION H : 20 FT. - - L ROOF SLOPE GREATER THAN 10 DEG. /B TRIBUTARY LOAD AREA A 108 FTC2 Kz = . 87 (TABLE 6, p12) VELOCITY Pi.ZESSURE Qh= .00256 Kz (IV) "'2 = 29 .71 rCp CO'R3F FICIENTS (FIGURE 3, p17) --- - - - ZONE 4 = +1.16 -1.26 = ZONE 5 = +1 .16 -1.45 = GLAZING TYPE OR SIMILAR GCPi COEFFICIENT (+ -)- - .25- - - ALL CASES DESIGN PRESSURE P = Qh(GCp - GCpi) (TABLE 6, p10) ZONE 4 = + 41.8 PSF - 44 .8 PSF ZONE 5 = + 41. 8 PSF - 50 . 6 PSF 6 OuA)71V �,eal�aC WIDE G,�t2�a� L ,e iS �!'��o�� /1 �- �'.S•0 1�sF �l° o K// 5-°• �F/ UNs�Q Ps F o K// ' n 1