01-0106-024
REVISIONS BY ELECTRICAL SCHEDULE CIRCUIT DESCRIPTION BREAKER BRANCH CIRCUIT LOAD ENTRY TRIP POLE (EXISTING) 1 WASHER 20 1 2 * 12 THW IN 1/2" C 1.5 KW 2 REFRIGERATOR 20 1 2 * 12 THW IN 1/2" C 1.5 i 3 DISHWASHER 20 1 2 012 THW IN I/2" C 12 CSI=N1=iZ4L L IGHtING ]BEDROOM 4,6 WATER HEATER 30 2 3 * 10 THW IN 3/4" C 4.5 (EXISTING) O 51 DRYER 30 2 3 * 10 THW IN 3/4" C 5.0 1549.00 SQFT. X 3 W/SQ.FT, = 4.1 KW 8110 RANGE 50 2 3 # 6 THW IN I C 12.0 CALCULATIONS 9,11 A/C UNIT/COND. UNIT 50 2 3 S THW IN 3/4 C 45 LIVING A/C 6 100% 10 KW (EXISTING) J 12,14 A/C AIR HANDLER 60 2 3 * & THW IN I" C 91ro FIRST 10 KW 'a 100°1. 10 KW a . LL- 13,15 SMALL APPLIANCES 20 1 2 * 12 THW IN 1/2" C 3.0 REMAIN a 40i. 108 KW. • N 16-25 GENERAL LIGHTING 15 1 2 014 THW IN 1/2" C 41 3015K.W. 26 GFI (BATHROOM) 20 1 2 * 12 THW IN 1/2" C O 30B KW (1000) W = 9 AMPS O 12 240 CL O u 21 NEW BATHROOM 20 1 2 012 THW IN 1/2" C Ld 28 NEW BEDROOM 15 1 2 014 THW IN 1/2" C PROVIDE 150 AMP PANEL EXISTING Li ELEC. PANEL _ 29 SPARE AC L J } � � Z NE E Flo 9 LI Z 0 LLJ EXISTING HOUSE ARE 1,240. + AD ITION 309. SF = 1,549. 00 SF 4-1.5 KW 5EDROOM 0 Z (EXISTING) 0 CFM DINING KITCHEN 00 W 0 lf) ALREADY INCLUDED IN GENERAL LIGHTING. (EXISTING) (EXISTING) r) Z 0 © 0 0) Li.l Q � n 5 _ I CY D d0' ELEGO. METER O i AND MAIN CKT. BRKR LOCATION 11-T3 NEC 4108 p J O c-I I Q Q" th .O w CL` I / (EXISTING) .,,,;• �-t � 1 / f•� �_ r MASTER SEC?POOM i WH D c-I UTILITY (E�ISTING) - - OW • ELECTRICAL LEGEND �-' DUPLEX OUTLET HALF CONNECTS TO SWITCH DUPLEX RECEPTACLE ELECTRICAL NOTE: C GROUND FAULT INTERUPTER NEW C-1 AND C-2 CIRCUITS WIRED TO EXISTING SPARE BREAKERS IN PANEL SERVICE ADEQUATE TO HANDLE NEW LOADS. s ® SPECIAL PURPOSE OUTLET INCANDESCENT LIGHT FIXTURE, CEILING MOUNTED '" 7 Q INCANDESCENT LIGHT FIXTURE WA LL ED iV MOUNT ELECTRICAL PLAr ELECTRICAL NOTES $ SINGLE POLE SWITCH SCALE: 1/4" = 1'-0" 1.- ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW BASE 4 FLOOD ELEVATION SHALL BE INSTALLED AT THE HIGHEST 3 PERMITTED 1 s s+ s -WAY SWITCH ELEVATION AND SHALL BE INSTALLED ON (SEPARATE) INDEPENDENT CIRCUIT FROM THOSE IN THE HABITUAL AREAS. F t L FAN AND LIGHT SWITCH s R *,"M x 2.- NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE INSTALLED ++ ,�.; Q "• d TELEPHONE OUTLET 9EQbIQOD ELEVATION. sag ri O SD SMOKE DETECTOR 3.- A/C COMPRESSORS SHALL BE INSTALLED ABOVE BASE FLOOD a H µ y a" MOTOR 4.- MAIN CIRCUIT BREAKER PANELS SHALL BE LOCATED ABOVE BASE `"`' r=;:� ��2-;� `� ,. =•�� .'t, � 001 � FLOOD ELEVATION. '4 O fA ELECTRICAL PANEL V, 5.- ELECTRICAL METER SHALL BE LOCATED TO COMPLY WITH FEDERAL EMERGENCY MANAGEMENT AGENCY REQUIREMENTS. ' __. ro �.., , ❑T THERMOSTAT ' <" .- CONDITIONS FOR INSTALLATION OF LIGHTING FIXTURES IN CLOTHES k h� - *. r Dr d' FAN CLOSETS SHALL COMPLY WITH SEC. 410-8 OF NEC. Q 1. DENOTES LOCATION OF SMOKE DETECTORS WITH BATTERY BACKUP � f?'. -� * � Y� z � O NOTE: Connect smoke detector to non-swftchable bathroom ` z TO BE CONNECTED TO A NON SWITCHABLE BATHROOM LIGHT CIRCUIT. DO NOT CONNECT TO LOAD SIDE OF GFI CIRCUIT. Ya 4 ? .. 34 a �. �„y r• *� 3 ate 0025-01 >' Scale 4S NOTED �( �rawn G.D.J. A b 00-320 ` t - Sheet Of 8 Sheets