01-0106-022 I REVISIONS BY 1- 05/21/01 G 3- 08109101 Gi ELECTRICAL SCHEDULE CIRCUIT DESCRIPTION BREAKER TRIP POLE BRANCH CIRCUIT LOAD ENTRY (EXISTING) 1 REFRIGERATOR 20 1 2 +' 12 THW IN 1/2" C 1.5 3 DISHWASHER 20 1 2 012 THW IN 1/2" C 1.5 2,4 A/C UNIT/COND. UNIT 50 2 3 " 8 THW IN 3/4" C 4.5 ������� LIGHT I I�l� ��D}�OOM 5,l A/C AIR HANDLER 60 2 3 " 6 THW IN 1" C 9.6 (EXISTING) 60 SMALL APPLIANCES 20 1 2 012 THW IN 1/2" C 4.5 1549.00 FT, X 3 W/SOFT. = 4.1 KW O 0 9,16 GENERAL LIGHTING 15 1 2 " 14 THW IN In" C 4.7 CALCULATIONS � 19 CFI (BATHROOM) 20 1 2 012 THW IN 112" C (_) LIVING A/C a 10095 10 KW (EXISTING) 20,21 NEW ADDITION 20 1 2 012 THW IN 112" C (_) FIRST 10 KW a 10095 10 KW 22 SPARE REMAIN tv 40% 2.52 KW — 23 KW N Q 23 KW (1000) 100 AMPS LJ :2 O 230 n- O C/ PANEL PROVIDED = 150 AMPS EXISTING W Ld ELEC. PANEL LLf (n AG LL o D � Z Z° EXISTING HOUSE ARE 1,240. F + AD ITION 309. Sr- = 1,549. 00 SF 263 KW 5EDR00M ° ° : Z : (ExlsttNCx) 0 D Ii�111�C KITCHEN p Q o Z ., d- C=) ALREADY INCLUDED IN GENERAL LICzHtfNCs. o (EXISTING) (EXISTING) 0 00 N 1 Ld JZ0) D Q cn I 1 Or r - O RELOCATED Q U ELEC. METER AND MAIN CKT. -21 Z Z BRKR LOCATION -1 O Lo C-p1 NEC 4105 � � � C-20 G21 W ry — O FAMILY U N IZ (EXISTING) C-20 C-20 MASTER 5E OOM CA C-2m C-20 UTILITY , `? (EXISTING) OW ELECTRICAL LEGEND c-20 c-2m DUPLEX OUTLET HALE CONNECTS TO sWITCH DUPLEX RECEPTACLE EL CT (CAL MOTE: 3 am GROUND FAULT INTERUPT'ER NEW C-19, C-20 D C-21 I UITS WIRED TO EXISTING SPARE BREAKERS IN ® SPECIAL PURPOSE OUTLET PANEL SERVICE DEQU t HANDLE NEW LOADS. 1 INCANDESCENT LIGHT FIXTURE, CEILING mouNTEr, Q Q INCANDESCENT LIGHT FIXTURE, WALL MOUNTED ELECTRICAL PLAN W ELECTRICAL NOTES � $ SINGLE POLE SWITCH SCALE: 1/4" = V-0" W I.- ELECTRICAL OUTLETS (RECEPTACLES AND LIGHTING) BELOW BASE $-s 3-WAY SWITCH FLOOD ELEVATION SHALL BE INSTALLED AT THE HIGHEST PEFNITTED ELEVATION AND SHALL BE INSTALLED ON (SEPARATE) INDEPENDENT Li $P 4 XAN AND LIGHT SWITCH CIRCUIT FROM THOSE IN THE HABITUAL AREAS. - •_ 2: NO APPLIANCES OR APPLIANCE OUTLETS SHALL BE INSTALLED a E BELOW FLOOD ELEVATION. o •D Q TELEPHONE OUTLET I � SD SMOKE DETECTOR 3.- A/C COMPRESSORS SHALL BE INSTALLED ABOVE BASE FLOOD LL U. � MOTOR 4: z MAIN CIRCUIT BREAKER PANELS SHALL BE LOCATED ABOVE BASE � FLOOD ELEVATION. 00 O �^ -+-� 00 ELECTRICAL PANEL v, 5.- ELECTRICAL METER SHALL BE LOCATED TO COMPLY WITH FEDERAL (n V) 00❑t THERMOSTAT EMERIC�sENCY MANAGEMENT AGENCY REG2UIREMENtS. Q Cn 6: CONDITIONS FOR INSTALLATION OF LIGHTING FIXTURES IN CLOTHES Q 0 Fm CLOSETS SHALL COMPLY WITH SEC. 410-8 OF NEC. d- 'I. DENOTES LOCATION OF SMOKE DETECTORS WITH BATTERY BACKUP Q Z O NOTE: Connect amokms detector to non-swttchable bathroom t0 BE CONNECTED t0 A NON SWITCHABLE BATHROOM LIGHT CIRCUIT. (n ) OT CONNECT TO LOAD SIDE OF GFI CIRCUIT. S. GF.I. RECEPTACLE TO BE INDIVIDUAL CIRCUIT 012 AWG - 20 AMP 1 W 000 IN BATHROOM. NO OTHER WIRING TO THIS RECEPTACLE. � n Date 01-29-01 Scale AS NOTED Drawn C.D.J. Job 00-320 Sheet E-1 Of 8 Sheets i I