Loading...
01-0106-021 REVISIONS BY ENTRY (EXISTING) A . C . GENERAL NOTES . A/C EQUIPMENT SCHEDULE - 1. THE WORK THAT IS TO BE DONE UNDER THIS HEADINGS INCLUDES THE UNIT NUMBER EXIXTING AHU-I 5EDR00M FURNISHING OF ALL LABOR, MATERIALS, EQUIPMENT, PERMITS, FEES AREA SERVED SEE FLOOR PLAN (EXISTING) INSPECTIONS, TESTS, INSURANCE, ETC. REQUIRED FOR THE Z TOTAL SUPPLY AIR CFM 1400 O COMPLETION OF THE AIR CONDITIONING SYSTEM SHOWN ON THE 0 DRAWINGS AND/ OR LISTED BELOW. '� OUTSIDE AIR CFM - �— LL EXTERNAL STATIC PRESS. LIVING H2O 0.5 (EXISTING) � 2. VENTILATION DUCTWORK SHALL BE GALVANIZED STEEL WITH GAUGES, DUCT CONSTRUCTION, BRACING AND SUSPENSION IN ACCORDANCE WITH FAN MOTOR HP/FLA 1/3 /2.8 THE RECOMMENDATIONS SET FORTH IN THE LATEST EDITION OF THE LL ELEC. CHAR �i/dN 2m8/23m/1/gym N A.S.H.R.A.E. GUIDE AND SM.A.CN.A. STANDARDS. DUCT SIZES SHOWN --t COOL. COIL GAP. BtU/HR 41000 ARE "INSIDE" DIMENSIONS. VERIFY EXACT LOCATION OF DUCT WITH a � RESPECT TO STRUCTURE BEFORE FABRICATION. TOTAL SENS. HEAT BTU/HR 29200 _ / CV4 Q ENT. AIR TEMP. OF DB/OF WB 80/67 V LLJ O 3. FLEXIBLE DUCT SHALL BE STEEL HELIX WIRE ON 7/8" CENTERS, U TO AHU CL O ENCAPSULATED IN A CONTINUOUS SOFT VINYL FILM, JOINED BY MOLECULAR U MODEL NUMBER CFM RCBA-4515 w WELDING TO FORM AN AIR TIGHT INNER CORE, THE CORE IS TO BE UNIT MANUFACTURER RHEEM JF _l INSULATED WITH FIBERGLASS INSULATION (R-6), AND SHEATHED IN A V) � MODEL NUMBER RBEA-21 — REINFORCED, ALUMINUM METALIZED POLYESTER VAPOR BARRIER JACKET. PROVIDE SPIN COLLAR WITH DAMPER AND EXTRACTOR WHERE FLEXIBLE WEIGHT LBS. 150 NE 8 x 8 S/A El. L DUCT CONN. TO Z DUCT IS CONNECTED TO RECTANGULAR DUCTWORK DAMPER ACTUATOR REMARKS: REF. PIPING RS/RL 1-1/8 /3/8 BEDROOM NEW EXIST. S/A PLENUM E° LW Z SHALL BE EXTENDED OUTSIDE INSULATION. (EXISTING) DINING D UNIT NUMBER EXISTING CU-1 (EXISTING) KITCHEN 00 - z cn LOCATION SEE FLOOR PLAN 50 (EXISTING) Ld 0 4. RIR6 ONDIFIIBERGLA S U.L. 181 LISTED, DUCTWORK SHALL DUCT. BE 1-1/2" AMBIENT TEMP. F 95 8" x all O O z DUCTWORK SHALL BE FABRICATED IN ACCORDANCE WITH SM.A.CN.A. la1 REFRIGERANT R 22 N J M STANDARDS. OR-6 70P LEVEL, R-42 IN OCHER LEVELS). -2 :D Q 0 COMPJCOND. FAN FLA 18.0 / 2.0 — — — 0 — O ELEC. CHAR V/ /� 16 . 208/230// 0 — — — N 5. TEMPERATURE CONTROL SHALL BE A ROOM THERMOSTAT FOR II LU ? U o O HEATING/COOLING WITH STAGES AS REQUIRED. MANUFACTURER RHEEM � z 0 MODEL NUMBER RAMA-042 - - - I O 0 O 6"� � WEIGHT LBS. 220 � I i 0—'• C/) .Q, 6. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID 'Q REMARKS SEER/NOTES 11.9 I KW 'a` �� I INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION AND IN STRICT 056X 60 CFM FAMILY UNIT MTD. ELEC. HEAT CAP. KW 10.0 W COMPLIANCE WITH ALL APPLICABLE CODES AND STANDARDS. 2 6"� (EXISTING) :U-�� Cpl 0_ STEPS OF ELEC. HEAT NO. 1 6X 6Cp _ r. 50 CFM 1. MECHANICAL CONTRACTOR SHALL VERIFY DIRECTION OF EXISTING LLi - = ELEC. CHAR V/�/�. 230/1/60 O STRUCTURE BEFORE INSTALLATION OF EQUIPMENTS AND DUCTWORK O = SHOULD ANY DISCREPANCIES BE FOUND CONTACT ARCHITECT/ENGINEER FMODELNUM15ER - MASTER BEDROOM 1 - 8. VIBRATION ISOLATION: ALL EQUIPMENT AS PER MANUFACTURER ........ RECOMMENDATIONS TO ELIMINATE ANY EQUIPMENT NOISE FROM BEING 12X &CDC D HEARD. ® I-f5 CFM ` WH FAN SCHEDULE J 9. GUARANTEES: UTILITY A. ALL COMPRESSOR MOTORS ON NEW EQUIPMENT FURNISHED UNDER UNIT NUMBER EF-1 (EXISTING) THIS CONTRACT SHALL HAVE A 5 YEARS PRODUCT GUARANTEE FROM AREA SERVED TOILET RI"IS. W DATE OF START-UP. LOCATION CEILING ■ DUTY SUPPLY/EXH. EXH. B. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FAN TYPE CEILING FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN A 1 YEAR FROM DATE OF ACCEPTANCE. DRIVE BELT/DIRECT DIRECT FAN SPEED RPM 10'10 10. TESTING: AIR QUANTITY CFM 100 A. ALL REFRIGERANT HIGH SIDE PIPING TO 300 PSIG. LOW SIDE TOTAL STATIC PRESS. H2 0.25 TO 150 PSIG. AFTER TESTING, EVACUATE SYSTEM TO 2a% OPENING REQUIRED IN. - AIR CONDITIONING PLAN MERCURY GAUGE PRESSURE WITH VACUUM PUMP. HOLE) FOR 25 FAN MOTOR HP 60 WATTS HOURS WITH PUMP OFF. BREAK VACUUM WITH REFRIGERANT. ELECTRICAL CHAR V/O/- 11511160 SCALE: 1/4" = 1'-0" B. BALANCE AIR SYSTEM TO DELIVER QUANTITIES AT EACH OUTLET MANUFACTURER LOREN COOK W n WITHIN 5% USING A.A.B.C. PROCEDURES AND TESTS. SUBMIT MODEL NUMBER GEM-II AIR BALANCE TEST RESULTS FOR APPROVAL PRIOR TO FINAL WEIGHT LBS. 25 f INSPECTION. REMARKS SONES 42 NOTE: EF-1 SHALL BE INTERLOCKED WITH LIGHT 11. REFRIGERATION SUCTION PIPING SHALL BE INSULATED WITH 3/4" IN- FIXTURE UNIT. = COAFLEX. ARMAFLEX INSULATION MAY ONLY BE USED IN NON-PLENUM •E EGEND Q LL AREAS. FINISHED WHERE EXPOSED WITH 2 GOATS OF WHITE LATEX PAINT AIR DISTRIBUTION SCHEDULE U. � ALL A PER MANUFACTURER'S INSTRUCTION. SYMBOL NECK SIZE MFGR, MODEL NUMBER REMARKS E.F. EXHAUST FAN � N z 12. ALL REFRIGERANT PIPING SHALL BE TYPE "K" HARD COPPER, TOGETHER ® 5EE FLR PLAN TITLZ CLG.DIFFUSER SERIES 250 R/A CSR (D 00 WITH WROUGHT COPPER SOLDER FITTINGS. JOINTS SHALL BE MADE WITH HVAC DESIGN REQUIRES YES NO® O 4_j SILVER SOLDER O "SI FOS". A LL CON DEN S ATE DRAIN PIPING TO BE DUCT SMOKE DETECTOR CEILING DIFFUSER ® � � 4� 00 SCHEDULE 40 TYPE II HIGH IMPACT PVC WITH SLIP JOINT FITTING OF © FIRE DAMPER CS) � ✓ Q THE SAME MATERIALS WITH AN APPROVED SOLVENT INSTALLED IN A N❑TES d- ; SMOKE DAMPER (S) ✓ FLEXIBLE DUCT MANNER RECOMMENDED BY THE FITTING MANUFACTURER 1, REFER TO PLAN FOR QUANTITY, LOCATION AIR THR❑W FIRE RATED ENCLOSURE 0000 0O PATTERN AND SIZES, FIRE REATED ROOF / FLOOR ✓ Q cf) � CEILING ASSEMBLY 0 RIGID DUCT Z. ALL AIR DISTRIBUTION DEVICES SHALL BE OF EXTRUDED 0 ALUMINUM C❑NSTRUCTI❑N, FURNISH WITH OPPOSED FIRE STOPPING oI 0 THERMOSTAT W � 0 - BLADE DAMPERS AND CONCEALED MOUNTING FRAME z Ln FOR ACOUSTICAL OR PLASTER CEILING INSTALLATI❑N, SMOKE CONTROL Date 01-29-01 Scale AS NOTED Drawn G.D.J. Job 00-320 Sheet AC-1 Of 8 Sheets