01-0106-010 REVISIONS BY
1- 05/21/01 GJ
F'RCMDE WINDOW 24 SH ENTRY
a MASTER W/O STOP (EXISTING)
N
20" L BEDROOM
(Ex1st1NG�
SECOND MEANS OF ESCAPE WINDOWS CD
EGRESS WINDOW AS SECOND MEANS OF ESCAPE TO
VE AN OUTSIDE WINDOW OR DOOR OPERABLE FROM LIVING
THE INSIDE WITHOUT THE USE OF TOOLS*0 PROVIDING (EXISTING) rr)
A CLEAR OPENING OF NOT LESS THAN 20 X M WIDTH, J
24 X IN HEIGHT AND 5.1 WFT. M AREA 2 W
CV
LEGEND w
. O
TO AHU 0- O
NEW 8"CM WALL BLOCK (EXISTING)
W
AG W (n
EXISTING WALL TO REMAIN _j a —
W
® NEW CONC.COLUMN lu O o � z
g.NEW INTERIOR WALL W/6708 AT � � BEDROOM EO � W �
24'MAX.AND 1/!"GYP WALL BOARD � LOCATED (EXISTING) DINING 00
I z (n
EA`SIDE,PROYfDE BATT INSLL IN CAVITY z (EXISTINGS) W O
N
ACCESS WINDOW 00 p Z p
\T
W z �
w w
DOOR SCHEDULE Q n
�_
TEMP. c-�L ASS I
SIZE c�
NO. DESCRIPTION WIDTH HEIGHT THICK MATERIAL BUTT. FINISH THRESHOLD FRAME REMARKS cAT. II Q U U
I---
1 SINGLE ACTING: 2'-8" 6'-8" 13/8', PLYWOOD 2 PAINTED WOOD FREWLM/* TC °
2 -FOLD 3'-0" 61-8" 13/8,1 PLYWOOD - PAINTED PLUSH/ALUM. WOOD FULL LoUvm;mD -' 8 S 2�r �'� ��r-Or'� 1 O
S-24: 24'x12"CONC FOOTING O Ln
N W/3 S CONT. p F-
3 SINGLE ACTING 2'-8" 6'-8" 13/8', PLYWOOD 2 PAINTED , WOOD Z n OVER COMPACTED FILL ry Q ro
-' A-5 � =1 .O .
Q TD I ,� ar-24 — Ur--24 FAMILY w
1 Q O NEW FINISH FLOOR
(EXISTING)
MEANS OF ESCAPE NOTE: � � � � — — TO M4TCH EXISTING �"�`�\'.'�.`. - .` ; •
.;`
Z _ 2'-Sri 2�_Srr 2 lFFE15.167 .�. ; t;�' f c,
I. - OPENING IS REQUIRED t0 SATISFY REQUIREMENTS OF SECTION 515 OF SFBC - TD
AND NFPA 101, 1994. 01 O -.isi
«a _
2. - NFPA 101 . 21-2.43 $ ( ,ASTER BEDROOM
GLAZING NOTE: 3 (NEW) r ✓,a. ;may
EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPEN PROVIDE CATEGORY II SAFETY GLASS At ALL GLARING M SLIDING AND `'�I I @ TC \ 01'x,
POOR FROM THE INSIDE OF THE CLOSET WH 1 D
SWINGING DOORS,AND M SNOWEM5 ENCLOSURES INCLUDING ANY � � �� � ' ,, i� Vii'•:y'
3 - NFPA 101 : 21-2A44 GLARING WITHIN 60"OF THE FINISH FLOOR SUIWACE IN WALLS SI�OUNDMG I I 0-0 TOP OF 4 GONG.SLAB I •.
EVERY BATHROOM DOOR SHALL BE DESIGNED TO ALLOW THE ANY TUB OR SHOVER v ON GRADE OVER WELL COMPACTED
OPENING OF THE LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY ( FILL AND 6 MIL VISCUEEN FEW. � � ( -, UTILITY
WITH 6x6 WIA WA W.WF. (EXISTING)
4 - NFPA 101 : 21-2.4B �, n 1 c� uw
DOORS SHALL BE SWINGING OR SLIDING u
1S -Z
5 - NFPA 101 : 21-2.4b - — WF-ib —
NO DOOR IN ANY MEANS OF ESCAPE SHALL BE LOCKED AGAINST EGRESS — —WHEN THE BUILDING Is OCCUPIED. ALL LOCKING DEVICES WHICH IMPEDE OR PROHIBIT EGR!ESS OR 4 4 TG 1 _ — — — — — — — TC
WIC-44 CANNOT BE EASILY DISENGAGED SHALL BE PROHIBITED
BURGLARY INTRUSION MOTES No,_(011
I. ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK TO BE 6. GLASS AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN OF-16
KEY OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6,000 NATIONAL STANDARDS INSTITUTES-STANDARD 29-1.1. 16" x 12' CONC.FOOTING WITH NEW ADDITION EXISTING HOUSE
POSSIBLE KEY CHANGES OR LOCKING COMBINATIONS. IF KEY-IN- 295 Cpq,I•I••
THE KNOB LOCK IS USED THERE: SHALL BE AN AUXILIARY SINGLE I. VISION PANELS IN EXTERIOR DOORS OTHER THAN GLAZING
DEAD BOLT WITH HARDENED BOLT INSERTS. WITHIN 40" OF THE INSIDE LOCKING ACTIVATING DEVICE OF
LOOSE AND SWINGING DOORS SHALL COMPLY WITH AMERICAN 1
2, THE ACTIVE LEAF OF PAIRS OF EXTERIOR SWING DOORS SHALL NATIONAL STANDARDS INSTITUTES-STANDARD 29'1.1. W
HAVE SAME LOCKS AS REQUIRED FOR SINGLE EXTERIOR SWING
DOOR THE INACTIVE LEAF OF THESE PAIR OF DOORS SHALL S. SINGLE SWING EXTERIOR AND SWING DOORS CONNECTING LIVING FLOOR PLAN
HAVE MULTIPLE POINT LOCKS WITH 5/8" MIN. THROW BOLTS AREAS WITH GARAGE AREA SHALL BE A MIN. 1 3/8" THICK, 17
WITH INSERTS. SOLID CORE, AND SHALL BE SECURED WITH A LATCH AND SINGLE
DEAD BOLT SETS WITH LATCH THROW MIN. OF 1/2" AND BOLTS SCALE: 1/4" = V-0"
3. HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE NON HAVING A MIN. OF 1" THROW.
J
REMOVABLE PINS.
S. FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR W ,=
4. JAMBS OF ALL EXTERIOR OFFSET TYPE IN SWING DOORS BE SCOPE OR VISION PANEL. a E
RABBETED, OR OF SIMILAR FABRICATION, TO PREVENT ® W O
DEFEATING THE PURPOSE OF THE STRIKE AND THE INTEGRITY OF 10. ALL.LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF
LOCKS AND LATCHES. RESISTING A FORCE OF 300 LBS. APPLIED IN ANY MOVABLE
DIRECTION AND IN ACCORDANCE WITH RESISTANCE STANDARDS W +�
5. SINGLE SWINGING EXTERIOR DOOR IF WOOD, SHALL BE SOLID SET FORTH IN SOUTH FLORIDA BUILDING CODE.
CORE OF NOT LESS THAN 1 1/8!' THICK
® Cj) 00
r
�— -N 00
U �
® C,
Z o
V �
COLUMN SCHEDULE FOOTING SCHEDULE rn
O
LONGIT. REINF. TRANSVERSE W Lo n
MARK TYPE SIZE: REINFORCEMENT TIES REMARKS MARK SIZE DEPTH REMARKS z
Top sort. RE INF.
TC GONG" 8"x12" 4 a 5 �] �' 3 '� 12" WF-I(o 16" 12" 2 05 Date 01-29-01 v Y
TD GONG. a xa 1 " 5 1 WF-24 24" 1211 3 +► g
Scale AS NOTED
Drawn G.D.J.
Job 00-320
Sheet
A 3
Of 8 Sheets