01-0106-006 --- __-- - _ _ - REVISIONS BY
3-5-01 (ZONING) GDJ
GENERAL. NOTES - -
I. CODES AND REGULATIONS:
ALL CONSTRUCTION SHALL-COMPLY WITH THE PROVISIONS OF THE LATEST .--_.� - --
ADOPTED"EDITION OF THE SOUTH FLORIDA BUILDING CODE AND WITH-ALL S.W.ORDINANCES'01=-DADS COUNTY, FLORIDA. W 415t. STREET
IN ADDITION, ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE — — — —
SECTIONS OF THE FOLLOWING CODES: w�....,,
a. N.F.PA. 101 LIFE--SAFETY-,CODE . LATEST EDITION
b. N.E.C: LATEST EDITION
c. FLORIDA:ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION.
LATEST EDITION y N
ci. Al:5.A ACCESSIBILITY REQUIREMENTS. LATEST EDITION--- .----- --�
e. UNIFORM FEDERAL ACCE5515ILTY STANDARDS.-LATEST EDITION"°
F. ENERGY EFFICIENC_Y_,CODE-FOR•-BUILDING CONSTRUCTION, 5000,
FLORIDA STATE. LATEST EDITION p
2. THE CONTRACTOR SHALL FIELD CHECK AND VERIFY ALL EXISTING
CONDITIONS AND DIMENSIONS PRIOR TO SUBMITTING BID AND STARTING
ANY WORK THE CONTRACTOR SHALL NOTIFY -IN WRITTING- THE ARCHITECT/ENGINEER '
tn
OF ANY ERROR, INCONSISTANCY OR OMISSION THAT HE MAY FIND PRIOR TO
PROCEEDING WITH THE AFFECTED PORTION OF THE WORK. THE MEANS OF
Lt-
CORRECTING IT SHALL BE APPROVED BY THE ARCHITECT PRIOR TO THE N
IMPLEMENTATION OF THE SOLUTION.
N Q
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL EXISTING L1 d- :
UTILITIES WHETHER SHOWN HERE OR NOT AND FOR PROTECTING THEM AND EXISTING p
OTHER PHYSICAL PROPERTY FROM DAMAGE. THE CONTRACTOR SHALL ONE p Vn
BEAR ALL EXPENSE OF REPAIR AND/OR REPLACEMENT OF UTILITIES STORY SINGLE Ld
OR ANY OTHER EXISTING PROPERTY DAMAGED BY OPERATIONS IN FAMILY J
CONJUNCTION WITH THE EXECUTION OF THIS WORK REWORKING OF DAMAGED RESIDENCE. W V)
PROPERTY SHALL BE TO ORIGINAL CONDITION OR BETTER. 5809 SW 41st. ST.
MIAMI, FL W }
F.FL. EL. 0.00' Of z
4. THE CONTRACTOR SHALL PROVIDE A COPY OF THE BUILDING PERMIT AND B (' W Z
ALL SUB-PERMITS TO THE ARCHITECT FOR RECORDS.
61 Z m
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY Q, 0 Ld CD
OF THE SITE WHILE THE WORK IS IN PROGRESS AND UNTIL IT IS COMPLETED. 0 Z 6114-
W Z
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING ALL DEBRIS cz N Q g ro
FROM THE PREMISES AND FOR KEEPING THE SITE IN A CLEAN (BROOM) L1J
CONDITION AT ALL TIMES. �'-7" 15'-10" EXISTING g � a ry — p
900 GLS 1 !7 N �.
EXIST SEPTIC TANK ,� Q U 0)
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS SET B `, g,U� > C) z
OF CONSTRUCTION INCLUDING SCAFFOLDING, SHORING, BRACING, ETC. 1
NEW � r1.
0 ADDITION '�' 0 Lo
8. THE ARCHITECT/ENGINEER SHALL NOT BE RESPONSIBLE FOR "MEANS AND METHODS", I FIT T1 _1 ; � o p
TECHNIQUES, SEQUENCES AND PROCEDURES OF CONSTRUCTION, NOR FOR "Q EXISTING
IRE ENCE I 13�i5 SFI I I � ' Q J Q v ro
SAFETY MEASURES AND PROGRAMS RELATED TO THE CONSTRUCTION. l`
I IA I1�lF IIE I � L d — 4 •3z
9. THE ARCHITECT AND/OR ENGINEER MAKE NO GUARANTEE OR WARRANTY I %r '' �'C,9 C) .N CL,-,
k FOR PRODUCTS NAMES BY TRADE NAME, MANUFACTURER OR OTHER C _
REFERENCE. n �
50.0
'10
Al
z 0 N INCx:
PERMITTED OR
REQUIRED PROVIDED
LOT AREA: - 5,5005F. C,•, •i--
GROSS BUILDING AREA - 1,2425F(EXIST)+29I8F=1,5396E --
BUILDING STORIES: (PERMITTED) 2 -
LOT COVERAGE (ALL UNDER ROOF): 30% 281.r1.(INCLUDING-ADD ITION) -
_ BUILDING HEIGHT(TO ROOF RIDGE): 25'-0" 12'-011 ����� ��SCi�����O�' -
MAXIMUM IMPERVIOUS COVERAGE (51.SF) 4551. 3351.
EXISTING HOUSE=1,242 SF x 2591.= 311 SF(2591.)
PROPOSED ADDITION= - 213-1 1 SF LOT 1-1 BLOCK I SETBACKS REQUIRED PROVIDED -
UJESTERFIELD MANOR SECTION THREE, I- -
-- -
FRONT 25'-0" "' 25'-2 1=5 2-? g
SIDE DADE COUNTY, FLORIDA
SIDE STREET 15'-0" N/A
REAR 25'-0" 36'-1 -
SITE TO BE FILLED TO COUNTY FLOOD CRITERIA ELEVATION N.G.V.D.
OR AN ELEVATION NO LESS THAN THE HIGHEST APPROVED CRO SITE PLAN
ELEVATION OF THE ROAD ABUTTING THE PROPETY.
AREA ADJACENT TO LAKE OR CANAL TO BE GRADED SO AS TO PREVENT
DIRECT OVERLAND DISCHARGE OF STORMWATER INTO LAKE OR CANAL.
LOT WILL BE GRADED SO AS TO PREVENT DIRECT OVERLAND DISCHARGE 1/16" = 1'-0"
OF STORMWATER ONTO ADJACENT PROPERTY. - -
APPLICANT WILL PROVIDE CERTIFICATION PRIOR TO FINAL INSPECTION.
LOWEST FINISHED FLOOR ELEVATION ` '
SOIL. STATEMENT: W �
(INCLUDING BASEMENT)
AFTER VISUAL INSPECTION OF THE PROPERTY'
DISTRICT ELEVATION DEL A SOIL COMPOSED OF LIMESTONE ROCK AND SAND W r�
DADE COUNTY FLOOD CRITERIA DCEL WAS FOUND WITH AN ESTIMATED SEARING
CROWN OF ROAD 12.61 CAPACITY OF 2000, PSF. j �
DISTRICT C.H.H SRH OTHER
W 111
_ -
REQUIRED 13.53 ' '-• •�
PROPOSED• 15.16 - 0 LL
LOWEST FLOOR AS-BUILT ELEVATION SURVEY IS U
REQUIRED BEFORE MAKING ANY INSPECTION ABOVE N N
LOWEST FLOOR z N r--
O 00
*SHALL BE INCHES ABOVE FINISHED GRADE
+� 00
U)
ANY ,4PPLICA5L E RESMUT104 : Q Q d-
NOTICE:
Z p
IN ADDITION TO THE REQUIREMENTS OF THIS PERMIT, THERE MAY BE
ADDITIONAL RESTRICTIONS APPLICABLE TO THIS PROPERTY THAT MAY O
BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY. SECTION 553.19 (10),
FLORIDA STATUTES, EFFECTIVE 1/10/81 L0 a_
A SEPARATE PERMIT WILL BE REQUIRED FOR ALL DRIVEWAY APPROACHES
ONTO PUBLIC RIGHT OF WAY. CONTACT PUBLIC WORKS DEPT.
THE HEIGHT OF FENCES, WALL AND HEDGES SHALL NOT EXCEED 2.5 FEET Date 11-21-00
IN HEIGHT WITHIN 10 FEET OF THE EDGE OF ANY DRIVEWAY LEADING TO
RIGHT OF WAY.
Scale AS NOTED
THE HEIGHT OF FENCES IS BEING MEASURED FROM GRADE. GRADE EQUALS
TO THE ELEVATION OF PUBLIC SIDEWALK OR GROWN OF ROAD. Drawn G.D.J.
Job 00-320
Sheet
A-1
Of 8 Sheets
y