01-0102-005 r
NUM DATE REMARKS
FINISH NOTES
FINISH SCHEDULE a� D
F1 ALL DRYWALL SHALL BE 1/T UNLESS SPECIFIED_OTHERWISE.
DRYWALL SHALL BE INSTALLED- AS -PER--ALL UNITED._STATES
;• ROOM FLOOR BASS WALLS CEILING CLG. HT. REMARKS
CEILING TYP. SEE CEILING TYP. SEE GYPSUM REQUIREMENTS AND RECOMMENDATIONS 'AND THE -
FINISH
HE -
" = SCHEDULE :� ''• SCHEDULE REQUIREMENTS`OF THE SOUTH FLORIDA BUILDING CODE.
` MASTER BEDROOM CONCRETE WOOS DRWVALL DRYWALL 8'-0" F1,F2
ti F4 ALL WOOD WORK AND"TRIM 'SHALL-BE PAINT GRADE- PINE. -
�` MASTER CLOSET CONCRETE WOOD DRYWALL DRYWALL 8'-0" F1,F2
2"X4" WD. FRAMING ® 16" yam. 2"X4" WD. FRAMING ® 16" '
O.C. O.C. DOOR NOTES
D1 ALL EXTERIOR DOORS SHALL HAVE CURRENT--DADE COUNTY.-PRO- '
-DUCT:APPROVAL-AND--BE`.1NSTALLED-AS PER-ALL REQUIREMENTS,'
1/2" DRYWALL TYP. ;,. 518" TYPE "X" DRYWALL OF THE SOUTH'IFLORIDA BUILDING CODE AND THE PRODUCT ;x
FIRE BLOCKING NOTE: Y' O.C. FIRE BLOCKING NOTE: r' TYPICAL APPROVAL DOCUMENTS.
PROVIDE CONTINUOUS SOLID PROVIDE CONTINUOUS SOLID DOOR SCHEDULE _ - -- -- ~ - --- -__
2"X4" HORIZONTAL WOOD FIRE 2"X4" HORIZONTAL WOOD FIRE
BLOCKING BETWEEN STUDS BLOCKING BETWEEN STUDS D2 ALL EXTERIOR DOORS SHALL BE PROVIDED WITH DADE COUNTY '
3.5" FIBERGLASS BATT No. LOCATION WIDTH HEIGHT THK. OPER. CONST. MATER. FINISH JAMB REMARKS PRODUCT APPROVED HURRICANE SHUTTERS. SHUTTERS SHALL BE
AT MID HEIGHT OF WALL AT MID HEIGHT OF WALL Copywrite 2001 Gene Farmer and Associates
TYP. TYP. :; INSULATION INSTALLED AS PER THE REQUIREMENTS OF THE DADE COUNTY All drawings and ideas shown on this drawing
1 EXTERIOR 2-3'-0" 6'-8" 1-3/4" SWING ALUM/GLS ALUM. ESP WOOD D1,D2,D3,D4,D6 PRODUCT APPROVAL. are the property of Gene Farmer. They may
not be used in whole or in part without the
2 BEDROOM 2'-6" 6'-8" 1-3/8" SWING HOL. CORE WOOD PAINT WOOD D6 D3 ALL ROUGH FRAMING USED FOR ATTACHMENT OF THE EXTERIOR written permission of Gene Farmer.
'.; 2"X4" P.T. WD. BOTTOM '.; 7'X4" P.T. WD. BOTTOM DOORS SHALL BE PRESSURE TREATED PINE AND SHALL BE
PLATE TYP. PLATE TYP. 3 CLOSET 2'-0" 6'-8" 1-318" SLID.PCK. HOL. CORE WOOD PAINT WOOD D5,D6 SECURED TO THE BUILDING FRAME BOLTED TO THE SUPPORTING
WALL BY 112" DIAMETER BOLTS AND WASHERS AT 2'-O" O.C.
1"X3.5" WD. BASE 1"X3.5" WD. BASE
-;
TYP. TYP. D4 ALL EXTERIOR DOORS SHALL BE FITTED WITH A FULL WIDTH
:,• ALUMINUM THRESHOLD SET IN A FULL BED OF CAULK.
`'°,
It"• •'J'""' FINISHED FLOOR TYP. 'I" � "I" FINISHED FLOOR TYP.
D5 EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN
tt ': ttt OPEN THE DOOR FROM THE INSIDE OF THE CLOSET.
' SEE FINISH SCHEDULE r� ..t SEE FINISH SCHEDULE xi
„ ; WINDOW SCHEDULE
•- ,,, ,r, D6 ALL WOODWORK , I.E. DOOR JAMBS, CASING AND TRIM SHALL BE
,II III II III N0. TYPE SIZE GLASS FRAME SILL HEAD HT. REMARKS
PAINT GRADE ( SEE DETAIL ON THIS SHEET )
A SINGLE-HUNG 2-SH-35 TINTED ESP ALUM MARBLE 6'-10" W1,W2,W3,W4,W5,W6,W8
D7 ALL GLS. DR. FRAMES SHALL BE ESP FINISHED. COLOR: WHITE.
WINDOW NOTES
Q INTERIOR FRAME WALL W/ DRYWALL FINISH A INTERIOR '1-HR FIRERATED FRAME WALL W1 ALL WINDOWS_S_HALL-HAVE-CURRENT-DADE-COUNTY. PRODUCT,
�� �� �� �� APPROVAL`AND-.BE.INSTALLED AS PER ALL REQUIREMENTS_OF,
A3 SCALE= 3 : 1 -0 A3 SCALE= 3 : 1 -O THE,SOUTH FLORIDA BUILDING CODE AND THE-,.PRODUCT-APPROVAL F�1
DOCUMENTS. WINDOW-FRAMES--SHALL--BE"TIGHT-FITTING TO THE o
WINDOW OPENING AND BE FULLY CAULKED.
W2 ALL WINDOWS SHALL BE SECURED TO THE BUILDING STRUCTURE 'w
WITH ADEQUATE FASTENERS TO COMPLY WITH THE REQUIREMENTS
EXISTING PANEL-A OF THE SOUTH FLORIDA BUILDING CODE AND THE MANUFACTURER'S uJ1
150 AMP, 1 0, 3 W PRODUCT APPROVAL REQUIREMENTS.
W/ MAIN r//^
) U)
W3 ALL WINDOWS SHALL BE PROVIDED WITH DADE COUNTY PRODUCT V L V 1
CEILING TYP. SEE CEILING TYP. SEE APPROVED HURRICANE SHUTTERS. SHUTTERS SHALL BE INSTALLED
X. SCHEDULE SCHEDULE A/C DISC. AS PER THE REQUIREMENTS OF THE DADE COUNTY PRODUCT
W4 ALL WINDOWS SHALL BE EQUIPPED WITH "SOLAR GREY' TINTED
2"X4" WD. FRAMING ® 16" 2"X4" METAL FRAMING ® 16" GLASS AS MANUFACTURED BY THE PITTSBURG PLATE GLASS
O.C. O.C. COMPANY (OR APPROVED EQUAL).
1/2" DUROCK TILE BACKER W5 ALL WINDOW FRAMES SHALL BE ESP FINISHED. COLOR: WHITE. o
BOARD
:,• 1/2" DUROCK TILE BACKER
FIRE BLOCKING NOTE: y' BOARD FIRE BLOCKING NOTE: i'; —- - - - - - W6 ALL WINDOWS SHALL BE EQUIPPED WITH SCREENS IN FRAMES
PROVIDE CONTINUOUS SOLID PROVIDE CONTINUOUS SOLID TO MATCH THE WINDOW. SCREEN COLOR SHALL BE : GRAY.
TOP TILE TO HAVE BULLNOSE T^
2"X4" HORIZONTAL WOOD FIRE 2 7X4" HORIZONTAL WOOD FIRE t EDGE OR PROVIDE ADDITIONAL V 1
BLOCKING BETWEEN STUDS CERAMIC TILE TYP. SET IN BLOCKING BETWEEN STUDS t, BULL NOSE TILE COURSE W7 ALL WINDOWS SHALL BE SET IN A FULL BED OF CAULK.
AT MID HEIGHT OF WALL AT MID HEIGHT OF WALL P4
.�P• ;: FULL MORTAR BED. TYP. CERAMIC TILE TYP. SET IN 0 �
FULL MORTAR BED. W8 ALL EGRESS WINDOWS SHALL COMPLY W/ SFBC 3111(b)(3) �9
AND PROVIDE A CLEAR OPENING 20" WIDE, 24" HIGH AND o
TILE BACKER BOARD NOTE: TILE BACKER BOARD NOTE: 3-1/0 AWG THW CU.
ALL TILE BACKER BOARD JOINTS 2"X4" P.T. WD. BOTTOM �~ 2"X4" GALV. METAL BOTTOM / AND 5.7 sf IN AREA. LOCKING DEVICE SHALL BE LOCATED
ALL TILE BACKER BOARD JOINTS IN 1-1/7'C. UNDER NOT LESS THAN 54" AFF. CQ
SHALL BE FULLY TAPED AND `r PLATE TYP. SHALL BE FULLY TAPED AND PLATE TYP. SLAB
FINISHED PRIOR TO INSTALLATION '.� FINISHED PRIOR TO INSTALLATION
OF TILE. OF TILE. b W9 ALL WINDOWS AND DOORS WITH GLASS PANELS SHALL 'w
1"X3.5" WD. BASE 1-6 CU. IN 1/2" C. RECEIVE DADE COUNTY PRODUCT APPROVED HURRICANE v�
TYP.
SHUTTERS.
•t : t
1"X3.5" WD. BASE : 1"X3.5" WD. BASE
TYP'. tr, f, TYP. rr, �` UNDERGROUND SERVICE
„ ARCHITECTURE
.'• FINISHED FLOOR TYP. tt v. FINISHED FLOOR TYP. BY F.P.L.
II '' SEE FINISH SCHEDULE II SEE FINISH SCHEDULE
it
4
2-5/8" 0 X 10' LONG
GROUND RODS ® 6'-0"
APART AND DRIVEN A MIN.
OF 8'-O" BELOW GRADE
Q INTERI R rD
�!O FRAAAE WALL W/ CERAMIC TILE INTERIOR FRAME WALL W/ CERAMIC TILE EXISTING ELECTRICAL RISER DIAGRAM �.
Q� SCALE= 3" : 1 '-0" A$ SCALE= 3" : 1 '-0" NOT TO SCALE
s
Li
F i G E N E F A R M E R
A S S 0 C I A T E S
1/2" DRYWALL ARCHITECTS - PLANNERS
P. •; 1"X3" PT PINE t �' :'> (^., - ( (/ 13321 SOUTHWEST 124 STREET
STUCCO TYP. .Y " MASONRY
MIAMI,FL./F000068/305-235-7400
BLOCKING
FULL CAULK JOINT ! ARCHITECT
`j' �" 1.
PREFAB ALUM WIN.
SEE WIN. SCHEDULE ❑1, 1/2" DRYWALL ^' 1/2" DRYWALL
IU1 M
INSTALL AS PER ALL it
DADE COUNTY PRODUCT
❑ APPROVAL REQMTS. /
WD. CASING TYP. STUCCO TYP. —/ it WD. CASING TYP.
WINDOW SILL IS NOT SHOWN " =--- -- =---==-=-° - --- _ - --
SEE WINDOW SCHEDULE FOR __-�- ----- -^-----�- _ r°
_______ WD...
BRICK•-MOLD-_.__.. ------
SIZE AND MATERIAL TYP. i
GENE FARMER RA
WOOD. FIN. FRAME 2"X4" PT PINE ROUGH WOOD. FIN. FRAME AR 7565
DOOR BUCK W/ 5/32"
TAP CONK ANCHORS IN C
FULL CAULK JOINT 1"X3" PT PINE MASONRY ® 6" OC. WOOD DOOR STOP TYP. CONSULTANT
BLOCKING WOOD DOOR STOP TYP. ,► �-
NOTE:
STUCCO TYP. ��. R;': a.� DOOR SEE SCHEDULE FOR ALL WOOD FRAMING SHALL BE DOOR SEE SCHEDULE FOR .Y
1/2" DRYWALL FULLY CAULKED DETAILS
DETAILS THRESHOLDS SHALL BE SET IN
A FULL BED OF CAULK
,(
3
.w
�PROJ: .`
E EXTERIOR WINDOW DETAIL F INTERIOR DOOR DETAIL G EXTERIOR DOOR DETAILS A11111111113
DATE: 5-7-01
A3 SCALE= 3" : 1 '-0" A3 SCALE= 3': 1 '-0" SCALE= 391: 1 '-0"
BY: EDF OF 5