01-0102-003 A NUM DATE REMARKS ALTERATION NOTES 17'-r 17'-r Q 1 6-29-01 81 DG. DEPAMMENr REVSIONS 4 REMOVE EXISTING EXTERIOR WALL FROM A FINISHED FLOOR TO TOP OF DOOR. PRO- 8'-7" 8'-7" 8'-7" 8'-7" VIDE WOOD HEADER AS REQUIRED ABOVE 2 , DOOR. PATCH AND FlNISAH ALL ADJACENT I I I I SIDES TO MATCH NEW OR EXISTING FIN- . ISHES AS APPLICABLE. I I I I I Q REMOVE EXISTING INTERIOR WALL FROM . I I 4'-3" I B FINISHED FLOOR TO CEILING. ; LINE OF ROOF OVERHANG I 4 SIDES TO MATCH NEW ALL OR EXISTING ADJACENT FlN- I I ABOVE I WIND LO ISHES AS APPLICABLE. -56.0 I F I C CONSTRUCT NEW PT PINE DECK AND . I I b I I STEPS SEE F/S2 FOR DETAILS I CONSTRUCT NEW 2"X4" WOOD FRAME I C2 C2 to C2 C2 I M r--k---- -- ----- -----� ---------- Q WALL WITH 1/r DRYWALL EACH SIDE E ---- --------- �a FINISH BOTH SIDES TO MATCH EXISTING r 1,81 - - - - - - - - - -— - - ---�-- - - Copywrite 2001 Gana Former and Associates ADJACENT FINISHES. b 2"x12' PT PINE STAIR I b I � All drowinga and ideas shown on this drowing -- ------ STRINGERS AT 31' OC I b are the pro arty of Gane Farmer. They may r— 15-10" 8" I BLOCK UP EXISTING CRAWL SPACE AC- 4'-4" 8" 1' 3'-O" M MAX. I 8" 15'-1 8" 6'-0" �n I EE CESS OPENINGS CONSTRUCT NEW OPEN- not bo p r in whole or in part without the INGS SAME SIZE LOCATED AS INDICATED written errnieaton of Gene am�er. ON THE DRAWINGS C1 I I I r I WIND LOAD C1 ❑ I 56.0 LBS ❑ b b I I I I I I c I NEW BEDROOM bi ;� I 4" CONC. SLAB ON 6 IL VAPOR �j sl I �i sF2 BARRIER WITH 6X6-W2 2 W.W.M. :r I ON WELL COMPACTED C �D I I I I I I -- I FILL I I I I bi 21 I I C1 0 I ❑ o b I — I to C1Iol L__j b I El I C14 I I I I I I a I 3 3 •�• I 'b �, n I I I 3 24 I I I I I I I I K DO NOT SCALE ANY DRAWING ON THIS SHEET. FOLLOW WRITTEN DIMENSIONS ONLY. IF ANY ® � I I I I I I I ( b I I DIMENSIONS ARE MISSING. IN ERROR OR IN C2 I I I I I I I I I F `° I --------- SHALL BE NOTIFIED IMMEDIATELY BEFORE PROCEEDING I IL( I I CLO. I I CLO. I ---- - WITH THE WORK. A CONTRACTOR FAILING TO 0 I I I I I I I NOTIFY THE ARCHITECT AS SPECIFIED ABOVE I ( WF1 2"X8" PT PINE FRAMING ® 16" I I I I I O EXISTING O SHALL CREPANCY.RESPONSIBLE FOR SAID ERROR E I ----------- -- OC. I D � \ C2 I CLOSET �� � � _ ----I ------- - 2-2"X8' PT PINE LEDGER W/ 5/8" - - - I-— OWNER'S INFORMATION 'b0 C2 DW. BOLTS INTO CONCRETE AT I _______ EXISTING BATHROOM GEORGE YOSS ® 0% 24" OC SEE G/S2 I P-4 7621 SOUTHWEST 60 AVENUE y_ - I------------------- ® SOUTH MIAMI, FLORIDA k (305) 860-7040 LINE OF ROOF OVERHANG EXISTING STUDY _ ABOVE ELECTRICAL LEGEND [FOU NDAT101M PLRM SEE SHET S1 FOR STRUCTURAL 1/4!0=1 '-0" NOTES AND DETAILS PARTIAL F' ® PLAN e- 110V SPECIAL PURPOSE RECEP. I!r M I ( I �� � �� � � � 110V GEN.L PURPOSE RECEP. 4' P4 1/4! =1 '—U' 8' 'I @=GFl 110V GFI RECEPTACLE 0 4' 12' :: 220V SPECIAL PURPOSE RECEP. 0 0;• 4'�: 12' $ 2 WAY SWITCH 17'-r 6'-0" 2'-0" $3 3 WAY SWITCH _ ____ r ��---— � _ -=-------------- - $D 2 WAY SWITCH W/ DIMMER I I — I R* RECESSED LIGHT FIXTURE ARCHITECTURE TB to B1 TB Y SURFACE MOUNTED LIGHT FIXTURE -— -— PREFAB WOOD ROOF TRUSSES I T I I SEE SHOP DRAWINGS C1 I C1 _ I -(p� PENDANT LIGHT FIXTURE I I REACTI0N:�2209 LBS ----- - -" C1 I 1' GIRDER USS A B 1, NEW BEDROOM I 2' FLUORESCENT A REACTION 1052 LEIS UPLIFT: -1820 LBS UPLIFT: -617 LBS I I d I Q 2'x4' FLUORESCENT LIGHT FIXTURE C2 _ I I I SMOKE DETECTOR I TRUSS BRACING TYP. 1 I R-° SEE DETAIL I C2 \ ® DOOR CHIME .- C \ � /� �' ELEC. DISCONNECT F I 1a ;' I GIRDER TRUSS \\ ELECTRIC METIER GENE F A R M E R GIRDER USS I c m REACTION: 3526 LBS \ Q ❑ I A REACTION 2204 LEIS a UPLIFT: -2432 LBS A B \ I & UPLIFT: -1093 LBS ❑ ` � TELEPHONE OUTLET : A S S O C ° b I El I C1 I Q+ TELEVISION OUTLET I ATE S I I � c1 �� I ARCHITECTS — PLANNERS � I VENTILATION FAN 13321 SOUTHWEST 124 STREET a I I \ I M WU.FL./F000068/305-235-7400 I I I I I FLOODLIGHT R I c2 I I C2 ( I ARCHITECT ELECTRIC PANE_ CLO. I I CLO. EXISTING _ :'� .•� `,= : EMERGENCY LIGHT 711 CLOSET I rX4" WOOD TRUSS BRACING ------- EXISTING BATHROOM EXIT LIGHT - - CONT AT MID SPAN SE: D/S2 I -16 TB ------------------ GENE. FAE�t RA I AR 7566"'i,t i i s s"11%` --- -- -- — -- --L EXISTING STUDY p FIRE ALARM Q FIRE ALARM WITH STROBE ' ME CONSULTANTS •••••, `sy. Uj CEILING FAN W/ LIGHTS '^=� • '�s'_ ELECTRICAL FLOOR PLAN 0 0 MAFiM00D IdLACfAiI, PE 1� tin n n' �- CONSULTING ENGINEER #36921 ROOF FRAMING I�I�A SEE SHET S1 FOR STRUCTURAL 1/4 -1 0 I 13901 S.W. 108TH AVENUE NOTES AND DETAILS O H", FLORIDA 33176 1/4! =1 '-U' o CEILING FAN NO LIGHT PHONE: 305-235-2428 0 4' 12' O CONNECT NEW RECEPTACLES AND LIGHTING TO FDATE-. 0 ;;;;;;;4' ::13' ..................12' NEW CIRCUITS IN EXISTING ELECTRIC PANE- ......... ......... .......... ......... ......... .......... ......... ......... .......... .........:.................................... NOTE: ALL SYMBOLS ON THIS LEGEND ..........•....... SEE SHEET A-1 FOR PANEL AND METER LO- MIGHT NOT BE USED ON THE DWG. A = 2 CATION. 7-01 BY: EDF OF 5 ' :.:,cr.-r '.w:.-% 1.4x.4..C.:v.-.e mliUrt;.xH ..xir_n'a 1-.n rhi r.a 11NLtl.^YF'..•..:ti+'e w+^. ;.- • 111.: