Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
01-0098-015
ELECTRICAL NOTES: SYMBOL LEGEND: I. COOLING AND HEATING LOADS ARE NOT CONCURRENT. 3 WIRE MOUNTED a DUPLEX RECEPTACLE OUTLET 15A, , 8 AFF 2. PROVIDE ALL FINAL CONNECTIONS TO ALL EQUIPMENT AND APPLIANCES. BATHROOM DUPLEX RECEPTACLES TO BE RATED OR 20A1125V 3 WIRE,GROUND TYPE WALL MOUNTED. 3. PROVIDE ALL A/C CONTROL IN SEPARATE 1121C AS REQUIRED BY A/C DRAWINGS OR MANUFACTURER DIAGRAMS. MOTOR rr nn vJ 4. ALL LAVATORIES RECEPTACLES SHALL BE GFI TYPE. IN TV OUTLET MOUNTED AT 18' AFF T 5. EXTERIOR RECEPTACLES t0 BE GFI AND WEATHER PROOF. 4 TELEPHONE OUTLET MOUNTED AT 18' AFF 6. COORDINATE LOCATION OF ALL DISCONNECT SWITCHES WITH OTHER TRADES TO ALLOW SINGLE POLE LIGHT SWITCH,120/211V,20A 0 U NE.C.REQUIREMENT CLEARANCE. 3 THREE-WAY SWITCH, 1201211V,20A. 1. CIRCUITS WIRING REQUIRED TO BE AS FOLLOWS: 120V-2 WIRE (L-N)i 120/240V - 3 WIRE (LL-NA 240v - 2 WiRE (LL).WHEN EQUIPMENT GROUND IS REQUIRED INCREASE CONDUIT 0-1 MOTOR DISCONNECT SWITCH.l2)DENOTES NUMBER OF POLES,(30) DENOTES FRAME SIZE, 1111 H 1.111 ............................. ......_....................__.... ------------- ._. SIZE AS REQUIRED. (F)DENOTES FUSES AS PER EQUIPMENT MANUFACTURER 8. ALL WiRiNG TO BE COPPER THHN/THIiJN TYPE RUN IN CONDUIT. RELOCATE= EXIST. Tv rn �D SMOKE DETECTOR(120v).FIR)=X 00448 TANDEM WIRED SPRINKLEE� PUMP -- WP/CFI i---------- vJ B-6 B-8 U S. ALL COUNTER RECEPTACLES AND SWITCHES TO BE MOUNTED +48' MAXIMUM FINISHED FLOOR J JUNCTION BOX RECONNECT TO B_6 (TO BOTTOM OF PLATE).UNLESS OTHERWISE NOTED COORDINATE HEIGHT WITH ARCHITECT. EXIST. CIRCUIT )..0 10.COORDINATE LOCATION OF AIR CONDITIONER(INDOOR UNIT)DISCONNECT SWITCH WITH A/C W/PANEL "A, B-9 CONTRACTOR t0 KEEP N.E.C.REQUIRI=D CLEARANCE. PAD B-8 g-g WP/GFI E X 1ST i NCz CONNECT u 11.MINIMUM WIRE SIZE SHALL BE #12 THHN/THWN WiTH THE EXCEPTION OF 15A GENERAL LTG.AND ERVIGE LINE I I LOST \ BDOO1„I RECEPTACLE BRANCH CIRCUITS WHICH ARE #14 THHN/THUNN. _ TO EXIST. SEWER �------ � N 12.CONDUCTORS #b AWG AND LARGER SHALL BE THW. W P LINE --- -- , D RS - "---- B-s NEW D e-s — O N N S 13.ALL CONDUCTORS SHALL BE COPPER NEW CONC. B D 1Z001„i 0 0 o 14.CONDUIT IN FINISHED AREAS SHALL BE CONGEALED. PAD � B-7 -7 ---, B-5 B-9_---.__ O 0 E m As WALL BE EXPOSED. NEW cu-I W.P. -- ; J EXISTING B-� �., 15. CONDUIT iN UNFINISHED ARE AL 2 F IY 16.FUSES SHALL BE DUAL ELEMENT,TIME DELAY TYPE. L--- B-g0� 8-2,4 I�B-7 �X I T i NCB 11. INSTALL NYLON PULL STRING iN ALL EMPTY CONDUITS FOR FUTURE USE. ----------- -------- B-s 8,4T • s.B. y Ia.ALL MATERIALS SHALL BE U.L. APPROVED. Exisr. cu 19.WORKMANSHIP SHALL BE TO BEST COMMERCIAL PRACTICE. B-6 B-6 EXISTING-e 20. INSTALLATION SHALL BE IN ACCORDANCE WiTH LOCAL, STATE AND NATIONAL CODES. UNDERGROUND ' ELEC. SERVICE Zl.RECESSED LIGHT FIXi'URES OVER BATHTUB OR SHOWER SHALL BE COMPLETELY ENCLOSED �� B-g 8-1,3 NEW AND VAPOR PROOF SUITABLE FOR WET LOCATIONS. AHU-i EXIST. ����\NUJ B_g 230 22.ALL LUMINARIES SHALL BE PROPERLY SUPPORTED IN ACCORDANCE WITH THE CEILING SYSTEM NEW ELEC.METER -T�-- MANUFACTURER RECOMMENDATIONS AND LOCAL CODE REQUIREMENTS. E.P.'>3" METER \, B-8 Li 23.RISER AND DIAGRAMMATIC ONLY.THEY DO NOT SHOW EVERY BEND REQUIRED FOR THE EXIST. INSTALLATION. E P D I FXB-8 B-7 24.THIS DRAWING IS A GUIDE FOR THE INSTALLATION OF ELECTRICAL SERVICE.THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO PROVIDE A FUNCTIONING SYSTEM. EXIST. A.HU. EXISTiNC EXISTING 25.A/C EQUIPMENT WIRING BREAKER AND FUSE SIZES ARE BASED ON A/C EQUIPMENT SPECIFIED LIVING BOOM I i 5EPROOM ON CONTRACT DRAWINGS.CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING,BREAKER EXIST. EXIST. EXIST. AND FUSES SIZES IN ACCORDANCE WiTH A/C EQUIPMENT NAMEPLATE REQUIREMENTS IF DIFFERENT WATER DRYER WASHER I � FROM THAT SPECIFIED ON DRAWINGS,AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY HEATER NEW SMOKE [� � I I !"�1 DETECTORS I I D F e� THIS CHANGE.CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. M •• � an EX 1sT INCA B-� O 26.CONTRACTOR SHALL COORDINATE ALL HiS WORK WITH OTHER TRADES IN ORDER TO FURNISH AND INSTALL ALL CONTROL WIRING AND RACEWAYS ALL POWER CONTROL CIRCUITS WIRING AND U i N I NCB BOOM cto RACEWAYS AS SHOWN ON THE AIR CONDITIONING DRAWINGS OR SPECIFICATIONS. IF AIR CONDITIONING DRAWINGS REFER TO MANUFACTURER'S WIRING DIAGRAMS, THE CONTRACTOR SHALL QUI VERIFY WITH SAID MANUFACTURER ALL REQUIREMENTS AND INCLUDE ALL RELATED WORK iN HIS t� ONT G RA CT. 21. CONTRACTOR SHALL PROVIDE OWNER WITH A SEPARATE BID USING ROMEX IN LIEU OF CONDUIT. � C o � OWNER TO SELECT WIRING METHOD. ROMEX INSTALLATION SHALL COMPLY WITH NEC 336. D � � ELECTRICAL_ NOTES. ---____-- EXIST. B-7 �► REFRIG. Existinc{ electrical devices have not been shown. Contractor is required to visit sire and become familiar with the existin conditions prior to determining the EXISTING EXiSTiNCCXISTiNC work that needs to be accomplished g <iTCI-IAN F,41"iL"i- IR001"i 11,45T'ER � All electrical equipment shall be removed from structure to be removed. �4ccessible xlsr. B�Dfi�001"i lit racewa s, wires, b6xes, switches,and other electrical items associated with this work DISHWASHER shall bcg removed if not required for new equipment to continue in service. O O When electrical devices are installed in artitions or ceilin s to be removed, O the electrical contractor shall disconnect them up to the nxt outlet to remain or back to the panelboard. If existin to remain outlets are fed throw h demolished L----_____J artitions or cel I In s, the circuit s�a ll be rearranged to maintain cir uit continuity. Wire shall be removed back to the source from inaccessible raceways not reused. EXIST. EXIST. RANGE GARBAGE DISPOSAL All building construction affected by the removal or relocation of an piece of equipment shall be repaired and finished as required to match existin conditions. O p G I I l�o�C�I I �EXISTiNCz X15TIN GLO_ 5AT I I J 1 or 2 Hour Fire Rated �r� �n Through Penetration Firestop for ll W1JLlLKSCJ® Single Metal Pipe through O CD I Gypsum walls using I FIRE - SHIELD, F-rating = 1 and 2 Hr, T-rating = 0 Hr, 1 UL # WL1051 Drawn BZy: JA JA 3 3 Approv. Dr. JK Date: 2,12,01 ELECTRICAL FL�l�l SCALE: 1/4' m r-& N BevisiolE i 10 I or 2 - hour fire rated gypsum wallboard/stud assembly (angular space range, min. 1/4' to max, 5/8') ® Conduit - 4' diam,(or smaller) EMT or rigid steel © TREMCO # FIRE-SHIELD - min. 1/2' thickness of sealant Installed within opening with a min, of 114' crown around ground the penetrating Item applied flush with both side of wall assembly, _ PtojeCt No: 000 .A,• . l7i Sheet No: FIRE AND/OR SMOKE RATED WALL OR FLOOR PENETRATION DETAILS = = = " • `-' r (: Total: 6 ''• h gfle: 6:\JAK ED �'