01-0033-014 GENERAL NOTES: -
A. PLUMBING;CONTRACTOR SMALL EXECUTE ALL WORK SO TgAT it PRVCM5 w/
NOTE: Architecture
MINIMUM OF INTERFERENCE W/OTHER TRADES. Architecture
-- F
EXISTING 4" SANITARY CONTRACTOR t0 VERIFY SPECIFIC B. THE CONTRACTOR SMALL BE RESPONSIBLE FOR ALL FINAL CONNECTIONS TO.- _ = Civil Engineering
13 5 9 REFRIGERATOR REQUIREMENTS FOR ALL EQUIPMENT IN THE PLUMBING FIXTURES AND KITC44EN EQUIPMENT. THIS INCLUDES,BUT 13�W)T _ Structural Engineering
WITH ICE MAKER DEMO KITCHEN, INCLUDING BUT NOT LIMITED LIMITED TO,FURNISHING AND INSTALLING ALL TRAPS,DRA!NIS,;40 SUF rP E87 w/_ _ Mechanical Engineering
, TO,GAS REQUIREMENTS,ELECTRICAL STOPS. - - Electrical Engineering
— — — — — — — — — —� REQUI�MENtBI VENTILATION REQUIREMENTS, C. FIXTURE,EXCEPT FLOOR DRAINS AND CLEANOUI',ARE t0 BE PROVIDED BY Transportation Engineering
N _ - 8 ETC. CONTACT OWNER'S ENGINEER P Construction Management
p ISTDM 7 DISCREPANCIES OR CONCERNS EXIST. OWNER. Food Service Design
�y g I -1 -'/� _ A, THE CONTRACTOR SHALL VERIFY THAT ALL PIPING,AS SHOWN ON THESE Project Management
F€ESTR00:i1 I 1 FD - 3/4' DRAWINGS WILL NOT CONFLICT w/ANY EXISTING DRAINS,SCUTTLES,JOINTS, Site Investigation
STOAAQE 10 / , 12 i VENTS,EQUIPMENT,ETC Planning and Zoning
14 DISHWASHER 12 S-4 NOTE: B. COORDINATE ROUTING AND LOCATIONS OF WASTE AND VENT PIPING w/ALL
6 i CONTRACTOR TO VERIFY THE TYPE OF OTHER TRADES.
( - - --- S-1 16 CONSTRUCTION OF SLAB PRIOR TO MAKING C. THE PLUMBING CONTRACTOR SHALL COORDINATE w/THE GENERAL
Oyu ANY SAW CUTS. IF SLAB IS A POST TENSION CONTRACTOR AND OTHER TRADES,ALL REQUIRED OPENINGS AND
s / ,,, i i CONSTRUCTION,CONTACT OWNER'S ARCHITECT EXCAVATIONS. ALL REQUIRED OPENINGS IN NEW FOUNDATIONS,FLOORS,WALLS,
,� / —i i __O S-2 i R OMI IMMEDIATELY AND PERFORM HQ CUTTING OF AND ROOFS SHALL. BE DESIGNED INTO THE STRUCTURE INITIALLY BY THE USE
/ I —i __ i I THE SLAB.
T- OF SLEEVES,CURBS,M. CUTTING AND PATCHING SHALL BE HELD TO A
3 / i I i MINIMUM.
I MI 17 i I t D. ALL NEW ITEMS PROJECTING THE THROUGH T ROOF SHALL BE FLASHED A
EXOG { MINIMUM OF 12' ABOVE THE ROOF.ALL VENTS SHALL BE A MINIMUM OF 10' FROM 1201 Dublin Road
PA S t 4 I I OPERA1�pl, i I ANY OUTSIDE AIR INTAKE. Columbus,Ohio 43215-1026
FtE8TR001A ( i "
Tel: 614.221.0840
OQTCf�N 3/4 i t E. COORDINATE ROUTING AND LOCATION OF PIPING WITH DUCTWORK,LIGHTS,AND
r----- ---------V- --- - - -------------------------------------------i i I I i email: InboxQwdae.com
------ --------V---------------------- ------------+----------------------------------------Y-------------- —
STRUCTURE.PIPING SHALL RISE,JOG OR OFFSET AS REQUIRED t0 AVOID Fax: 1 .@wd 8
CONFLICTS.MODIFICATION OF ST PIPING O RESOLVE fGT
/ FCO - -- - - SAN -_ —__ __ __ __ __ _- -- SAI� - ARISING FROM LACK OF COORDINATION WITH EXISTING CONDITIONS SHALL R3E www.wdae.com
___HW--��-� -- -- -- -- -- - 411- - - - - - - - - - HW - - - - - - - DONE BY THE PLUMBING CONTRACTOR At NO EXPENSE TO THE OWNER,cul
- - - - - - - - - - - - R PROVIDE DI-ELECTRIC COUPLINGS,AT ALL DISSIMILAR METAL PIPE
W-1 W-1 W-1 W-1 W-1 W-1 CO 2
FCO / CONNECTIONS.
G 3/4 KEYED NOTES:
S-3
1
15 / O1 NEW GAS PIPING RUN TIGHT AGAINST JOIST TO EXTERIOR OF BUILDING.
CONTRACTOR TO COORDINATE METER SET AND SERVICE REQUIREMENTS WITH
GAS COMPANY PRIOR TO BID.
O2 CONNECT NEW COLD WATER TO EXISTING COLD WATER LINE AND METER WHICH LU
CW
FEEDS THE EXISTING RESTROOM AREA FROM OUTSIDE THE BUILOMG. CONNECT
DOWNSTREAM OF WATER METER. CONTRACTOR TO FIELD VERIFY EXACT
LIUXCH 1110014 / / SALES LOCATION OF METER AND SERVICE SIZE PRIOR TO BID. IF SERVICE IS
SMALLER THAN 1-1/2' ,AND/OR TAE METER IS SMALLER THAN 1',THEN
r *� / CONTRACTOR t0 COORDINATE WIT14 WATER DEPARTMENT TO UPSIZE EXISTNG
SERVICE AND METER AS REQUIRED.
11 3 EXISTING FLOOR DRAIN TO REMAIN.
4 EXTEND NEW 3' VENT THRU ROOF
/ SALES 5 NEW WATER HEATER EQUAL t0 A.O.SMITH MODEL "DSE-40' HAVNG A '11 GPH
RECOVERY,10' TEMP RISE,40 GALLON STORAGE TANK 208V,3PH,11 AMP, 120
KW,2 ELEMENT,WITH DIVERSION THEpOSTAT.
11 0 3/4"GAS RUN UNDER SLAB TO COOKING APPLIANCES.MAKE FINAL
CONNECTION W/SHUT-OFF,DIRT LEG, AND FLEXIBLE CONNECTION. PROVIDE
SALES REGULATOR At APPLIANCE AS NECESSARY. ROUGH IN AT 34 AFF
/� 11 7 3/4" HW 4 3/4' CW DROPPED EXPOSED TO NEW WATER HEATER
V/ 8 In' CW AND W N HW DROP DOWN IN WALL.
9 1/4" CW DROP DOWN M WALL TO OILER SUPPLIED REFIGERATOR. PROVIDE D
BALL VALVE AND WATTS 001 BACKFLOW PREVENTOR
10 3/4' HW AND 3/4' CW DROP DOWN IN WALL 1/2' HW AND 1/2' CW RN TO DOUBLE O
11 BASIN SINK 1/2" HW AND I/2" CW t0 PENETRATE FLOOR AND EXTEND t0 CD
COOKSMK LOCATED AT ISLAND.
11 KITCI-EN EQUIPMENT FOR DISPLAY ONLY. NO PLUMBING CONNECTION
NECESSARY
11 11 11 12 INSTALL MECHANICAL GA,VALVE PROVIDED BY MOOD FIRE PROTECTION
CONTRACTOR ABOVE CEILING. GAS VALVE ACTIVATED BY A TRIP WIRE WHEN
CD HOOD SHUTS DOWN.
13 CONNECT NEW 4' SANITARY LINE t0 EXISTING SANITARY MAIN. CONTRACTOR
TO FIELD VERIFY EXACT LOCATION AND SLOPE OF EXISTING MAIN PRIOR TO
MAKING ANY FLOOR CUTS CONTRACTOR TO VERIFY ADEQUATE SLOPE OF NEW
SANITARY LINES ARE MAINTAINED.
SALES 14 OWNER SUPPLIED DISHWASHER CONNECT SANITARY,HOT WATER THROUGH
CABINETS FROM SINK PIPING SHALL NOT BE EXPOSED.
15 OWNER SUPPLIED REFRKERATOR CONNECT 1/40 1/4' COLD WATER FROM SINK WITH
A NEW BALL VALVE AND WATTS 001 BACOLOW PREVENTOR
16 2" LOOP VENT FOR ISLAND COOKSM CONTRACTOR t0 INSTALL PER ALL
STATE AND LOCAL CODES. ~� '
ti aD I 17 1/2' HW AND In' CW PIPING RUN UNDER SLAB t0 COOIGSINK PIPING SHALL
HAVE NO FITTINGS UNDER SLAB.
:�..
SAS SALES PLUMBING LEGEND
` ^•�_
MTAL DESCRPTK)N
U) m
SAN SANITARY WASTE PIPING REVISIONS
CW COLD WATER PIPING
HOT WATER PIPNG
OFRCE/CLEICCAL
GA, GAS PIPING
11 ------V--------- VENT PIPING
lE) EXISTING PIPING
ch �t I GATE VALVE
CHECK VALVE
GAS VALVE
ISSUED FOR PBVXM
��� Gas UNION 11/16/00
GAS SOLENOID VALVE 188L1Efl FOR BM
0.FC0 FLOOR CIEANOUT 11/16/00
r- N GCO GRADE CL.E,ANOUt LAST FEVISED:
#1 11/16/00 �
—WCO I WALL
WDABE PROJECT NO.
® CONNECT NEW TO EXISTING 0.462
MET NUMM
m
0 1 4 8 16
c C.
w a
Cd z SCALE: 1/4" = T-0'