01-0033-004 GENERAL NOTES: A GENERAL CONTRACTORS AND SUBCONTRACTORS SHALL VISIT THE SITE PRIOR TO SUBMISSION OF BIDS TO FIELD VERIFY EXISTING Architecture CONDITIONS. THESE DOCUMENTS REFLECT THE CONDITION OF THE Civil Engineering . D6-13 I I BUILDING AND ITS' COMPONENTS At THE TIME OF THE INITIAL SITE VISIT. Structural Engineering SHOULD EXISTING CONDITIONS DIFFER FROM THOSE REPRESENTED ON Mechanical Engineering THESE DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE OWNER Electrical Engineering � � 1 (-- �'— � �— —� (1"R"IEDIAtELY PRIOR t0 tHE SUBMISSION OF B1D8. Transportation Engineering r N I Construction Management 1 1 I 5 I B. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL 31 / Food Service Design 1 ( Project Management W011 'S I I 18 I -------------------- 2 I A9-05 I I DEMOLITION WORK REQUIRED TO IMPLEMENT NEW WORK,AS SHOWN ON 1 I 26 i 1 1 - 31 17 // r----------- — I OTHER DRAWINGS 1 , , , S / �� Site Investigation // ,�' �. I C. IF FIELD CONDITIONS DIFFER FROM THE CONSTRUCTION DOCUMENTS, THE Planning and Zoning UIJA&E 1 I �\ I 2 I A7-04 ��� \\ OM I I GENERAL CONTRACTOR SHALL CONTACT THE ARCHITECT IMMEDIATELY. 1 7 1 OP TIONAL KITCHEN 16 • � — � � I 31 / r `� � � � D. GENERAL CONTRACTOR SHALL COORDINATE PREPARATION OF ---------- ------ D6-14 I �� r I , \ 9 � � , EXISTING AREAS FOR NEW CONSTRUCTION. I 2 / 1 �� �\ ko�z , rn E. IT SHALL BE THE RESPONSIBILITY OF EACH RESPECTIVE CONTRACTOR 1 I �`� 6 / I I `� • ` I I I TO COORDINATE WITH THE OTHER TRADES. FAILURE TO DO 50,WILL r 00 I I �\;\� / t-----�------ --------� y j �\�\ I I I NOT CONSTITUTE GROUNDS FOR A CHANGE ORDER \ ��` �/ 30 \oS U2 \\\ I F. GENERAL CONTRACTOR SHALL COORDINATE WITH SEARS 1 14 FIELD REPRESENTATIVE FOR REMOVAL OF ALL EXISTING ITEMS. G. ALL EXISTING WALLS t0 REMAIN,UNLESS NOTED OTHERWISE. 1201 Dublin Road 7 I I H. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING EXISTING Columbus,614 221.0840 1 26 O Tel. 6 Ohio 43215-1026 2 2 I CONSTRICTION AND TO PATCH AND/OR REPAIR ANY OHMAGE INCURRED email: Inbox221.24 4 DURING DEMOLITION AND CONSTRUCTION. Fax: 614.221.2484 I. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL REQUIRED w oo.com www. d rM I i I BLOCKING IN WALL FOR PROPER INSTALLATION OF CA51NTRY AND �/ 10 _ 4 12 LARRY 1 EQUIPMENI It SHALL BE THE CONTRACTORS RESPONSIBILITY TO / / DISHWASI�RS I I_ I I COODINATE WITH THE FOR EXACT LOCATIONS FOR BLOCKING. ALL r m I 2 , , I I BLOCKING SHALL BE NON-COMBUSTILBLE. r/ 21 1 I J. ROUNDEDBULLNOSE CORNER BEAD ON ALL DRYWALL (TYPICAL). A9-01 J LAUMRY _ I SIGNAGE. A7 06 , I K CONTRACTOR t0 INSTALL OWNER SUPPLIED INTERIOR p DISHWASHERS ISHWA S ; COORDINATE WITH OWNER AS EXACT LOCATIONS AND SIGNAGE. LUNCH ROOM / /� I � 5 i I L. CONTRACTOR SHALL VERIFY THAT ALL "FIXTURES TO REMAIN" ARE Ov IN GOOD WORKING CONDITION AND ARE ACCEPTABLE t0 THE OWNER p� - 4 _ I M. ALL INTERIOR ISLAND WALLS t0 RECEIVE 1/2� BOARD a P�/ / o 5 STALES i OVER 1/2" PLYWOOD SHEATHING. REFER TO D1-02 4 ' DJ-0.3 N. INTERIOR WALL FINISH SHALL BE SPRAY ON KNOCK DOWN FINISH. COORDINATE WITH OWNER I I / r I rJ _ $ (SHWAS S EYE® N®TES: ® LL / OVENS r SALES - 1- •. 7 I 1 EXISTING WALL TO REMAIN. SALES I ° , i I 2 3 5/8 METAL STUD WALL w/ 1/2" GYPSUM BOARD. CONTINUE + GYPSUM BOARD 6" ABOVE FINISHED CEILING. _ TYP. BLACKOUT WINDOW FROM FLOOR TO IST HORIZONTAL FRAMING MEMBER I; 5 I o O FIELD VERIFY HEIGHT. >/ I� w I I I I I I 4 CASEWORK BY OTHERS. _ I_ 5 5 48" HIGH LOW WALL. REFER TO D� - 13 , 6 7'-0" HEIGHT WALL.REFER t0 D -- ' 1 MASS I I 6 I 1 I 7 PROVIDE (2)3 5/8" STEEL STUDS w/ 1/2"GYPSUM BOARD t0 FORM FULL D HE1GH I ELECTRICAL CHASE. VERIFY CHASE DOES NOT INTERFERE I fi 1 I w/LIGHTS AND DIFFUSERS. ® ® O I 1 I - D� 7 APPLIANCES,CABINETS AND SOLID SURFACE COUNTERTOPS l 7 4 X42 D��02 7 — PROVIDED BY OWNER AND INSTALLED BY OWNER �A �-p I D1 01 1 g 9'-0" HEIGHT WALL. I I 1f�ACTOR 1 O� 1 10 FRAME OUT EXISTING BULKHEAD TO FINISH FLUSH w/NEW FULL I i I KITCHEN HEIC44T FRAMING. 6 I I P 02 I I 11 6" METAL STUD DEMISING WALL w/518" TYPE 'x' GYPSUM BOARD o �a I 71hp I 5 - 1 O 6 EACH SIDE. FINISH STUDS AND DRYWALL. REFER t0 D1 01 1 7 SALES i I 12 REMOVE EXISTING DOOR AND FRAMING. FRAME IN OPENING TO I I I Q I I MATCH EXISTING WALL FRAMING. 13 oM I 13 36" HIGH LOW WALL. 3 5/8" 18 ga.METAL STUDS w/ 1/2" PLYWOOD I 11 I I I I Q R I I SHEATHING UNDER ONE LAYER 1/2" GYPSUM BOARD. REFER TO D1-05 14 ELECTRICAL SERVICE EQUIPMENT. REFER TO ELECTRICAL POWER PLAN I I 4 _ 5 I I 15 EXISTING WINDOW TO REMAIN. ILI q9®. , I , I 16 REMOVE EXISTING PANEL. REFER t0 ELECTRICAL POWER PLAN 07 i FOR ADDITIONAL INFORMATION. SEAL 1 SALES 8 I P$� � `���\ I FEATURE KITCHEN oM I 1 17 WATER HEATER REFER t0 PLUMBING DRAWINGS. _ �,`.•`� °,w�, ,`; I i N I `.` I I i ' 18 NEW ELECTRIC PANEL AND TRANSFOF4'1ER REFER TO Xoe 5 ELECTRIC POWER PLAN.¢ ( I 19 36" HIGH LOW WALL. FRAME WALL TIGHT TO EXISTING WINDOW FRAMING. !ti 8 I 5 - D1-02 1 ' O PROVIDE 1/2"GAP AT TOP OF WALL BETWEEN WALL CAP AND GLAZING. SALES BLACK LOWER SECTION OF WINDOW OU—�OPAQUE FILM APPROVED BY c� REFRJCERATORS 9 I I I 1 I WINDOW MANUFACTURER REFER t0 D1-03 ; �- : .� •, 5 ,0'1 FEA GFEN I A , ©0 3/4 THICK,32 DEEP LAMINATED MILLWORK PANEL. TOP OF PANEL t0 �� ,r • J7. TERMINATE At THE BOTTOM OF SOFFIT. REFER t0 ELEVATIONS FOR FINISH. '+,+ . ` ......,.. . .`G;-_I TYP. I ( 21 BOX OUT COLTER w/MILLWORK PANEL. �' 1 DTMP 3 , fi RAIVGFS/IUICROHOODS I 7 i 2 OFFICE EQUIPMENT BY OTHERS, INSTALLED BY OTHERS 1 yP I I 1 I 3 FIRE EXTINGUISHER BY GEC. REVISIONS 1 BARBECUE `o ' i 11 ' 4 NEW DOORS. REFER TO DOOR SCHEDULE. 1 I 6 1 5 FREE STANDING TABLE BY OIINER C N 1 #2 12/13/00 26 EXISTING RESTROOM CONFIGURATIONS t0 REMAIN AS IS. REFER 0 22 I a I I TO RESTROOM ELEVATIONS FOR NEW FINISHES. 1 a 5 q8-�o ( 7 I FEATURE KITCHEN 1 ' OF�CE/CLERICAL � EXISTING DRINKING FOUNTAIN t0 REMAIN. Q I I I I 8 G.C.t0 PROVIDE TELEPHONE AND ALARM BOARD AND MOUNT 1 to FEATURE KITCHEN i I It t0 THE WALL. T10N I I 9 PHONE PANEL. REFER t0 ELECTRICAL DRAWINGS. I 1 I I I 1 I 30 CONTRACTOR TO PROVIDE SOFFIT BUILT OUT AROUND HOOD. A7-01 I i 12 31 CONTRACTOR t0 CONTINUE STUD WALL t0 ROOF DECK PROVIDE J SLIP CRACK CONNECTION AT ROOF DECK t0 ALLOW ROOF DEFLECTION. --- VERIFY TYPE OF EXISTING WALL FINISH. IF EXISTING GYPSUM BOARD IS UL. I HOUR FIRE RATED,CONTINUE SAME t0 ROOF DECK BOTH SIDES. IF EXISTING FINISH IS OTHER THAN U.L. I HOUR FIRE RATED GYPSUM 15 15 15 O 15 15 15 BOARD,REMOVE AND REPLACE WITH 5/8" TYPE 'X' GYP BOARD ISSUED FOR PERMITS: 3 I 3 I BOTH SIDES. 11/16/00 4 ISSUED 11/16/00 _ '°®. °.i WALL LEGEND f /LAST REVl8ED' v m �> •a"i a t.t"f•,' , C S"' (r�1 r I #2 12/13/00 O } 6 him. S.s i1ih3Eti� v' ,I o O 11111111 18 GA METAL STUDS a 24 O.C. €�" . -�1 ..—flN-SIT u v�`�,,.—.�.w _ f � � WDAd�E PROECT NO. 0.462 18 GA METAL SCUDS 0 24" O.C.(LOW WALL) � �.� =, + U. —————_ EXISTING WALLS TO REMAIN. FINISH AS NOTED ON _' 't $�T NUMBER H INTERIOR ELEVATIONS. 0 1 4 8 16 . o o W z SCALE: 1/4" = T-O" Last Plotted: Last Saved: wdaV 12/12/00 16:03