Loading...
01-0357-001 U z 0 Q VVOOD DECK AND TRELLIS ADDITION oC U O F R THE K'2""' ESIDENCE F MR. ND MRS. RICH RD C CHRAN U 6131 SOUTHWEST 86thSTREET MIAMI, FLORIDA STRUCTURAL NOTES _ 1.ALL CONCRETE SHALL REACH A MINIMUM DESIRED ULTIMATE = STRENGTH OF 3000 PSI IN 28 DAYS WITH 5' SLUMP UNLESS - OTHERWISE NOTED IN DRAWINGS OR SPECIFICATIONS. A)FOOTINGS+SLAB ON GRADE F'c-250OPSI ALL CONCRETE MUST BE PLACED WITHIN 90 MIN.OF BATCH TIME ONE SET OF CYLINDER REOUIRED FOR EVERY 50yd OF CONCRETE OR LESS. I L I S T OF D R A W I N G S : LEGAL DESCRIPTION • 2.REINFORCING STEEL SHALL BE INTERMEDIATE GRADE A.S.T.M.A- 615(60 KSI YIELD)WITH DEFORMATION CONFORMING TO A.S.T.M. COVER SHEET SOUTH 1/2 OF LOT 5, BLOCK 8, OF SNAPPER CREEK GROVES, A-305 CURRENT EDITION.PROVIDE DOWELS OF SAME SIZE AND NUMBER AT All LOCATION PLAN, FOUNDATION AND FRAMING PLAN ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT ALL POINTS REOUIRED TO CONTINUE CONCRETE PLACEMENT.LAP ALL AND SITE DATA BOOK 44, PAGE 88, OF THE PUBLIC RECORDS OF DADE COUNTY, REINFORCING 61/2 TIMES BAR NUMBER. FLORIDA. A1.2 DECK PLAN AND DETAILS 3.ALL CONCRETE SHALL BE POURED IN DRY CONDITION +CONTRACTOR A1.3 TRELLIS PLAN AND DETAILS SHALL PROVIDE ADEOUATE DE-WATERING PRIOR TO AND PLACING CONCRETE A1.4 SECTIONS 4.CONCRETE COVERAGE SHALL BE AS FOLLOWS. V A Z I R I & A S S O C I A T E S, I N C. S T R U C T U R A L E N G I N E E R S GRADE BEAMS+FOOTINGS: HOSHMAND VAZIRI,P.E. MARINA LAKES 3' FROM BOTTOM TO TIES OR STIRRUPS. P.E.#39663 4900 S.W.74 CT. 9 610 MIAMI, FL 33155 2' FROM TOP+SIDES E.B.#7436 PH. 305.663 5617 JOB#2001-57 FAX 305.663 5614 5.SOIL STATEMENT DESIGN INSPECTION SUPERVISION RESTORATION INSPECTION OF THE SITE INDICATES SOIL CONSISTING OF UNDISTURBED SAND+ ROCK WHICH IS CAPABLE OF WITH STANDING 2000 PSF(MAX.)SOIL PRESSURE. T T T SI OU I I O III C i 11 O 11ONS 11 11 ) 1 MA II 'CIA S 13L I_VCO N I[- III_ I I I I N(;INI I �< `; IAI I 'i' NO II II ) lil f Ulll f"�OCf I DING Wl ih I[-,I- WORK. I I I I I AT THE TIME OF CONSTRUCTION,THIS OFFICE WILL PROVIDE TO THE BUILDING W I I I I I OFFICIAL,A LETTER SIGNED AND SEALED ATTESTING THAT THE SITE HAS BEEN OBSERVED AND THE FOUNDATION CONDITIONS ARE SIMILAR TO THE THOSE UPON Z WHICH THE DESIGNED IS BASED. I I ? I I 6.ALL LUMBER USED FOR FLOOR AND ROOF OR MISCELLANEOUS Revisions Q ITEMS MUST BE MIN.NUMBER 2 KD SO.PINE OR BETTER U.O.N., No. Description _ I Date 6 I 5 I 4 I V I 2 I 1 PROTECT ALL LUMBERS AGAINST CONCRETE WITH METAL OR APPROVED I PFHFPMIT REVISIONS /22/01 I I I I I METHOD. N I I 7.CONTRACTOR MUST VERIFY ALL DIMENSIONS AND CONDITIONS BEFORE PROCEEDING WITH THE WORK AND REPORT ANY DISCREPANCIES TO THE W I I I ARCHITECT AND ENGINEER FOR APPROPRIATE ACTION AND ALL WORK SHALL I I I I BE EXECUTED IN ACCORDANCE WITH ALL LOCAL AND NATIONAL BUILDING I I CODES AND GOVERNING REGULATIONS. OI I 8 THESE PLANS COVER STRUCTURAL ENGINEERING ONLY, FIRE RESISTANCE, INTERIOR FRAMING AND ALL ITEMS NOT SHOWN I SPECIFICALLY ON THESE PLANS ARE NOT PART OF OUR CONTRACT. PROJECT I I I LOCATION ACCURACY 1. CONTRACTOR TO VERIFY ALL DIMENSIONS AND CONDITIONS BEFORE PROCEEDING WITH THE WORK,AND REPORT ANY DISCREPANCIES TO THE ARCHITECT AND SOUTHWEST 86th STREET ENGINEER FOR APPROPRIATE ACTION. CODES ISUBMITAL: PERMIT SET 1. ALL WORK SHALL BE EXECUTED IN ACCORDANCE WITH ALL LOCAL AND NATIONAL BUILDING CODES AND GOVERING REGULATIONS+SOUTH FLORIDA BUILDING CODE 1994 EDITION LOCATION SKETCH METHODS SAFETY: DATE: MARCH 21, 2001 z V4 W SCALE:1' -50' THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL METHODS, PROCEDURES AND j A fit) D 0 1w 200' SEOUENCES OF CONSTRUCTION. CONSTRUCTION SITE SAFETY,INCLUDING ALL ••,-,! W ADEOUATE TEMPORARY BRACING AND SHORING, IS THE SOLE RESPONSIBILITY OF �� I r�C.4 � ir THE CONTRACTOR. '. Z N o .,, TE 'OF ;e.