01-0216-001 METAL DECK AND
STEEL BAR JOISTS
GENERAL NOTES :
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1). SUPPLY AND EXHAUST FANS ARE INTERLOCKED
FAN SCHEDULE : WITH A PILOT LIGHT IN THE KITCHEN AREA.
4 ® 0 MARK EF-1 SF-1 2). FIRE MODE REQUIRES THAT THE EXHAUST FAN
CONTINUES TO OPERATE AND THE SUPPLY FAN
SERVICE: HOOD HOOD
2X2 X 3116 112" DOUBLE BUILT-UP ROOF OVER HINGE MAKE: PENN VENTILATOR EMPIRE STOPS. ALL ELECTRIC APPLIANCES AND OUTLETS UNDER THE HOOD MUST SHUT OFF.
ANGLE NUTS CONCRETE DECK, MODEL: *FXI4BFT *ENSAU G10 D/D
CURB - 18GA GALV 3). FIXED PIPE EXTINGUISHING SYSTEMS IN A SINGLE
I/2 THREADED Z STL - ALL WELDED C.F.M. 2500 2250 HAZARD AREA SHALL BE ARRANGED FOR SIMUL-
ROD S.P. 1 .0 0.50 TANEOUS AUTOMATIC OPERATION UPON ACTIVATION
`-° 4" CURB FLANGE H.P. 0.75 0.75 OF ANY ONE OF THE SYSTEMS.
ELECTRIC: 115/1 /60 1 15/1/60 4). FIRE SYSTEM SHALL BE CONNECTED TO THE
HOOD FACTORY WELDED AMPS: 11 .0 11 .0 BUILDING FIRE ALARM IF ONE EXISTS.
BRACKET (6) 410 SMS R.P.M. 1365 900
(3) SIDES (6) 1/4" BOLTS NOTES: 1 , 3 2 5). FIRE SYSTEM PERMIT AND INSTALLATION BY 1). U.L. LISTED- YZHW, SUBJECT 762, WITH GREASE COLLECTOR AND DRAIN, HINGING OTHERS.
KIT, DISCONNECT. G). EXHAUST FAN MOTOR REQUIRES EXTERNAL OVER-
2). U.L. LISTED- 705 LOAD PROTECTION OR THE MOTOR WARRANTY IS
3). EXHAUST FAN MOTOR REQUIRES EXTERNAL OVERLOAD PROTECTION. VOID.
CURD AND FAN MOUNTING DETAIL 4). * OR EQUAL 7). EXHAUST DUCT SHALL BE I(o GAUGE GALVANIZED
STEEL - ALL WELDED , AIR VELOCITY - 1500 TO
2200 FPM. CLEANOUT5 AT 12' INTERVALS ON
HOOD HANGER INSTALLATION N T S HORIZONTAL DUCT.
N T S AIR BALANCE SCHEDULE: 3). MAKE-UP AIR DUCT SHALL BE GALVANIZED
STEEL - 24 GA PITTSBURG SEAM OR 2(o GA
EF-I - 2500 CFM
SNAPLOCK - AIR VELOCITY - 1200 TO 1650 FPM.
SF-1 + 2250 CFM
9). GREASE EXHAUST FANS SHALL BE PROVIDED
WITH A HINGING KIT WITH CHAIN STOP AND
NET - 250 CFM GREASE COLLECTION TROUGH.
10). FAN CURBS SHALL BE 18 GAUGE GALVANIZED
STEEL - ALL WELDED . GREASE FAN EXHAUST
NEGATIVE PRESSURE SHALL CURBS ARE A MINIMUM OF IS" HIGH.
NOT EXCEED 0.02 W.C.
11). MAKE-UP AIR FAN INTAKE SHALL BE A MINIMUM
OF 10 FT. FROM SOURCES OF CONTAMINATED AIR,
EXHAUST FANS, PLUMBING, VENT STACKS, ETC..
12). EXHAUST FAN TERMINATIONS SHALL HAVE A
10 FT. MINIMUM CLEARANCE FROM THE OUTLET
TO ADJACENT BUILDINGS, PROPERTY LINES,
GRADE LEVEL, COMBUSTIBLE CONSTRUCTION,
ELECTRICAL EQUIPMENT OR LINES.
GAS LINE -10i-0n SYSTEM
CYLINDER
I 22XIO I
EF-I�� Ln
I 1 I
I � 14X14 I
REMOTE PULL STATION 10' MIN
AT PATH OF EGRESS � SF-I
c ROOF STRUCTURE: BUILT UP ROOF ®0
24X10 -LIGHT WEIGHT CONCRETE PANELS
-STL BAR JOISTS T
z 12" RD O 14XI4 lr /
\ � o
G
22X10 O AD 12" RD
FD
I I �
\\-SUSPENDED CEILING
SF-I — / 30 NOT FIRE RATED
b"
MIN
GAS
APPLIANCES
HOOD ELEVATION
A%
PARTIAL PLAN
�✓ ' w ~� Ott
KITCHEN AREA
PROJECT. MIYAKO JAPANESE RESTA'TJ"R ,�„ x
LOCATION: 5344 SW 73RD STREET SOUTH MIA s FL
�
-- " BOLA RATON. FL TITLE: KITCHEN HOOD VENTILATION SYSTEM
= VENTILATION 800-859-0813 DATE: 2/16/01 DRAWN BY. F. P. SHEET.
4G2-I CHKD. BY. MECHANICAL
DWG. NO. HOOD
_ _ SYSTEMS, INC. REV. SCALE. 1/4" = 1'-0" 1 OF 2