Loading...
01-0216-001 METAL DECK AND STEEL BAR JOISTS GENERAL NOTES : . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1). SUPPLY AND EXHAUST FANS ARE INTERLOCKED FAN SCHEDULE : WITH A PILOT LIGHT IN THE KITCHEN AREA. 4 ® 0 MARK EF-1 SF-1 2). FIRE MODE REQUIRES THAT THE EXHAUST FAN CONTINUES TO OPERATE AND THE SUPPLY FAN SERVICE: HOOD HOOD 2X2 X 3116 112" DOUBLE BUILT-UP ROOF OVER HINGE MAKE: PENN VENTILATOR EMPIRE STOPS. ALL ELECTRIC APPLIANCES AND OUTLETS UNDER THE HOOD MUST SHUT OFF. ANGLE NUTS CONCRETE DECK, MODEL: *FXI4BFT *ENSAU G10 D/D CURB - 18GA GALV 3). FIXED PIPE EXTINGUISHING SYSTEMS IN A SINGLE I/2 THREADED Z STL - ALL WELDED C.F.M. 2500 2250 HAZARD AREA SHALL BE ARRANGED FOR SIMUL- ROD S.P. 1 .0 0.50 TANEOUS AUTOMATIC OPERATION UPON ACTIVATION `-° 4" CURB FLANGE H.P. 0.75 0.75 OF ANY ONE OF THE SYSTEMS. ELECTRIC: 115/1 /60 1 15/1/60 4). FIRE SYSTEM SHALL BE CONNECTED TO THE HOOD FACTORY WELDED AMPS: 11 .0 11 .0 BUILDING FIRE ALARM IF ONE EXISTS. BRACKET (6) 410 SMS R.P.M. 1365 900 (3) SIDES (6) 1/4" BOLTS NOTES: 1 , 3 2 5). FIRE SYSTEM PERMIT AND INSTALLATION BY 1). U.L. LISTED- YZHW, SUBJECT 762, WITH GREASE COLLECTOR AND DRAIN, HINGING OTHERS. KIT, DISCONNECT. G). EXHAUST FAN MOTOR REQUIRES EXTERNAL OVER- 2). U.L. LISTED- 705 LOAD PROTECTION OR THE MOTOR WARRANTY IS 3). EXHAUST FAN MOTOR REQUIRES EXTERNAL OVERLOAD PROTECTION. VOID. CURD AND FAN MOUNTING DETAIL 4). * OR EQUAL 7). EXHAUST DUCT SHALL BE I(o GAUGE GALVANIZED STEEL - ALL WELDED , AIR VELOCITY - 1500 TO 2200 FPM. CLEANOUT5 AT 12' INTERVALS ON HOOD HANGER INSTALLATION N T S HORIZONTAL DUCT. N T S AIR BALANCE SCHEDULE: 3). MAKE-UP AIR DUCT SHALL BE GALVANIZED STEEL - 24 GA PITTSBURG SEAM OR 2(o GA EF-I - 2500 CFM SNAPLOCK - AIR VELOCITY - 1200 TO 1650 FPM. SF-1 + 2250 CFM 9). GREASE EXHAUST FANS SHALL BE PROVIDED WITH A HINGING KIT WITH CHAIN STOP AND NET - 250 CFM GREASE COLLECTION TROUGH. 10). FAN CURBS SHALL BE 18 GAUGE GALVANIZED STEEL - ALL WELDED . GREASE FAN EXHAUST NEGATIVE PRESSURE SHALL CURBS ARE A MINIMUM OF IS" HIGH. NOT EXCEED 0.02 W.C. 11). MAKE-UP AIR FAN INTAKE SHALL BE A MINIMUM OF 10 FT. FROM SOURCES OF CONTAMINATED AIR, EXHAUST FANS, PLUMBING, VENT STACKS, ETC.. 12). EXHAUST FAN TERMINATIONS SHALL HAVE A 10 FT. MINIMUM CLEARANCE FROM THE OUTLET TO ADJACENT BUILDINGS, PROPERTY LINES, GRADE LEVEL, COMBUSTIBLE CONSTRUCTION, ELECTRICAL EQUIPMENT OR LINES. GAS LINE -10i-0n SYSTEM CYLINDER I 22XIO I EF-I�� Ln I 1 I I � 14X14 I REMOTE PULL STATION 10' MIN AT PATH OF EGRESS � SF-I c ROOF STRUCTURE: BUILT UP ROOF ®0 24X10 -LIGHT WEIGHT CONCRETE PANELS -STL BAR JOISTS T z 12" RD O 14XI4 lr / \ � o G 22X10 O AD 12" RD FD I I � \\-SUSPENDED CEILING SF-I — / 30 NOT FIRE RATED b" MIN GAS APPLIANCES HOOD ELEVATION A% PARTIAL PLAN �✓ ' w ~� Ott KITCHEN AREA PROJECT. MIYAKO JAPANESE RESTA'TJ"R ,�„ x LOCATION: 5344 SW 73RD STREET SOUTH MIA s FL � -- " BOLA RATON. FL TITLE: KITCHEN HOOD VENTILATION SYSTEM = VENTILATION 800-859-0813 DATE: 2/16/01 DRAWN BY. F. P. SHEET. 4G2-I CHKD. BY. MECHANICAL DWG. NO. HOOD _ _ SYSTEMS, INC. REV. SCALE. 1/4" = 1'-0" 1 OF 2