Loading...
01-0144-025 SAMUEL C MATTHEWS A R C H IT E C T AR 000W33 TRUNK DUCT 8546 S.W. 115 PLACE PLASTIC SEAL JOINT WITH DUCT BUSHINGS R METAL ! i 18 GAGE GALV. SHEET HAW, FLORIDA SEALER 4 TAPE t ! STEEL DAMPER BLADE: (305) 595.3149 CLINCH EDGES ! FULL HEIGHT OF MAIN DUCT. DOUBLE 1/4'4, GALV. BAR I I BEND LEADING EDGE LOW VELOCITY SUPPLY !1-1 2 IF POSSIBLE. DAMPER BLADE AIR DUCT(SEE PLAN VIEW) IL TO BRANCH DUCT-� LL Q _ DATE: GALV. STEEL ROD AIR FLOW 01-20-01 REVISIONS: SET SCREW SPACER REQ'D. ON INSULATED DUCTS TYP.DETAIL OF W* DUCT TAP WITH FLEXIBLE DUCT CONN. DETAIL DAMPER BLADE NTS TURNING VANES W/S.M. SCREW FASTERNERS IN DUCTS 8' O.C. x 'D' IF POSSIBLE OR LARGER In � , MARK DIRECTION OF 11 _� I BLADE ON BOTH ENDS _ OF SQUARE BAR. � � I I I ELBOW I I FLEXMASTER SPIN-IN I • DAMPER AND EXTRACTOR SCOOP ^. FITTING MODEL NO.08DE AIR FLOW FOR F15EROUS GLASS DUCT BOARD. 18 GAGE GALV.STEEL '1 DAMPER BLADE 7 F� SPACER REQ'D. ON /r 1 INSULATED DUCTS O SET SCREW JOIN FLEX DUCT TO SPIN- O Z GALV. STEEL ROD IN FITTING IN ACCOR 1DdCO p" Wd USE SEALER AND Z DAMPER BANDING DEVICE. Z S �L I T t E R FLEXIBLE DUCT a E-4 U tYi z 1-4 co c DUCT CONNECTION DETAILS E o � o Q o LOW VELOCITY SUPPLY AIR DUCT (SEE PLAN VIEW) RV.A.C. NOTES METAL ROUND FITTING 1. ALL WORK SHALL BE PER LOCAL CODES, NFPA AND LANDLORD'S CRITERIA. QUADRANT R TO OUTSIDE IDE INSULATION. 2. ALL FIBERGLASS DUCTWORK SHALL BE 1' THICK, WITH VAPOR BARRIER PROVIDE INSULATION ULATION ALL R/A DUCTS AND PLENUM BOXES ATTACHED TO THE REAR OF AIR HANDLING GUARD WHERE NITS SHALL BE 18 GA. GALV, METAL INSULATED WITH R=6 INSULATION, ERE NECESSARY ALL BATH RM. EXK & O/A INTAKE DUCTS SHALL BE NON-INSUL. GALV. METAL. i 3, DUCT WORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS & ACCORDING TO ASHRAE & SMACNA STANDARDS AIR FLOW 4. DUCT DIMENSIONS ARE IN INCHES AND CORRESPOND TO INSIDE DIMENSIONS WIDTH x HEIGHT, DUCT SYSTEM SHALL COMPLY WITH NFPA STD, NO. 90A AND/OR 90B. DUCTWORK AND MATERIALS SHALL BE CLASS 1 MATERIALS IN ACCORDANCE WITH U.L. 181 TESTS. INSULATED FLEX DUCT 5. COORDINATE LOCATIONS, SIZES & OPENINGS W/OTHER TRADES (6'-0' MA)<IMUM) NOTE: ON THE JOB. A/C CONTRACTOR SHALL PROVIDE THE COMPLETE DUCT THERMOFM OR EQUAL SYSTEM W/TURNING VANES AT ALL ELBOWS. SPILITTERS AND DAMPERS ONLY IN A NONE AS REQUIRED. A/C CONTRACTOR SHALL USE THE BEST PRACTICES OF THE SPRINKLERED BLDG. TRADE IN THE FABRICATION AND INSTALLATION OF THE SYSTEM, 6. ALL S/A & R/A GRILLES / DIFFUSERS SHALL BE NEW UNLESS NOTED OTHERWISE, AND SHALL BE LOCATED AND BALANCED IN ORDER THAT THEY DELIVER PROVIDE P F18ER3LASS THE REQUIRED CFM TO THE ENTIRE ROOM EVENLY & DRAFT FREE TO INSULATION SEALED TO NECK MAINTAIN THE FOLLOWING DESIGN CONDITIONSt 4 PERIMETER OF DIFFUSER INSIDE OUTSIDE RELATIVE HUMIDITY COOLING - 75 DB 95 DB - 79 WB 50% TO 60% SEAL JOINT WITH DUCT HEATING - 72 DB 40 - DB SEALER 4 TAPE 7. ALL TEM. CONTROLS TO BE VIA CENTRALIZED T'STATS. MOUNT T'STATS AT 5'-0' A.F.F. WHERE SHOWN ON PLAN. S. ALL AIR HANDLING UNITS ARE EXISTING TO REMAIN, UNLESS NOTED OTHERWISE. FIELD VERIFY CAPACITIES & CONFIGURATIONS. PROVIDE ALL NECESSARY SERVICE "! d & REPAIRS IN ORDER TO ACHIEVE OPTIMUM OPERATING PARAMETERS & EFFICIENCIES. F r, 9. SEE HVAC LEGEND FOR ALL S/A & R/A DIFFUSER / GRILLE TYPES. DIFFUSER 10. PROVIDE DUCT SMOKE DETECTOR IN HVAC DUCTS WHERE - I INDICATED ON PLANS, UNLESS FOUND TO BE EXISTING. + a 11. FIELD VERIFY/COORDINATE EXACT TERMINATION LOCATIONS OF ALL NEW O/A AND �' s; ,. '•;,? BATH ROOM EXHAUST DUCTS / GRILLES. 12. VERIFY COORD. LOCATIONS, CAPACITIES, AND SIZES OF ALL EXISTING o E FLEX15LE DUCT HEAT PUMP TYPE AHU'S AND EXIST. CONDENSER WATER PIPING. INSTALL NEW HEAT ' S.`, �r PUMP AHU'S (REPLACING EXISTING) AT 1ST FLOOR SPACE ONLY, PER MANUFACTURER'S I�1 CONNECTION DETAIL ,T.5 REQUIREMENTS, MAINTAIN ALL REQUIRED SERVICE CLEARANCES FOR HVAC UNITS PER THE MANUFACTURER'S REQUIREMENTS. PROJECT NO. 205048 SHEET M + 2 OF