01-0144-012 SAMUEL G MATTHEWS ' A R C H I T E C T 5YM50L LEGEND AR 0009M SYMBOL DESCRIPTION ' 8546 S.W. 115 PLACE ' MIAMI, FLORIDA DUPLEX RECEPTACLE 2 POLE 3 WIRE GROUND TYPE 20A, 125V MOUNTED M AT 18" APP. (NEMA 5-20R) NOTE: NO NEW ELECTRICAL CIRCUITS ARE (305) 595.3'149 REQUIRED. CONTRACTOR IS TO CONNECT SAME AS ABOVE , QUADRUPLEX RECEPTACLE RELOCATED 4 NEW FIXTURES TO EXISTING-:: SAME AS ABOVE ,MOUNTED ABOVE COUNTER 2'111480Y 20AMP CIRCUITS AS INDICATED ON OR MOUNTED AT 42" A . PLANS. FF SAME AS ABOVE WITH DEDICATED CIRCUIT NOTE: NO NEW EMERGENCY POWER CIRCUITS MATCHIWG COVER OUNTED 46" AFF. DATE: ARE REQUIRED. CONTRACTOR IS TO CONNECT 01-20-01 a TELEPHONE OUTLET WITH 3/4" EMPTY CONDUIT TO CEILING WITH PULL STRINGS. RELOCATED FIXTURES TO EXISTING 2111480Y MOUNTED AT 1S" AFF. (UNLESS OTHERWISE NOTED) "W" = MOUNTED AT 60" AFF. 20AMP EP CIRCUIT AS INDICATED ON THE REVISIONS: �— DATA OUTLET WITH 3/4" EMPTY CONDUIT TO CEILING WITH PULL PLANS. 03-19-01 STRINGS M.H. = 16" AFF. �T THERMOSTAT CEILING OR WALL MOUNTED JUNCTION BOX SAFETY SWITCH DISCONNECT. SIZED PER EQUIPMENT'S NAMEPLATE. MOTOR SIZE AS INDICATEDON DRAWINGS 2'x4' RECESSED OR LAY-IN FLOURESCENT LIGHT FIXTURE 2'x4' FLOURESCENT FIXTURE - NIG14T LIGHT , WITH EMERGENCY BATTERY PACK OR ON EMERGENCY SYSTEM I..�J U ❑ ❑ 2'x2' RECESSED FLOURESCENT LIGHT FIXTURE O LIGHTING FIXTURE (LUMINAIRE) TYPE. REFER TO LIGHTING FIXTURE SCHEDULE FOR SPECIFIC REQUIREMENTS AND CHARACTERISTICS. SURFACE MOUNTED PANELBOARD OR CABINET 20A, TOGGLE SWITCH, QUIET TYPE, 125/2"11v, MOUNTED AT 48" AFF. A = LETTER DENOTES LIGHTS SWITCHED 3 z 3-WAY SWITCH 4 = 4-WAY SWITCH EXISTING MEDICAL P = PILOT LIGHT D = DIMMER SWITCH , LEVITON DECORA 0 6 06-6 00W MAX. OFFICE 6 SPACE K = KEY OPERATED SWITCH EXISTNG M = MOTOR RATED SWITCH W/ THERMAL OVERLOAD PROTECTION CEILING BRANCH CIRCUIT HOME RUN CONCEALED IN CEILING, WALL OR CONCRETE SLAB. HOMERUN TO PANEL (U-ON. $12 IN 1/2" C.) SHORT TICKS DENOTE NO. OF PHASE WIRES. VA (� LONG TICKS DENOTE NEUTRAL WIRE. VA VA DOT. DENOTES GROUND WIRE. BRANCH CIRCUIT RUN CONCEALED IN GEILIW3, WALL OR CONCRETE SLAB. Z w FLEX CONNECTION z `� w 0 E-4 - AFF. ABOVE FINISH FLOOR O CQ U' WEATHERPROOF EQUIPMENT 0 W �, m ;k4 :z MTD. MOUNTED MODIFY EXISTING l- o x TYP. -n-Plc „ CEILINGS AS REQUIRED 0­4 rr--�� t°n GROUND TO INSTALL NEW 1-� JB JUNCTION BOX PARTITIONS Z N.T.S. NOT TO SCALE EMT ELECTRIC METALLIC TUBE ExtsTINCx ^ GRS GALVANIZED RIGID STEEL INSTALL NEW GYP. BD. CEILING F� GFG GROUND FAULT CIRCUIT INTERRUPTER CEILINGS TO MATCH EXISTING Cl-G. HGTS. vyll CONDUIT EMT. ELECTRICAL METALIC TUBING CEILW2 CEILING CE Exis CEIL EXISTING CEiLN(Y E.W.C. ELECTRIC WATER COOLER EXIsTNG CEILING E.W.1-1. ELECTRIC WATER HEATER GF1 GROUND FAULT INTERRUPTER EXISTING NOTES CEILTMG �� CE104 CEILING EXISTING 1. THESE ARE STANDARD SYMBOLS AND MAY NOT ALL APPEAR ON THE PROJECT Q celllrl� DRAWINGS,HOWEVER, WHEREVER THE SYMBOL ON PROJECT DRAWINGS OCCUR, THE ITEMS SHALL BE PROVIDED AND INSTALLED UNLESS OTHERWISE NOTED. NEW Co EXISTING ARE TO MAt CEILNG 2. REFER TO DRAWING=S SPECIFIC NOTES AND COMMENTS FOR SYMBOLS NOT INCLUDED EXISTING CL R � R R d " IaGTS. ON THIS LIST. VN ec-a so-z . w 3. PROVIDE MEANS FURNISH AND INSTALL. 4. EVERY BRANCH CIRCUIT SHALL INCLUDE GROUND CONDUCTOR IN ADDITION TO THE cp`EIL REQUIRED NEUTRAL AND PHASE CONDUCTORS. EXISTNG ►t � IP CEILNG 5. REFER TO MECHANICAL DRAWINGS FOR EQUIPMENT'S LOCATION AND ELECTRICAL REQUIREMENTS AND PROVIDE ACCORDINGLY. A o 6. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NECESSARY CONTROL WIRING •`•`t�� ' FOR EQUIPMENT OF OTHER TRADES, INCLUDING TEMPERATURE CONTROL WIRING. ©•'!•ti�A ,, �l V O •J � • s LIGHTING FLAN PROJECT NO. 205048 1�1 SHEET E -- 2 OF 2