01-0057-021 Q Revisions: ** DOOR SWITCH IF REQUIRED BY CODE SIEMENS ELECTRONIC AND CUSTOMER CABINET "A" ELECTRICAL LEGEND ELECTRICAL NOTES 0 ** DS 0 SUPPLIED SYM SIZE DESCRIPTION REMARKS 1 Q 24 VDC 1) COMPLIANCE: ELECTRICAL WORK SHALL BE IN COMPLIANCE SUPPLIED AND INSTALLED BY CUSTOMER/CONTRACTOR WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE JUNCTION BOX © 3-PHASE MAIN CIRCUIT BREAKER, 480 VOLTS, 100 AMPS., SHUNT TRIP, FEEDING "Aa". BREAKER (NFPA-70), O.S.H.A. REGULATIONS, AS WELL AS APPLICABLE TO BE MOUNTED ON WALL AT 5'-0" A.F.F.. BREAKER IS FED FROM HOSPITAL'S PANEL. REGULATIONS OF CITY, COUNTY, STATE AND FEDERAL AGENCIES. 0 INCANDESCENT SEE POWER DIAGRAM ON THIS SHEET PROVIDE MATERIALS AND EQUIPMENT THAT COMPLY TO ANSI, IEEE 0 WARNING 6 FT' I AND NEMA STANDARDS. WHERE APPLICABLE, PROVIDE ONLY PIGTAILS LIGHT P ----- EMERGENCY POWER OFF BUTTON TO CONTROL "CB1" THAT MUST PREVENT RESETTING OF MATERIALS AND PRODUCTS THAT ARE U.L. LISTED AND LABELED. "CB1" WHEN IN "OFF" POSITION. EPO MUST BE RECESSED OR SHIELDED. CUSTOMER'S/CONTRACTOR'S WORK SHALL COMPLY WITH NECA © ----- STANDARD OF INSTALLATION 1988. WARNING LIGHT (INCANDESCENT BULB) ABOVE THE DOOR OUTSIDE THE ROOM WITH ( —� w *REIAY CONDUITS FOR CONNECTIONS TO SIEMENS CABINET VIA RELAY BOX. SEE WARNING LIGHT 2) QUALITY ASSURANCE: THE CONTRACTOR SHALL VERIFY z 24 VAC SUPPLIED DIAGRAM ON THIS SHEET. f EXISTING CONDITIONS IN THE FIELD TO INSURE THAT THE NEW o. NORMALLY OPEN 24 VAC WORK WILL FIT TO THE EXISTING STRUCTURE AS SHOWN ON THE j z OA S.B.C. RECESSED, WALL MOUNTED JUNCTION BOX AT FLOOR LINE WITH REMOVABLE COVER FLUSH DRAWINGS. SHOULD ANY CONDITIONS EXIST OR BE DISCOVERED O I z WITH FINISHED WALL (FOR POWER CONNECTION TO X-RAY GENERATOR). THAT PREVENT THE INSTALLATION OF WORK AS SHOWN, THE i CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE PRIOR TO c� ®© 10 x 3 1/2" OPENINGS IN THE ENDS OF #2a f FABRICATION OF EQUIPMENT OR THE PERFORMANCE OF ANY WORK I"- WL J 24*RELAY C OB ® 3"0 TERMINATION POINTS OF CONDUIT #9 FLUSH WITH FINISHED FLOOR, UNDER SIEMENS ! PECIFICAT ONS IN ANY WAY WITHOUT CONTACTING AND DIMENSIONS,RECEIVING OR A W M 11 •� li �-2 NORMALLY CLOSED SUPPLIED EQUIPMENT. EXACT LOCATION TO BE DETERMINED BY MED-LAB REPRESENTATIVE. ! I B3 24 VAC I WRITTEN CONFIRMATION FROM SMS PROGRAM MANAGER. ALL ♦� ROOM ®® 10 x 3 1/2" OPENINGS IN THE ENDS OF #2b DIMENSIONS ARE INSTALLED ED FINISHED HED URFACM R CONDUIT AND T R WITH iii O W r LIGHTS 6 FT. PIGTAIL ® 2 1/2 TERMINATION POINT OF CONDUIT #11 FLUSH WITH FINISHED FLOOR UNDER SIEMENS j LOCATIONS BEING FIELD VERIFIED BY SMS PROGRAM MANAGER. ® � M co�o D I " STAND. EXACT LOCATION TO BE DETERMINED BY MED-LAB REPRESENTATIVE. I W co I 3) POWER SUPPLY SOURCE: POWER SUPPLIES FOR SIEMENS f 0 10 x 10 x 4"D CEILING MOUNTED JUNCTION BOX WITH ONE 2"0 SPLIT CHASE NIPPLE ON SPLIT, MEDICAL SYSTEMS EQUIPMENT SHALL BE DEDICATED SERVICES KEPT CONTRACTOR To *RELAY WITH A 24 VOLT REMOVABLE COVER FLUSH WITH FINISHED CEILING. i ENTIRELY FREE AND INDEPENDENT OF ALL OTHER BUILDING WIRING M Q j L CONTROL SHUNT I , AC COIL (NOT TO EXCEED 5 WATTS). TRIP DEVICE IN SUPPLIED BY ELECTRICAL CONTRACTOR. SIEMENS TO PROVIDE CONTROL r AND EQUIPMENT, SUCH AS: ELEVATORS, GENERATORS, PUMPS, HVAC 3 CBI. SEE POWER SIGNAL TO REIAY. CONTRACTOR SUPPLIED & INSTALLED JUNCTION BOX. F1 P ---- REFERENCE POINTS AND OPENINGS FOR CABLE OUTLETS IN COVER OF #6. EXACT SIZE SYSTEMS, ETC. THE CONTRACTOR SHALL COORDINATE THIS WORK in "P. , TO ROOM LIGHTS RELAY DIAGRAM ON THIS AND LOCATION TO BE DETERMINED BY MED-LAB REPRESENTATIVE. f WITH THE CUSTOMER/UTILITY COMPANY FIELD REPRESENTATIVE. 00 Lr 5 JB BOX SHE CONTROL ROOM LIGHTING AND DOOR SWITCH SCHEMATIC J N ---- REFERENCE POINTS AND OPENINGS FOR CABLE OUTLETS IN COVER OF #13. EXACT SIZE Q. O I AND LOCATION TO BE DETERMINED BY MED-LAB REPRESENTATIVE. 4) WORK FURNISHED BY CUSTOMER/CONTRACTOR: WORK NOT ® O J l 13 PROVIDED BY SIEMENS MEDICAL SYSTEMS BUT SHOWN ON DRAWINGS Va °' 2b ORIENTATION POINT PO N 1002 WARNING LIGHTS NONEE• QH 2 1/2-0 SPLIT CHASE NIPPLE ON SPLIT, TO BE FURNISHED AND INSTALLED BY CUSTOMER/CONTRACTOR U �'�' REMOVABLE COVER OF VERTICAL DUCT #5 AT 12 ♦A O Ba M CENTER BELOW FINISHED CEILING. EXACT LOCATION TO BE DETERMINED BY MED-LAB. t INCLUDES THE FOLLOWING BUT IS NOT LIMITED TO UNLESS NOTED V♦ I TO LASER IMAGE 5 •I ° i OTHERWISE: ELECTRICAL RACEWAYS AND DUCTS, WIRING TROUGHS, O 1 L L1 S.B.C. CEILING MOUNTED JUNCTION BOX WITH REMOVABLE COVER FLUSH WITH FINISHED I PULL BOXES, CONDUITS, CIRCUIT BREAKERS, EMERGENCY OFF �' O N CEILING. FOR LIGHT BARRIER TRANSMITTER AND RECEIVER. I BUTTONS, DOOR SWITCHES, WARNING LIGHTS, WIRING, WIRING ° DEVICES, CONNECTORS, LIGHTING EQUIPMENT AND GROUNDING. 7 . .i e H 10 8 J P S.B.C. WALL MOUNTED, RECESSED JUNCTION BOX ABOVE WINDOW, WITH REMOVABLE COVER. SP2 Q 5) RACEWAY AND CONDUIT NOTES: RACEWAY SHALL BE ELECTRIC O PO P 0 LY D 0 R 0 S S X H O 1 S.B.C. CONDUIT AND WIRES FROM "CBI" TO "A". SEE POWER DIAGRAM ON THIS SHEET. f METALLIC TUBING (EMT) FOR RIGID CONDUIT WORK, OR WHERE ® J 9 1/2 F1 SP1 2a 2b 1 O"W x 3 1/2"D SURFACE MOUNTED FLOOR RACEWAY ALONG THE WALL., BETWEEN SIEMENS CABINETS, ! SHORT OFF-SET CONNECTIONS ARE REQUIRED LIQUIDTIGHT FLEXIBLE d RDIAG g1 X—RAY GENERATOR POWER REQUIREMENTS DIVIDED INTO THREE EQUAL SIZE COMPARTMENTS, WITH REMOVABLE COVER ON TOP. METAL CONDUIT SHALL BE USED. FIELD BENDS SHALL NOT BE LESS CO L THAN AS SHOWN IN TABLE 346-10 OF THE NATIONAL ELECTRICAL \ Bb 20 INCOMING POWER: 480 VOLTS, 3 PHASE, 60Hz "1'" 3 10 EMPTY CONDUIT BETWEEN #10 AND L i CODE. PROVIDE A JETLINE "SUPER TRUE TAPE", OR EQUIVALENT E t` 12° " # CONDUIT MEASURING TAPE FISH LINE IN ALL RACEWAYS AND FLU❑R❑ CIRCUIT BREAKER: 100 AMPS. 4 10 EMPTY CONDUIT BETWEEN #10 AND L1 I CONDUITS. R 1 -10 1/4 4 12 ROOM #31 6 WORK 0 A Aa RUN THE SHORTEST GENERATOR OUTPUT: 80 KW AREA O " " CONDUIT BODIES SHALL NOT BE USED. WHERE A CONDUIT ENTERS A I . POSSIBLE WAY ABO 5 10 W x 3 1/2 D RECESSED, WALL MOUNTED VERTICAL DUCT RUNNING FROM FLOOR TO ABOVE FINISHED C41 FlN. CEILING F 1001 1008 ALLOWABLE IMPEDANCE: 0.16 OHMS. CEILING, DIVIDED INTO THREE EQUAL SIZE COMPARTMENTS, WITH REMOVABLE COVER i BOX, FITTING, OR OTHER ENCLOSURE, AN INSULATED THROAT FEEDER SIZE: 3) # 2 A.W.G. ON THE FACE OF THE TRENCH DUCT AND FULL, CLEAR ACCESS INTO #10. CONNECTOR SHALL BE PROVIDED TO PROTECT THE WIRE FROM I .� 6'-8" BREAKER TO LOAD 1 ABRASION. CONNECTORS SHALL BE DOUBLE SET SCREW TYPE, STEEL c # 2 A.W.G. NEUTRAL 6 10"W x 3 1/2"D SAME AS #5 (DIFFERENT LOCATION, FULL, CLEAR ACCESS INTO #10 AND #13). CONCRETE TIGHT. c w I 1 CB1 L1 1 2 A.W.G. ISOLATED GROUND 7 2 1/2"0 EMPTY CONDUIT TO LASER IMAGER LOCATION (VERIFY SIZE) KEEP RACEWAYS AT LEAST 6 INCHES AWAY FROM PARALLEL RUNS OF a TOTAL INCOMING KVA REQ: 145 i c FLUES OR STEAM AND HOT WATER PIPES. INSTALL HORIZONTAL � LINE VOLTAGE VARIATION: f 10% MAX. 8 3/40 EMPTY CONDUIT BETWEEN SP2 AND #10 ABOVE FIN. CEILING. RACEWAY RUNS ABOVE WATER AND STEAM PIPES PROVIDED THAT o 4'-O" PHASE BALANCE: 2% •� CABLE RUN DISTANCES ARE MAINTAINED. USE TEMPORARY CLOSURES MAX BETWEEN ANY 2 PHASES gO 31'0 EMPTY CONDUIT BETWEEN B AND B1. RUN THE SHORTEST POSSIBLE WAY BELOW FLOOR ! � FREQUENCY VARIATION: f 1 Hz SLAB. CONDUIT TERMINATION AT B AND B1 TO BE FLUSH WITH FINISHED FLOOR. !I TO PREVENT FOREIGN MATTER FROM ENTERING RACEWAY. o ? VOLTAGE SURGES: 10% MAX. ABOVE LINE VOLTAGE " f CONDUIT RUNS ARE SHOWN SCHEMATICALLY. INSTALL CONDUIT WITH PREP. 10 10 W x 3 1/2"D RACEWAY ABOVE FINISHED CEILING, DIVIDED INTO THREE EQUAL SIZE CONDUIT AN CONDUITS AND AREA INSTANTANEOUS VARIATION: 20 msec. MAX. DURATION COMPARTMENTS, WITH REMOVABLE COVER ON TOP AND WITH FULL, CLEAR ACCESS ! A MINIMUM OF BENDS IN THE SHORTEST PRACTICAL DISTANCE POWER CABLE BY WIRES BY CONSIDERING THE BUILDING CONSTRUCTION AND OBSTRUCTIONS, CONTRACTOR TO INTO #5 AND 6 AND VARIOUS CONDUITS. I 0 POWER DIAGRAM TO HOSPITAL'S PANEL CONTROL SHUNT 1009 VOLTAGE SAGS: 10% MAX. BELOW LINE VOLTAGE i EXCEPT AS OTHERWISE INDICATED. THE CONTRACTOR SHALL MAKE O x ON THIS SHEET TRIP DEVICE IN 20 msec. MAX. DURATION 11 2 1/2"D EMPTY CONDUIT BETWEEN BOTTOM OF #5 AND B3. RUN THE SHORTEST POSSIBLE WAY CERTAIN THAT ANY CONDUIT/RACEWAY RUNS CONTAINING SIEMENS CONFERENCE cBI. SEE POWER BELOW FLOOR SLAB. CONDUIT TERMINATION AT B3 TO BE FLUSH WITH FINISHED FLOOR. MEDICAL SYSTEMS CABLES DO NOT EXCEED THE SPECIFIED MAXIMUM ROOM DIAGRAM ON THIS LINE TRANSIENTS (SPIKES): 50% MAX. ABOVE LINE VOLTAGE WITH FINISHED FLOOR, WITH "Aa" AND "B3" OPENINGS FOR CABLE ACCESS INTO DISTANCES AS SHOWN ON THE ELECTRICAL DETAILS. co SHEET 5 msec. MAX. DURATION SIEMENS EQUIPMENT. OIL 1006 PROVIDE ENCLOSED METAL RACEWAY SYSTEM (WIRE DUCT) WHERE NEUTRAL TO GROUND: 0.5V MAX. POTENTIAL 2 1/2"0 EMPTY CONDUIT BETWEEN #10 AND "F" I SHOWN ON DRAWINGS WITH DIVIDERS TO SEPARATE THE DUCT (FOR _ 1 NEUTRAL TO GRD SURGES: t10V MAX. POTENTIAL f POWER AND SIEMENS MEDICAL SYSTEMS CABLING). DIVIDERS AND GROUND IMPEDANCE: 0.25 OHMS MAX. 13 10"W x 3 1/2"D HORIZONTAL, SURFACE MOUNTED WALL RACEWEAY AT FLOOR LINE, DIVIDED INTO THREE r CROSSOVER PIECES TO BE PROVIDED AS NECESSARY. EQUAL SIZE COMPARTMENTS, WITH REMOVABLE COVER ON THE FACE OF THE RACEWAY AN RM TEMP OPERATING LIMITS: 50' - 85* F. FULL, CLEAR ACCESS INTO #6. ; PROVIDE WIRE DUCT/RACEWAY WITH ACCESSIBLE REMOVABLE COVERS. RELATIVE HUMIDITY: 15 - 75% LOCATIONS OF OPENINGS TO BE CUT IN FIELD ARE TO BE NOTE 1: PROVIDE BUSHINGS AS NECESSARY I COORDINATED WITH SIEMENS PROGRAM MANAGER. ELECTRICAL PULL NOTE 2: ALL JUNCTION BOXES, RACEWAYS, ETC., FOR SIEMENS EQUIPMENT SHOULD BE i NOTE: BOXES AND RACEWAY COVERS SHALL BE INSTALLED IN A MANNER TO POSITIONED UNDER MED-LABS SUPERVISION. � ALLOW ACCESSIBILITY FOR INSTALLATION AND MAINTENANCE. IN- ALL INCOMING POWER SUPPLIES, FOR THE SIEMENS EQUIPMENT, NOTE 3: SEE POWER DIAGRAM AND WARNING LIGHT DIAGRAM ON THIS SHEET FOR FLOOR TRENCH DUCT AND FLUSH FLOOR BOXES SHALL BE PROVIDED ARE TO BE DEDICATED BACK TO SOURCE ISOLATED AND INSULATED ADDITIONAL INFORMATION ( ) FROM ANY OTHER EQUIPMENT, SUCH AS, ELEVATORS, GENERATORS, NOTE 4: S.B.C.=SIZE BY CONTRACTOR. WITH FULLY GASKETED REMOVABLE COVERS. HVAC SYSTEMS, ETC. NOTE 5: ALL POWER CONNECTIONS ARE BY CONTRACTOR, UP TO THE FINAL CONNECTION I WIRE DUCT RACEWAY SHALL BE MADE ELECTRICALLY CONTINUOUS IN SIEMENS CABINET (IN GREENFIELD IF NECESSARY). THROUGHOUT ITS LENGTH BY MEANS OF BONDING TOGETHER DUCT ATTENTION: NOTE 6: VERIFY SIZE OF #7 CONDUIT I I SECTIONS AT ALL JOINTS WITH AN EQUIPMENT BONDING JUMPER. BONDING JUMPERS ELECTRICAL PLAN i COPPER CONDUCTOR SHALL AND CONNECTEIDUBY MEANS OF�AN EXOTHERMIC O cli SIEMENS MEDICAL SYSTEMS, INC. RECOMMENDS THAT THE INCOMING I POWER LINES BE ANALYZED WITH RESPECT TO TRANSIENT SURGES WELDING PROCESS. SHEET METAL SCREWS SHALL NOT BE USED c SCALE: 1/4" = 1 '-0" AND IMPULSES, SAGS, AND OVERVOLTAGES. ; TO CONNECT GROUNDING CONDUCTORS. �+ a 6) WIRING: WIRING SHALL BE INSTALLED IN METAL RACEWAY, 'a I 600 VOLT CLASS, STRANDED TYPE THHN-THWN, SINGLE CONDUCTOR `c POWER DISTRIBUTION - ANNEALED COPPER FOR A MAXIMUM OPERATING TEMPERATURE OF z 75' C (165' F). SIZED AS INDICATED. THE CUSTOMER/CONTRACTOR _ SHALL LEAVE MINIMUM 10 FT. WIRE TAILS AT ALL OUTLET POINTS CONTRACTOR o N TRACT 0 R SUPPLIED CABLES __. ___ _ _ — I WITH WIRE IDENTIFICATION TAGGED AT BOTH ENDS FOR FINAL (D o _ .- - f CONNECTION BY SIEMENS MEDICAL SYSTEMS. o **CHECK DISTANCE FROM PANEL FROM VIA TO DESCRIPTION REMARKS > a memo CG IG N L1 L2 L3 TO CB1 TO DETERMINE CORRECT 7) GROUNDING REQUIREMENTS: NONCURRENT-CARRYING WIRE SIZE TO MAINTAIN IMPEDANCE CONDUCTIVE SURFACES SHALL BE GROUNDED BY A #6 A.W.G. o w co * * REQUIREMENTS # i INSULATED GREEN COPPER CONDUCTOR INSTALLED IN THE METAL �o z * j PANEL BY OTHERS CB1 DETERMINED BY OTHERS SEE POWER DIAGRAM j RACEWAY WHICH CONTAINS THE BRANCH-CIRCUIT CONDUCTORS m � � CB1 1 Aa 3 2, 1 2N, 100') ; SUPPLYING THE EQUIPMENT. o a T M SYMBOLS CB1 BY OTHERS EPO DETERMINED BY 1 OTHERS UP TO CIRCUIT � y �,10 CG IG N BREAKER ALL MAY NOT APPLY EPO BY OTHERS EPO DETERMINED BY OTHERS , i r j PANEL ( ^ LL 100 10 Aa BY OTHERS,R ELAY,#2a,5,1 0 WL 3 #12 SEE WARNING LIGHT DETAIL AMP AMP ® CAUTION OR WARNING ! z ~ 2n To ® CRITICAL NOTE(S) 0 i IO v ® CIRCUIT BREAKER BY CUSTOMER/CONTRACTOR ii I O OPENING IN RACEWAY OR TRENCHDUCT i PULLBOX IN (FLOOR/WALL/CEIUNG) cB1 o ® OPENING IN ACCESS FLOORING z I 0 EPO EPO ® WARNING LIGHT (X-RAY ON) { v w ®S DOOR SAFETY SWITCH g F= N 0 EMERGENCY C)WER (EPO) EMERGENCY POWER OFF BUTTON 0 OFF i 0 z M o BUTTON ® TRENCHDUCT { �_ N N 0 CEILING DUCT CL 0 UNDER FLOOR DUCT ® VERTICAL DUCT ETHERNET CONNECTION TO CUSTOMER'S INFORMATION Q NOTE: ETH D SYSTEMS NETWORK (VERIFY WITH SMS PROGRAM MANAGER). .� FLUOROSPOT TOP IS POWERED FROM STANDARD TELEPHONE LINE FOR REMOTE EQUIPMENT !a I N,L1,2,3 THE SYSTEM CABINET. INSTALLATION DIAGNOSTICS. THE PHONE LINE MUST BE DATA-QUALITY WITHOUT A NEUTRAL WILL REQUIRE RDIAG D WITH DIRECT DIAL-IN AND DIAL-OUT CAPABILITY SIMILAR POLYDOROS 65/80 AN EXTERNAL TRANSFORMER. TO A FAX LINE. DO NOT ROUTE THE PHONE LINE GENERATOR CABINET EXTERNAL TRANSFORMER TO BE THROUGH HOSPITAL PBX OR SWITCHBOARD. z SUPPLIED AND INSTALLED BY STANDARD TELEPHONE LINE FOR SERVICE. DO NOT W /C CUSTOMER/CONTRACTOR. SEP ROUTE THROUGH HOSPITAL PBX OR SWITCHBOARD. +XX� 110 VOLT, 20 AMP, HOSPITAL GRADE DUPLEX OUTLET G. LLst =br LOCATED NEAR THE RDIAG PHONE LINE. W a O V O o= O ijL co U O N DRAWN: J.G / Y.G 0 LO CHECKED: J.0 / R.R 0 I DATE: 6/30/2000 °m SCALE: AS SHOWN \`,QGc • ' C•. THE RC GROUP ID •• �KtF ,' ,� Consulting Engineers Sheet o. C •. F' 10821 N. Kendall Drive 3 7: Suite 215 1-y O (305) 275-8083 C+ Miami, Florida 33176 rya: E-4 ID ELECT. ENG.:JORGE L CRUZ REG. 51901 cu �'. �„ •t4< NECH. ENG.: ROBERT W. ROM! REG. 38005 l N RC# 9932 CD JOB 0: 99026