01-0057-008 I Revisions: - i WALLT`rFE GENERAL NO I ,E 5• BOTTOM OF FINISH STRUCTURAL DECK 1. GENERAL CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE APPROPRIATE FIN15H 5CONSTRUCTION OF ALL WALL TYPES AND COORDINATION OF ',ALL MECHANIC4L,, _ _ _ __ GYPSUM WALL BOARD BOTTOM OF FIN. ELECTRICAL, PLUMBING AND EXISTING CONDITIONS ,�`D;:ACENT 'TO SUCH WALLS. (-� � SUSPENSION SYSTEM STRUCTURAL DECK ROOM WAINSCOT CEILING SINCE THE WORK INVOLVES EXISTING BUILDING SYST� IS ,4NG 1=AGIL TIED, I I \ I PAINTED METAL ACCESS LR• NO. ROOM NAME FLOOR BASE WALLS REMARKS THE CONTRACTOR SHALL GIVE SPECIAL CONSIDERATION TO EXAMINATION OF I I \ I PANEL (TYPICAL) 0 MAT. HGT. MAT. HGT. ANY EXISTING CONDITIONS THAT WILL PREVENT THE CONSTRUCTION OF SUCH SCHEDULED 1001 FLUORO ROOM •31 VCT VINYL VWC ACT 10'- 3' RATED WALLS AS PER PLANS. VARIATION OF TYPICAL RATED WALL TYPES I p I RECESSED CEILING W DETAILS SHALL E3E ANTICIPATED AND SHALL BE EXPRESSLY INCLUDED AS --- WIRE HANGER I i LOCKSET SCHEDULE FINISH ON 1002 CONTROL ROOM VCT VINYL VWC ACT 8'- 6' PART OF THE WORK WHENEVER REQUIRED, AT NO ADDITIONAL COST TO THE I I I ONE LAYER 5/a' TYPE 'X' OWNER. A/E WILL SUPPLY THE DIFFERENT DETAILS FOR SUCH WALLS IF 11/2'STEEL / GYPSUM WALLBOARD CF4ANNEL I I. / SURROUNDING EACH SIDE ON OF -0 1003 WORK AREA VCT VINYL VWC ACT 8'- 6 NEEDED. IGNORANCE ON THE PART OF THE CONTRACTOR WILL IN NO WAY 3/4'FURRIW3 V CHANNEL FRAME. RELIEVE HIM OF THE OBLIGATIONS AND RESPONSIBILITIES ASSUMED UNDER VARIES CWANNEL5 3 5/8' METAL STUD 1- 1004 PREP.AREA VCT VINYL VWC ACT 8'- 6' 16' O.C. (TYP) N THIS CONTRACT. CHA�,EL L 1005 NEW IMAGE DEV. QT QT EPDXY PAINT ACT 8'- 6' • EPDXY GROUT 1006 CLEAN UP FACILITY VCT VCT VU1C ACT 10'- 3' 2• GENERAL CONTRACTOR SHOULD MARK ALL SMOKE WALLS /FIRE WALLS ABOVE THE CEILING CHANNEL FRAME WITH PAINT TO READ ACCORDING TO THE WALL RATING AS SUCH: LETTERS MUST BE 1 1/2' FOR ONE HOUR WALLS AND 3' FOR TWO HOUR AND SMOKE WALLS AS FOLLOWS: 1777"''"' 1007 CADI STORAGE QT CT EPDXY PAINT CT 5'-0' ACT 8-- 6- ' EPDXY GROUT \ SMOKE /FIRE WALL (PROTECT ALL PENETRATIONS) 1 I/2' (TYPICAL) I I Z 3• 3' TWO HOUR FIRE WALL (PROTECT ALL PENETRATIONS) I \\ \ SUSPENDED ONE HOUR CORRIDOR WALL (PROTECT ALL PENETRATIONS) SUSPENDED GYP BOARD \ \ GYPSLIM WALL sr ONE HOUR SMOKE PARTITION (PROTECT ALL PENETRATIONS) CL \ \ CEILING O 4. PROVIDE 2" WIDE PAINTED RED LINE AT ALL STORAGE ROOMS, LOCATED 18' BELOW \ \ LOCK BOTTOM OF SPRINKLER HEAD/CEILING, WITH 2" HIGH RED LETTERS TO READ 'NO STORAGE \ \ MEaIAxISM SOUND ATTENUATION BLANKET 1�1 ABOVE RED LINE'. \ PANTED METAL ACCESS TO UNDERSIDE OF STRUCTURE M 5. PANEL(TYPICAL) `■/ PROVIDE PRESSURE TREATED FIRE-RETARDANT PAINTED WOOD SILL NAILER AT PERIMETER RECESSED GYPSUM WALL BOARD LOCK SET. FRAMING SYSTEM SCHEDULE BASE > OF ALL ROOMS WITH WOOD SASE (SEE FINISH SCHEDULES) �- I � M ALL PARTITIONS SHALL BE 4' NOMINAL DIMENSION UNLESS OTHERWISE NOTED ON PLANS. PLASTER BEADS 6. INTERIOR WALLS,PERMANENT PARTITIONS (RATED OR NOT)AND TEMPORARY PARTITIONS SHOULD HINGE ® M SUPPORT A MINIMUM OF (5)POUNDS PER SQUARE FOOT APPLIED PERPENDICULAR PAINTED METAL DOOR p,� / TO THE WALL. O � (n 1 PROVIDE BACKING SUPPORT AT ALL PARTITIONS WHERE EQUIPMENT IS INDICATED TO BE MOUNTED. A 8. INSTALL METAL STUDS AT Iro' O.C. WITH GYPSUM WALLBOARD HUNG VERTICALLY. NOTE: FOR SIZE d LOCATION S. GENERAL CONTRACTOR TO VERIFY ANY EXISTING PARTITIONS WITH NEW WALL TYPE DESIGNATIONS SE MECHANICAL d ELECTRICAL DRAWINGS AND UPGRADE AS REQUIRED TO REFLECT NOTED WALL TYPES. 10. SUPPORT OF SOFFITS FROM RATED PARTITION IS APPROVED, ONLY IF THEY ARE ATTACHED DIRECTLY TO 1��1 METAL STUDS AND/OR STRUCTURAL BACKING ONLY. ATTACHMENT TO GYP.WALLBOARD IS NOT ALLOWED. 1 ACCESS PANEL SECTION N.T.S. (2) ACCESS PANEL, REFLECTED CEILING N.T.S. O r 11. ALL EXI5TING/NEW EXTERIOR MASONRY WALLS TO HAVE SCHEDULE SCHEDULE FINISH ON 5/8' TYPE 'X' HINGE DETAILS � ) V, GYPSUM WALLBOARD ON I-5/8' METAL STUDS AT 16' O.C.OVER RIGID INSULATION BOARD (TYPICAL AT BOTTOM OF FINISH STRUCTURAL PECK V ROOM SIDE OF ALL FINISHED ROOMS ONLY). v` O 12, ALL EXTERIOR MASONRY WALLS TO HAVE ONLY RIGID INSULATION AT ALL UNFINISHED ROOM SIDES. , ' SEAL TIGHT (TOP d 13. PROVIDE CONTINUOUS (UNINTERRUPTED BY FURRING)R-4.5 (MIN.)RIGID INSULATION BOARD AT ALL D s > m e'e. . BOTTOM) AT SMOKE N EXTERIOR BLOCK/CONCRETE WALLS FACING AIR CONDITIONED SPACES. INSTALL FROM FINISH SLAB TO TIGHT PARTITION �1 UNDERSIDE OF STRUCTURAL DECK. GYPSUM WALLBOARD TO CONCEAL INSULATION TO UNDERSIDE OF FACE OF FINISHED WALL UNDERSIDE OF O FINISHED STRUCTURAL DECK OR WINDOW MULLION 14, ALL DIMENSIONS SHOWN ON FLOOR PLANS ARE EITHER ROUGH (STUD TO STUD)OR MASONRY (MASONRY CONC. SLAB CEILING BACKING SCHEDULED (MASONRY TO MASONRY OR MASONRY TO STUD)TYPICAL U.O.N. STUD CEILING 0 15. IT IS THE INTENT FOR THE RATED BARRIER TO BE BUILT FIRST IN COMPLIANCE WITH THE UL.NO. AS QUOTED. SCHEDULE FINISH ON FINISH SCHEDULE NOTES ALL OTHER PARTITIONS ABUTTING RATED PARTITION SHALL NOT BE CONSTRUCTED UNTIL AFTER THE ONE LAYER 5/8' TYPE 'X' RATED PARTITION IS 100q COMPLETED. GYPSUM WALLBOARD EACH SIDE ON 16. IT IS REQUIRED THAT AFTER THE METAL STUD FRAMING IS COMPLETED ON A RATED PARTITION THAT THE 3 5/8' METAL STUDS COMPANY PROVIDING THE SYSTEM INSPECTS AND CERTIFIES IN WRITING THAT THE FRAMING HAS BEEN ( 6' METAL STUDS 'm 2a ) 1.ALL INTERIOR FINISHES SHALL MEET THE FOLLOWING REQUIREMENTS: PERFORMED IN COMPLIANCE WITH THEIR REQUIREMENTS AND U.L. LABEL. SAME CERTIFICATION SHALL CEILING SUSPENSION BE PROVIDED FOR GYPSUM WALLBOARD INSTALLATION,SCREWING AND TAPING. CONTRACTOR IS SYSTEM TO UNDERSIDE PROVIDE METAL STUDS AT ALL INTERIOR FINISHES SHALL BE CLASS'A'WITH FLAME SPREAD 0-25 AND SMOKE DEVELOPED 0-450. RESPONSIBLE FOR PLACING ELECTRICAL,MEDICAL GAS AND OTHER OUTLETS AND BOXES IN SUCH A - OF EXIST.STRUCT. ALL FLOOR FINISH IN CORRIDORS AND EXITS SHALL BE CLASS'I"MINIMUM 0.45 WATTS PER SO.CNt FASHION AS TO NOT VIOLATE INTEGRITY OR STG RATING OF PARTITION. WALLBOARD HORIZONTAL JOINTS •v M. ALL EXISTING MASONRY WALLS OR CONCRETE COLUMNS IN AREAS AFFECTED BY NEW RENOVATIONS ct EXCEPTIONS:CLASS'S'INTERIOR FINISH WITH FLAME SPREAD 26-75 AND SMOKE DEVELOPED 0-450 MAY BE USED IN SMALL INDIVIDUAL ROOMS OF NOT OVER SHALL RECEIVE SCHEDULED FINISH ON 5/a' TYPE 'X' GYPSUM WALLBOARD ON 7/8' METAL FURRING CERAMIC TILE FINISH u" FOUR PERSONS CAPACITY,OTHER THAN EXITS AND ACCESS TO CORRIDOR EXITS. STRIPS AT 16' O.C. (TYPICAL UNLESS OTHERWISE NOTED ON PLANS), r WATER RESISTANT 5/8' ' ACOUSTICAL GYPSUM WALL BOARD 2.ALL WALLS CEILING FINISHES TO BE CLASS'A'FINISH(0-25)FLAME 18. BLOCK UP ALL PENETRATIONS THROUGH EXISTING EXTERIOR WALLS DUE TO THE REMOVAL OF EXISTING ; CEILING PANEL v� EQUIPMENT WITH RINKER TYPE T-18 OR T-IIA,RE-STUCCO EXTERIOR FACE AND PAINT TO MATCH EXISTING 3. INTERIOR FINISH IN CORRIDORS SHALL BE CLASS"1'. ADJACENT. (SEE MECHANICAL DRAWINGS) 2b METAL ANGLE STRIP O q 4. ALL NEW GYPSUM WALLBOARD CEILINGS AND SOFFITS TO BE 5/8'TYPE X. FINISH TO MATCH F� 'I' SYSTEM SOUND ATTENUATION BLANKET 5. PROVIDE WATER-RESISTANT GYPSUM WALLBOARD IN ALL WET AREAS AND FINISH WITH ENAMEL PAINT NOTE: CONTRACTOR TO PROVIDE WATER RESISTANT WALL BOARD IN ALL WET AREAS, AND ON TO UNDERSIDE OF STRUCTURE '`� 6. CONTRACTOR TO REPAIR,PATCH, AND REPAINT ALL DAMAGED FINISHESAS REQUESTED IN ALL EXISTING REFINISHED AND REMODELED AREAS. ALL TILED SURFACES. (TYPICAL) 'T' RUNNER SUSPENDED ACOUSTICAL SCHEDULE BASE CEILING TILE: SEE FINISH SLAB Q cu 7. ALL EXTERIOR PATCH UP WORK TO BE REPAIRED AND RESTORED TO MATCHEXISTING FINISHES AND COLORS. CEILING PLAN 8. ALL EXISTING DOOR FRAMES IN AREAS WHERE NEW WORK IS TO BE DONE,ARE TO RECEIVE NEW PAINT/STAIN AS SELECTED BY ARCHITECT/INTERIOR DESIGNER OR owNER. j SECTION 9.EXISTING AREAS TO BE RETAINED,PATCH AND REPAIR/REPLACE AS REQUIRED TO MATCH EXISTING ADJACENT FINISH. ISM(<E PARTITION RE IOU I REMENTS= cA d 10. ALL PAINT TO MEET OR EXCEED HEALTH SPEC., BENJAMIN MOORE,AQUA VELVET 1. 3 CEILING DETAILS (4)N.T.S. CEILING DETAILS N.T.S. O 2a 2b M II. PLASTIC LAMINATE TO MEET OR EXCEED SOUTH MIAMI HOSPITAL STANDARDS, BASE E OVERHIEAD&WILSONART COUNTERTOPS WISONART A. SMOKE PARTITIONS SHALL BE CONTINUOUS FROM EXTERIOR WALL 12 BASE TO MEET OR EXCEED SOUTH MIAMI HOSPITAL STANDARDS. TO EXTERIOR WALL. AT POINTS OF INTERSECTION WITH OTHER PARTITIONS, THE INTEGRITY OF THE SMOKE WALL MUST BE Q 13. VINYL FLOOR TILE TO MEET OR EXCEED SOUTH MIAMI HOSPITAL STANDARDS, TYPICAL MAINTAINED AND THE INTERSECTING PARTITIONS BUTTED TO a ACCENT:MANNINGTON,ESSENTIALS,u SIZE 12'X12' IT. THE SMOKE PARTITION IS AL50 TO BE CONTINUOUS FROM 14, CEILING TILE TO MEET OR EXCEED SOUTH MIAMI HOSPITAL STANDARDS, ARMSTRONG-TECHLJLA12 FLOOR SLAB TO UNDERSIDE OF STRUCTURE (SLAB) ABOVE. 15. CONTRACTOR TO PROVIDE SHOP DRAWINGS AND/OR SAMPLES TO A/E FOR APPROVAL B. IN SMOKE AND CORRIDOR PARTITIONS, ALL PENETRATIONS, ib, ALL ACCESSORIES ARE TO MEET SOUTH MIAMI HOSPITAL STANDARDS. INCLUDING CONDUITS, A/C DUCTS ETC., MUST BE SEALED TO BOTTOM OF FINISH STRUCTURAL PECK 17. CERAMIC TILE: FIELD:PATTERN,BY,COLOR NEW ACCENT PATTERN,BY,COLOR MAINTAIN THE FIRE RATING INTEGRITY AS REQUIRED BY GoNC.SLAB 18. VINYL WALL COVERING BORDER PATTERN,BY,COLOR A.H.0-A. AND ALL GOVERNING AUTHORITIES. SEALANT(BOTH SIDES) ONE HOUR CONSTRUCTION NOTE FIELD:PATTERN,BY,COLOR C. ALL DUCT PENETRATIONS OF SMOKE PARTITIONS AND FIRE 3-5/8' CEILING BACK-UP STUD ONE LAYER 5/8' TYPE 'X' GYPSUM ACCENT PATTERN,BY,COLOR RATED PARTITIONS MUST BE DAMPERED ACCORDING TO THE MTL. STUDS WALLBOARD APPLIED AT RIGHT ANGLES 19. CUBICAL CURTAINS: WIDTH:72' .9 I6' O.C. ACOUSTICAL SPECIFIC FIRE RATING REQUIRED: METAL STUDS. CEILING SCHEDULED OR PARALLEL TO EACH SIDE OF 3 516' 20, ARCOVYN WALL/DOOR PROTECTION:COLOR CEILING MIN.METAL STUDS m 16' O.C.W/ i' 21. ALL FINISHES TO MEET OR EXCEED NFPA 253✓;255. SMOKE PARTITIONS -COMBINATION 5.D./F.D. SCHEDULE FINISH ON TYPE S DRYWALL SCREWS 8' O.C.TO PAINTED FIRE PARTITIONS -FIRE DAMPER � ONE LAYER 5/8' TYPE "X' GYPSUM ^ VERTICAL EDGES AND 12'O.C.TO TOP AND 21. QUAKY TILE: FIELD:PATTERN,BY,COLOR, 3/4 P.T. m ACCENT'PATTERN,BY,COLOR HORIZONTAL EXIT -COMBINATION S.D./FD. PLYWOOD WALLBOARD EACH SIDE OF METAL BOTTOM RUNNERS AND VERTICAL A D CORRIDOR WALL -SMOKE DAMPER FIRE TREATED STUDS STUDS.STAGGER ALL VERTICAL AND O rr6► FLOOR ASSEMBLY OR HORIZONTAL JOINTS 16' O.C.EACH IV/ METAL CORNER GUARD 3 5/8',6' OR S' METAL STUDS tp SIDE AND OPPOSITE SIDES. (NL.B.) VERTICAL SHAFT -COMBINATION S.D./F.D. ACROSS SOFFIT. ACOUSTICAL AT 16' O.C. _ HAZARDOUS ROOMS -COMBINATION S.D./F.D. CEILING THE � (U.L.. PfL-E= iV0_ U 4g;S>E .) SOFFIT(WHERE 5/8' G.W.B• PROVIDE METAL STUDS AT l7 NOTE: CONTRACTOR SHALL SUPERVISE SOFFIT (WHERE cq WALLBOARD HORIZONTAL JOINTS APPLICABLE)SEE APPLICABLE)SEE D. ACCESS DOORS SHALL BE PROVIDED (FIRE RATED WHERE REQUIRED) LL u1 12 W AND INSPECT CONSTRUCTION OF ALL WALLS F ) 0 INTERIOR ELEVATIONS INTERIOR ELEVATIONS AND LOCATED IN THE INACCESSIBLE AREAS ADJACENT TO SMOKE Z } = TO VERIFY THAT CONSTRUCTION IS !!�' �Go PERFORMED IN ACCORDANCE TO - ` NO HARDWOOD AND FIRE PARTITIONS TO ALLOW ALL PARTS OF PARTITIONS TO BE U- > N -i SPECIFICATIONS ABOVE.ANY VARIATIONS BACKING HARDWOOD cp VISUALLY INSPECTED, MAXIMUM SPACING OF PANELS SHALL BE 30'. DOOR FRAME iv u SHALL 8E BROUCx1-IT TO THE ' QO BACKING z ACTUAL DIM. 4 T/8' FOR 3 5/8' STUD X A5 -,C_1 .4TTENTION. TO PLIWbOD - 5/8'PLYWOOD FACING 3/4' PLYWOOD �= E. ALL PIPES, CONDUITS AND DUCTS AT ALL Sl"IOKE/FIRE WALL r c ACTUAL DIM.1 1/4' FOR 6' STUD Q TOP WITH PLASTIC PENETRATIONS SHALL BE DONE AT 90 DEGREES ON BOTH SIDES. NOTE: DO NOT SUPPORT SOFFIT O ACTUAL DIM. 9 I/4' FOR 8' STUD 23 LAMINATE FINISH TOP I > IL O a 1/4'HARDWOOD I/4' HARDWOOD BACKIN�s > BACKING uIi FROM FIRE RATED PARTITIONS. ~ SOUND ATTENUATION BLANKET O v> AT FIRE PARTITIONS ANCHOR TO W STRUCTURE ABOVE. Z 3/4'ADJUSTABLE 1Y F. ANY RECESSED ITEM IN THE SMOKE PARTITION OVER 4'x4' MUST BE ENCASED TO UNDERSIpE OF STRUCTURE e� '� PLYWOOD SHELF 3/4' PLYWOOD - O IN A FIVE SIDED 5/8" TYPE "X' GYPSUM WALLBOARD BOX. N U 3/4'PLYWOOD - SEALANT (BOTH SIDES) 4 ENDS o WITH PLASTIC ENDS 5 CEILING DETAILS NTS CEILING DETAILS DOOR HEAD CT1'P.) N.T.S. =� w LAMINATE FINISH CONTRACTOR IS RESPONSIBLE FOR PROVIDING ADEQUATE BACK BOXING FOR ITEMS +' LINE BORING WITH Z 3/4' ADJUSTABLE FINISH SLAB e� .- 4 CHROME PIN(TYP.) - � � PLYWOOD SHELF (EXCEEDING 16 50. IN-) RECESSED IN A FIRE PARTITION. HARDWOOD HARDWARE(SEE Lu WITH PLASTIC H BACKING 5PEC5)7YPICAL _ LAMINATE FINISH BACK BOXING SHALL BE OF SUCH CONSTRUCTION AS TO COMPLY WITH FIRE RATING CEILING SUBRAIL OR SECTION ,C N O 3/4'PLYWOOD CHROME PIN TIYP.) REQUIREMENTS FOR THE PARTITION. BOTTOM FINISH WALL OR HARDWOOD EXISTING STRUCTURE BACK5PLASH(5EE THESE ITEMS INCLUDE, BUT ARE NOT LIMITED TO: 3 u INIERIORELEV) BACKING - ELECTRICAL JUNCTION BOXES MED. GAS OUTLETS, VALVE BOXES AND ALARM BOXES ° O TYPICAL ONE-HOUR FIRE-RATED SMOKE PARTITION F- ° t0 BE REFERENCE TO RESTORE EEX18TING WALL 0 IPJDERCABI�T FIRE EXTINGUISHER CABINETS WATER COOLERS ° 45° ANGLE O LIGNt Flxtu _ ° CONNECTORS O W? 3/4' PLYWOOD O FIRE HOSE CABINETS TELEPHONES 0 (SEE ELECTRICAL 1=6) P-0' BOTTOM I'-o' FILM ILLUMINATORS ACCESSORIES 0 MAX. GEE O.C. WALL /�' �) I/�' �I ui lU O (STAGGERED) ONE -HOUR WALL COI -STRUCT I OI �l (TYP.UDNJ (tYP.U.ON.) Z O COORDINATE: PLACEMENT W/ CO OTHER OBSTRUCTIONS �'�` �� w� FINISH WALL OR 0 d)-i BACKSPLASH (SEE INTERIOR ELEV.) O SAME WITHOUT 0 '4 IBJDERCABNET LIGHT � ° 0 UNISTRUT FNISH WALL OR BACKSPLASH FINISH WALL OR BACKSPLASH 0 CONNECTIONS CAULKING CAULKING CABINET GENERAL NOTES °o ^N (TYPICAL) (TYPICAL) FINISH STRIP (METAL) /-FNISH STRIP (METAL) I. USE PLASTIC LAMINATE ON COUNTERTOPS, BACKSPLASHES AND ALL EXPOSED EDGES. 2'-0'(TYP.LOX) 2'-0'(TYP.UDN) 2• WHERE CABINET END ABUTS A WALL, PROVIDE BACKSPLASH, 6" HIGH UNLESS OTHERWISE BOTTOM OF FINISH STRUCTURAL DECK NOTED ON INTERIOR ELEVATIONS. 3/4'PLYWOOD DECKING 3/4'PLYWOOD DECKING AND SPLASH WITH PLASTIC AND SPLASH WITH PLASTIC 3. BACKSPLASH AND COUNTERTOP ARE CONTINUOUS AS SHOWN ON INTERIOR ELEVATION. SEALANT (BOTH SIDES) TWO HOUR CON5TRUCTION NOTE ILLJJ/--�-LAMINATE FINISH � T LAMINATEFNISH � 4. PROVIDE CONTINUOUS SEALANT ALONG TOP OF BACKSPLASH AT WALL. CEILING BACK-UP STUD UNISTRUT NUTS e ACOUSTICAL 4 LOWER 15i ' CEILING PANEL BASE LAYER 5/S' TYPE X GYPSUM HARDWOOD HARDWOOD 5• GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AT FIELD, COORDINATE ALL SUBRAIL = WALLBOARD APPLIED BACKNG c BACKING EQUIPMENT INSTALLED IN CABINETS, AND SUBMIT SHOP DRAWINGS TO ARCHITECT FOR SCHEDULED PARALLEL TO EACH SIDE OF --DRAWER C S APPROVAL PRIOR TO FABRICATION. CEILING 3 5/8' METAL STUDS 16' O.C. V) PI001K MAINRAIL WITH 3/4' X 5/8' WITH V TYPE S DRYWALL SCREWS W 6. REFER TO 1/4' FLOOR PLANS AND INTERIOR ELEVATIONS FOR MODIFICATIONS. 16 GA CEILING ANGLE WELDED SCHEDULE FINISH ON � FLUSH TO BOTTOM OF CHANNEL 8' O.G.TO EDGES AND 12 O.C.TO HARDWARE(SEE HARDWARE(SEE TWO LAYERS 5/8' TYPE 'X' GYPSUM "i. ARCHITECT/ INTERIOR DESIGNER TO SELECT COLOR OF ALL CABINET FINISHES. AND PAINTED WHITE INTERMEDIATE STUDS. FACE LAYER -SPECS) TYPICAL - -SPECS) WALLBOARD EACH SIDE 5/8' PLAIN OR PREDECORATED Q { _ DRAWER 8. REFER TO SHEETS A-2 INTERIOR ELEVATION. METAL STUDS p A 1/4'HARDWO. ;, TYPE 'X' GYPSUM WALLBOARD BACKING 5/8'PLYWOOD 5/8'PLYWOOD 9. ALL INTERIOR CABINET FINISHES TO HAVE PLASTIC LINERS (TYPICAL UNLESS APPLIED PARALLEL TO 3 5/S OR 6 METAL STUDS a FACING WITH a FACING WITH OTHERWISE NOTED) � n STUDS OVER BASE LAYERS WITH PLASTICLAMINATE - PLASTIC LAMINATE 10. REFER TO INTERIOR ELEVATIONS FOR INDICATION OF LOCKABLE OR NON- LOCKABLE UNISTRUT DETAIL N•T•S• �UN16TRUT DETAIL N.T.S. AT 16 O.C.c F LAMINATING COMPOUND COMBED FINISH DRAWER ►u FINISH TYPICAL PROVIDE METAL STUDS OVER ENTIRE SURFACE.METAL BASE v � -. FEATURES. REFER TO SPECIFICATIONS FOR MATERIALS, LOCKS AND HARDWARE. O[ � o b o <n 9 AT WALLBOARD 4 AND TOP RETAINER CHANNELS. a I/4'HARDWD. _ V4'HARDWD. 11. NO CABINETS ARE TO BE SUPPORTED OR HUNG FROM ANY FIRE RATED PARTITION. HORIZONTAL JOINTS > w Lu � BAGGING = STAGGER JOINTS 16' O.C.EACH BACKING z y CABINETS WILL BE HUNG FROM THE SOFFIT ABOVE OR SUPPORTED BY ADJACENT NON- LAYER AND SIDE (NLB), r� 3/4'PLYWID. - w �-w _ 3/4��YWp RATED PARTITIONS. SEE FLOOR PLANS FOR EXACT LOCATION OF FIRE RATED PARTITIONS. � r1r V) PAI DUl00D HARDWOOD DRAWER u, (TYPICAL) ' (TYPICAL) BACKNG BACKING 12. PROVIDE EASED CORNER EDGES AT ALL CABINET TOPS ABUTTING A WALL. ACTUAL DIM. 6 1/8' FOR 3 5/8 STUD X 13. ALL CABINETS ARE TO BE CONSTRUCTED OF GRADE 'A' PLYWOOD AND ARE TO BE ACTUAL DIM. 8 1/2' FOR 6' STUD E O -1X4 CKIN �z -1X4 CKIN a FASTENED TOGETHER WITH SCREWS. ACTUAL DIM.FOR 10 1/2' FOR 8' STUD BLOGCING ( UDN.) �� BLOCKING O �Q 14. ALL COUNTERTOPS CONNECTED TO WALLS MUST EITHER BE SUPPORTED BY A BASE CABINET OR A FULL LENGTH LEG SUPPORT. SEE TYPICAL DETAIL. SOUND ATTENUATION BLANKET TO UNDERSIDE OF STRUCTURE 15. MILL WORK MANUFACTURER SHALL INSTALL ONE PLASTIC GROMMET PER EACH ELECTRICAL RECEPTACLE, TELEPHONE OUTLET, CRT, OUTLET ECT. SPECIFIED ON THE SEALANT (BOTH SIDES) C, 51M WITHOUT SHELVE OR EQUIPMENT PLANS AND/ OR ELECTRICAL DRAWINGS- INSTALL WITHIN THE KNEE SPACE HANDLES, ANp BAC ING TO OF ALL CABINETS SHOWN ON EQUIPMENT DRAWINGS. FINISH SLAB SUPPORT PLUMBING LINES 16. GENERAL CONTRACTOR SHALL COORDINATE ANY NECESSARY ACCESS REQUIREMENTS FINISH WALL OR BACK5PLASH IN CABINETRY. ACCESS DOORS AND/OR ACCESS PANELS SHALL BE INCLUDED AS PART CAULKING FINISH WALL OR BACKSPLASH OF THE CABINET WORK WHEN NECESSARY TO INSTALL AND/OR SERVICE ANY TYPE OF 5EGTION (TYPICAL) CAULKNG MECHANICAL, PLUMBING OR ELECTRICAL DEVICE THAT 15 CONCEALED BY THE CABINETRY. DRAWN: AA FINISH STRIP(METAL) (TYPICAL) /-FINISH STRIP (METAL) (TYP.UDN) CHECKED- LEN 2'-1'(TYP.UDN) O TWO-HOUR FIRE-RATED SMOKE PARTITION O EXISTING; PARTITION TO BE /4'PLYWOOD DECKING 4 5 UP-GRADED (AND/OR TO MATCH)TWO-HOUR AND SPLASH WITH PLASTIC 314'PLYWOOp DECKING WITH SOUND ATTENUATION BLANKET DATE: 8/31/2000 SMOKE/FIF:E RATED (REFER 70 �T LAMINATE FINISH AND SPLASH WITH PLASTIC LAMINATE FINISH FIRE TEST: DESIGN NO.U41-60, SCALE: N.T.S. `9 PLYWOOD FACINCs WITH -5/8'PLYWOOD o ••, � FACING WITH PLASTIC LAMINATE PLASTIC LAMINATE / FINISH FNISH _ ••••, ; III ll I � WALL I ( �I � �AY,{ • J / 'X4'WOOD UNDER TWO-HOUR WALL CON5TRUCTIOI `� � �•`4i' r, FRAMING I REC01NTER ATOR I C A FILE NO. WP 1�I / 1/4'PLY ReMOVIKE REFER TO NT.ELEV. PARR w SCHEDULE % r p• ��'� w FINISH WALL I .� • R WOOD BLOKING i�' R ) t�4,�• w SCHEDULE FLOOR '`•���•���" aN%��,'•'.. £ SCHEDULE `,' I AND BASE do FINISH WALL o �BDULE FLOOR M� Sheet No. TREATMENT AREA N°' 6INK CABINET -5 c OF BIM.W/CONT. SHELF AND 4 5UPPORT EVERY 4'-6' O.C. 9 JOB 0 99011 ,